Volumn 38, Issue 6, 2012, Pages 668-676

Accuracy of cone beam computerized tomography and a three-dimensional stereolithographic model in identifying the anterior loop of the mental nerve: A study on cadavers

Author keywords

Anterior loop length; Cone beam computerized tomography; Mental foramen; Mental nerve; Overestimate; Safety margin; Stereolithographic model; Underestimate

Indexed keywords

AGED; ARTICLE; CADAVER; COMPARATIVE STUDY; CONE BEAM COMPUTED TOMOGRAPHY; DENTAL PROCEDURE; EVALUATION; FEMALE; HISTOLOGY; HUMAN; IMAGE PROCESSING; MALE; MANDIBULAR NERVE; MEDICAL PHOTOGRAPHY; METHODOLOGY; MIDDLE AGED; RADIOGRAPHY; THREE DIMENSIONAL IMAGING;

EID: 84872559162     PISSN: 01606972     EISSN: 15481336     Source Type: Journal    
DOI: 10.1563/AAID-JOI-D-11-00130     Document Type: Article
Times cited : (23)

References (40)
  • 1
    • 0030184468 scopus 로고    scopus 로고
    • Osseointegrated implants for single-tooth replacement: A prospective 5-year multicenter study
    • Henry PJ, Laney WR, Jemt T, et al. Osseointegrated implants for single-tooth replacement: a prospective 5-year multicenter study. Int J Oral Maxillofac Implants. 1996;11:450-455.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 450-455
    • Henry, P.J.1    Laney, W.R.2    Jemt, T.3
  • 5
    • 79960980312 scopus 로고    scopus 로고
    • Anatomy of mandibular vital structures. Part II: Mandibular incisive canal, mental foramen and associated neurovascular bundles in relation with dental implantology
    • Juodzbalys G, Wang HL, Sabalys G. Anatomy of mandibular vital structures. Part II: mandibular incisive canal, mental foramen and associated neurovascular bundles in relation with dental implantology. J Oral Maxillofac Res. 2010;1:e3
    • (2010) J Oral Maxillofac Res , vol.1
    • Juodzbalys, G.1    Wang, H.L.2    Sabalys, G.3
  • 8
    • 0030076222 scopus 로고    scopus 로고
    • Is there an anterior loop of the inferior alveolar nerve?
    • Rosenquist B. Is there an anterior loop of the inferior alveolar nerve? Int J Periodontics Restorative Dent. 1996;16:41-45.
    • (1996) Int J Periodontics Restorative Dent , vol.16 , pp. 41-45
    • Rosenquist, B.1
  • 9
    • 0025688549 scopus 로고
    • Predictable mandibular nerve location: A clinical zone of safety
    • Misch CE, Crawford EA. Predictable mandibular nerve location: a clinical zone of safety. Int J Oral Implantol. 1990;7:37.
    • (1990) Int J Oral Implantol , vol.7 , pp. 37
    • Misch, C.E.1    Crawford, E.A.2
  • 10
    • 34447634520 scopus 로고    scopus 로고
    • Neurosensory disturbances of the inferior alveolar nerve: A retrospective study of complaints in a 10-year period
    • Libersa T, Savignat M, Tonnel A. Neurosensory disturbances of the inferior alveolar nerve: a retrospective study of complaints in a 10-year period. J Oral Maxillofac Surg. 2007;65:1486-1489.
    • (2007) J Oral Maxillofac Surg , vol.65 , pp. 1486-1489
    • Libersa, T.1    Savignat, M.2    Tonnel, A.3
  • 11
    • 0030750912 scopus 로고    scopus 로고
    • Patients' perception of sensory disturbances of the mental nerve before and after implant surgery: A prospective study of 110 patients
    • Wismeijer D, van Waas MA, Vermeeren JI, Kalk W. Patients' perception of sensory disturbances of the mental nerve before and after implant surgery: a prospective study of 110 patients. Br J Oral Maxillofac Surg. 1997;35:254-259.
    • (1997) Br J Oral Maxillofac Surg , vol.35 , pp. 254-259
    • Wismeijer, D.1    Van Waas, M.A.2    Vermeeren, J.I.3    Kalk, W.4
  • 12
    • 0032150743 scopus 로고    scopus 로고
    • Sensory disturbances associated with implant surgery
    • Dao TT, Mellor A. Sensory disturbances associated with implant surgery. Int J Prosthodont. 1998;11:462-469.
    • (1998) Int J Prosthodont , vol.11 , pp. 462-469
    • Dao, T.T.1    Mellor, A.2
  • 13
    • 0032710022 scopus 로고    scopus 로고
    • The incidence of altered sensation of the mental nerve after mandibular implant placement
    • Bartling R, Freemand K, Kraut RA. The incidence of altered sensation of the mental nerve after mandibular implant placement. Int J Oral Maxillofac Surg. 1999;14:1408-1410.
    • (1999) Int J Oral Maxillofac Surg , vol.14 , pp. 1408-1410
    • Bartling, R.1    Freemand, K.2    Kraut, R.A.3
  • 14
    • 0034170227 scopus 로고    scopus 로고
    • Altered sensation associated with implants in the anterior mandible: A prospective study
    • Walton JN. Altered sensation associated with implants in the anterior mandible: a prospective study. J Prosthet Dent. 2000;83: 443-449.
    • (2000) J Prosthet Dent , vol.83 , pp. 443-449
    • Walton, J.N.1
  • 15
    • 0023840964 scopus 로고    scopus 로고
    • Neurosensory disturbance associated with the anterior mandibular horizontal osteotomy
    • Nishioka GJ, Manson M, Vansickels JE. Neurosensory disturbance associated with the anterior mandibular horizontal osteotomy. J Oral Maxillofac Surg. 1998;40:107-110.
    • (1998) J Oral Maxillofac Surg , vol.40 , pp. 107-110
    • Nishioka, G.J.1    Manson, M.2    Vansickels, J.E.3
  • 16
    • 0026889155 scopus 로고
    • The course of the inferior alveolar neurovascular canal in relation to sliding genioplasty
    • Ritter EF, Moelleken BRW, Mathes SJ, Ousterhout DK. The course of the inferior alveolar neurovascular canal in relation to sliding genioplasty. J Craniofac Surg. 1992;3:20-24.
    • (1992) J Craniofac Surg , vol.3 , pp. 20-24
    • Ritter, E.F.1    Moelleken, B.R.W.2    Mathes, S.J.3    Ousterhout, D.K.4
  • 17
    • 0026931182 scopus 로고
    • Altered sensation following mandibular implant surgery: A retrospective study
    • Ellies LG. Altered sensation following mandibular implant surgery: a retrospective study. J Prosthet Dent. 1992;68:664-671.
    • (1992) J Prosthet Dent , vol.68 , pp. 664-671
    • Ellies, L.G.1
  • 18
    • 34547935738 scopus 로고    scopus 로고
    • Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when Installing endosseous implants in the interforaminal region
    • Uchida Y, Yamashita Y, Goto M, Hanihara T. Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when Installing endosseous implants in the interforaminal region. J Oral Maxillofac Surg. 2007;65:1772-1779.
    • (2007) J Oral Maxillofac Surg , vol.65 , pp. 1772-1779
    • Uchida, Y.1    Yamashita, Y.2    Goto, M.3    Hanihara, T.4
  • 21
    • 4644285225 scopus 로고    scopus 로고
    • Morphometric analysis of implant-related anatomy in Caucasian skulls
    • Neiva RF, Gapski R, Wang HL. Morphometric analysis of implant-related anatomy in Caucasian skulls. J Periodontol. 2004;75: 1061-1067.
    • (2004) J Periodontol , vol.75 , pp. 1061-1067
    • Neiva, R.F.1    Gapski, R.2    Wang, H.L.3
  • 23
    • 0010551958 scopus 로고    scopus 로고
    • Root form surgery in the edentulous mandible: Stage i implant insertion
    • Misch CE, ed. 2nd ed. St Louis, Mo: CV Mosby Co
    • Misch CE. Root form surgery in the edentulous mandible: stage I implant insertion. In: Misch CE, ed. Implant Dentistry. 2nd ed. St Louis, Mo: CV Mosby Co; 1999;347-370.
    • (1999) Implant Dentistry , pp. 347-370
    • Misch, C.E.1
  • 26
    • 0032240404 scopus 로고    scopus 로고
    • A new volumetric CT machine for dental imaging based on the conebeam technique: Preliminary results
    • Mozzo P, Procacci C, Tacconi A, Martini PT, Andreis IA. A new volumetric CT machine for dental imaging based on the conebeam technique: preliminary results. Eur Radiol. 1998;8:1558-1564.
    • (1998) Eur Radiol , vol.8 , pp. 1558-1564
    • Mozzo, P.1    Procacci, C.2    Tacconi, A.3    Martini, P.T.4    Andreis, I.A.5
  • 27
    • 62649132042 scopus 로고    scopus 로고
    • Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing endosseous implants in the interforaminal region: A second attempt introducing cone beam computed tomography
    • Uchida Y, Noguchi N, Goto M, et al. Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing endosseous implants in the interforaminal region: a second attempt introducing cone beam computed tomography. J Oral Maxillofac Surg. 2009;67:744-750.
    • (2009) J Oral Maxillofac Surg , vol.67 , pp. 744-750
    • Uchida, Y.1    Noguchi, N.2    Goto, M.3
  • 29
    • 0036715882 scopus 로고    scopus 로고
    • Appearance, location, course, and morphology of the mandibular incisive canal: An assessment on spiral CT scan
    • Jacobs R, Mraiwa N, van Steenberghe D, Gijbels F, Quirynen M. Appearance, location, course, and morphology of the mandibular incisive canal: an assessment on spiral CT scan. Dentomaxillofac Radiol. 2002;31:322-327.
    • (2002) Dentomaxillofac Radiol , vol.31 , pp. 322-327
    • Jacobs, R.1    Mraiwa, N.2    Van Steenberghe, D.3    Gijbels, F.4    Quirynen, M.5
  • 31
    • 0028828254 scopus 로고
    • Fixture stability and nerve function after transposition and lateralization of the inferior alveolar nerve and fixture installation
    • Hirsch JM, Brånemark PI. Fixture stability and nerve function after transposition and lateralization of the inferior alveolar nerve and fixture installation. Br J Oral Maxillofac Surg. 1995;33:276-281.
    • (1995) Br J Oral Maxillofac Surg , vol.33 , pp. 276-281
    • Hirsch, J.M.1    Brånemark, P.I.2
  • 32
    • 0030325880 scopus 로고    scopus 로고
    • Atypical incisive nerve: Clinical report
    • Kohavi D, Bar-Ziv J. Atypical incisive nerve: clinical report. Implant Dent. 1996;5:281-283.
    • (1996) Implant Dent , vol.5 , pp. 281-283
    • Kohavi, D.1    Bar-Ziv, J.2
  • 33
    • 34547358852 scopus 로고    scopus 로고
    • A comparison of jaw dimensional and quality assessments of bone characteristics with cone-beam CT, spiral tomography, and multi-slice spiral CT
    • Loubele M, Guerrero ME, Jacobs R, Suetens P, van Steenberghe D. A comparison of jaw dimensional and quality assessments of bone characteristics with cone-beam CT, spiral tomography, and multi-slice spiral CT. Int J Oral Maxillofac Implants. 2007;22:446-454.
    • (2007) Int J Oral Maxillofac Implants , vol.22 , pp. 446-454
    • Loubele, M.1    Guerrero, M.E.2    Jacobs, R.3    Suetens, P.4    Van Steenberghe, D.5
  • 34
    • 14244264415 scopus 로고    scopus 로고
    • Analysis of accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom)
    • Lascala CA, Panella J, Marques MM. Analysis of accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom). Dentomaxillofac Radiol. 2004;33:291-294.
    • (2004) Dentomaxillofac Radiol , vol.33 , pp. 291-294
    • Lascala, C.A.1    Panella, J.2    Marques, M.M.3
  • 36
    • 72649103006 scopus 로고    scopus 로고
    • Accuracy of linear measurements from cone-beam computed tomographyderived surface models of different voxel sizes
    • discussion 16-17
    • Damstra J, Fourie Z. Huddleston Slater JJ, Ren Y. Accuracy of linear measurements from cone-beam computed tomographyderived surface models of different voxel sizes. Am J Orthod Dentofacial Orthop. 2010;137:16.e1-16.e6, discussion 16-17.
    • (2010) Am J Orthod Dentofacial Orthop. , vol.137
    • Damstra, J.1    Fourie, Z.2    Huddleston Slater, J.J.3    Ren, Y.4
  • 37
    • 0028318225 scopus 로고
    • Accuracy of stereolithographic models of human anatomy
    • Barker TM, Earwaker WJ, Lisle DA. Accuracy of stereolithographic models of human anatomy. Australas Radiol. 1994;38:106-111.
    • (1994) Australas Radiol , vol.38 , pp. 106-111
    • Barker, T.M.1    Earwaker, W.J.2    Lisle, D.A.3
  • 38
    • 77958093300 scopus 로고    scopus 로고
    • Accuracy and surgical feasibility of a CBCT-based stereolithographic surgical guide aiding autotransplantation of teeth: In vitro validation
    • Shahbazian M, Jacobs R, Wyatt J, et al. Accuracy and surgical feasibility of a CBCT-based stereolithographic surgical guide aiding autotransplantation of teeth: in vitro validation. J Oral Rehabil. 2010;37:854-859.
    • (2010) J Oral Rehabil , vol.37 , pp. 854-859
    • Shahbazian, M.1    Jacobs, R.2    Wyatt, J.3
  • 39
    • 0037946955 scopus 로고    scopus 로고
    • Accuracy of drilling guides for transfer from three-dimensional CTbased planning to placement of zygoma implants in human cadavers
    • Van Steenberghe D, Malevez C, Van Cleynenbreugel J, et al. Accuracy of drilling guides for transfer from three-dimensional CTbased planning to placement of zygoma implants in human cadavers. Clin Oral Implants Res. 2003;14:131-136.
    • (2003) Clin Oral Implants Res , vol.14 , pp. 131-136
    • Van Steenberghe, D.1    Malevez, C.2    Van Cleynenbreugel, J.3
  • 40
    • 0031264516 scopus 로고    scopus 로고
    • The validation of stereolithographic anatomical replicas: The authors' own experience and a review of the literature
    • Bianchi SD, Ramieri G, De Gioanni PP, Martinetto F, Berrone S. The validation of stereolithographic anatomical replicas: the authors' own experience and a review of the literature. Radiol Med. 1997;94:503-510.
    • (1997) Radiol Med , vol.94 , pp. 503-510
    • Bianchi, S.D.1    Ramieri, G.2    De Gioanni, P.P.3    Martinetto, F.4    Berrone, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.