Volumn 226, Issue 11, 2012, Pages 838-847

Evaluation of the performance of a motion capture system for small displacement recording and a discussion for its application potential in bone deformation in vivo measurements

Author keywords

accuracy; bone strain; in vivo; Motion capture system; precision

Indexed keywords

ABSOLUTE ERROR; ACCURACY; ACCURACY AND PRECISION; CALIBRATION PROCEDURE; DEFORMATION MEASUREMENTS; GAIT CYCLES; IN-VIVO; IN-VIVO MEASUREMENT; MOTION CAPTURE SYSTEM; OPTICAL AXIS; PRECISION; RANGE OF MOTIONS; SMALL DISPLACEMENT; SYSTEM ACCURACY; SYSTEM RESOLUTION; BONE STRAINS;

EID: 84871776818     PISSN: 09544119     EISSN: 20413033     Source Type: Journal    
DOI: 10.1177/0954411912452994     Document Type: Article
Times cited : (26)

References (26)
  • 1
    • 0028807366 scopus 로고
    • Mechanotransduction and the functional response of bone to mechanical strain
    • Duncan RL, Turner CH. Mechanotransduction and the functional response of bone to mechanical strain. Calcif Tissue Int. 1995 ; 57 (5). 344-358
    • (1995) Calcif Tissue Int , vol.57 , Issue.5 , pp. 344-358
    • Duncan, R.L.1    Turner, C.H.2
  • 2
    • 0028800124 scopus 로고
    • Skeletal adaptations to mechanical usage: Results from tibial loading studies in rats
    • Forwood MR, Turner CH. Skeletal adaptations to mechanical usage: results from tibial loading studies in rats. Bone. 1995 ; 17 (4 Suppl). 197S - 205S
    • (1995) Bone , vol.17 , Issue.4 SUPPL
    • Forwood, M.R.1    Turner, C.H.2
  • 3
    • 0029111672 scopus 로고
    • Mechanotransduction in bone: Role of strain rate
    • Turner CH, Owan I, Takano Y. Mechanotransduction in bone: role of strain rate. Am J Physiol. 1995 ; 269 (3 Pt 1). E438-442
    • (1995) Am J Physiol , vol.269 , Issue.3 PART 1 , pp. 438-442
    • Turner, C.H.1    Owan, I.2    Takano, Y.3
  • 4
    • 0032190413 scopus 로고    scopus 로고
    • Strain rate as a controlling influence on adaptive modeling in response to dynamic loading of the ulna in growing male rats
    • DOI 10.1016/S8756-3282(98)00113-6, PII S8756328298001136
    • Mosley JR, Lanyon LE. Strain rate as a controlling influence on adaptive modeling in response to dynamic loading of the ulna in growing male rats. Bone. 1998 ; 23 (4). 313-318 (Pubitemid 28454622)
    • (1998) Bone , vol.23 , Issue.4 , pp. 313-318
    • Mosley, J.R.1    Lanyon, L.E.2
  • 5
    • 79952420808 scopus 로고    scopus 로고
    • What do we currently know from in vivo bone strain measurements in humans?
    • Yang PF, Bruggemann GP, Rittweger J. What do we currently know from in vivo bone strain measurements in humans?. J Musculoskelet Neuronal Interact. 2011 ; 11 (1). 8-20
    • (2011) J Musculoskelet Neuronal Interact , vol.11 , Issue.1 , pp. 8-20
    • Yang, P.F.1    Bruggemann, G.P.2    Rittweger, J.3
  • 8
    • 1942474395 scopus 로고    scopus 로고
    • A comparison of bone strain measurements at anatomically relevant sites using surface gauges versus strain gauged bone staples
    • DOI 10.1016/j.jbiomech.2003.10.008, PII S0021929003003981
    • Milgrom C, Finestone A, Hamel A, et al. A comparison of bone strain measurements at anatomically relevant sites using surface gauges versus strain gauged bone staples. J Biomech. 2004 ; 37 (6). 947-952 (Pubitemid 38521218)
    • (2004) Journal of Biomechanics , vol.37 , Issue.6 , pp. 947-952
    • Milgrom, C.1    Finestone, A.2    Hamel, A.3    Mandes, V.4    Burr, D.5    Sharkey, N.6
  • 9
    • 34247566523 scopus 로고    scopus 로고
    • Measurement of strain distributions in mouse femora with 3D-digital speckle pattern interferometry
    • DOI 10.1016/j.optlaseng.2007.02.004, PII S0143816607000516
    • Yang L, Zhang P, Liu S, et al. Measurement of strain distributions in mouse femora with 3D-digital speckle pattern interferometry. Opt Lasers Eng. 2007 ; 45 (8). 843-851 (Pubitemid 46670319)
    • (2007) Optics and Lasers in Engineering , vol.45 , Issue.8 , pp. 843-851
    • Yang, L.1    Zhang, P.2    Liu, S.3    Samala, P.R.4    Su, M.5    Yokota, H.6
  • 10
    • 77952490622 scopus 로고    scopus 로고
    • Using digital image correlation to determine bone surface strains during loading and after adaptation of the mouse tibia
    • Sztefek P, Vanleene M, Olsson R, et al. Using digital image correlation to determine bone surface strains during loading and after adaptation of the mouse tibia. J Biomech. 2010 ; 43 (4). 599-605
    • (2010) J Biomech , vol.43 , Issue.4 , pp. 599-605
    • Sztefek, P.1    Vanleene, M.2    Olsson, R.3
  • 11
    • 33645707138 scopus 로고    scopus 로고
    • Comparison of the linear finite element prediction of deformation and strain of human cancellous bone to 3D digital volume correlation measurements
    • Zauel R, Yeni YN, Bay BK, et al. Comparison of the linear finite element prediction of deformation and strain of human cancellous bone to 3D digital volume correlation measurements. J Biomech Eng. 2006 ; 128 (1). 1-6
    • (2006) J Biomech Eng , vol.128 , Issue.1 , pp. 1-6
    • Zauel, R.1    Yeni, Y.N.2    Bay, B.K.3
  • 13
    • 0002308563 scopus 로고    scopus 로고
    • Direct linear transformation from comparator coordinates into object space coordinates in close range photogrammetry
    • Abdel-Aziz YI, Karara HM. Direct linear transformation from comparator coordinates into object space coordinates in close range photogrammetry. Proceedings of the symposium on close-range photogrammetry ; 1971 ; 1971..
    • Proceedings of the Symposium on Close-range Photogrammetry
    • Abdel-Aziz, Y.I.1    Karara, H.M.2
  • 14
    • 49449118813 scopus 로고    scopus 로고
    • Systematic accuracy and precision analysis of video motion capturing systems - Exemplified on the Vicon-460 system
    • Windolf M, Gotzen N, Morlock M. Systematic accuracy and precision analysis of video motion capturing systems - exemplified on the Vicon-460 system. J Biomech. 2008 ; 41 (12). 2776-2780
    • (2008) J Biomech , vol.41 , Issue.12 , pp. 2776-2780
    • Windolf, M.1    Gotzen, N.2    Morlock, M.3
  • 15
    • 33845197308 scopus 로고    scopus 로고
    • Accuracy and repeatability of an optical motion analysis system for measuring small deformations of biological tissues
    • DOI 10.1016/j.jbiomech.2005.11.007, PII S0021929005005154
    • Liu H, Holt C, Evans S. Accuracy and repeatability of an optical motion analysis system for measuring small deformations of biological tissues. J Biomech. 2007 ; 40 (1). 210-214 (Pubitemid 44848334)
    • (2007) Journal of Biomechanics , vol.40 , Issue.1 , pp. 210-214
    • Liu, H.1    Holt, C.2    Evans, S.3
  • 18
    • 33846309629 scopus 로고    scopus 로고
    • Accuracy of an optical active-marker system to track the relative motion of rigid bodies
    • DOI 10.1016/j.jbiomech.2006.01.017, PII S002192900600042X
    • Maletsky LP, Sun J, Morton NA. Accuracy of an optical active-marker system to track the relative motion of rigid bodies. J Biomech. 2007 ; 40 (3). 682-685 (Pubitemid 46110987)
    • (2007) Journal of Biomechanics , vol.40 , Issue.3 , pp. 682-685
    • Maletsky, L.P.1    Sun, J.2    Morton, N.A.3
  • 19
    • 78651097147 scopus 로고    scopus 로고
    • Precision, repeatability and accuracy of Optotrak optical motion tracking systems
    • Schmidt J, Berg DR, Ploeg H-L. Precision, repeatability and accuracy of Optotrak optical motion tracking systems. Int J Experl Compl Biomech. 2009 ; 1: 114-127
    • (2009) Int J Experl Compl Biomech , vol.1 , pp. 114-127
    • Schmidt, J.1    Berg, D.R.2    Ploeg, H.-L.3
  • 23
    • 0032872135 scopus 로고    scopus 로고
    • Biomechanics of the knee: Methodological considerations in the in vivo kinematic analysis of the tibiofemoral and patellofemoral joint
    • DOI 10.1016/S0268-0033(99)00015-7, PII S0268003399000157
    • Ramsey DK, Wretenberg PF. Biomechanics of the knee: methodological considerations in the in vivo kinematic analysis of the tibiofemoral and patellofemoral joint. Clin Biomech (Bristol, Avon). 1999 ; 14 (9). 595-611 (Pubitemid 29410476)
    • (1999) Clinical Biomechanics , vol.14 , Issue.9 , pp. 595-611
    • Ramsey, D.K.1    Wretenberg, P.F.2
  • 25
    • 0020759032 scopus 로고
    • A joint coordinate system for the clinical description of three-dimensional motions: Application to the knee
    • Grood ES, Suntay WJ. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng. 1983 ; 105 (2). 136-144 (Pubitemid 14160321)
    • (1983) Journal of Biomechanical Engineering , vol.105 , Issue.2 , pp. 136-144
    • Grood, E.S.1    Suntay, W.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.