메뉴 건너뛰기




Volumn 36, Issue 1, 2013, Pages 2-6

Implantable cardioverter-defibrillators: Is there life after death?

Author keywords

[No Author keywords available]

Indexed keywords

LITHIUM;

EID: 84872199275     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/pace.12023     Document Type: Review
Times cited : (5)

References (27)
  • 1
    • 80051705189 scopus 로고    scopus 로고
    • The 11th world survey of cardiac pacing and implantable cardioverter-defibrillators: Calendar year 2009 - A World Society of Arrhythmias project
    • Mond HG, Proclemer A,. The 11th world survey of cardiac pacing and implantable cardioverter-defibrillators: Calendar year 2009-a World Society of Arrhythmias project. Pacing Clin Electrophysiol 2011; 34: 1013-1027.
    • (2011) Pacing Clin Electrophysiol , vol.34 , pp. 1013-1027
    • Mond, H.G.1    Proclemer, A.2
  • 2
    • 0032920894 scopus 로고    scopus 로고
    • Sudden death in implantable cardioverter-defibrillator recipients: Clinical context, arrhythmic events and device responses
    • Pires L, Lehmann R, Steinman R,. Sudden death in implantable cardioverter-defibrillator recipients: Clinical context, arrhythmic events and device responses. J Am Coll Cardiol 1999; 33: 24-32.
    • (1999) J Am Coll Cardiol , vol.33 , pp. 24-32
    • Pires, L.1    Lehmann, R.2    Steinman, R.3
  • 4
    • 71049123912 scopus 로고    scopus 로고
    • Arrhythmic death in implantable cardioverter defibrillator patients: A long-term study over a 10 year implantation period
    • Duray GZ, Schmitt J, Richter S, Israel CW, Hohnloser SH,. Arrhythmic death in implantable cardioverter defibrillator patients: A long-term study over a 10 year implantation period. Europace 2009; 11: 1462-1468.
    • (2009) Europace , vol.11 , pp. 1462-1468
    • Duray, G.Z.1    Schmitt, J.2    Richter, S.3    Israel, C.W.4    Hohnloser, S.H.5
  • 5
    • 7744221160 scopus 로고    scopus 로고
    • Deaths associated with implantable cardioverter defibrillator failure and deactivation reported in the United States Food and Drug Administration Manufacturer and User Facility Device Experience Database
    • Hauser RG, Kallinen L,. Deaths associated with implantable cardioverter defibrillator failure and deactivation reported in the United States Food and Drug Administration Manufacturer and User Facility Device Experience Database. Heart Rhythm 2004; 4: 399-405.
    • (2004) Heart Rhythm , vol.4 , pp. 399-405
    • Hauser, R.G.1    Kallinen, L.2
  • 6
    • 84872202355 scopus 로고    scopus 로고
    • Rev. B.1, 03-FEB-2009. CRM Technical Services U.S., Mounds View, MN, Medtronic
    • Medtronic standard letter: Death and product handling. Rev. B.1, 03-FEB-2009. CRM Technical Services U.S., Mounds View, MN, Medtronic.
    • Medtronic Standard Letter: Death and Product Handling
  • 7
    • 84872179855 scopus 로고    scopus 로고
    • Cremation Association of North America. org/?page=IndustryStatistics (accessed March 11, 2012)
    • Cremation Association of North America. 2008 CANA statistics report. Available at: http://www.cremationassociation. org/?page=IndustryStatistics (accessed March 11, 2012).
    • 2008 CANA Statistics Report
  • 8
    • 84872199496 scopus 로고    scopus 로고
    • Karolinska Hospital, Stockholm, Sweden. March 21. Personal communication, Department of Cardiology
    • Gadler F, Director of Pacing, Department of Cardiology, Karolinska Hospital, Stockholm, Sweden. March 21, 2012. Personal communication.
    • (2012) Director of Pacing
    • Gadler, F.1
  • 10
    • 84872201083 scopus 로고    scopus 로고
    • National Funeral Directors Association (accessed March 31, 2012)
    • Code of professional conduct. National Funeral Directors Association. Available at: http://www.nfda.org/files/codeofconduct.pdf (accessed March 31, 2012).
    • Code of Professional Conduct
  • 11
    • 33645758855 scopus 로고    scopus 로고
    • Postmortem analysis and retrieval of implantable pacemakers and defibrillators
    • Kirkpatrick J, Burke M, Knight B,. Postmortem analysis and retrieval of implantable pacemakers and defibrillators. N Eng J Med 2006; 354: 1649-1650.
    • (2006) N Eng J Med , vol.354 , pp. 1649-1650
    • Kirkpatrick, J.1    Burke, M.2    Knight, B.3
  • 12
    • 79958139531 scopus 로고    scopus 로고
    • Recovery of pacemakers and defibrillators for analysis and device advance directives: Electrophysiologists' perspectives
    • Logani S, Gottlieb M, Verdino RJ, Baman TS,. Recovery of pacemakers and defibrillators for analysis and device advance directives: Electrophysiologists' perspectives. Pacing Clin Electrophysiol 2011; 34: 659-665.
    • (2011) Pacing Clin Electrophysiol , vol.34 , pp. 659-665
    • Logani, S.1    Gottlieb, M.2    Verdino, R.J.3    Baman, T.S.4
  • 13
    • 0031706489 scopus 로고    scopus 로고
    • Implantable cardioverter-defibrillators and the pathologist: Comment and cautionery notes
    • Walley VM, Bourke ME, Green M, Stinson WA, Veinot JP,. Implantable cardioverter-defibrillators and the pathologist: Comment and cautionery notes. J Forensic Sci 1998; 43: 969-973.
    • (1998) J Forensic Sci , vol.43 , pp. 969-973
    • Walley, V.M.1    Bourke, M.E.2    Green, M.3    Stinson, W.A.4    Veinot, J.P.5
  • 15
    • 70349488036 scopus 로고    scopus 로고
    • Making post-mortem implantable cardioverter-defibrillator explantation safe
    • Räder SBEW, Zeijlemaker V, Pehrson S, Svendsen JH,. Making post-mortem implantable cardioverter-defibrillator explantation safe. Europace 2009; 11: 1317-1322.
    • (2009) Europace , vol.11 , pp. 1317-1322
    • Räder, S.1    Zeijlemaker, V.2    Pehrson, S.3    Svendsen, J.H.4
  • 17
    • 84863723090 scopus 로고    scopus 로고
    • An analysis of implantable cardiac device reliability. The case for improved postmarketing risk assessment and surveillance
    • Laskey W, Awad K, Lum J, Skodacek K, Zimmerman B, Selzman K, Zuckerman B,. An analysis of implantable cardiac device reliability. The case for improved postmarketing risk assessment and surveillance. Am J Therapeutics 2012; 19: 248-254.
    • (2012) Am J Therapeutics , vol.19 , pp. 248-254
    • Laskey, W.1    Awad, K.2    Lum, J.3    Skodacek, K.4    Zimmerman, B.5    Selzman, K.6    Zuckerman, B.7
  • 20
    • 84856155580 scopus 로고    scopus 로고
    • You shouldn't take it with you: Postmortem device reuse
    • Groh WJ,. You shouldn't take it with you: Postmortem device reuse. Heart Rhythm 2012; 9: 215-216.
    • (2012) Heart Rhythm , vol.9 , pp. 215-216
    • Groh, W.J.1
  • 21
    • 79958094525 scopus 로고    scopus 로고
    • Safety, efficacy and performance of implanted recycled cardiac rhythm management (CRM) devices in underpriviliged patients
    • Hasan R, Ghanbari H, Feldman D, Menesses D, Rivas D, Zakhem NC, Duarte C, et al. Safety, efficacy and performance of implanted recycled cardiac rhythm management (CRM) devices in underpriviliged patients. Pacing Clin Electrophysiol 2011; 34: 653-658.
    • (2011) Pacing Clin Electrophysiol , vol.34 , pp. 653-658
    • Hasan, R.1    Ghanbari, H.2    Feldman, D.3    Menesses, D.4    Rivas, D.5    Zakhem, N.C.6    Duarte, C.7
  • 23
    • 0024524790 scopus 로고
    • A prospective trial of new versus refurbished cardiac pacemakers: A Canadian experience
    • Rosengarten M, Chiu R, Hoffman R,. A prospective trial of new versus refurbished cardiac pacemakers: A Canadian experience. Can J Cardiol 1989; 5: 155-160.
    • (1989) Can J Cardiol , vol.5 , pp. 155-160
    • Rosengarten, M.1    Chiu, R.2    Hoffman, R.3
  • 24
    • 0022033438 scopus 로고
    • Report of the policy conference on pacemaker reuse sponsored by the North American Society of Pacing and Electrophysiology
    • Boal BH, Escher DJW, Furman S, Hauser R, Maloney J, Parsonnet V, Raza ST, et al. Report of the policy conference on pacemaker reuse sponsored by the North American Society of Pacing and Electrophysiology. J Am Coll Cardiol 1985; 5: 808-810.
    • (1985) J Am Coll Cardiol , vol.5 , pp. 808-810
    • Boal, B.H.1    Escher, D.J.W.2    Furman, S.3    Hauser, R.4    Maloney, J.5    Parsonnet, V.6    Raza, S.T.7
  • 25
    • 79958709162 scopus 로고    scopus 로고
    • Abstract: Preliminary experience regarding re-use of explanted, resterilized defibrillators (AHA 2010)
    • Pavri BB, Kulkarni G, Lokhandwala Y, Kantharia BK, Mascarenas D,. Abstract: Preliminary experience regarding re-use of explanted, resterilized defibrillators (AHA 2010). Circulation 2010; 122: A18350.
    • (2010) Circulation , vol.122
    • Pavri, B.B.1    Kulkarni, G.2    Lokhandwala, Y.3    Kantharia, B.K.4    Mascarenas, D.5
  • 27
    • 33749061476 scopus 로고    scopus 로고
    • Recommendations from the Heart Rhythm Society Task Force on device performance policies and guidelines endorsed by the American College of Cardiology Foundation (ACCF) and the American Heart Association (AHA) and the International Coalition of Pacing and Electrophysiology Organizations (COPE)
    • Carlson M, Wilkoff B, Maisel W, Ellenbogen K, Saxon L, Prystowsky E, Alpert JS, et al. Recommendations from the Heart Rhythm Society Task Force on device performance policies and guidelines endorsed by the American College of Cardiology Foundation (ACCF) and the American Heart Association (AHA) and the International Coalition of Pacing and Electrophysiology Organizations (COPE). Heart Rhythm 2006; 3: 1250-1273.
    • (2006) Heart Rhythm , vol.3 , pp. 1250-1273
    • Carlson, M.1    Wilkoff, B.2    Maisel, W.3    Ellenbogen, K.4    Saxon, L.5    Prystowsky, E.6    Alpert, J.S.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.