메뉴 건너뛰기




Volumn 13, Issue 6, 2012, Pages 929-939

An automatic microfluidic system that continuously performs the systematic evolution of ligands by exponential enrichment

Author keywords

Alpha fetoprotein; Aptamers; Microfluidics; SELEX

Indexed keywords

ALPHA-FETOPROTEIN; APTAMERS; COMBINATORIAL LIBRARY; FAST SCREENING; HIGH AFFINITY; MICRO FLUIDIC SYSTEM; MICROFLUIDIC CHIP; SCREENING PROCESS; SELEX; SINGLE-STRANDED DNA; SYNTHETIC NUCLEIC ACID; SYSTEMATIC EVOLUTION OF LIGANDS BY EXPONENTIAL ENRICHMENTS;

EID: 84871809253     PISSN: 16134982     EISSN: 16134990     Source Type: Journal    
DOI: 10.1007/s10404-012-1013-8     Document Type: Article
Times cited : (9)

References (22)
  • 1
    • 81055124768 scopus 로고    scopus 로고
    • Probing the limits of aptamer affinity with a microfluidic SELEX platform
    • Ahmad KM, Oh SS, Kim S, McClellen FM, Xiao Y, Soh HT (2011) Probing the limits of aptamer affinity with a microfluidic SELEX platform. PLoS One 6(11):e27051
    • (2011) PLoS One , vol.6 , Issue.11
    • Ahmad, K.M.1    Oh, S.S.2    Kim, S.3    McClellen, F.M.4    Xiao, Y.5    Soh, H.T.6
  • 2
    • 67649831263 scopus 로고    scopus 로고
    • Detection of C reactive protein (CRP) in serum by an electrochemical aptamer-based sandwich assay
    • Centi S, Sanmartin LB, Tombelli S, Palchetti I, Mascini M (2009) Detection of C reactive protein (CRP) in serum by an electrochemical aptamer-based sandwich assay. Electroanal 21(11): 1309-1315
    • (2009) Electroanal , vol.21 , Issue.11 , pp. 1309-1315
    • Centi, S.1    Sanmartin, L.B.2    Tombelli, S.3    Palchetti, I.4    Mascini, M.5
  • 4
    • 33745254515 scopus 로고    scopus 로고
    • Micro total analysis systems. Latest advancements and trends
    • DOI 10.1021/ac0605602
    • Dittrich PS, Tachikawa K, Manz A (2006) Micro total analysis systems. Latest advancements and trends. Anal Chem 78(12): 3887-3907 (Pubitemid 43927398)
    • (2006) Analytical Chemistry , vol.78 , Issue.12 , pp. 3887-3907
    • Dittrich, P.S.1    Tachikawa, K.2    Manz, A.3
  • 5
    • 0025074907 scopus 로고
    • In vitro selection of RNA molecules that bind specific ligands
    • Ellington AD, Szostak JW (1990) In vitro selection of RNA molecules that bind specific ligands. Nature 346(6287):818-822
    • (1990) Nature , vol.346 , Issue.6287 , pp. 818-822
    • Ellington, A.D.1    Szostak, J.W.2
  • 6
    • 0026599465 scopus 로고
    • Selection invitro of single-stranded-DNA molecules that fold into specific ligand-binding structures
    • Ellington AD, Szostak JW (1992) Selection invitro of single-stranded-DNA molecules that fold into specific ligand-binding structures. Nature 355(6363):850-852
    • (1992) Nature , vol.355 , Issue.6363 , pp. 850-852
    • Ellington, A.D.1    Szostak, J.W.2
  • 7
    • 33646580369 scopus 로고    scopus 로고
    • Aptamer-conjugated nanoparticles for selective collection and detection of cancer cells
    • DOI 10.1021/ac052015r
    • Herr JK, Smith JE, Medley CD, Shangguan DH, Tan WH (2006) Aptamer-conjugated nanoparticles for selective collection and detection of cancer cells. Anal Chem 78(9):2918-2924 (Pubitemid 43726108)
    • (2006) Analytical Chemistry , vol.78 , Issue.9 , pp. 2918-2924
    • Herr, J.K.1    Smith, J.E.2    Medley, C.D.3    Shangguan, D.4    Tan, W.5
  • 8
    • 77952294160 scopus 로고    scopus 로고
    • Integrated microfluidic system for rapid screening of CRP aptamers utilizing systematic evolution of ligands by exponential enrichment (SELEX)
    • Huang C-J, Lin H-I, Shiesh S-C, Lee G-B (2010) Integrated microfluidic system for rapid screening of CRP aptamers utilizing systematic evolution of ligands by exponential enrichment (SELEX). Biosens Bioelectron 25(7):1761-1766
    • (2010) Biosens Bioelectron , vol.25 , Issue.7 , pp. 1761-1766
    • Huang, C.-J.1    Lin, H.-I.2    Shiesh, S.-C.3    Lee, G.-B.4
  • 9
    • 0032860385 scopus 로고    scopus 로고
    • Aptamers: An emerging class of molecules that rival antibodies in diagnostics
    • Jayasena SD (1999) Aptamers: an emerging class of molecules that rival antibodies in diagnostics. Clin Chem 45(9):1628-1650 (Pubitemid 29419030)
    • (1999) Clinical Chemistry , vol.45 , Issue.9 , pp. 1628-1650
    • Jayasena, S.D.1
  • 10
    • 0028224199 scopus 로고
    • High-resolution molecular discrimination by RNA
    • Jenison RD, Gill SC, Pardi A, Polisky B (1994) High-resolution molecular discrimination by RNA. Science 263(5152):1425-1429 (Pubitemid 24137828)
    • (1994) Science , vol.263 , Issue.5152 , pp. 1425-1429
    • Jenison, R.D.1    Gill, S.C.2    Pardi, A.3    Polisky, B.4
  • 11
    • 10044265053 scopus 로고    scopus 로고
    • Micromachined polymerase chain reaction system for multiple DNA amplification of upper respiratory tract infectious diseases
    • Liao CS, Lee GB, Wu JJ, Chang CC, Hsieh TM, Huang FC, Luo CH (2005) Micromachined polymerase chain reaction system for multiple DNA amplification of upper respiratory tract infectious diseases. Biosens Bioelectron 20(7):1341-1348
    • (2005) Biosens Bioelectron , vol.20 , Issue.7 , pp. 1341-1348
    • Liao, C.S.1    Lee, G.B.2    Wu, J.J.3    Chang, C.C.4    Hsieh, T.M.5    Huang, F.C.6    Luo, C.H.7
  • 12
    • 77957916296 scopus 로고    scopus 로고
    • Rapid isolation and detection of cancer cells by utilizing integrated microfluidic systems
    • Lien KY, Chuang YH, Hung LY, Hsu KF, Lai WW, Ho CL, Chou CY, Lee GB (2010) Rapid isolation and detection of cancer cells by utilizing integrated microfluidic systems. Lab Chip 10(21):2875-2886
    • (2010) Lab Chip , vol.10 , Issue.21 , pp. 2875-2886
    • Lien, K.Y.1    Chuang, Y.H.2    Hung, L.Y.3    Hsu, K.F.4    Lai, W.W.5    Ho, C.L.6    Chou, C.Y.7    Lee, G.B.8
  • 15
    • 1642351161 scopus 로고    scopus 로고
    • Engineering flows in small devices: Microfluidics toward a lab-on-A-chip
    • Stone HA, Stroock AD, Ajdari A (2004) Engineering flows in small devices: microfluidics toward a lab-on-a-chip. Annu Rev Fluid Mech 36:381-411 (Pubitemid 38381916)
    • (2004) Annual Review of Fluid Mechanics , vol.36 , pp. 381-411
    • Stone, H.A.1    Stroock, A.D.2    Ajdari, A.3
  • 16
    • 0022514615 scopus 로고
    • Value of serum alpha-fetoprotein and ferritin in the diagnosis of hepatocellular carcinoma
    • Tatsuta M, Yamamura H, Iishi H, Kasugai H, Okuda S (1986) Value of serum alpha-fetoprotein and ferritin in the diagnosis of hepatocellular-carcinoma. Oncology 43(5):306-310 (Pubitemid 16054048)
    • (1986) Oncology , vol.43 , Issue.5 , pp. 306-310
    • Tatsuta, M.1    Yamamura, H.2    Iishi, H.3
  • 17
    • 34548598730 scopus 로고    scopus 로고
    • Membrane-activated microfluidic rotary devices for pumping and mixing
    • Tseng HY, Wang CH, Lin WY, Lee GB (2007) Membrane-activated microfluidic rotary devices for pumping and mixing. Biomed Microdevices 9(4):545-554
    • (2007) Biomed Microdevices , vol.9 , Issue.4 , pp. 545-554
    • Tseng, H.Y.1    Wang, C.H.2    Lin, W.Y.3    Lee, G.B.4
  • 18
    • 0025194307 scopus 로고
    • Systematic evolution of ligands by exponential enrichment: RNA ligands to bacteriophage T4 DNA polymerase
    • Tuerk C, Gold L (1990) Systematic evolution of ligands by exponential enrichment: RNA ligands to bacteriophage T4 DNA polymerase. Science 249(4968):505-510
    • (1990) Science , vol.249 , Issue.4968 , pp. 505-510
    • Tuerk, C.1    Gold, L.2
  • 19
    • 2942547450 scopus 로고    scopus 로고
    • Micro total analysis systems. Recent developments
    • Vilkner T, Janasek D, Manz A (2004) Micro total analysis systems. Recent developments. Anal Chem 76(12):3373-3385
    • (2004) Anal Chem , vol.76 , Issue.12 , pp. 3373-3385
    • Vilkner, T.1    Janasek, D.2    Manz, A.3
  • 20
    • 61849100543 scopus 로고    scopus 로고
    • A vortex-type micromixer utilizing pneumatically driven membranes
    • Yang SY, Lin JL, Lee GB (2009a) A vortex-type micromixer utilizing pneumatically driven membranes. J Micromech Microeng 19(3):035020
    • (2009) J Micromech Microeng , vol.19 , Issue.3 , pp. 035020
    • Yang, S.Y.1    Lin, J.L.2    Lee, G.B.3
  • 21
    • 67349245781 scopus 로고    scopus 로고
    • A pneumatic micropump incorporated with a normally closed valve capable of generating a high pumping rate and a high back pressure
    • Yang YN, Hsiung SK, Lee GB (2009b) A pneumatic micropump incorporated with a normally closed valve capable of generating a high pumping rate and a high back pressure. Microfluid Nanofluid 6(6):823-833
    • (2009) Microfluid Nanofluid , vol.6 , Issue.6 , pp. 823-833
    • Yang, Y.N.1    Hsiung, S.K.2    Lee, G.B.3
  • 22
    • 67349251480 scopus 로고    scopus 로고
    • An integrated microfluidic system for C-reactive protein measurement
    • Yang YN, Lin HI, Wang JH, Shiesh SC, Lee GB (2009c) An integrated microfluidic system for C-reactive protein measurement. Biosens Bioelectron 24(10):3091-3096
    • (2009) Biosens Bioelectron , vol.24 , Issue.10 , pp. 3091-3096
    • Yang, Y.N.1    Lin, H.I.2    Wang, J.H.3    Shiesh, S.C.4    Lee, G.B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.