메뉴 건너뛰기




Volumn 32, Issue 3, 2011, Pages 205-211

Pulmonary vein electrophysiology during cryoballoon ablation as a predictor for procedural success

Author keywords

Atrial fibrillation; Catheter ablation; Cryoablation; Pulmonary vein isolation; Real time pulmonary vein conduction recording

Indexed keywords

ADULT; ARTERIOVENOUS FISTULA; BALLOON CATHETER; CATHETER ABLATION; CONFERENCE PAPER; CRYOBALLOON ABLATION; ELECTRODE; ELECTROPHYSIOLOGY; FEMALE; FEMORAL ARTERIOVENOUS FISTULA; GUIDE WIRE; HEART ATRIUM FIBRILLATION; HEMOPTYSIS; HUMAN; LUNG INFILTRATE; MAJOR CLINICAL STUDY; MALE; NERVE PARALYSIS; PHRENIC NERVE PARALYSIS; PREDICTION; PRIORITY JOURNAL; PULMONARY VEIN; PULMONARY VEIN ELECTROPHYSIOLOGY; RADIOFREQUENCY ABLATION;

EID: 84855574433     PISSN: 1383875X     EISSN: 15728595     Source Type: Journal    
DOI: 10.1007/s10840-011-9585-x     Document Type: Conference Paper
Times cited : (58)

References (18)
  • 1
    • 39649105652 scopus 로고    scopus 로고
    • Balloon catheter ablation to treat paroxysmal atrial fibrillation: What is the level of pulmonary venous isolation?
    • Reddy, V. Y., Neuzil, P., D'Avila, A., et al. (2008). Balloon catheter ablation to treat paroxysmal atrial fibrillation: what is the level of pulmonary venous isolation? Heart Rhythm, 5(3), 353-360.
    • (2008) Heart Rhythm , vol.5 , Issue.3 , pp. 353-360
    • Reddy, V.Y.1    Neuzil, P.2    D'Avila, A.3
  • 4
    • 4644299078 scopus 로고    scopus 로고
    • Percutaneous pulmonary vein cryoablation to treat atrial fibrillation
    • DOI 10.1023/B:JICE.0000042349.43097.1c
    • Wong, T., Markides, V., Peters, N. S., & Davies, D. W. (2004). Percutaneous pulmonary vein cryoablation to treat atrial fibrillation. Journal of Interventional Cardiac Electrophysiology, 11, 117-126. (Pubitemid 39273704)
    • (2004) Journal of Interventional Cardiac Electrophysiology , vol.11 , Issue.2 , pp. 117-126
    • Wong, T.1    Markides, V.2    Peters, N.S.3    Davies, D.W.4
  • 6
    • 71049120282 scopus 로고    scopus 로고
    • Cryoballoon pulmonary vein isolation with real-time recordings from the pulmonary veins
    • Chun, K. R., Fürnkranz, A., Metzner, A., et al. (2009). Cryoballoon pulmonary vein isolation with real-time recordings from the pulmonary veins. Journal of Cardiovascular Electrophysiology, 20, 1203-1210.
    • (2009) Journal of Cardiovascular Electrophysiology , vol.20 , pp. 1203-1210
    • Chun, K.R.1    Fürnkranz, A.2    Metzner, A.3
  • 7
    • 77952643364 scopus 로고    scopus 로고
    • A novel cryoballoon technique for mapping and isolating pulmonary veins: A feasibility and efficacy study
    • Tang, M., Kriatselis, C., Nedios, S., et al. (2010). A novel cryoballoon technique for mapping and isolating pulmonary veins: a feasibility and efficacy study. Journal of Cardiovascular Electrophysiology, 21, 626-631.
    • (2010) Journal of Cardiovascular Electrophysiology , vol.21 , pp. 626-631
    • Tang, M.1    Kriatselis, C.2    Nedios, S.3
  • 8
    • 70349480801 scopus 로고    scopus 로고
    • Pulmonary vein isolation with high-intensity focused ultrasound: Results from the HIFU 12F study
    • Schmidt, B., Chun, K. R. J., Metzner, A., et al. (2009). Pulmonary vein isolation with high-intensity focused ultrasound: results from the HIFU 12F study. Europace, 11, 1281-1288.
    • (2009) Europace , vol.11 , pp. 1281-1288
    • Schmidt, B.1    Chun, K.R.J.2    Metzner, A.3
  • 10
    • 0025872184 scopus 로고
    • Factors associated with recurrence of accessory pathway conduction after radiofrequency catheter ablation
    • Twidale, N., Wang, X. Z., Beckman, K. J., et al. (1991). Factors associated with recurrence of accessory pathway conduction after radiofrequency catheter ablation. Pacing and Clinical Electrophysiology, 14, 2042-2048.
    • (1991) Pacing and Clinical Electrophysiology , vol.14 , pp. 2042-2048
    • Twidale, N.1    Wang, X.Z.2    Beckman, K.J.3
  • 11
    • 0034680347 scopus 로고    scopus 로고
    • First human experience with pulmonary vein isolation using a through-theballoon circumferential ultrasound ablation system for recurrent atrial fibrillation
    • Natale, A., Pisano, E., Shewchik, J., et al. (2000). First human experience with pulmonary vein isolation using a through-theballoon circumferential ultrasound ablation system for recurrent atrial fibrillation. Circulation, 102, 1879-1982.
    • (2000) Circulation , vol.102 , pp. 1879-1982
    • Natale, A.1    Pisano, E.2    Shewchik, J.3
  • 13
    • 34247364622 scopus 로고    scopus 로고
    • Pulmonary vein isolation by high-intensity focused ultrasound: First-in-man study with a steerable balloon catheter
    • DOI 10.1016/j.hrthm.2007.01.017, PII S1547527107000483
    • Schmidt, B., Antz, M., Ernst, S., et al. (2007). Pulmonary vein isolation by high-intensity focused ultrasound: first-in-man study with a steerable balloon catheter. Heart Rhythm, 4, 575-584. (Pubitemid 46630380)
    • (2007) Heart Rhythm , vol.4 , Issue.5 , pp. 575-584
    • Schmidt, B.1    Antz, M.2    Ernst, S.3    Ouyang, F.4    Falk, P.5    Chun, J.K.R.6    Kuck, K.-H.7
  • 14
    • 34548803112 scopus 로고    scopus 로고
    • Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: Feasibility, complications, and short-term outcome
    • DOI 10.1093/eurheartj/ehm227
    • Van Belle, Y., Janse, P., Rivero-Ayerza, M. J., et al. (2007). Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome. European Heart Journal, 28, 2231-2237. (Pubitemid 47428935)
    • (2007) European Heart Journal , vol.28 , Issue.18 , pp. 2231-2237
    • Van Belle, Y.1    Janse, P.2    Rivero-Ayerza, M.J.3    Thornton, A.S.4    Jessurun, E.R.5    Theuns, D.6    Jordaens, L.7
  • 15
    • 64949127114 scopus 로고    scopus 로고
    • Cryoballoon ablation of paroxysmal atrial fibrillation: Bigger is better and simpler is better
    • Koller, M. L., & Schumacher, B. (2009). Cryoballoon ablation of paroxysmal atrial fibrillation: bigger is better and simpler is better. European Heart Journal, 30, 636-637.
    • (2009) European Heart Journal , vol.30 , pp. 636-637
    • Koller, M.L.1    Schumacher, B.2
  • 16
    • 64949092842 scopus 로고    scopus 로고
    • The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: A prospective observational single centre study
    • Chun, K. R., Schmidt, B., Metzner, A., et al. (2009). The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre study. European Heart Journal, 30, 699-709.
    • (2009) European Heart Journal , vol.30 , pp. 699-709
    • Chun, K.R.1    Schmidt, B.2    Metzner, A.3
  • 17
    • 55249110821 scopus 로고    scopus 로고
    • Acute and clinical effects of cryoballoon pulmonary vein isolation in patients with symptomatic paroxysmal and persistent atrial fibrillation
    • Malmborg, H., Lonnerholm, S., & Blomstrom-Lundqvist, C. (2008). Acute and clinical effects of cryoballoon pulmonary vein isolation in patients with symptomatic paroxysmal and persistent atrial fibrillation. Europace, 10, 1277-1280.
    • (2008) Europace , vol.10 , pp. 1277-1280
    • Malmborg, H.1    Lonnerholm, S.2    Blomstrom-Lundqvist, C.3
  • 18
    • 77954062048 scopus 로고    scopus 로고
    • The permanency of pulmonary vein isolation using a balloon cryoablation catheter
    • Ahmed, H., Neuzil, P., Skoda, J., et al. (2010). The permanency of pulmonary vein isolation using a balloon cryoablation catheter. Journal of Cardiovascular Electrophysiology, 21, 731-737.
    • (2010) Journal of Cardiovascular Electrophysiology , vol.21 , pp. 731-737
    • Ahmed, H.1    Neuzil, P.2    Skoda, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.