메뉴 건너뛰기




Volumn 36, Issue 1, 2013, Pages 24-30

Reduction of procedure duration and radiation exposure with a dedicated inner lumen mapping catheter during pulmonary vein cryoablation

Author keywords

ablation; Atrial fibrillation; circular mapping catheter; cryoablation; pulmonary vein isolation

Indexed keywords

ARTICLE; CATHETER; CLINICAL ARTICLE; CLINICAL EVALUATION; CONTROLLED STUDY; CRYOABLATION; DISEASE DURATION; FEMALE; FLUOROSCOPY; FOLLOW UP; HEART ATRIUM FIBRILLATION; HUMAN; HYPERTENSION; INNER LUMEN MAPPING CATHETER; MALE; OUTCOME ASSESSMENT; PULMONARY VEIN; PULMONARY VEIN ISOLATION; RADIATION EXPOSURE;

EID: 84872196674     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/pace.12015     Document Type: Article
Times cited : (13)

References (16)
  • 1
    • 27644568168 scopus 로고    scopus 로고
    • Efficacy and safety of circumferential pulmonary vein isolation using a novel cryothermal balloon ablation system
    • Sarabanda AV, Bunch TJ, Johnson SB, Mahapatra S, Milton MA, Leite LR, Bruce K, et al. Efficacy and safety of circumferential pulmonary vein isolation using a novel cryothermal balloon ablation system. J Am Coll Cardiol 2005; 46: 1902-1912.
    • (2005) J Am Coll Cardiol , vol.46 , pp. 1902-1912
    • Sarabanda, A.V.1    Bunch, T.J.2    Johnson, S.B.3    Mahapatra, S.4    Milton, M.A.5    Leite, L.R.6    Bruce, K.7
  • 3
    • 47149112945 scopus 로고    scopus 로고
    • Circumferential pulmonary vein isolation with the cryoballoon technique results from a prospective 3-center study
    • Neumann T, Vogt J, Schumacher B, Dorszewski A, Kuniss M, Neuser H, Kurzidim K, et al. Circumferential pulmonary vein isolation with the cryoballoon technique results from a prospective 3-center study. J Am Coll Cardiol 2008; 52: 273-278.
    • (2008) J Am Coll Cardiol , vol.52 , pp. 273-278
    • Neumann, T.1    Vogt, J.2    Schumacher, B.3    Dorszewski, A.4    Kuniss, M.5    Neuser, H.6    Kurzidim, K.7
  • 4
    • 77956111336 scopus 로고    scopus 로고
    • Pulmonary venous isolation by antral ablation with a large cryoballoon for treatment of paroxysmal and persistent atrial fibrillation: Medium-term outcomes and non-randomised comparison with pulmonary venous isolation by radiofrequency ablation
    • Kojodjojo P, O'Neill MD, Lim PB, Malcolm-Lawes L, Whinnett ZI, Salukhe TV, Linton NW, et al. Pulmonary venous isolation by antral ablation with a large cryoballoon for treatment of paroxysmal and persistent atrial fibrillation: Medium-term outcomes and non-randomised comparison with pulmonary venous isolation by radiofrequency ablation. Heart 2010; 96: 1379-1384.
    • (2010) Heart , vol.96 , pp. 1379-1384
    • Kojodjojo, P.1    O'Neill, M.D.2    Lim, P.B.3    Malcolm-Lawes, L.4    Whinnett, Z.I.5    Salukhe, T.V.6    Linton, N.W.7
  • 5
    • 64949092842 scopus 로고    scopus 로고
    • The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: A prospective observational single centre study
    • Chun KR, Schmidt B, Metzner A, Tilz R, Zerm T, Köster I, Fürnkranz A, et al. The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: A prospective observational single centre study. Eur Heart J 2009; 30: 699-709.
    • (2009) Eur Heart J , vol.30 , pp. 699-709
    • Chun, K.R.1    Schmidt, B.2    Metzner, A.3    Tilz, R.4    Zerm, T.5    Köster, I.6    Fürnkranz, A.7
  • 6
    • 55249120449 scopus 로고    scopus 로고
    • One year follow-up after cryoballoon isolation of the pulmonary veins in patients with paroxysmal atrial fibrillation
    • Van Belle Y, Janse P, Theuns D, Szili-Torok T, Jordaens L,. One year follow-up after cryoballoon isolation of the pulmonary veins in patients with paroxysmal atrial fibrillation. Europace 2008; 10: 1271-1276.
    • (2008) Europace , vol.10 , pp. 1271-1276
    • Van Belle, Y.1    Janse, P.2    Theuns, D.3    Szili-Torok, T.4    Jordaens, L.5
  • 7
    • 84862993314 scopus 로고    scopus 로고
    • Pulmonary vein isolation during cryoballoon ablation using the novel Achieve inner lumen mapping catheter: A feasibility study
    • Chierchia GB, de Asmundis C, Namdar M, Westra S, Kuniss M, Sarkozy A, Bayrak F, et al. Pulmonary vein isolation during cryoballoon ablation using the novel Achieve inner lumen mapping catheter: A feasibility study. Europace 2012; 147: 962-967.
    • (2012) Europace , vol.147 , pp. 962-967
    • Chierchia, G.B.1    De Asmundis, C.2    Namdar, M.3    Westra, S.4    Kuniss, M.5    Sarkozy, A.6    Bayrak, F.7
  • 11
    • 84868635801 scopus 로고    scopus 로고
    • An apparent way of achieving proof of pulmonary vein disconnection during cryoballoon ablation
    • (in press; doi: 10.1111/j.1540-8159.2011.03187.x. [Epub ahead of print])
    • Schwagten B, DE Greef Y, Acou WJ, Stockman D,. An apparent way of achieving proof of pulmonary vein disconnection during cryoballoon ablation. Pacing Clin Electrophysiol 2011 (in press; doi: 10.1111/j.1540-8159.2011.03187. x. [Epub ahead of print]).
    • (2011) Pacing Clin Electrophysiol
    • Schwagten, B.1    De Greef, Y.2    Acou, W.J.3    Stockman, D.4
  • 12
    • 34247364622 scopus 로고    scopus 로고
    • Pulmonary vein isolation by high-intensity focused ultrasound: First-in-man study with a steerable balloon catheter
    • Schmidt B, Antz M, Ernst S, Ouyang F, Falk P, Chun JK, Kuck KH,. Pulmonary vein isolation by high-intensity focused ultrasound: First-in-man study with a steerable balloon catheter. Heart Rhythm 2007; 4: 575-584.
    • (2007) Heart Rhythm , vol.4 , pp. 575-584
    • Schmidt, B.1    Antz, M.2    Ernst, S.3    Ouyang, F.4    Falk, P.5    Chun, J.K.6    Kuck, K.H.7
  • 13
    • 70450215228 scopus 로고    scopus 로고
    • Comparison of cryoballoon and radiofrequency ablation of pulmonary veins in 40 patients with paroxysmal atrial fibrillation: A case-control study
    • Linhart M, Bellmann B, Mittmann-Braun E, Schrickel JW, Bitzen A, Andrié R, Yang A, et al. Comparison of cryoballoon and radiofrequency ablation of pulmonary veins in 40 patients with paroxysmal atrial fibrillation: A case-control study. J Cardiovasc Electrophysiol 2009; 20: 1343-1348.
    • (2009) J Cardiovasc Electrophysiol , vol.20 , pp. 1343-1348
    • Linhart, M.1    Bellmann, B.2    Mittmann-Braun, E.3    Schrickel, J.W.4    Bitzen, A.5    Andrié, R.6    Yang, A.7
  • 16
    • 0036743169 scopus 로고    scopus 로고
    • Impact of the distribution and structure of myocardium in the pulmonary veins for radiofrequency ablation of atrial fibrillation
    • Weiss C, Gocht A, Willems S, Hoffmann M, Risius T, Meinertz T,. Impact of the distribution and structure of myocardium in the pulmonary veins for radiofrequency ablation of atrial fibrillation. Pacing Clin Electrophysiol 2002; 25: 1352-1356.
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 1352-1356
    • Weiss, C.1    Gocht, A.2    Willems, S.3    Hoffmann, M.4    Risius, T.5    Meinertz, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.