메뉴 건너뛰기




Volumn 176, Issue , 2013, Pages 110-117

Fullerene-C60 sensor for ultra-high sensitive detection of bisphenol-A and its treatment by green technology

Author keywords

Bisphenol A (BPA); Endocrine disruptor; Green technology

Indexed keywords

CHARGE TRANSFER; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; ELECTRODES; ENVIRONMENTAL TECHNOLOGY; FULLERENES; PHENOLS; SCANNING ELECTRON MICROSCOPY; WATER POLLUTION; WATER QUALITY;

EID: 84872559460     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2012.08.081     Document Type: Article
Times cited : (117)

References (78)
  • 1
    • 84890486529 scopus 로고    scopus 로고
    • Long-term effects of environmental endocrine disruptors on reproductive physiology and behavior
    • H.B. Patisaul, H.B. Adewale, Long-term effects of environmental endocrine disruptors on reproductive physiology and behavior, Frontiers in Behavioral Neuroscience 3 (2009) 10-18.
    • (2009) Frontiers in Behavioral Neuroscience , vol.3 , pp. 10-18
    • Patisaul, H.B.1    Adewale, H.B.2
  • 2
    • 0027222826 scopus 로고
    • Bisphenol-A: An estrogenic substance is released from polycarbonate flasks during autoclaving
    • DOI 10.1210/en.132.6.2279
    • A. Krishnan, P. Stathis, S. Permuth, L. Tokes, D. Feldman, Bisphenol-A: an estrogenic substance is released from polycarbonate flasks during autoclaving, Endocrinology 132 (1993) 2279-2286. (Pubitemid 23156872)
    • (1993) Endocrinology , vol.132 , Issue.6 , pp. 2279-2286
    • Krishnan, A.V.1    Stathis, P.2    Permuth, S.F.3    Tokes, L.4    Feldman, D.5
  • 3
    • 52949091594 scopus 로고    scopus 로고
    • Effects of developmental exposure to bisphenol A on brain and behavior in mice
    • P. Palanzaa, L. Gioiosaa, F.S. vom Saalb, S. Parmigiania, Effects of developmental exposure to bisphenol A on brain and behavior in mice, Environmental Research 108 (2008) 150-157.
    • (2008) Environmental Research , vol.108 , pp. 150-157
    • Palanzaa, P.1    Gioiosaa, L.2    Vom Saalb, F.S.3    Parmigiania, S.4
  • 4
    • 0038680428 scopus 로고    scopus 로고
    • Evaluation of the immune response following exposure of mice to bisphenol A: Induction of Th1 cytokine and prolactin by BPA exposure in the mouse spleen cells
    • J.Y. Youn, H.Y. Park, J.W. Lee, I.O. Jung, K.H. Choi, K. Kim, K.H. Cho, Evaluation of the immune response following exposure of mice to bisphenol A: induction of th1 cytokine and prolactin by BPA exposure in the mouse spleen cells, Archives of Pharmacal Research 25 (2002) 946-953. (Pubitemid 43066590)
    • (2002) Archives of Pharmacal Research , vol.25 , Issue.6 , pp. 946-953
    • Youn, J.-Y.1    Park, H.-Y.2    Lee, J.-W.3    Jung, I.-O.4    Choi, K.-H.5    Kim, K.6    Cho, K.-H.7
  • 5
    • 0042613703 scopus 로고    scopus 로고
    • Input/output balance of estrogenic active compounds in a major municipal sewage plant in Germany
    • DOI 10.1016/S0045-6535(99)00362-8, PII S0045653599003628
    • W. Korner, U. Bolz, W. Sumuth, Input/output balance of estrogenic active compounds in a major municipal sewage plant in Germany, Chemosphere 40 (2000) 1131-1142. (Pubitemid 30120722)
    • (2000) Chemosphere , vol.40 , Issue.9-11 , pp. 1131-1142
    • Korner, W.1    Bolz, U.2    Sussmuth, W.3    Hiller, G.4    Schuller, W.5    Hanf, V.6    Hagenmaier, H.7
  • 6
    • 0141831173 scopus 로고    scopus 로고
    • Occurrence and removal of endocrine disrupters in landfill leachate treatment plants
    • T. Wintgens, M. Gallenkemper, T. Melin, Occurrence and removal of endocrine disrupters in landfill leachate treatment plants, Water Science and Technology 48 (2003) 1234-1277.
    • (2003) Water Science and Technology , vol.48 , pp. 1234-1277
    • Wintgens, T.1    Gallenkemper, M.2    Melin, T.3
  • 8
    • 33846317845 scopus 로고    scopus 로고
    • Electrochemical oxidation of organic pollutants for the wastewater treatment: Direct and indirect processes
    • C.A. Martínez-Huitle, S. Ferro, Electrochemical oxidation of organic pollutants for the wastewater treatment: direct and indirect processes, Chemical Society Reviews 35 (2006) 13247-21340.
    • (2006) Chemical Society Reviews , vol.35 , pp. 13247-21340
    • Martínez-Huitle, C.A.1    Ferro, S.2
  • 10
    • 0036434262 scopus 로고    scopus 로고
    • Molecular imprinting of bisphenol A and alkylphenols using amylose as a host matrix
    • Y. Kanekiyo, R. Naganawa, H. Tao, Molecular imprinting of bisphenol using amylose as a host matrix, Chemical Communications 2002 (2002) 2698-2699. (Pubitemid 35351972)
    • (2002) Chemical Communications , Issue.22 , pp. 2698-2699
    • Kanekiyo, Y.1    Naganawa, R.2    Tao, H.3
  • 11
    • 0002769297 scopus 로고
    • Caesium PVC-crown (dibenzo-24-crown-8) based membrane sensor, Analytical Proceedings including
    • S.K. Srivastava, V.K. Gupta, M.K. Dwivedi, S. Jain, Caesium PVC-crown (dibenzo-24-crown-8) based membrane sensor, Analytical Proceedings including Analytical Communications 32 (1995) 21-23.
    • (1995) Analytical Communications , vol.32 , pp. 21-23
    • Srivastava, S.K.1    Gupta, V.K.2    Dwivedi, M.K.3    Jain, S.4
  • 12
    • 33745943030 scopus 로고
    • Copper(II)-selective electrodes based on macrocyclic compounds, Analytical Proceedings including
    • A.K. Jain, V.K. Gupta, B.B. Sahoo, L.P. Singh, Copper(II)-selective electrodes based on macrocyclic compounds, Analytical Proceedings including Analytical Communications 32 (1995) 99-101.
    • (1995) Analytical Communications , vol.32 , pp. 99-101
    • Jain, A.K.1    Gupta, V.K.2    Sahoo, B.B.3    Singh, L.P.4
  • 14
    • 67649378642 scopus 로고    scopus 로고
    • Comparative studies of neodymium (III)- selective PVC membrane sensors
    • V.K. Gupta, R.N. Goyal, R.A. Sharma, Comparative studies of neodymium (III)- selective PVC membrane sensors, Analytica Chimica Acta 647 (2009) 66-71.
    • (2009) Analytica Chimica Acta , vol.647 , pp. 66-71
    • Gupta, V.K.1    Goyal, R.N.2    Sharma, R.A.3
  • 15
    • 0030668846 scopus 로고    scopus 로고
    • Porphyrins as carrier in PVC based membrane potentiometric sensors for nickel(II)
    • DOI 10.1016/S0003-2670(97)81609-1, PII S0003267097004819
    • V.K. Gupta, A.K. Jain, L.P. Singh, U. Khurana, Porphyrins as carrier in PVC based membrane potentiometric sensors for nickel (II), Analytica Chimica Acta 355 (1997) 33-41. (Pubitemid 27528807)
    • (1997) Analytica Chimica Acta , vol.355 , Issue.1 , pp. 33-41
    • Gupta, V.K.1    Jain, A.K.2    Singh, L.P.3    Khurana, U.4
  • 16
    • 0001498689 scopus 로고    scopus 로고
    • A PVC-Based Benzo-15-Crown-5 Membrane Sensor for Cadmium
    • S.K. Srivastava, V.K. Gupta, S. Jain, A PVC-based benzo-15-crown-5 membrane sensor for cadmium, Electroanalysis 10 (1996) 938-940. (Pubitemid 126419469)
    • (1996) Electroanalysis , vol.8 , Issue.10 , pp. 938-940
    • Srivastava, S.K.1    Gupta, V.K.2    Jain, S.3
  • 17
    • 33846178200 scopus 로고    scopus 로고
    • Schiff bases as cadmium(II) selective ionophores in polymeric membrane electrodes
    • DOI 10.1016/j.aca.2006.10.039, PII S0003267006021167
    • V.K. Gupta, A.K. Singh, B. Gupta, Schiff bases as cadmium(II) selective ionophores in polymeric membrane electrodes, Analytica Chimica Acta 583 (2007) 340-348. (Pubitemid 46080373)
    • (2007) Analytica Chimica Acta , vol.583 , Issue.2 , pp. 340-348
    • Gupta, V.K.1    Singh, A.K.2    Gupta, B.3
  • 18
    • 29244459114 scopus 로고    scopus 로고
    • Chromium(III)-selective sensor based on tri-o-thymotide in PVC matrix
    • DOI 10.1016/j.snb.2005.02.046, PII S0925400505002297
    • V.K. Gupta, A.K. Jain, P. Kumar, S. Agarwal, G. Maheshwari, Chromium(III)- selective sensor based on tri-o-thymotide in PVC matrix, Sensors and Actuators B-Chemical 113 (2006) 182-186. (Pubitemid 41831285)
    • (2006) Sensors and Actuators, B: Chemical , vol.113 , Issue.1 , pp. 182-186
    • Gupta, V.K.1    Jain, A.K.2    Kumar, P.3    Agarwal, S.4    Maheshwari, G.5
  • 19
    • 44949166393 scopus 로고    scopus 로고
    • Simultaneous determination of adenosine and inosine using single-wall carbon nanotubes modified pyrolytic graphite electrode
    • R.N. Goal, V.K. Gupta, S. Chatterjee, Simultaneous determination of adenosine and inosine using single-wall carbon nanotubes modified pyrolytic graphite electrode, Talanta 76 (2008) 663-669.
    • (2008) Talanta , vol.76 , pp. 663-669
    • Goal, R.N.1    Gupta, V.K.2    Chatterjee, S.3
  • 20
    • 43049142679 scopus 로고    scopus 로고
    • Electrochemical oxidation of 2',3'- dideoxyadenosine at pyrolytic graphite electrode
    • R.N. Goal, V.K. Gupta, S. Chatterjee, Electrochemical oxidation of 2',3'- dideoxyadenosine at pyrolytic graphite electrode, Electrochimica Acta 53 (2008) 5354-5360.
    • (2008) Electrochimica Acta , vol.53 , pp. 5354-5360
    • Goal, R.N.1    Gupta, V.K.2    Chatterjee, S.3
  • 21
    • 22544475031 scopus 로고    scopus 로고
    • Differential pulse voltammetric determination of paracetamol at nanogold modified indium tin oxide electrode
    • DOI 10.1016/j.elecom.2005.05.005, PII S138824810500144X
    • R.N. Goyal, V.K. Gupta, M. Oyama, N. Bachheti, Differential pulse volammetric determination of paracetamol at nanogold modified indium tin oxide (ITO) electrode, Electrochemistry Communications 7 (2005) 803-807. (Pubitemid 41014095)
    • (2005) Electrochemistry Communications , vol.7 , Issue.8 , pp. 803-807
    • Goyal, R.N.1    Gupta, V.K.2    Oyama, M.3    Bachheti, N.4
  • 22
  • 23
    • 77955473978 scopus 로고    scopus 로고
    • Voltammetric biosensors for the determination of paracetamol at carbon nanotube modified pyrolytic graphite electrode
    • R.N. Goyal, Vinod K. Gupta, S. Chatterjee, Voltammetric biosensors for the determination of paracetamol at carbon nanotube modified pyrolytic graphite electrode, Sensors and Actuators B-Chemical 149 (2011) 252-258.
    • (2011) Sensors and Actuators B-Chemical , vol.149 , pp. 252-258
    • Goyal, R.N.1    Vinod, K.2    Chatterjee, G.S.3
  • 24
    • 0036712887 scopus 로고    scopus 로고
    • Pb (II) selective potentiometric sensor based on 4-tert-butylcalix [4] arene in PVC matrix
    • V.K. Gupta, R. Mangla, S. Agarwal, Pb (II) selective potentiometric sensor based on 4-tert-butylcalix[4] arene in PVC matrix, Electroanalysis 14 (2002) 1127-1132.
    • (2002) Electroanalysis , vol.14 , pp. 1127-1132
    • Gupta, V.K.1    Mangla, R.2    Agarwal, S.3
  • 25
    • 0000907699 scopus 로고    scopus 로고
    • 2 Ions Based on 2-Hydroxyacetophenoneoxime-thiourea-trioxane Resin
    • A.K. Jain, V.K. Gupta, U. Khurana, Lok P. Singh, A new membrane sensor for UO2 2+ ions based on 2-hydroxyacetophenoneoxime-thiourea-trioxane resin, Electroanalysis 9 (1997) 857-860. (Pubitemid 127441313)
    • (1997) Electroanalysis , vol.9 , Issue.11 , pp. 857-860
    • Jain, A.K.1    Gupta, V.K.2    Khurana, U.3    Singh, L.P.4
  • 26
    • 70149111748 scopus 로고    scopus 로고
    • Novel PVC membrane based alizarin sensor and its application; Determination of vanadium, zirconium and molybdenum
    • V.K. Gupta, R.N. Goyal, R.A. Sharma, Novel PVC membrane based alizarin sensor and its application; determination of vanadium, zirconium and molybdenum, International Journal of Electrochemical Science 4 (2009) 156-172.
    • (2009) International Journal of Electrochemical Science , vol.4 , pp. 156-172
    • Gupta, V.K.1    Goyal, R.N.2    Sharma, R.A.3
  • 27
    • 29344460239 scopus 로고    scopus 로고
    • Differential pulse voltammetric determination of atenolol in pharmaceutical formulations and urine using nanogold modified indium tin oxide electrode
    • DOI 10.1016/j.elecom.2005.10.011, PII S1388248105003103
    • R.N. Goyal, V.K. Gupta, M. Oyama, N. Bachheti, Differential pulse voltammetric determination of atenolol in pharmaceutical formulations and urine using nanogold modified indium tin oxide electrode, Electrochemistry Communications 8 (2006) 65-70. (Pubitemid 43006161)
    • (2006) Electrochemistry Communications , vol.8 , Issue.1 , pp. 65-70
    • Goyal, R.N.1    Gupta, V.K.2    Oyama, M.3    Bachheti, N.4
  • 28
    • 67650045961 scopus 로고    scopus 로고
    • A sensitive voltammetric sensor for determination of synthetic corticosteroid triamcinolone abused for doping
    • R.N. Goyal, V.K. Gupta, S. Chatterjee, A sensitive voltammetric sensor for determination of synthetic corticosteroid triamcinolone, abused for doping, Biosensors and Bioelectronics (2009) 3562-3568.
    • (2009) Biosensors and Bioelectronics , pp. 3562-3568
    • Goyal, R.N.1    Gupta, V.K.2    Chatterjee, S.3
  • 29
    • 34247344425 scopus 로고    scopus 로고
    • Gold nanoparticles modified indium tin oxide electrode for the simultaneous determination of dopamine and serotonin: Application in pharmaceutical formulations and biological fluids
    • DOI 10.1016/j.talanta.2006.12.029, PII S0039914006008368
    • R.N. Goyal, V.K. Gupta, M. Oyama, N. Bachheti, Gold nanoparticles modified indium tin oxide electrode for the simultaneous determination of dopamine and serotonin: application in pharmaceutical formulations and biological fluids, Talanta 72 (2007) 976-983. (Pubitemid 46635556)
    • (2007) Talanta , vol.72 , Issue.3 , pp. 976-983
    • Goyal, R.N.1    Gupta, V.K.2    Oyama, M.3    Bachheti, N.4
  • 30
    • 0030980259 scopus 로고    scopus 로고
    • Macrocycle based membrane sensors for the determination of cobalt(II) ions
    • DOI 10.1039/a608421d
    • A.K. Jain, V.K. Gupta, L.P. Singh, U. Khurana, Macrocycle based membrane sensors for the determination of cobalt(II) ions, Analyst 122 (1997) 583-586. (Pubitemid 27277829)
    • (1997) Analyst , vol.122 , Issue.6 , pp. 583-586
    • Jain, A.K.1    Gupta, V.K.2    Singh, L.P.3    Khurana, U.4
  • 31
    • 58149505714 scopus 로고    scopus 로고
    • Nano level detection of Cd(II) using poly(vinyl chloride) based membranes of Schiff bases
    • V.K. Gupta, M.A. Khayat, A.K. Singh, M.K. Pal, Nano level detection of Cd(II) using poly(vinyl chloride) based membranes of Schiff bases, Analytica Chimica Acta 634 (2009) 36-43.
    • (2009) Analytica Chimica Acta , vol.634 , pp. 36-43
    • Gupta, V.K.1    Khayat, M.A.2    Singh, A.K.3    Pal, M.K.4
  • 32
    • 51649100721 scopus 로고    scopus 로고
    • Sensors for 5- hydroxytryptamine and 5-hydroxyindole acetic acid based on nanomaterial modified electrodes
    • R.N. Goyal, M. Oyama, V.K. Gupta, S.P. Singh, R.A. Sharma, Sensors for 5- hydroxytryptamine and 5-hydroxyindole acetic acid based on nanomaterial modified electrodes, Sensors and Actuators, B 134 (2008) 816-821.
    • (2008) Sensors and Actuators B , vol.134 , pp. 816-821
    • Goyal, R.N.1    Oyama, M.2    Gupta, V.K.3    Singh, S.P.4    Sharma, R.A.5
  • 33
    • 61949143409 scopus 로고    scopus 로고
    • Mesoporous silica-based electrochemical sensor for sensitive determination of environmental hormone bisphenol A
    • F. Wang, J. Yang, K. Wu, Mesoporous silica-based electrochemical sensor for sensitive determination of environmental hormone bisphenol A, Analytica Chimica Acta 638 (2009) 23-28.
    • (2009) Analytica Chimica Acta , vol.638 , pp. 23-28
    • Wang, F.1    Yang, J.2    Wu, K.3
  • 34
    • 0038715138 scopus 로고    scopus 로고
    • Electrocatalytic properties and sensor applications of fullerenes and carbon nanotubes
    • B. Sherigara, W. Kutner, F. D'Souza, Electrocatalytic properties and sensor applications of fullerenes and carbon nanotubes, Electroanalysis 15 (2003) 753-772.
    • (2003) Electroanalysis , vol.15 , pp. 753-772
    • Sherigara, B.1    Kutner, W.2    D'Souza, F.3
  • 35
    • 0035793192 scopus 로고    scopus 로고
    • Electrochemical reactions of cytochrome c on electrodes modified by fullerene films
    • DOI 10.1016/S0022-0728(00)00453-8
    • M. Csiszar, A. Szucs, M. Tolgyesi, A. Mechler, J.B. Nagy, M. Novak, Electrochemical reactions of cytochrome c on electrodes modified by fullerene films, Journal of Electroanalytical Chemistry 497 (2001) 69-74. (Pubitemid 32139115)
    • (2001) Journal of Electroanalytical Chemistry , vol.497 , Issue.1-2 , pp. 69-74
    • Csiszar, M.1    Szucs, A.2    Tolgyesi, M.3    Mechler, A.4    Nagy, J.B.5    Novak, M.6
  • 36
    • 0001567948 scopus 로고
    • Fullerene film electrodes in aqueous solutions and electrochemical characterization
    • A. Szucs, A. Loix, J.B. Nagy, L. Lamberts, Fullerene film electrodes in aqueous solutions and electrochemical characterization, Journal of Electroanalytical Chemistry 397 (1995) 191-203.
    • (1995) Journal of Electroanalytical Chemistry , vol.397 , pp. 191-203
    • Szucs, A.1    Loix, A.2    Nagy, J.B.3    Lamberts, L.4
  • 38
    • 0030086279 scopus 로고    scopus 로고
    • Fullerene film electrodes in aqueous solutions
    • DOI 10.1016/0379-6779(96)80093-2
    • A. Szucs, A. Loix, J.B. Nagy, L. Lamberts, Fullerene film electrodes in aqueous solutions, Synthetic Metals 77 (1996) 227-230. (Pubitemid 126341323)
    • (1996) Synthetic Metals , vol.77 , Issue.1-3 , pp. 227-230
    • Szucs, A.1    Loix, A.2    Nagy, J.B.3    Lamberts, L.4
  • 41
    • 52149119220 scopus 로고    scopus 로고
    • Electrochemical sensor for the determination of dopamine in presence of high concentration of ascorbic acid using a fullerene-C60 coated gold electrode
    • R.N. Goyal, V.K. Gupta, N. Bachheti, R.A. Sharma, Electrochemical sensor for the determination of dopamine in presence of high concentration of ascorbic acid using a fullerene-C60 coated gold electrode, Electroanalysis 20 (2008) 757-764.
    • (2008) Electroanalysis , vol.20 , pp. 757-764
    • Goyal, R.N.1    Gupta, V.K.2    Bachheti, N.3    Sharma, R.A.4
  • 42
    • 77953608358 scopus 로고    scopus 로고
    • Simultaneous determination of adenosine and inosine using single-wall carbon nanotubes modified pyrolytic graphite electrode
    • R.N. Goyal, D. Kaur, S.P. Singh, A.K. Pandey, Simultaneous determination of adenosine and inosine using single-wall carbon nanotubes modified pyrolytic graphite electrode, Talanta 75 (2008) 663-669.
    • (2008) Talanta , vol.75 , pp. 663-669
    • Goyal, R.N.1    Kaur, D.2    Singh, S.P.3    Pandey, A.K.4
  • 43
    • 17044439457 scopus 로고    scopus 로고
    • Immobilization and electrochemical redox behavior of cytochrome c on fullerene film-modified electrodes
    • F. D'Souza, L.M. Rogers, E.S. O'Dell, A. Kochman, W. Kutner, Immobilization and electrochemical redox behavior of cytochrome c on fullerene film-modified electrodes, Bioelectrochemistry 66 (2005) 35-40.
    • (2005) Bioelectrochemistry , vol.66 , pp. 35-40
    • D'Souza, F.1    Rogers, L.M.2    O'Dell, E.S.3    Kochman, A.4    Kutner, W.5
  • 44
    • 33646553573 scopus 로고    scopus 로고
    • 60-modified glassy carbon electrodes
    • DOI 10.1016/j.talanta.2005.11.041, PII S0039914005007691
    • R.N. Goyal, S.P. Singh, Voltammetric determination of atenolol at C60-modified glassy carbon electrodes, Talanta 69 (2006) 932-937. (Pubitemid 43729913)
    • (2006) Talanta , vol.69 , Issue.4 , pp. 932-937
    • Goyal, R.N.1    Singh, S.P.2
  • 45
    • 0038715138 scopus 로고    scopus 로고
    • Electrocatalytic properties and sensor applications of fullerenes and carbon nanotubes
    • B.S. Sherigara, W. Kutner, F. D'Souza, Electrocatalytic properties and sensor applications of fullerenes and carbon nanotubes, Electroanalysis 15 (2003) 753-772.
    • (2003) Electroanalysis , vol.15 , pp. 753-772
    • Sherigara, B.S.1    Kutner, W.2    D'Souza, F.3
  • 46
    • 0142027908 scopus 로고    scopus 로고
    • 60-modified carbon electrode
    • DOI 10.1016/S0003-2670(03)00791-8
    • W.T. Tan, A.M. Bond, S.W. Ngooi, E.B. Lim, J.K. Goh, Electrochemical oxidation of l-cysteine mediated by a fullerene-C60-modified carbon electrode, Analytica Chimica Acta 491 (2003) 181-191. (Pubitemid 37297778)
    • (2003) Analytica Chimica Acta , vol.491 , Issue.2 , pp. 181-191
    • Tan, W.T.1    Bond, A.M.2    Ngooi, S.W.3    Lim, E.B.4    Goh, J.K.5
  • 47
    • 45249089221 scopus 로고    scopus 로고
    • Electrochemical sensing platform based on the highly ordered mesoporous carbon-fullerene system
    • DOI 10.1021/ac702496k
    • M. Zhou, J. Guo, L.P. Guo, J. Bai, Electrochemical sensing platform based on the highly ordered mesoporous carbon-fullerene system, Analytical Chemistry 80 (2008) 4642-4650. (Pubitemid 351842343)
    • (2008) Analytical Chemistry , vol.80 , Issue.12 , pp. 4642-4650
    • Zhou, M.1    Guo, J.2    Guo, L.-P.3    Bai, J.4
  • 48
    • 34447558481 scopus 로고    scopus 로고
    • 60-modified electrode as a sensitive voltammetric sensor for detection of nandrolone-An anabolic steroid used in doping
    • DOI 10.1016/j.aca.2007.06.017, PII S000326700701046X
    • R.N. Goyal, V.K. Gupta, N. Bachheti, Fullerene-C60-modified electrode as a sensitive voltammetric sensor for detection of nandrolone, Analytica Chimica Acta 597 (2007) 82-89. (Pubitemid 47068384)
    • (2007) Analytica Chimica Acta , vol.597 , Issue.1 , pp. 82-89
    • Goyal, R.N.1    Gupta, V.K.2    Bachheti, N.3
  • 49
    • 33846547509 scopus 로고    scopus 로고
    • 60-modified glassy carbon electrode
    • DOI 10.1016/j.talanta.2006.06.002, PII S0039914006004243
    • R.N. Goyal, V.K. Gupta, N. Bachheti, Voltammetric determination of adenosine and guanosine using fullerene-C60-modified glassy carbon electrode, Talanta 71 (2007) 1110-1117. (Pubitemid 46161626)
    • (2007) Talanta , vol.71 , Issue.3 , pp. 1110-1117
    • Goyal, R.N.1    Gupta, V.K.2    Oyama, M.3    Bachheti, N.4
  • 50
    • 29744466352 scopus 로고    scopus 로고
    • Bachheti, Voltammetric determination of uric acid at a fullerene-C60-modified glassy carbon electrode
    • R.N. Goyal, V.K. Gupta, Aditi Sangal, N. Bachheti, Voltammetric determination of uric acid at a fullerene-C60-modified glassy carbon electrode, Electroanalysis 17 (2005) 2217-2223.
    • (2005) Electroanalysis , vol.17 , pp. 2217-2223
    • Goyal, R.N.1    Gupta, V.K.2    Aditi Sangal, N.3
  • 51
    • 65549152984 scopus 로고    scopus 로고
    • Fullerene-C60-modified edge plane pyrolytic graphite electrode for the determination of dexamethasone in pharmaceutical formulations and human biological fluids
    • R.N. Goyal, V.K. Gupta, S. Chatterjee, Fullerene-C60-modified edge plane pyrolytic graphite electrode for the determination of dexamethasone in pharmaceutical formulations and human biological fluids, Biosensors and Bioelectronics 24 (2009) 1649-1654.
    • (2009) Biosensors and Bioelectronics , vol.24 , pp. 1649-1654
    • Goyal, R.N.1    Gupta, V.K.2    Chatterjee, S.3
  • 52
    • 77958523398 scopus 로고    scopus 로고
    • Vikas, Highly sensitive selective voltammetric sensor fullerene modified glassy carbon electrode for determination of cefitizoxime in solubilized system
    • R. Jain, J.A. Rather, A. Dwivedi, Vikas, Highly sensitive selective voltammetric sensor fullerene modified glassy carbon electrode for determination of cefitizoxime in solubilized system, Electroanalysis 22 (2010) 2600-2606.
    • (2010) Electroanalysis , vol.22 , pp. 2600-2606
    • Jain, R.1    Rather, J.A.2    Dwivedi, A.3
  • 53
    • 75249086941 scopus 로고    scopus 로고
    • Nafion/multi-wall carbon nanotubes composite film coated glassy carbon electrode for sensitive determination of caffeine
    • S. Yang, R. Yang, G. Li, L. Qu, J. Li, L. Yu, Nafion/multi-wall carbon nanotubes composite film coated glassy carbon electrode for sensitive determination of caffeine, Journal of Electroanalytical Chemistry 639 (2010) 77-82.
    • (2010) Journal of Electroanalytical Chemistry , vol.639 , pp. 77-82
    • Yang, S.1    Yang, R.2    Li, G.3    Qu, L.4    Li, J.5    Yu, L.6
  • 60
    • 0037133918 scopus 로고    scopus 로고
    • Tyrosinase-modified boron-doped diamond electrodes for the determination of phenol derivatives
    • DOI 10.1016/S0022-0728(02)00733-7, PII S0022072802007337
    • H. Notsu, T. Tatsuma, A. Fujishima, Tyrosinase-modified boron-doped diamond electrodes for the determination of phenol derivatives, Journal of Electroanalytical Chemistry 523 (2002) 86-92. (Pubitemid 34716056)
    • (2002) Journal of Electroanalytical Chemistry , vol.523 , Issue.1-2 , pp. 86-92
    • Notsu, H.1    Tatsuma, T.2    Fujishima, A.3
  • 61
    • 79952061784 scopus 로고    scopus 로고
    • Glucose biosensor based on glucose oxidase immobilized on a nanofilm composed of mesoporous hydroxyapatite titanium dioxide, and modified with multi-walled carbon nanotube
    • J. Li, D. Kuang, Y. Feng, F. Zhang, M. Liu, Glucose biosensor based on glucose oxidase immobilized on a nanofilm composed of mesoporous hydroxyapatite, titanium dioxide, and modified with multi-walled carbon nanotube, Microchimica Acta 172 (2011) 379-386.
    • (2011) Microchimica Acta , vol.172 , pp. 379-386
    • Li, J.1    Kuang, D.2    Feng, Y.3    Zhang, F.4    Liu, M.5
  • 62
    • 0842348792 scopus 로고    scopus 로고
    • Correlation of Analyte Structures with Biosensor Responses Using the Detection of Phenolic Estrogens as a Model
    • DOI 10.1021/ac034480z
    • S. Andreescu, O.A. Sadik, The correlation of analyte structures with biosensor responses using structure-activity relationship: detection of phenolic estrogens as model, Analytical Chemistry 76 (2004) 552-560. (Pubitemid 38166557)
    • (2004) Analytical Chemistry , vol.76 , Issue.3 , pp. 552-560
    • Andreescu, S.1    Sadik, O.A.2
  • 63
    • 4043134375 scopus 로고    scopus 로고
    • Development of a biosensor for endocrine disrupting compounds based on tyrosinase entrapped within a poly(thionine) film
    • DOI 10.1016/j.bios.2004.02.007, PII S0956566304000831
    • E. Dempsey, D. Diamond, A. Collier, Development of a biosensor for endocrine disrupting compounds based on tyrosinase entrapped (H2O2)/(M within a poly(thionine) film, Biosensors and Bioelectronics 20 (2004) 367-377. (Pubitemid 39077642)
    • (2004) Biosensors and Bioelectronics , vol.20 , Issue.2 , pp. 367-377
    • Dempsey, E.1    Diamond, D.2    Collier, A.3
  • 64
    • 79952489212 scopus 로고    scopus 로고
    • Electrocatalytic detection of phenolic estrogenic compounds at NiTPPS|carbon nanotube composite electrodes
    • X. Liu, H. Feng, X. Liu, D.K.Y. Wong, Electrocatalytic detection of phenolic estrogenic compounds at NiTPPS|carbon nanotube composite electrodes, Analytica Chimica Acta 689 (2011) 212-218.
    • (2011) Analytica Chimica Acta , vol.689 , pp. 212-218
    • Liu, X.1    Feng, H.2    Liu, X.3    Wong, D.K.Y.4
  • 65
    • 27844535386 scopus 로고    scopus 로고
    • Voltammetric determination of bisphenol A using a carbon paste electrode based on the enhancement effect of cetyltrimethylammonium bromide (CTAB)
    • W. Huang, Voltammetric determination of bisphenol A using a carbon paste electrode based on the enhancement effect of cetyltrimethylammonium bromide (CTAB), Bulletin of the Korean Chemical Society 26 (2005) 1560.
    • (2005) Bulletin of the Korean Chemical Society , vol.26 , pp. 1560
    • Huang, W.1
  • 67
    • 38949159265 scopus 로고    scopus 로고
    • Voltammetric determination of bisphenol A using an acetylene black-dihexadecyl hydrogen phosphate composite film-modified electrode
    • DOI 10.1080/00032710701672608, PII 790372063
    • W. Huang, C. Yang, Voltammetric determination of bisphenol A using an acetylene black-dihexadecyl hydrogen phosphate composite film-modified electrode, Analytical Letters 40 (2007) 3280-3289. (Pubitemid 351214971)
    • (2007) Analytical Letters , vol.40 , Issue.17 , pp. 3280-3289
    • Huang, W.1    Yang, C.2
  • 68
    • 33846513973 scopus 로고    scopus 로고
    • Electrochemical detection of phenolic estrogenic compounds at carbon nanotube-modified electrodes
    • DOI 10.1016/j.talanta.2006.05.071, PII S0039914006004000
    • D. Vega, L. Agüí, A. González-Cortés, P. Yá?nez-Sede?no, J.M. Pingarrón, Electrochemical detection of phenolic estrogenic compounds at carbon nanotube-modified electrodes, Talanta 71 (2007) 1031-1038. (Pubitemid 46161613)
    • (2007) Talanta , vol.71 , Issue.3 , pp. 1031-1038
    • Vega, D.1    Agui, L.2    Gonzalez-Cortes, A.3    Yanez-Sedeno, P.4    Pingarron, J.M.5
  • 69
    • 71449117924 scopus 로고    scopus 로고
    • Electroanalysis of bisphenol A at a multiwalled carbon nanotubes-gold nanoparticles modified glassy carbon electrode
    • X. Tu, L. Yan, X. Luo, S. Luo, Q. Xie, Electroanalysis of bisphenol A at a multiwalled carbon nanotubes-gold nanoparticles modified glassy carbon electrode, Electroanalysis 21 (2009) 2491-2494.
    • (2009) Electroanalysis , vol.21 , pp. 2491-2494
    • Tu, X.1    Yan, L.2    Luo, X.3    Luo, S.4    Xie, Q.5
  • 70
    • 61949143409 scopus 로고    scopus 로고
    • Mesoporous silica-based electrochemical sensor for sensitive determination of environmental hormone bisphenol A
    • F. Wang, J. Yang, K. Wu, Mesoporous silica-based electrochemical sensor for sensitive determination of environmental hormone bisphenol A, Analytica Chimica Acta 638 (2009) 2328-2333.
    • (2009) Analytica Chimica Acta , vol.638 , pp. 2328-2333
    • Wang, F.1    Yang, J.2    Wu, K.3
  • 71
    • 58749093191 scopus 로고    scopus 로고
    • Preparation and characteristic of cobalt phthalocyanine modified carbon paste electrode for bisphenol A detection
    • H. Yin, Y. Zhou, S. Ai, Preparation and characteristic of cobalt phthalocyanine modified carbon paste electrode for bisphenol A detection, Journal of Electroanalytical Chemistry 626 (2009) 80-88.
    • (2009) Journal of Electroanalytical Chemistry , vol.626 , pp. 80-88
    • Yin, H.1    Zhou, Y.2    Ai, S.3
  • 72
    • 70549093022 scopus 로고    scopus 로고
    • Electrochemical determination of bisphenol A at Mg-Al-CO3 layered double hydroxide modified glassy carbon electrode
    • H. Yin, L. Cui, S. Ai, H. Fan, L. Zhou, Electrochemical determination of bisphenol A at Mg-Al-CO3 layered double hydroxide modified glassy carbon electrode, Electrochimica Acta 55 (2010) 603-610.
    • (2010) Electrochimica Acta , vol.55 , pp. 603-610
    • Yin, H.1    Cui, L.2    Ai, S.3    Fan, H.4    Zhou, L.5
  • 73
    • 83155172355 scopus 로고    scopus 로고
    • Electrochemical sensor for bisphenol A detection based on molecularly imprinted polymers and gold nanoparticles
    • J. Huang, X. Zhang, S. Liu, Q. Lin, X. He, X. Xing, H. Huai, W. Lian, Electrochemical sensor for bisphenol A detection based on molecularly imprinted polymers and gold nanoparticles, Journal of Applied Electrochemistry 41 (2011) 1323-1328.
    • (2011) Journal of Applied Electrochemistry , vol.41 , pp. 1323-1328
    • Huang, J.1    Zhang, X.2    Liu, S.3    Lin, Q.4    He, X.5    Xing, X.6    Huai, H.7    Lian, W.8
  • 74
    • 80955178853 scopus 로고    scopus 로고
    • Electroanalysis of bisphenol A at a multiwalled carbon nanotubes-gold nanoparticles modified glassy carbon electrode
    • J. Ren, T. Kang, R. Xue, C. Ge, S. Cheng, Electroanalysis of bisphenol A at a multiwalled carbon nanotubes-gold nanoparticles modified glassy carbon electrode, Microchimica Acta 174 (2011) 303-309.
    • (2011) Microchimica Acta , vol.174 , pp. 303-309
    • Ren, J.1    Kang, T.2    Xue, R.3    Ge, C.4    Cheng, S.5
  • 75
    • 78149411692 scopus 로고    scopus 로고
    • Amperometric determination of bisphenol A in milk using PAMAM-Fe2O4 modified glassy carbon electrode
    • H. Yin, L. Cui, Q. Chen, W. Shi, S. Ai, L. Zhu, L. Lu, Amperometric determination of bisphenol A in milk using PAMAM-Fe2O4 modified glassy carbon electrode, Food Chemistry 125 (2011) 1097-1103.
    • (2011) Food Chemistry , vol.125 , pp. 1097-1103
    • Yin, H.1    Cui, L.2    Chen, Q.3    Shi, W.4    Ai, S.5    Zhu, L.6    Lu, L.7
  • 76
    • 80053269508 scopus 로고    scopus 로고
    • Chitosan-Fe3O4 nanocomposite based electrochemical sensors for the determination of bisphenol A
    • C. Yu, L. Gou, X. Zhou, N. Bao, H. Gu, Chitosan-Fe3O4 nanocomposite based electrochemical sensors for the determination of bisphenol A, Electrochimica Acta 56 (2011) 9056-9063.
    • (2011) Electrochimica Acta , vol.56 , pp. 9056-9063
    • Yu, C.1    Gou, L.2    Zhou, X.3    Bao, N.4    Gu, H.5
  • 78
    • 84864276703 scopus 로고    scopus 로고
    • Electrochemical sensor for bisphenol A determination based on MWCNT/melamine complex modified GC
    • Y. Li, Y. Gao, Y. Cao, H. Li, Electrochemical sensor for bisphenol A determination based on MWCNT/melamine complex modified GC, Sensors and Actuators BChemical 171-172 (2012) 726-733.
    • (2012) Sensors and Actuators BChemical , vol.171-172 , pp. 726-733
    • Li, Y.1    Gao, Y.2    Cao, Y.3    Li, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.