-
1
-
-
10644239069
-
Enzymatic biosensor based on the ISFET and photopolymeric membrane for the determination of urea
-
A.V. Rebriiev, and N.F. Starodub Enzymatic biosensor based on the ISFET and photopolymeric membrane for the determination of urea Electroanalysis 16 2004 1891 1895
-
(2004)
Electroanalysis
, vol.16
, pp. 1891-1895
-
-
Rebriiev, A.V.1
Starodub, N.F.2
-
2
-
-
0014189555
-
An enzymatic and fluorophotometric method for estimating urea concentration in nanoliter specimens
-
A. Roch-Ramel An enzymatic and fluorophotometric method for estimating urea concentration in nanoliter specimens Analytical Biochemistry 21 1967 372 381
-
(1967)
Analytical Biochemistry
, vol.21
, pp. 372-381
-
-
Roch-Ramel, A.1
-
3
-
-
0001470544
-
A new approach to enzymatic assay based on flow-injection spectrophotometry with acid-base indicators
-
A. Ramsing, J. Ruzicka, and E.H. Hansen A new approach to enzymatic assay based on flow-injection spectrophotometry with acid-base indicators Analytica Chimica Acta 114 1980 165 181
-
(1980)
Analytica Chimica Acta
, vol.114
, pp. 165-181
-
-
Ramsing, A.1
Ruzicka, J.2
Hansen, E.H.3
-
4
-
-
0029020595
-
Clinical analysis of urea in human blood by coupling a surface acoustic wave sensor with urease extracted from pumpkin seeds
-
D. Liu, K. Ge, K. Cheng, L. Nie, and S. Yao Clinical analysis of urea in human blood by coupling a surface acoustic wave sensor with urease extracted from pumpkin seeds Analytica Chimica Acta 307 1995 61 69
-
(1995)
Analytica Chimica Acta
, vol.307
, pp. 61-69
-
-
Liu, D.1
Ge, K.2
Cheng, K.3
Nie, L.4
Yao, S.5
-
5
-
-
0001462484
-
Determination of urea in serium by a fiber-optic fluorescence biosensor
-
X. Xie, A.A. Suleiman, and G.G. Guilbault Determination of urea in serium by a fiber-optic fluorescence biosensor Talanta 38 1991 1197 1200
-
(1991)
Talanta
, vol.38
, pp. 1197-1200
-
-
Xie, X.1
Suleiman, A.A.2
Guilbault, G.G.3
-
6
-
-
0032164157
-
An amperometric urea biosensor based on a polyaniline-perfluorosulfonated ionomer composite electrode
-
W.J. Cho, and H.J. Huang An amperometric urea biosensor based on a polyaniline-perfluorosulfonated ionomer composite electrode Analytical Chemistry 70 1998 3946 3951
-
(1998)
Analytical Chemistry
, vol.70
, pp. 3946-3951
-
-
Cho, W.J.1
Huang, H.J.2
-
7
-
-
0030258463
-
High-sensitivity urea sensor based on the composite film of electroinactive polypyrrole with polyion complex
-
PII S0925400596020825
-
T. Osaka, S. Komaba, M. Seyama, and K. Tanabe High-sensitivity urea sensor based on the composite film of electroinactive polypyrrole with polyion complex Sensors and Actuators B 35 36 1996 463 469 (Pubitemid 126375950)
-
(1996)
Sensors and Actuators, B: Chemical
, vol.36
, Issue.1-3
, pp. 463-469
-
-
Osaka, T.1
Komaba, S.2
Seyama, M.3
Tanabe, K.4
-
9
-
-
0032925594
-
A disposable biosensor for urea determination in blood based on an ammonium-sensitive transducer
-
DOI 10.1016/S0956-5663(98)00103-1, PII S0956566398001031
-
C. Eggenstein, M. Borchardt, C. Diekmann, B. Grundig, C. Dumschat, K. Cammann, M. Knoll, and F. Spener A disposable biosensor for urea determination in blood based on an ammonium-sensitive transducer Biosensors and Bioelectronics 14 1999 33 41 (Pubitemid 29045650)
-
(1999)
Biosensors and Bioelectronics
, vol.14
, Issue.1
, pp. 33-41
-
-
Eggenstein, C.1
Borchardt, M.2
Diekmann, C.3
Grundig, B.4
Dumschat, C.5
Cammann, K.6
Knoll, M.7
Spener, F.8
-
10
-
-
0028254601
-
Determination of urea in urine using a conductivity cell with surface acoustic wave resonator-based measurement circuit
-
K. Chen, D. Liu, L. Nie, and S. Yao Determination of urea in urine using a conductivity cell with surface acoustic wave resonator-based measurement circuit Talanta 41 1994 2195 2200
-
(1994)
Talanta
, vol.41
, pp. 2195-2200
-
-
Chen, K.1
Liu, D.2
Nie, L.3
Yao, S.4
-
11
-
-
0029920787
-
Conductometric urea sensor. Use of additional membranes for the improvement of its analytical characteristics
-
DOI 10.1016/0003-2670(95)00548-X
-
A.S. Jdanova, S. Poyard, A.P. Soldatkin, N. Jaffrezic-Renault, and C. Martelet Conductometric urea sensor. Use of additional membranes for the improvement of its analytical characteristics Analytica Chimica Acta 321 1996 35 40 (Pubitemid 26080694)
-
(1996)
Analytica Chimica Acta
, vol.321
, Issue.1
, pp. 35-40
-
-
Jdanova, A.S.1
Poyard, S.2
Soldatkin, A.P.3
Jaffrezic-Renault, N.4
Martelet, C.5
-
12
-
-
0000900237
-
A coulometric flow analyzer for use with immobilized enzyme reactors
-
R.E. Adams, and P.W. Carr A coulometric flow analyzer for use with immobilized enzyme reactors Analytical Chemistry 50 1978 944 950
-
(1978)
Analytical Chemistry
, vol.50
, pp. 944-950
-
-
Adams, R.E.1
Carr, P.W.2
-
13
-
-
0029939109
-
Polypyrrole-based amperometric flow injection biosensor for urea
-
DOI 10.1016/0003-2670(95)00562-5
-
S.B. Adelju, S.J. Shaw, and G.G. Wallace Polypyrrole-based amperometric flow injection biosensor for urea Analytica Chimica Acta 323 1996 107 113 (Pubitemid 26115158)
-
(1996)
Analytica Chimica Acta
, vol.323
, Issue.1-3
, pp. 107-113
-
-
Adeloju, S.B.1
Shaw, S.J.2
Wallace, G.G.3
-
15
-
-
84856142276
-
Functionalized multilayered graphene platform for urea sensor
-
R.K. Srivastava, S. Srivastava, T.N. Narayanan, B.D. Mahlotra, R. Vajtai, P.M. Ajayan, and A. Srivastava Functionalized multilayered graphene platform for urea sensor ACS Nano 6 2012 168 175
-
(2012)
ACS Nano
, vol.6
, pp. 168-175
-
-
Srivastava, R.K.1
Srivastava, S.2
Narayanan, T.N.3
Mahlotra, B.D.4
Vajtai, R.5
Ajayan, P.M.6
Srivastava, A.7
-
16
-
-
0035972824
-
Urea biosensor based on amperometric pH-sensing with hematein as a pH-sensitive redox mediator
-
DOI 10.1016/S0039-9140(01)00331-9, PII S0039914001003319
-
A. Pizzariello, M. Stredansky, S. Stredanska, and S. Miertus Urea biosensor based on amperometric pH-sensing with hematein as a pH-sensitive redox mediator Talanta 54 2001 763 772 (Pubitemid 32458497)
-
(2001)
Talanta
, vol.54
, Issue.4
, pp. 763-772
-
-
Pizzariello, A.1
Stredansky, M.2
Stredanska, S.3
Miertus, S.4
-
17
-
-
0036125073
-
Application of conducting polymers to biosensors
-
DOI 10.1016/S0956-5663(01)00312-8, PII S0956566301003128
-
M. Gerard, A. Chaubey, and B.D. Malhotra Application of conducting polymers to biosensors Biosensors and Bioelectronics 17 2002 345 359 (Pubitemid 34223443)
-
(2002)
Biosensors and Bioelectronics
, vol.17
, Issue.5
, pp. 345-359
-
-
Gerard, M.1
Chaubey, A.2
Malhotra, B.D.3
-
18
-
-
62649097688
-
Entrapment of live microbial cells in electropolymerized polyaniline and their use as urea biosensor
-
S.K. Jha, M. Kanungo, A. Nath, and S.F. D'Souza Entrapment of live microbial cells in electropolymerized polyaniline and their use as urea biosensor Biosensors and Bioelectronics 24 2009 2637 2642
-
(2009)
Biosensors and Bioelectronics
, vol.24
, pp. 2637-2642
-
-
Jha, S.K.1
Kanungo, M.2
Nath, A.3
D'Souza, S.F.4
-
19
-
-
0026452279
-
Penicillin sensor based on microarray electrode coated with pH responsive polypyrrole
-
M. Nishizawa, T. Matsue, and I. Uchida Penicillin sensor based on microarray electrode coated with pH responsive polypyrrole Analytical Chemistry 64 1992 2642 2644
-
(1992)
Analytical Chemistry
, vol.64
, pp. 2642-2644
-
-
Nishizawa, M.1
Matsue, T.2
Uchida, I.3
-
21
-
-
11144317784
-
An amperometric urea biosensor based on covalent immobilization of urease onto an electrochemically prepared copolymer poly (N-3-aminopropyl pyrrole-co-pyrrole) film
-
DOI 10.1016/j.biomaterials.2004.09.024, PII S0142961204008403
-
Rajesh, V. Bisht, W. Takashima, and K. Kaneto An amperometric urea biosensor based on covalent immobilization of urease onto an electrochemically prepared copolymer poly (N-3-aminopropyl pyrrole-co-pyrrole) film Biomaterials 26 2005 3683 3690 (Pubitemid 40038163)
-
(2005)
Biomaterials
, vol.26
, Issue.17
, pp. 3683-3690
-
-
Rajesh1
Bisht, V.2
Takashima, W.3
Kaneto, K.4
-
22
-
-
0025250554
-
Polypyrrole-based sensor for hydrazine and ammonia
-
N.M. Ratcliffe Polypyrrole-based sensor for hydrazine and ammonia Analytica Chimica Acta 239 1990 257 262
-
(1990)
Analytica Chimica Acta
, vol.239
, pp. 257-262
-
-
Ratcliffe, N.M.1
-
23
-
-
0000110560
-
Electrochemical sensor for measurement of urea and creatinine in serum based on ac impedance measurement of enzyme-catalyzed polymer transformation
-
W.O. Ho, S. Krause, C.J. McNeil, J.A. Pritchard, R.D. Armstrong, D. Athey, and K. Rawson Electrochemical sensor for measurement of urea and creatinine in serum based on ac impedance measurement of enzyme-catalyzed polymer transformation Analytical Chemistry 71 1999 1940 1944
-
(1999)
Analytical Chemistry
, vol.71
, pp. 1940-1944
-
-
Ho, W.O.1
Krause, S.2
McNeil, C.J.3
Pritchard, J.A.4
Armstrong, R.D.5
Athey, D.6
Rawson, K.7
-
25
-
-
0026147814
-
Characterization of the biochemical behavior of glucose oxidase entrapped in a polypyrrole film
-
G. Fortier, and D. Belanger Characterization of the biochemical behavior of glucose oxidase entrapped in a polypyrrole film Biotechnology and Bioengineering 37 1991 854 858
-
(1991)
Biotechnology and Bioengineering
, vol.37
, pp. 854-858
-
-
Fortier, G.1
Belanger, D.2
-
26
-
-
0026435795
-
Amperometric polypyrrole enzyme electrodes: Effect of permeability and enzyme location
-
M. Hammerle, W. Schuhmann, and H.L. Schmidt Amperometric polypyrrole enzyme electrodes: effect of permeability and enzyme location Sensors and Actuators B 6 1992 106 112
-
(1992)
Sensors and Actuators B
, vol.6
, pp. 106-112
-
-
Hammerle, M.1
Schuhmann, W.2
Schmidt, H.L.3
-
27
-
-
84988058878
-
Ion exchanged polypyrrole-based glucose biosensor: Enhanced loading and response
-
K. Ramanathan, N.S. Sundaresan, and B.D. Malhotra Ion exchanged polypyrrole-based glucose biosensor: enhanced loading and response Electroanalysis 7 1995 579 582
-
(1995)
Electroanalysis
, vol.7
, pp. 579-582
-
-
Ramanathan, K.1
Sundaresan, N.S.2
Malhotra, B.D.3
-
28
-
-
0032207811
-
Enhanced loading of glucose oxidase on polyaniline films based on anion exchange
-
M.M. Verghese, K. Ramanathan, S.M. Ashraf, and B.D. Malhotra Enhanced loading of glucose oxidase on polyaniline films based on anion exchange Journal of Applied Polymer Science 70 1998 1447 1453 (Pubitemid 128567114)
-
(1998)
Journal of Applied Polymer Science
, vol.70
, Issue.8
, pp. 1447-1453
-
-
Verghese, M.M.1
Ramanathan, K.2
Ashraf, S.M.3
Malhotra, B.D.4
-
29
-
-
0024029876
-
Structure, strength and electrical performance of conducting polypyrroles
-
B.F. Cvetko, M.P. Brungs, R.P. Burford, M. Skyllas, and Kazacos Structure, strength and electrical performance of conducting polymer Journal of Materials Science 23 1988 2102 2106 (Pubitemid 18649642)
-
(1988)
Journal of Materials Science
, vol.23
, Issue.6
, pp. 2102-2106
-
-
Cvetko, B.F.1
Brungs, M.P.2
Burford, R.P.3
Skyllas-Kazsacos, M.4
-
30
-
-
84858240264
-
Self-assembled nanostructured polypyrrole films grown in a high-gravity environment
-
Jean H. Chang, Christian R. Aleman de Leon, and Ian W. Hunter Self-assembled nanostructured polypyrrole films grown in a high-gravity environment Langmuir 28 2012 4805 4810
-
(2012)
Langmuir
, vol.28
, pp. 4805-4810
-
-
Chang, J.H.1
Aleman De Leon, C.R.2
Hunter, I.W.3
-
31
-
-
69949086759
-
4-doped plasticized chitosan as biodegradable polymer gel electrolyte for supercapacitors
-
4-doped plasticized chitosan as biodegradable polymer gel electrolyte for supercapacitors Journal of Applied Polymer Science 114 2009 2445 2454
-
(2009)
Journal of Applied Polymer Science
, vol.114
, pp. 2445-2454
-
-
Kumar, M.S.1
Bhat, D.K.2
-
32
-
-
84860390387
-
Acid blue AS doped polypyrrole (PPy/AS) nanomaterials with different morphologies as electrode materials for supercapacitors
-
Y. Wang, C. Yang, and P. Liu Acid blue AS doped polypyrrole (PPy/AS) nanomaterials with different morphologies as electrode materials for supercapacitors Chemical Engineering Journal 172 2011 1137 1144
-
(2011)
Chemical Engineering Journal
, vol.172
, pp. 1137-1144
-
-
Wang, Y.1
Yang, C.2
Liu, P.3
-
34
-
-
18544391107
-
Polyaniline-modified electrode as an amperometric ascorbate sensor
-
DOI 10.1016/j.snb.2004.11.075, PII S0925400504008433
-
I. Jureviciute, K. Brazdziuviene, L. Bernotaite, B. Salkus, and A. Malinauskas Polyaniline-modified electrode as an amperometric ascorbate sensor Sensors and Actuators B 107 2005 716 721 (Pubitemid 40655010)
-
(2005)
Sensors and Actuators, B: Chemical
, vol.107
, Issue.2
, pp. 716-721
-
-
Jureviciute, I.1
Brazdziuviene, K.2
Bernotaite, L.3
Salkus, B.4
Malinauskas, A.5
-
35
-
-
38749132839
-
A novel capacitor material based on Nafion-doped polypyrrole
-
B.C. Kim, J.M. Ko, and G.G. Wallace A novel capacitor material based on Nafion-doped polypyrrole Journal of Power Sources 177 2008 665 668
-
(2008)
Journal of Power Sources
, vol.177
, pp. 665-668
-
-
Kim, B.C.1
Ko, J.M.2
Wallace, G.G.3
-
36
-
-
77949654696
-
A new amperometric cholesterol biosensor based on poly(3, 4-ethylenedioxypyrrole)
-
O. Turkarslan, S.K. Kayahan, and L. Toppare A new amperometric cholesterol biosensor based on poly(3, 4-ethylenedioxypyrrole) Sensors and Actuators B 136 2009 484 488
-
(2009)
Sensors and Actuators B
, vol.136
, pp. 484-488
-
-
Turkarslan, O.1
Kayahan, S.K.2
Toppare, L.3
-
37
-
-
10444265212
-
Development of a potentiometric urea biosensor based on copolymer poly(N-3-aminopropyl pyrrole-co-pyrrole) film
-
Rajesh, V. Bisht, W. Takashima, and K. Kaneto Development of a potentiometric urea biosensor based on copolymer poly(N-3-aminopropyl pyrrole-co-pyrrole) film Reactive & Functional Polymers 62 2005 51 59
-
(2005)
Reactive & Functional Polymers
, vol.62
, pp. 51-59
-
-
Rajesh1
Bisht, V.2
Takashima, W.3
Kaneto, K.4
-
38
-
-
62649117696
-
Ionic effect investigation of a potentiometric sensor for urea and surface morphology observation of entrapped urease/polypyrrole matrix
-
M.J. Syu, and Y.S. Chang Ionic effect investigation of a potentiometric sensor for urea and surface morphology observation of entrapped urease/polypyrrole matrix Biosensors and Bioelectronics 24 2009 2671 2677
-
(2009)
Biosensors and Bioelectronics
, vol.24
, pp. 2671-2677
-
-
Syu, M.J.1
Chang, Y.S.2
-
39
-
-
49749131231
-
Potentiometric urea biosensor based on BSA embedded surface modified polypyrrole film
-
T. Ahuja, I.A. Mir, D. Kumar, and Rajesh Potentiometric urea biosensor based on BSA embedded surface modified polypyrrole film Sensors and Actuators B 134 2008 140 145
-
(2008)
Sensors and Actuators B
, vol.134
, pp. 140-145
-
-
Ahuja, T.1
Mir, I.A.2
Kumar, D.3
Rajesh4
-
40
-
-
0000517072
-
Solution phenomena in liquid ammonia
-
J.J. Lagowski Solution phenomena in liquid ammonia Pure and Applied Chemistry 25 1971 429 456
-
(1971)
Pure and Applied Chemistry
, vol.25
, pp. 429-456
-
-
Lagowski, J.J.1
-
41
-
-
2942616869
-
Activated polyoyrrole electrodes for high-power supercapacitor applications
-
M.D. Ingram, H. Staesche, and K.S. Ryder Activated polyoyrrole electrodes for high-power supercapacitor applications Solid State Ionics 169 2004 51 57
-
(2004)
Solid State Ionics
, vol.169
, pp. 51-57
-
-
Ingram, M.D.1
Staesche, H.2
Ryder, K.S.3
|