메뉴 건너뛰기




Volumn 15, Issue 1, 2013, Pages 9-15

A high-speed, high-performance on-chip integrated reverse transcription (RT)-microchip

Author keywords

cDNA synthesis; Lateral magnetophoresis; Magnetic oligo dT beads; RNA extraction; RT microchip

Indexed keywords

CDNA SYNTHESIS; MAGNETIC OLIGO-DT BEADS; MAGNETOPHORESIS; RNA EXTRACTION; RT-MICROCHIP;

EID: 84872621564     PISSN: 13872176     EISSN: 15728781     Source Type: Journal    
DOI: 10.1007/s10544-012-9682-3     Document Type: Article
Times cited : (5)

References (18)
  • 3
    • 34248663955 scopus 로고    scopus 로고
    • 10.1038/nprot.2006.83
    • P. Chomczynski, N. Sacchi, The single-step method of RNA isolation by acid guanidinium thiocyanate-phenol-chloroform extraction: twenty-something years on. Nat. Protoc. 1, 581-585 (2006)
    • (2006) Nat. Protoc. , vol.1 , pp. 581-585
    • Chomczynski, P.1    Sacchi, N.2
  • 6
    • 79952264969 scopus 로고    scopus 로고
    • 10.1039/c0lc00136h
    • K.A. Hagan, C.R. Reedy, M.L. Uchimoto, D. Basu, D.A. Engel, J.P. Landers, An integrated, valveless system for microfluidic purification and reverse transcription-PCR amplification of RNA for detection of infectious agents. Lab Chip 11, 957-961 (2011)
    • (2011) Lab Chip , vol.11 , pp. 957-961
    • Hagan, K.A.1    Reedy, C.R.2    Uchimoto, M.L.3    Basu, D.4    Engel, D.A.5    Landers, J.P.6
  • 8
    • 1842424988 scopus 로고    scopus 로고
    • A nanoliter-scale nucleic acid processor with parallel architecture
    • DOI 10.1038/nbt951
    • J.W. Hong, V. Studer, G. Hang, W.F. Anderson, S.R. Quake, A nanoliter-scale nucleic acid processor with parallel architecture. Nat. Biotechnol. 22, 435-439 (2004) (Pubitemid 38451374)
    • (2004) Nature Biotechnology , vol.22 , Issue.4 , pp. 435-439
    • Hong, J.W.1    Studer, V.2    Hang, G.3    Anderson, W.F.4    Quake, S.R.5
  • 9
    • 19144368234 scopus 로고    scopus 로고
    • Continuous microfluidic immunomagnetic cell separation
    • DOI 10.1063/1.1823015
    • D.W. Inglis, R. Riehn, R.H. Austin, J.C. Sturm, Continuous microfluidic immunomagnetic cell separation. Appl. Phys. Lett. 85, 5093-5095 (2004) (Pubitemid 40715225)
    • (2004) Applied Physics Letters , vol.85 , Issue.21 , pp. 5093-5095
    • Inglis, D.W.1    Riehn, R.2    Austin, R.H.3    Sturm, J.C.4
  • 10
    • 0043032926 scopus 로고    scopus 로고
    • Messenger RNA profiling: A prototype method to supplant conventional methods for body fluid identification
    • DOI 10.1016/S0379-0738(03)00197-X
    • J. Juusola, J. Ballantyne, Messenger RNA profiling: a prototype method to supplant conventional methods for body fluid identification. Forensic Sci. Int. 135, 85-96 (2003) (Pubitemid 36960213)
    • (2003) Forensic Science International , vol.135 , Issue.2 , pp. 85-96
    • Juusola, J.1    Ballantyne, J.2
  • 11
    • 77957681829 scopus 로고    scopus 로고
    • 10.1039/c005145d
    • H. Lee, J. Jung, S.-I. Han, K.-H. Han, High-speed RNA microextraction technology using magnetic oligo-dT beads and lateral magnetophoresis. Lab on a Chip 10, 2764-2770 (2010)
    • (2010) Lab on A Chip , vol.10 , pp. 2764-2770
    • Lee, H.1    Jung, J.2    Han, S.-I.3    Han, K.-H.4
  • 12
    • 28544441179 scopus 로고    scopus 로고
    • Miniature RT-PCR system for diagnosis of RNA-based viruses
    • DOI 10.1093/nar/gni157
    • C.-S. Liao, G.-B. Lee, H.-S. Liu, T.-M. Hsieh, C.-H. Luo, Miniature RT-PCR system for diagnosis of RNA-based viruses. Nucleic Acids Res. 33, e156 (2005) (Pubitemid 41742632)
    • (2005) Nucleic Acids Research , vol.33 , Issue.18 , pp. 1-7
    • Liao, C.-S.1    Lee, G.-B.2    Liu, H.-S.3    Hsieh, T.-M.4    Luo, C.-H.5
  • 14
    • 33646575914 scopus 로고    scopus 로고
    • Microfluidic single-cell mRNA isolation and analysis
    • DOI 10.1021/ac0519460
    • J.S. Marcus, W.F. Anderson, S.R. Quake, Microfluidic single-cell mRNA isolation and analysis. Anal. Chem. 78, 3084-3089 (2006a) (Pubitemid 43726129)
    • (2006) Analytical Chemistry , vol.78 , Issue.9 , pp. 3084-3089
    • Marcus, J.S.1    Anderson, W.F.2    Quake, S.R.3
  • 15
    • 32444435330 scopus 로고    scopus 로고
    • Parallel picoliter RT-PCR assays using microfluidics
    • DOI 10.1021/ac0513865
    • J.S. Marcus, W.F. Anderson, S.R. Quake, Parallel picoliter RT-PCR assays using microfluidics. Anal. Chem. 78, 956-958 (2006b) (Pubitemid 43228605)
    • (2006) Analytical Chemistry , vol.78 , Issue.3 , pp. 956-958
    • Marcus, J.S.1    Anderson, W.F.2    Quake, S.R.3
  • 17
    • 41149116231 scopus 로고    scopus 로고
    • Recovery and stability of RNA in vaginal swabs and blood, semen, and saliva stains
    • DOI 10.1111/j.1556-4029.2007.00652.x
    • M. Setzer, J. Juusola, J. Ballantyne, Recovery and stability of RNA in vaginal swabs and blood, semen, and saliva stains. J. Forensic Sci. 53, 296-305 (2008) (Pubitemid 351432610)
    • (2008) Journal of Forensic Sciences , vol.53 , Issue.2 , pp. 296-305
    • Setzer, M.1    Juusola, J.2    Ballantyne, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.