메뉴 건너뛰기




Volumn 68, Issue 2, 2013, Pages 103-110

Occupational allergic contact dermatitis caused by sterile non-latex protective gloves: Clinical investigation and chemical analyses

Author keywords

allergic contact dermatitis; biocides; cetylpyridinium chloride; diphenylguanidine; occupational; protective gloves; rubber chemicals

Indexed keywords

1,3 DIPHENYLGUANIDINE; ALLERGEN; CETYLPYRIDINIUM SALT; DISULFIRAM; UNCLASSIFIED DRUG;

EID: 84872056832     PISSN: 01051873     EISSN: 16000536     Source Type: Journal    
DOI: 10.1111/cod.12010     Document Type: Article
Times cited : (62)

References (25)
  • 1
    • 22144472290 scopus 로고    scopus 로고
    • Extraction of haptens from solid products and their delivery to the skin, exemplified by dithiocarbamates from rubber gloves
    • Bergendorff O, Persson C, Hansson C., Extraction of haptens from solid products and their delivery to the skin, exemplified by dithiocarbamates from rubber gloves. Contact Dermatitis 2005: 53: 22-26.
    • (2005) Contact Dermatitis , vol.53 , pp. 22-26
    • Bergendorff, O.1    Persson, C.2    Hansson, C.3
  • 2
    • 33748474207 scopus 로고    scopus 로고
    • High-performance liquid chromatography analysis of rubber allergens in protective gloves used in healthcare
    • Bergendorff O, Persson C, Hansson C., High-performance liquid chromatography analysis of rubber allergens in protective gloves used in healthcare. Contact Dermatitis 2006: 55: 210-215.
    • (2006) Contact Dermatitis , vol.55 , pp. 210-215
    • Bergendorff, O.1    Persson, C.2    Hansson, C.3
  • 5
    • 0033006133 scopus 로고    scopus 로고
    • Surgical gloves: Current problems
    • Osman M O, Jensen S L., Surgical gloves: current problems. World J Surg 1999: 23: 630-637.
    • (1999) World J Surg , vol.23 , pp. 630-637
    • Osman, M.O.1    Jensen, S.L.2
  • 6
    • 63349101737 scopus 로고    scopus 로고
    • Thiuram patch test positivity 1980-2006: Incidence is now falling
    • Bhargava K, White I R, White J M., Thiuram patch test positivity 1980-2006: incidence is now falling. Contact Dermatitis 2009: 60: 222-223.
    • (2009) Contact Dermatitis , vol.60 , pp. 222-223
    • Bhargava, K.1    White, I.R.2    White, J.M.3
  • 7
    • 0031854342 scopus 로고    scopus 로고
    • Contact dermatitis from cetyl pyridinium chloride in latex surgical gloves
    • Steinkjer B., Contact dermatitis from cetyl pyridinium chloride in latex surgical gloves. Contact Dermatitis 1998: 39: 29-30.
    • (1998) Contact Dermatitis , vol.39 , pp. 29-30
    • Steinkjer, B.1
  • 8
    • 0027463778 scopus 로고
    • Allergic contact dermatitis from cetyl pyridinium chloride in latex gloves
    • Castelain M, Castelain P Y., Allergic contact dermatitis from cetyl pyridinium chloride in latex gloves. Contact Dermatitis 1993: 28: 118.
    • (1993) Contact Dermatitis , vol.28 , pp. 118
    • Castelain, M.1    Castelain, P.Y.2
  • 9
    • 0000524069 scopus 로고
    • Patch testing with ultrasonic bath extracts
    • Bruze M., Patch testing with ultrasonic bath extracts. Am J Contact Dermat 1992: 3: 133-137.
    • (1992) Am J Contact Dermat , vol.3 , pp. 133-137
    • Bruze, M.1
  • 10
    • 34247237322 scopus 로고    scopus 로고
    • Recommendation of appropriate amounts of petrolatum preparation to be applied at patch testing
    • Bruze M, Isaksson M, Gruvberger B, Frick-Engfeldt M., Recommendation of appropriate amounts of petrolatum preparation to be applied at patch testing. Contact Dermatitis 2007: 56: 281-285.
    • (2007) Contact Dermatitis , vol.56 , pp. 281-285
    • Bruze, M.1    Isaksson, M.2    Gruvberger, B.3    Frick-Engfeldt, M.4
  • 13
    • 0037258179 scopus 로고    scopus 로고
    • Occupational rubber glove allergy: Results of the Information Network of Departments of Dermatology (IVDK), 1995-2001
    • Information Network of Departments of Dermatology (IVDK)
    • Geier J, Lessmann H, Uter W, Schnuch A, Information Network of Departments of Dermatology (IVDK). Occupational rubber glove allergy: results of the Information Network of Departments of Dermatology (IVDK), 1995-2001. Contact Dermatitis 2003: 48: 39-44.
    • (2003) Contact Dermatitis , vol.48 , pp. 39-44
    • Geier, J.1    Lessmann, H.2    Uter, W.3    Schnuch, A.4
  • 14
    • 77957126887 scopus 로고    scopus 로고
    • Allergic contact dermatitis to synthetic rubber gloves: Changing trends in patch test reactions to accelerators
    • Cao L Y, Taylor J S, Sood A, Murray D, Siegel P D., Allergic contact dermatitis to synthetic rubber gloves: changing trends in patch test reactions to accelerators. Arch Dermatol 2010: 146: 1001-1007.
    • (2010) Arch Dermatol , vol.146 , pp. 1001-1007
    • Cao, L.Y.1    Taylor, J.S.2    Sood, A.3    Murray, D.4    Siegel, P.D.5
  • 15
    • 0028287271 scopus 로고
    • Occupational allergic contact dermatitis from diphenylguanidine in a gas mask
    • Bruze M, Kestrup L., Occupational allergic contact dermatitis from diphenylguanidine in a gas mask. Contact Dermatitis 1994: 31: 125-126.
    • (1994) Contact Dermatitis , vol.31 , pp. 125-126
    • Bruze, M.1    Kestrup, L.2
  • 16
    • 77955658761 scopus 로고    scopus 로고
    • Contact allergy to thiurams: Multifactorial analysis of clinical surveillance data collected by the IVDK network
    • Uter W, Hegewald J, Pfahlberg A, Lessmann H, Schnuch A, Gefeller O., Contact allergy to thiurams: multifactorial analysis of clinical surveillance data collected by the IVDK network. Int Arch Occup Environ Health 2010: 83: 675-681.
    • (2010) Int Arch Occup Environ Health , vol.83 , pp. 675-681
    • Uter, W.1    Hegewald, J.2    Pfahlberg, A.3    Lessmann, H.4    Schnuch, A.5    Gefeller, O.6
  • 18
    • 33749584361 scopus 로고    scopus 로고
    • Incidence by occupation and industry of work-related skin diseases in the United Kingdom, 1996-2001
    • McDonald J C, Beck M H, Chen Y, Cherry N M., Incidence by occupation and industry of work-related skin diseases in the United Kingdom, 1996-2001. Occup Med (Lond) 2006: 56: 398-405.
    • (2006) Occup Med (Lond) , vol.56 , pp. 398-405
    • McDonald, J.C.1    Beck, M.H.2    Chen, Y.3    Cherry, N.M.4
  • 20
    • 33644886019 scopus 로고    scopus 로고
    • Reduction in the frequency of sensitization to thiurams. A result of legislation?
    • Knudsen B, Lerbaek A, Johansen J D, Menné T., Reduction in the frequency of sensitization to thiurams. A result of legislation? Contact Dermatitis 2006: 54: 170-171.
    • (2006) Contact Dermatitis , vol.54 , pp. 170-171
    • Knudsen, B.1    Lerbaek, A.2    Johansen, J.D.3    Menné, T.4
  • 21
    • 58149347481 scopus 로고    scopus 로고
    • Occupation-related contact dermatitis in North American health care workers referred for patch testing: Cross-sectional data, 1998 to 2004
    • Warshaw E M, Schram S E, Maibach H I et al., Occupation-related contact dermatitis in North American health care workers referred for patch testing: cross-sectional data, 1998 to 2004. Dermatitis 2008: 19: 261-274.
    • (2008) Dermatitis , vol.19 , pp. 261-274
    • Warshaw, E.M.1    Schram, S.E.2    Maibach, H.I.3
  • 22
    • 42149132200 scopus 로고    scopus 로고
    • Occupational dermatoses in health care workers evaluated for suspected allergic contact dermatitis
    • Suneja T, Belsito D V., Occupational dermatoses in health care workers evaluated for suspected allergic contact dermatitis. Contact Dermatitis 2008: 58: 285-290.
    • (2008) Contact Dermatitis , vol.58 , pp. 285-290
    • Suneja, T.1    Belsito, D.V.2
  • 23
    • 0023879975 scopus 로고
    • Carbamix is redundant in the patch test series
    • Logan R A, White I R., Carbamix is redundant in the patch test series. Contact Dermatitis 1988: 18: 303-304.
    • (1988) Contact Dermatitis , vol.18 , pp. 303-304
    • Logan, R.A.1    White, I.R.2
  • 24
    • 17844382125 scopus 로고    scopus 로고
    • Patch testing discordance alert: False-negative findings with rubber additives and fragrances
    • Sherertz E F, Fransway A F, Belsito D V et al., Patch testing discordance alert: false-negative findings with rubber additives and fragrances. J Am Acad Dermatol 2001: 45: 313-314.
    • (2001) J Am Acad Dermatol , vol.45 , pp. 313-314
    • Sherertz, E.F.1    Fransway, A.F.2    Belsito, D.V.3
  • 25
    • 77949587884 scopus 로고    scopus 로고
    • Allergen content of patient problem and non-problem gloves: Relationship to allergen-specific patch-test findings
    • Siegel P D, Fowler J F, Storrs F J et al., Allergen content of patient problem and non-problem gloves: relationship to allergen-specific patch-test findings. Dermatitis 2010: 21: 77-83.
    • (2010) Dermatitis , vol.21 , pp. 77-83
    • Siegel, P.D.1    Fowler, J.F.2    Storrs, F.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.