메뉴 건너뛰기




Volumn 38, Issue 1, 2013, Pages 167-179

Dual-energy CT of the urinary tract

Author keywords

CT urography; Dual energy; Renal mass

Indexed keywords

ALGORITHM; ARTICLE; CHEMICAL COMPOSITION; COMPUTED TOMOGRAPHIC UROGRAPHY; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; CONTRAST ENHANCEMENT; CONTRAST TO NOISE RATIO; DUAL ENERGY COMPUTED TOMOGRAPHY; DUAL LAYER DETECTOR DUAL ENERGY SCANNER; DUAL SOURCE DUAL ENERGY SCANNER; FAST KILOVOLTAGE SWITCHING DUAL ENERGY SCANNER; HUMAN; IMAGE PROCESSING; IMAGE RECONSTRUCTION; KIDNEY INJURY; NOISE REDUCTION; PRIORITY JOURNAL; RADIATION DOSE; RADIOLOGIST; URINARY TRACT; UROGRAPHY; UROLITHIASIS; X RAY TUBE;

EID: 84872678996     PISSN: 09428925     EISSN: 14320509     Source Type: Journal    
DOI: 10.1007/s00261-012-9901-7     Document Type: Article
Times cited : (32)

References (54)
  • 1
    • 0017108614 scopus 로고
    • Energy-selective reconstructions in X-ray computerized tomography
    • 967922 10.1088/0031-9155/21/5/002 1:STN:280:DyaE2s%2FhtlOntg%3D%3D
    • Alvarez RE, Macovski A (1976) Energy-selective reconstructions in X-ray computerized tomography. Phys Med Biol 21(5):733-744
    • (1976) Phys Med Biol , vol.21 , Issue.5 , pp. 733-744
    • Alvarez, R.E.1    MacOvski, A.2
  • 2
    • 0015911128 scopus 로고
    • Computerized transverse axial scanning (tomography). 1. Description of system
    • 4757352 10.1259/0007-1285-46-552-1016 1:STN:280:DyaE2c%2Fkt1Cjtw%3D%3D
    • Hounsfield GN (1973) Computerized transverse axial scanning (tomography). 1. Description of system. Br J Radiol 46(552):1016-1022
    • (1973) Br J Radiol , vol.46 , Issue.552 , pp. 1016-1022
    • Hounsfield, G.N.1
  • 3
    • 0022528983 scopus 로고
    • Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies
    • DOI 10.1118/1.595958
    • Kalender WA, et al. (1986) Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies. Med Phys 13(3):334-339 (Pubitemid 16062265)
    • (1986) Medical Physics , vol.13 , Issue.3 , pp. 334-339
    • Kalender, W.A.1    Perman, W.H.2    Vetter, J.R.3    Klotz, E.4
  • 4
    • 58949099700 scopus 로고    scopus 로고
    • Dual-energy and dual-source CT: Is there a role in the abdomen and pelvis?
    • 19195533 10.1016/j.rcl.2008.10.003
    • Fletcher JG, et al. (2009) Dual-energy and dual-source CT: is there a role in the abdomen and pelvis? Radiol Clin N Am 47(1):41-57
    • (2009) Radiol Clin N Am , vol.47 , Issue.1 , pp. 41-57
    • Fletcher, J.G.1
  • 6
    • 64249100198 scopus 로고    scopus 로고
    • Dual-energy CT iodine overlay technique for characterization of renal masses as cyst or solid: A phantom feasibility study
    • 19153744 10.1007/s00330-008-1273-6 1:STN:280:DC%2BD1M3ks1Chsw%3D%3D
    • Brown CL, et al. (2009) Dual-energy CT iodine overlay technique for characterization of renal masses as cyst or solid: a phantom feasibility study. Eur Radiol 19(5):1289-1295
    • (2009) Eur Radiol , vol.19 , Issue.5 , pp. 1289-1295
    • Brown, C.L.1
  • 7
    • 70249111173 scopus 로고    scopus 로고
    • Dual-energy CT in patients suspected of having renal masses: Can virtual nonenhanced images replace true nonenhanced images?
    • 19487466 10.1148/radiol.2522080557
    • Graser A, et al. (2009) Dual-energy CT in patients suspected of having renal masses: can virtual nonenhanced images replace true nonenhanced images? Radiology 252(2):433-440
    • (2009) Radiology , vol.252 , Issue.2 , pp. 433-440
    • Graser, A.1
  • 9
    • 78651253675 scopus 로고    scopus 로고
    • In vivo identification of uric acid stones with dual-energy CT: Diagnostic performance evaluation in patients
    • 19727931 10.1007/s00261-009-9569-9
    • Stolzmann P, et al. (2009) In vivo identification of uric acid stones with dual-energy CT: diagnostic performance evaluation in patients. Abdom Imaging 35:629-635
    • (2009) Abdom Imaging , vol.35 , pp. 629-635
    • Stolzmann, P.1
  • 10
    • 74049135424 scopus 로고    scopus 로고
    • Characterization of urinary stones with dual-energy CT: Improved differentiation using a tin filter
    • 10.1097/RLI.0b013e3181b9dbed
    • Stolzmann P, et al. (2010) Characterization of urinary stones with dual-energy CT: improved differentiation using a tin filter. Investig Radiol 45(1):1-6
    • (2010) Investig Radiol , vol.45 , Issue.1 , pp. 1-6
    • Stolzmann, P.1
  • 11
    • 77953950382 scopus 로고    scopus 로고
    • Detectability of urinary stones on virtual nonenhanced images generated at pyelographic-phase dual-energy CT
    • 20574095 10.1148/radiol.10091411
    • Takahashi N, et al. (2010) Detectability of urinary stones on virtual nonenhanced images generated at pyelographic-phase dual-energy CT. Radiology 256(1):184-190
    • (2010) Radiology , vol.256 , Issue.1 , pp. 184-190
    • Takahashi, N.1
  • 12
    • 77954089654 scopus 로고    scopus 로고
    • Single-phase dual-energy CT allows for characterization of renal masses as benign or malignant
    • Graser A et al. (2010) Single-phase dual-energy CT allows for characterization of renal masses as benign or malignant. Investig Radiol 45(7):399-405
    • (2010) Investig Radiol , vol.45 , Issue.7 , pp. 399-405
    • Graser, A.1
  • 13
    • 79951948387 scopus 로고    scopus 로고
    • Dual-energy CT with tin filter technology for the discrimination of renal lesion proxies containing blood, protein, and contrast-agent. An experimental phantom study
    • 20711733 10.1007/s00330-010-1926-0
    • Karlo C, et al. (2011) Dual-energy CT with tin filter technology for the discrimination of renal lesion proxies containing blood, protein, and contrast-agent. An experimental phantom study. Eur Radiol 21(2):385-392
    • (2011) Eur Radiol , vol.21 , Issue.2 , pp. 385-392
    • Karlo, C.1
  • 14
    • 84857633421 scopus 로고    scopus 로고
    • Dual-energy computed tomography applications in uroradiology
    • 22068585 10.1007/s11934-011-0226-9
    • Park J, et al. (2012) Dual-energy computed tomography applications in uroradiology. Curr Urol Rep 13(1):55-62
    • (2012) Curr Urol Rep , vol.13 , Issue.1 , pp. 55-62
    • Park, J.1
  • 15
    • 79960509701 scopus 로고    scopus 로고
    • Dual-energy (spectral) CT: Applications in abdominal imaging
    • 21768237 10.1148/rg.314105159 discussion 1047-50
    • Silva AC, et al. (2011) Dual-energy (spectral) CT: applications in abdominal imaging. Radiographics 31(4):1031-1046 (discussion 1047-50)
    • (2011) Radiographics , vol.31 , Issue.4 , pp. 1031-1046
    • Silva, A.C.1
  • 16
    • 79952149962 scopus 로고    scopus 로고
    • Objective characterization of GE discovery CT750 HD scanner: Gemstone spectral imaging mode
    • 21520830 10.1118/1.3551999
    • Zhang D, Li X, Liu B (2011) Objective characterization of GE discovery CT750 HD scanner: gemstone spectral imaging mode. Med Phys 38(3):1178-1188
    • (2011) Med Phys , vol.38 , Issue.3 , pp. 1178-1188
    • Zhang, D.1    Li, X.2    Liu, B.3
  • 17
    • 79959563295 scopus 로고    scopus 로고
    • Quantification of head and body CTDI(VOL) of dual-energy x-ray CT with fast-kVp switching
    • Li B, Yadava G, Hsieh J (2011) Quantification of head and body CTDI(VOL) of dual-energy x-ray CT with fast-kVp switching. Med Phys 38(5):2595-2601
    • (2011) Med Phys , vol.38 , Issue.5 , pp. 2595-2601
    • Li, B.1    Yadava, G.2    Hsieh, J.3
  • 18
    • 77955318471 scopus 로고    scopus 로고
    • Determination of renal stone composition with dual-energy CT: In vivo analysis and comparison with X-ray diffraction
    • 20807846 10.1148/radiol.10100249
    • Hidas G, et al. (2010) Determination of renal stone composition with dual-energy CT: in vivo analysis and comparison with X-ray diffraction. Radiology 257(2):394-401
    • (2010) Radiology , vol.257 , Issue.2 , pp. 394-401
    • Hidas, G.1
  • 19
    • 77953280096 scopus 로고    scopus 로고
    • Genitourinary applications of dual-energy CT
    • 20489081 10.2214/AJR.10.4404
    • Vrtiska TJ, et al. (2010) Genitourinary applications of dual-energy CT. AJR Am J Roentgenol 194(6):1434-1442
    • (2010) AJR Am J Roentgenol , vol.194 , Issue.6 , pp. 1434-1442
    • Vrtiska, T.J.1
  • 20
    • 43149117710 scopus 로고    scopus 로고
    • Analysis of fast kV-switching in dual energy CT using a pre-reconstruction decomposition technique
    • Hsieh J, Samei E (eds)
    • Zou YU, Silver MD (2008) Analysis of fast kV-switching in dual energy CT using a pre-reconstruction decomposition technique. In: Hsieh J, Samei E (eds) Proceedings of SPIE: Medical Imaging, vol 6913, pp 691313-1-12
    • (2008) Proceedings of SPIE: Medical Imaging , vol.6913 , pp. 691313-112
    • Zou, Y.U.1    Silver, M.D.2
  • 21
    • 79953672323 scopus 로고    scopus 로고
    • Accuracies of the synthesized monochromatic CT numbers and effective atomic numbers obtained with a rapid kVp switching dual energy CT scanner
    • 21626956 10.1118/1.3567509
    • Goodsitt MM, Christodoulou EG, Larson SC (2011) Accuracies of the synthesized monochromatic CT numbers and effective atomic numbers obtained with a rapid kVp switching dual energy CT scanner. Med Phys 38(4):2222-2232
    • (2011) Med Phys , vol.38 , Issue.4 , pp. 2222-2232
    • Goodsitt, M.M.1    Christodoulou, E.G.2    Larson, S.C.3
  • 22
    • 79953011586 scopus 로고    scopus 로고
    • Virtual monochromatic spectral imaging with fast kilovoltage switching: Improved image quality as compared with that obtained with conventional 120-kVp CT
    • 21330561 10.1148/radiol.11100978
    • Matsumoto K, et al. (2011) Virtual monochromatic spectral imaging with fast kilovoltage switching: improved image quality as compared with that obtained with conventional 120-kVp CT. Radiology 259(1):257-262
    • (2011) Radiology , vol.259 , Issue.1 , pp. 257-262
    • Matsumoto, K.1
  • 23
    • 84856269234 scopus 로고    scopus 로고
    • Sweet spot" for endoleak detection: Optimizing contrast to noise using low keV reconstructions from fast-switch kVp dual-energy CT
    • 22261775 10.1097/RCT.0b013e31824258cb
    • Maturen KE, et al. (2012) "Sweet spot" for endoleak detection: optimizing contrast to noise using low keV reconstructions from fast-switch kVp dual-energy CT. J Comput Assist Tomogr 36(1):83-87
    • (2012) J Comput Assist Tomogr , vol.36 , Issue.1 , pp. 83-87
    • Maturen, K.E.1
  • 24
    • 59249098264 scopus 로고    scopus 로고
    • Dual energy CT: Preliminary observations and potential clinical applications in the abdomen
    • 18677487 10.1007/s00330-008-1122-7
    • Graser A, et al. (2009) Dual energy CT: preliminary observations and potential clinical applications in the abdomen. Eur Radiol 19(1):13-23
    • (2009) Eur Radiol , vol.19 , Issue.1 , pp. 13-23
    • Graser, A.1
  • 25
    • 81355123472 scopus 로고    scopus 로고
    • Aortic endograft surveillance: Use of fast-switch kVp dual-energy computed tomography with virtual noncontrast imaging
    • 22082546 10.1097/RCT.0b013e3182372c14
    • Maturen KE, et al. (2011) Aortic endograft surveillance: use of fast-switch kVp dual-energy computed tomography with virtual noncontrast imaging. J Comput Assist Tomogr 35(6):742-746
    • (2011) J Comput Assist Tomogr , vol.35 , Issue.6 , pp. 742-746
    • Maturen, K.E.1
  • 26
    • 79953000947 scopus 로고    scopus 로고
    • Detection of renal lesion enhancement with dual-energy multidetector CT
    • 21292866 10.1148/radiol.10101170
    • Neville AM, et al. (2011) Detection of renal lesion enhancement with dual-energy multidetector CT. Radiology 259(1):173-183
    • (2011) Radiology , vol.259 , Issue.1 , pp. 173-183
    • Neville, A.M.1
  • 27
    • 82455217291 scopus 로고    scopus 로고
    • Distinguishing enhancing from nonenhancing renal lesions with fast kilovoltage-switching dual-energy CT
    • 22109292 10.2214/AJR.11.6812
    • Kaza RK, et al. (2011) Distinguishing enhancing from nonenhancing renal lesions with fast kilovoltage-switching dual-energy CT. AJR Am J Roentgenol 197(6):1375-1381
    • (2011) AJR Am J Roentgenol , vol.197 , Issue.6 , pp. 1375-1381
    • Kaza, R.K.1
  • 28
    • 84858113587 scopus 로고    scopus 로고
    • Multi-material decomposition of spectral CT images
    • Mendonca PRS et al. (2010) Multi-material decomposition of spectral CT images. In: Proceedings of SPIE, pp 76221W-76221W-9
    • (2010) Proceedings of SPIE
    • Mendonca, P.R.S.1
  • 29
    • 79960551830 scopus 로고    scopus 로고
    • Iodine quantification with dual-energy CT: Phantom study and preliminary experience with renal masses
    • 21606256 10.2214/AJR.10.5541
    • Chandarana H, et al. (2011) Iodine quantification with dual-energy CT: phantom study and preliminary experience with renal masses. AJR Am J Roentgenol 196(6):W693-W700
    • (2011) AJR Am J Roentgenol , vol.196 , Issue.6
    • Chandarana, H.1
  • 30
    • 22544471493 scopus 로고    scopus 로고
    • How I do it: Evaluating renal masses
    • DOI 10.1148/radiol.2362040218
    • Israel GM, Bosniak MA (2005) How I do it: evaluating renal masses. Radiology 236(2):441-450 (Pubitemid 41023424)
    • (2005) Radiology , vol.236 , Issue.2 , pp. 441-450
    • Israel, G.M.1    Bosniak, M.A.2
  • 31
    • 79959619261 scopus 로고    scopus 로고
    • Effect of organ enhancement and habitus on estimation of unenhanced attenuation at contrast-enhanced dual-energy MDCT: Concepts for individualized and organ-specific spectral iodine subtraction strategies
    • 21512045 10.2214/AJR.10.4858
    • Miller CM, et al. (2011) Effect of organ enhancement and habitus on estimation of unenhanced attenuation at contrast-enhanced dual-energy MDCT: concepts for individualized and organ-specific spectral iodine subtraction strategies. AJR Am J Roentgenol 196(5):W558-W564
    • (2011) AJR Am J Roentgenol , vol.196 , Issue.5
    • Miller, C.M.1
  • 33
    • 34548538709 scopus 로고    scopus 로고
    • Multi-detector CT urography: A one-stop renal and urinary tract imaging modality
    • DOI 10.1007/s00261-007-9185-5
    • Dillman JR, Caoili EM, Cohan RH (2007) Multi-detector CT urography: a one-stop renal and urinary tract imaging modality. Abdom Imaging 32(4):519-529 (Pubitemid 47383876)
    • (2007) Abdominal Imaging , vol.32 , Issue.4 , pp. 519-529
    • Dillman, J.R.1    Caoili, E.M.2    Cohan, R.H.3
  • 35
    • 84864057575 scopus 로고    scopus 로고
    • Evaluation of virtual unenhanced CT obtained from dualenergy CT urography for detecting urinary stones
    • [Epub ahead of print]
    • Moon JW, Park BK, Kim CK, Park SY (2011) Evaluation of virtual unenhanced CT obtained from dualenergy CT urography for detecting urinary stones. Br J Radiol [Epub ahead of print]
    • (2011) Br J Radiol
    • Moon, J.W.1    Park, B.K.2    Kim, C.K.3    Park, S.Y.4
  • 38
    • 84858113586 scopus 로고    scopus 로고
    • Differentiation of uric acid versus non-uric acid kidney stones in the presence of iodine using dual-energy CT
    • Samei E, Pelc NJ (eds)
    • Wang J, Qu M, Leng S, McCollough CH (2010) Differentiation of uric acid versus non-uric acid kidney stones in the presence of iodine using dual-energy CT. In: Samei E, Pelc NJ (eds) Proceedings of SPIE: Medical Imaging, vol 7622, pp 76223O-76223O-9
    • (2010) Proceedings of SPIE: Medical Imaging , vol.7622
    • Wang, J.1    Qu, M.2    Leng, S.3    Mccollough, C.H.4
  • 39
    • 77953487869 scopus 로고    scopus 로고
    • New and evolving concepts in the imaging and management of urolithiasis: Urologists' perspective
    • 20462984 10.1148/rg.303095146
    • Kambadakone AR, et al. (2010) New and evolving concepts in the imaging and management of urolithiasis: urologists' perspective. Radiographics 30(3):603-623
    • (2010) Radiographics , vol.30 , Issue.3 , pp. 603-623
    • Kambadakone, A.R.1
  • 40
    • 77955326772 scopus 로고    scopus 로고
    • Determination of renal stone composition with dual-energy computed tomography: An emerging application
    • 20691932 10.1053/j.sult.2010.05.002
    • Eliahou R, et al. (2010) Determination of renal stone composition with dual-energy computed tomography: an emerging application. Semin Ultrasound CT MR 31(4):315-320
    • (2010) Semin Ultrasound CT MR , vol.31 , Issue.4 , pp. 315-320
    • Eliahou, R.1
  • 41
    • 0034910737 scopus 로고    scopus 로고
    • Hounsfield unit density in the determination of urinary stone composition
    • DOI 10.1016/S0090-4295(01)01115-3, PII S0090429501011153
    • Motley G, et al. (2001) Hounsfield unit density in the determination of urinary stone composition. Urology 58(2):170-173 (Pubitemid 32728048)
    • (2001) Urology , vol.58 , Issue.2 , pp. 170-173
    • Motley, G.1    Dalrymple, N.2    Keesling, C.3    Fischer, J.4    Harmon, W.5
  • 42
    • 79960530909 scopus 로고    scopus 로고
    • In vivo evaluation of the chemical composition of urinary stones using dual-energy CT
    • 21700999 10.2214/AJR.10.5217
    • Manglaviti G, et al. (2011) In vivo evaluation of the chemical composition of urinary stones using dual-energy CT. AJR Am J Roentgenol 197(1):W76-W83
    • (2011) AJR Am J Roentgenol , vol.197 , Issue.1
    • Manglaviti, G.1
  • 44
    • 79960525525 scopus 로고    scopus 로고
    • Dual-energy dual-source CT with additional spectral filtration can improve the differentiation of non-uric acid renal stones: An ex vivo phantom study
    • 21606290 10.2214/AJR.10.5041
    • Qu M, et al. (2011) Dual-energy dual-source CT with additional spectral filtration can improve the differentiation of non-uric acid renal stones: an ex vivo phantom study. AJR Am J Roentgenol 196(6):1279-1287
    • (2011) AJR Am J Roentgenol , vol.196 , Issue.6 , pp. 1279-1287
    • Qu, M.1
  • 45
    • 79953652555 scopus 로고    scopus 로고
    • Effective atomic number accuracy for kidney stone characterization using spectral CT
    • Samei E, Pelc NJ (eds)
    • Joshi M, Langan D, Sahani DS, et al. (2010) Effective atomic number accuracy for kidney stone characterization using spectral CT. In: Samei E, Pelc NJ (eds) Proceedings of SPIE: Medical Imaging 2010, vol 7622, pp 76223K-1-12
    • (2010) Proceedings of SPIE: Medical Imaging , vol.7622
    • Joshi, M.1    Langan, D.2    Sahani, D.S.3
  • 47
    • 67349191462 scopus 로고    scopus 로고
    • Dual-energy CT for the characterization of urinary calculi: In vitro and in vivo evaluation of a low-dose scanning protocol
    • 19205704 10.1007/s00330-009-1300-2 1:STN:280:DC%2BD1MzktFKisQ%3D%3D
    • Thomas C, et al. (2009) Dual-energy CT for the characterization of urinary calculi: in vitro and in vivo evaluation of a low-dose scanning protocol. Eur Radiol 19(6):1553-1559
    • (2009) Eur Radiol , vol.19 , Issue.6 , pp. 1553-1559
    • Thomas, C.1
  • 48
    • 61349119238 scopus 로고    scopus 로고
    • Image quality optimization and evaluation of linearly mixed images in dual-source, dual-energy CT
    • 19378762 10.1118/1.3077921
    • Yu L, et al. (2009) Image quality optimization and evaluation of linearly mixed images in dual-source, dual-energy CT. Med Phys 36(3):1019-1024
    • (2009) Med Phys , vol.36 , Issue.3 , pp. 1019-1024
    • Yu, L.1
  • 49
    • 79955782136 scopus 로고    scopus 로고
    • Relative dose in dual energy fast-kVp switching and conventional kVp imaging: Spatial frequency dependent noise characteristics and low contrast imaging
    • Pelc NJ, Samei E, Nishikawa RM (eds)
    • Yadava GK, Chandra N, Hsieh J (2011) Relative dose in dual energy fast-kVp switching and conventional kVp imaging: spatial frequency dependent noise characteristics and low contrast imaging. In: Pelc NJ, Samei E, Nishikawa RM (eds) Proceedings of SPIE: Medical Imaging, vol 7961, pp 79613R-1-7
    • (2011) Proceedings of SPIE: Medical Imaging , vol.7961
    • Yadava, G.K.1    Chandra, N.2    Hsieh, J.3
  • 50
    • 84872683938 scopus 로고    scopus 로고
    • Decreased radiation dose in abdominal-pelvic MDCT using dual source dual energy imaging: Quantitative comparison in 84 patients
    • Vancouver, CA
    • Ng J, Chandarana H, Megibow AJ (2012) Decreased radiation dose in abdominal-pelvic MDCT using dual source dual energy imaging: quantitative comparison in 84 patients. To be presented at 2012 American Roentegen Ray Society Annual Meeting, Vancouver, CA
    • (2012) To Be Presented at 2012 American Roentegen Ray Society Annual Meeting
    • Ng, J.1    Chandarana, H.2    Megibow, A.J.3
  • 51
    • 69949096664 scopus 로고    scopus 로고
    • Iterative reconstruction technique for reducing body radiation dose at CT: Feasibility study
    • 19696291 10.2214/AJR.09.2397
    • Hara AK, et al. (2009) Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. AJR Am J Roentgenol 193(3):764-771
    • (2009) AJR Am J Roentgenol , vol.193 , Issue.3 , pp. 764-771
    • Hara, A.K.1
  • 52
    • 79960687077 scopus 로고    scopus 로고
    • Iterative reconstruction algorithm for abdominal multidetector CT at different tube voltages: Assessment of diagnostic accuracy, image quality, and radiation dose in a phantom study
    • 21493795 10.1148/radiol.11102217
    • Schindera ST, et al. (2011) Iterative reconstruction algorithm for abdominal multidetector CT at different tube voltages: assessment of diagnostic accuracy, image quality, and radiation dose in a phantom study. Radiology 260(2):454-462
    • (2011) Radiology , vol.260 , Issue.2 , pp. 454-462
    • Schindera, S.T.1
  • 53
    • 80052413965 scopus 로고    scopus 로고
    • Noise reduction in spectral CT: Reducing dose and breaking the trade-off between image noise and energy bin selection
    • 21978039 10.1118/1.3609097
    • Leng S, et al. (2011) Noise reduction in spectral CT: reducing dose and breaking the trade-off between image noise and energy bin selection. Med Phys 38(9):4946-4957
    • (2011) Med Phys , vol.38 , Issue.9 , pp. 4946-4957
    • Leng, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.