메뉴 건너뛰기




Volumn 20, Issue 1, 2013, Pages 111-119

Feasibility of myocardial perfusion imaging with half the radiation dose in obese patients using ordered-subset expectation maximization with resolution recovery software

Author keywords

image quality; myocardial perfusion imaging; obese; Radiation dose reduction; SPECT

Indexed keywords

METHOXY ISOBUTYL ISONITRILE TECHNETIUM TC 99M;

EID: 84872680985     PISSN: 10713581     EISSN: 15326551     Source Type: Journal    
DOI: 10.1007/s12350-012-9650-6     Document Type: Article
Times cited : (12)

References (24)
  • 1
    • 34948895920 scopus 로고    scopus 로고
    • Radiation dose to patients from cardiac diagnostic imaging
    • DOI 10.1161/CIRCULATIONAHA.107.688101, PII 0000301720070911000015
    • Einstein JE, Moser KW, Thompson RC, Cerqueira MD, Henzlova MJ. Radiation dose to patients from cardiac diagnostic imaging. Circulation 2007;116:1290-305. (Pubitemid 47517541)
    • (2007) Circulation , vol.116 , Issue.11 , pp. 1290-1305
    • Einstein, A.J.1    Moser, K.W.2    Thompson, R.C.3    Cerqueira, M.D.4    Henzlova, M.J.5
  • 2
    • 69349096036 scopus 로고    scopus 로고
    • Exposure to low-dose ionizing radiation from medical imaging procedures
    • 19710483 10.1056/NEJMoa0901249 1:CAS:528:DC%2BD1MXhtVKhtL7M
    • Fazel R, Krumholz HM, Wang Y, Ross JS, Chen J, Ting HH, et al. Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med 2009;361:849-57.
    • (2009) N Engl J Med , vol.361 , pp. 849-857
    • Fazel, R.1    Krumholz, H.M.2    Wang, Y.3    Ross, J.S.4    Chen, J.5    Ting, H.H.6
  • 3
    • 77955920911 scopus 로고    scopus 로고
    • Cumulative exposure to ionizing radiation from diagnostic and therapeutic cardiac imaging: A population-based analysis
    • 20619569 10.1016/j.jacc.2010.05.014
    • Chen J, Einstein AJ, Fazel R, Krumholz HM, Wang Y, Ross TS, et al. Cumulative exposure to ionizing radiation from diagnostic and therapeutic cardiac imaging: A population-based analysis. J Am Coll Cardiol 2010;56:702-11.
    • (2010) J Am Coll Cardiol , vol.56 , pp. 702-711
    • Chen, J.1    Einstein, A.J.2    Fazel, R.3    Krumholz, H.M.4    Wang, Y.5    Ross, T.S.6
  • 5
    • 78650709079 scopus 로고    scopus 로고
    • Myocardial perfusion scans. Projected population cancer risk from current levels of use in the United States
    • 21098448 10.1161/CIRCULATIONAHA.110.941625
    • Berrington de Gonzalez A, Kim K-P, Smith-Bindman R, McAreavey D. Myocardial perfusion scans. Projected population cancer risk from current levels of use in the United States. Circulation 2010;122:2403-10.
    • (2010) Circulation , vol.122 , pp. 2403-2410
    • Berrington De Gonzalez, A.1    Kim, K.-P.2    Smith-Bindman, R.3    McAreavey, D.4
  • 9
    • 75949126873 scopus 로고    scopus 로고
    • Importance of consideration of radiation doses from cardiac imaging procedures and risks of cancer
    • 20066526 10.1007/s12350-009-9189-3
    • Beller GA. Importance of consideration of radiation doses from cardiac imaging procedures and risks of cancer. J Nucl Cardiol 2010;17:1-3.
    • (2010) J Nucl Cardiol , vol.17 , pp. 1-3
    • Beller, G.A.1
  • 10
    • 61449116003 scopus 로고    scopus 로고
    • ASNC imaging guidelines for nuclear cardiology procedures: Stress protocols and tracers
    • doi: 10.1007/s12350-009-9062-4
    • Henzlova MJ, Cerqueira MD, Hansen CL, Taillefer R, Yao S. ASNC imaging guidelines for nuclear cardiology procedures: Stress protocols and tracers. J Nucl Cardiol 2009;16. doi: 10.1007/s12350-009-9062-4.
    • (2009) J Nucl Cardiol , pp. 16
    • Henzlova, M.J.1    Cerqueira, M.D.2    Hansen, C.L.3    Taillefer, R.4    Yao, S.5
  • 11
    • 84865088764 scopus 로고    scopus 로고
    • A clinical evaluation of two resolution recovery methods for reduced scan time of gated MPI SPECT
    • ASNC, St. Luke's-Roosevelt, New York, NY
    • DePuey EG, Taillefer R, Gadiraju R, Anstett F. A clinical evaluation of two resolution recovery methods for reduced scan time of gated MPI SPECT. Presented as a Late Breaking Clinical Trial Abstract, ASNC, St. Luke's-Roosevelt, New York, NY, 2006.
    • (2006) Presented As A Late Breaking Clinical Trial Abstract
    • Depuey, E.G.1    Taillefer, R.2    Gadiraju, R.3    Anstett, F.4
  • 12
    • 34547418771 scopus 로고    scopus 로고
    • Clinical results of a novel wide beam reconstruction method for shortening scan time of Tc-99m cardiac SPECT perfusion studies
    • DOI 10.1016/j.nuclcard.2007.04.022, PII S1071358107002061
    • Borges-Neto S, Pagnanelli RA, Shaw LK, Honeycutt E, Shwartz SC, Adams CL, et al. Clinical results of a novel wide beam reconstruction method for shortening scan time of Tc-99m cardiac SPECT perfusion studies. J Nucl Cardiol 2007;14:555-65. (Pubitemid 47163559)
    • (2007) Journal of Nuclear Cardiology , vol.14 , Issue.4 SPEC. ISS. , pp. 555-565
    • Borges-Neto, S.1    Pagnanelli, R.A.2    Shaw, L.K.3    Honeycutt, E.4    Shwartz, S.C.5    Adams, G.L.6    Coleman, R.E.7
  • 13
    • 47949091363 scopus 로고    scopus 로고
    • Ordered subset expectation maximization and wide beam reconstruction "half time" gated myocardial perfusion SPECT functional imaging: A comparison to "full-time" filtered backprojection
    • 18674723 10.1016/j.nuclcard.2008.02.035
    • DePuey EG, Gadiraju R, Clark J, Thompson L, Anstett F, Shwartz S. Ordered subset expectation maximization and wide beam reconstruction "half time" gated myocardial perfusion SPECT functional imaging: A comparison to "full-time" filtered backprojection. J Nucl Cardiol 2008;15:547-63.
    • (2008) J Nucl Cardiol , vol.15 , pp. 547-563
    • Depuey, E.G.1    Gadiraju, R.2    Clark, J.3    Thompson, L.4    Anstett, F.5    Shwartz, S.6
  • 14
    • 63849314304 scopus 로고    scopus 로고
    • Half time SPECT myocardial perfusion imaging with attenuation correction
    • 19289436 10.2967/jnumed.108.058362
    • Ali I, Ruddy TD, Almgrahi A, Anstett FG, Wells RG. Half time SPECT myocardial perfusion imaging with attenuation correction. J Nucl Med 2009;50:554-62.
    • (2009) J Nucl Med , vol.50 , pp. 554-562
    • Ali, I.1    Ruddy, T.D.2    Almgrahi, A.3    Anstett, F.G.4    Wells, R.G.5
  • 15
    • 78651287390 scopus 로고    scopus 로고
    • Reduced isotope dose with rapid SPECT MPI imaging: Initial experience with a CZT SPECT
    • 21069489 10.1007/s12350-010-9215-5
    • Duvall WL, Croft LB, Godiwala T, Ginsberg T, Henzlova MJ. Reduced isotope dose with rapid SPECT MPI imaging: Initial experience with a CZT SPECT. J Nucl Cardiol 2010;17:1009-14.
    • (2010) J Nucl Cardiol , vol.17 , pp. 1009-1014
    • Duvall, W.L.1    Croft, L.B.2    Godiwala, T.3    Ginsberg, T.4    Henzlova, M.J.5
  • 16
    • 79958118269 scopus 로고    scopus 로고
    • A comparison of the image quality of full time myocardial perfusion SPECT vs. wide beam reconstruction half time and half dose SPECT
    • 21287370 10.1007/s12350-011-9340-9
    • DePuey EG, Bommireddipalli S, Clark J, Leykekhman A, Thompson LB, Friedman M. A comparison of the image quality of full time myocardial perfusion SPECT vs. wide beam reconstruction half time and half dose SPECT. J Nucl Cardiol 2011;18:273-80.
    • (2011) J Nucl Cardiol , vol.18 , pp. 273-280
    • Depuey, E.G.1    Bommireddipalli, S.2    Clark, J.3    Leykekhman, A.4    Thompson, L.B.5    Friedman, M.6
  • 19
    • 84865075557 scopus 로고    scopus 로고
    • Feasibility of myocardial perfusion imaging with half the radiation dose in obese patients using ordered subset expectation maximization with resolution recovery software
    • doi: 10.1007/s12350-012-9552-7
    • Zafrir N, Solodky A, Ben-Shlomo A, Mats I, Nevzorov R, Battler A, Gutstein A. Feasibility of myocardial perfusion imaging with half the radiation dose in obese patients using ordered subset expectation maximization with resolution recovery software. J Nucl Cardiol 2012;19. doi: 10.1007/s12350-012- 9552-7.
    • (2012) J Nucl Cardiol , pp. 19
    • Zafrir, N.1    Solodky, A.2    Ben-Shlomo, A.3    Mats, I.4    Nevzorov, R.5    Battler, A.6    Gutstein, A.7
  • 20
    • 77956949443 scopus 로고    scopus 로고
    • ASNC guidelines for nuclear cardiology procedures. Single photon emission computed tomography
    • 20552312 10.1007/s12350-010-9246-y
    • Holly TA, Abbott BG, Al-Mallah M, Calnon DA, Cohen MC, DiFilippo FP, et al. ASNC guidelines for nuclear cardiology procedures. Single photon emission computed tomography. J Nucl Cardiol 2010;17:941-73.
    • (2010) J Nucl Cardiol , vol.17 , pp. 941-973
    • Holly, T.A.1    Abbott, B.G.2    Al-Mallah, M.3    Calnon, D.A.4    Cohen, M.C.5    Difilippo, F.P.6
  • 21
    • 0035235615 scopus 로고    scopus 로고
    • Updated imaging guidelines for nuclear cardiology procedures
    • 10.1067/mnc.2001.112538
    • DePuey EC, Garcia EV. Updated imaging guidelines for nuclear cardiology procedures. J Nucl Cardiol 2001;8:G5-56.
    • (2001) J Nucl Cardiol , vol.8
    • Depuey, E.C.1    Garcia, E.V.2
  • 22
    • 0038763576 scopus 로고    scopus 로고
    • Radiation dose to patients from radiopharmaceuticals (addendum 2 to ICRP publication 53)
    • ICRP publication 80
    • Radiation dose to patients from radiopharmaceuticals (addendum 2 to ICRP publication 53). ICRP publication 80. Ann ICRP 1998; 28:1-126.
    • (1998) Ann ICRP , vol.28 , pp. 1-126


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.