Volumn 28, Issue 1, 2013, Pages 40-48

Cardiac computed tomography angiography with automatic tube potential selection: Effects on radiation dose and image quality

Author keywords

automatic tube potential; cardiac computed tomography angiography; image quality; radiation dose; tube current selection

Indexed keywords

ADULT; AGED; ALGORITHM; ARTICLE; AUTOMATIC POTENTIAL SELECTION ALGORITHM; BODY MASS; CASE CONTROL STUDY; CLINICAL ARTICLE; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTED TOMOGRAPHY SCANNER; CONTRAST TO NOISE RATIO; CONTROLLED STUDY; CORONARY ARTERY; ELECTRIC POTENTIAL; FEMALE; HEART RATE; HUMAN; IMAGE QUALITY; MALE; RADIATION DOSE; RETROSPECTIVE STUDY; SIGNAL NOISE RATIO;

EID: 84871745189     PISSN: 08835993     EISSN: 15360237     Source Type: Journal    
DOI: 10.1097/RTI.0b013e3182631e8a     Document Type: Article
Times cited : (47)

References (29)
  • 1
    • 33751346679 scopus 로고    scopus 로고
    • Coronary multidetector computed tomography in the assessment of patients with acute chest pain
    • Hoffmann U, Nagurney JT, Moselewski F, et al. Coronary multidetector computed tomography in the assessment of patients with acute chest pain. Circulation. 2006;114:2251-2260.
    • (2006) Circulation , vol.114 , pp. 2251-2260
    • Hoffmann, U.1    Nagurney, J.T.2    Moselewski, F.3
  • 2
    • 69349096036 scopus 로고    scopus 로고
    • Exposure to low-dose ionizing radiation from medical imaging procedures
    • Fazel R, Krumholz HM, Wang Y, et al. Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med. 2009;361:849-857.
    • (2009) N Engl J Med , vol.361 , pp. 849-857
    • Fazel, R.1    Krumholz, H.M.2    Wang, Y.3
  • 3
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography-an increasing source of radiation exposure
    • Brenner DJ, Hall EJ. Computed tomography-an increasing source of radiation exposure. N Engl J Med. 2007;357: 2277-2284.
    • (2007) N Engl J Med , vol.357 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 4
    • 77953328799 scopus 로고    scopus 로고
    • Automatic exposure control in computed tomography-an evaluation of systems from different manufacturers
    • Soderberg M, Gunnarsson M. Automatic exposure control in computed tomography-an evaluation of systems from different manufacturers. Acta Radiol. 2010;51:625-634.
    • (2010) Acta Radiol , vol.51 , pp. 625-634
    • Soderberg, M.1    Gunnarsson, M.2
  • 5
    • 3242787092 scopus 로고    scopus 로고
    • Radiation from "extra" images acquired with abdominal and/or pelvic CT: Effect of automatic tube current modulation
    • Kalra MK, Maher MM, Toth TL, et al. Radiation from "extra" images acquired with abdominal and/or pelvic CT: effect of automatic tube current modulation. Radiology. 2004; 232:409-414.
    • (2004) Radiology , vol.232 , pp. 409-414
    • Kalra, M.K.1    Maher, M.M.2    Toth, T.L.3
  • 6
    • 4644221703 scopus 로고    scopus 로고
    • Sixteen-detector row CT of abdomen and pelvis: Study for optimization of Z-axis modulation technique performed in 153 patients
    • Kalra MK, Maher MM, Kamath RS, et al. Sixteen-detector row CT of abdomen and pelvis: study for optimization of Z-axis modulation technique performed in 153 patients. Radiology. 2004;233:241-249.
    • (2004) Radiology , vol.233 , pp. 241-249
    • Kalra, M.K.1    Maher, M.M.2    Kamath, R.S.3
  • 7
    • 4143148392 scopus 로고    scopus 로고
    • Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters
    • Kalra MK, Maher MM, Blake MA, et al. Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters. Radiology. 2004;232:791-797.
    • (2004) Radiology , vol.232 , pp. 791-797
    • Kalra, M.K.1    Maher, M.M.2    Blake, M.A.3
  • 8
    • 34548174433 scopus 로고    scopus 로고
    • Use of automatic exposure control in multislice computed tomography of the coronaries: Comparison of 16-slice and 64-slice scanner data with conventional coronary angiography
    • Deetjen A, Mollmann S, Conradi G, et al. Use of automatic exposure control in multislice computed tomography of the coronaries: comparison of 16-slice and 64-slice scanner data with conventional coronary angiography. Heart. 2007;93:1040-1043.
    • (2007) Heart , vol.93 , pp. 1040-1043
    • Deetjen, A.1    Mollmann, S.2    Conradi, G.3
  • 9
    • 61349187579 scopus 로고    scopus 로고
    • Application-and patient size-dependent optimization of X-ray spectra for CT
    • Kalender WA, Deak P, Kellermeier M, et al. Application-and patient size-dependent optimization of X-ray spectra for CT. Med Phys. 2009;36:993-1007.
    • (2009) Med Phys , vol.36 , pp. 993-1007
    • Kalender, W.A.1    Deak, P.2    Kellermeier, M.3
  • 10
    • 78249261294 scopus 로고    scopus 로고
    • Image quality and radiation exposure with a low tube voltage protocol for coronary CT angiography results of the PROTECTION II Trial
    • Hausleiter J, Martinoff S, Hadamitzky M, et al. Image quality and radiation exposure with a low tube voltage protocol for coronary CT angiography results of the PROTECTION II Trial. JACC Cardiovasc Imaging. 2010;3:1113-1123.
    • (2010) JACC Cardiovasc Imaging , vol.3 , pp. 1113-1123
    • Hausleiter, J.1    Martinoff, S.2    Hadamitzky, M.3
  • 11
    • 49049083272 scopus 로고    scopus 로고
    • Low kilovoltage cardiac dual-source CT: Attenuation, noise, and radiation dose
    • Leschka S, Stolzmann P, Schmid FT, et al. Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose. Eur Radiol. 2008;18:1809-1817.
    • (2008) Eur Radiol , vol.18 , pp. 1809-1817
    • Leschka, S.1    Stolzmann, P.2    Schmid, F.T.3
  • 12
    • 77952095446 scopus 로고    scopus 로고
    • Radiation exposure and image quality in staged low-dose protocols for coronary dual-source CT angiography: A randomized comparison
    • Pflederer T, Jakstat J, Marwan M, et al. Radiation exposure and image quality in staged low-dose protocols for coronary dual-source CT angiography: a randomized comparison. Eur Radiol. 2010;20:1197-1206.
    • (2010) Eur Radiol , vol.20 , pp. 1197-1206
    • Pflederer, T.1    Jakstat, J.2    Marwan, M.3
  • 13
    • 80054899972 scopus 로고    scopus 로고
    • Coronary CT angiography of patients with a normal body mass index using 80kVp versus 100kVp: A prospective, multicenter, multivendor randomized trial
    • Labounty TM, Leipsic J, Poulter R, et al. Coronary CT angiography of patients with a normal body mass index using 80kVp versus 100kVp: A prospective, multicenter, multivendor randomized trial. Am J Roentgenol. 2011;197:W860-W867.
    • (2011) Am J Roentgenol , vol.197
    • Labounty, T.M.1    Leipsic, J.2    Poulter, R.3
  • 14
    • 59649127716 scopus 로고    scopus 로고
    • Estimated radiation dose associated with cardiac CT angiography
    • Hausleiter J, Meyer T, Hermann F, et al. Estimated radiation dose associated with cardiac CT angiography. JAMA. 2009; 301:500-507.
    • (2009) JAMA , vol.301 , pp. 500-507
    • Hausleiter, J.1    Meyer, T.2    Hermann, F.3
  • 15
    • 33645749654 scopus 로고    scopus 로고
    • Radiation dose estimates from cardiac multislice computed tomography in daily practice: Impact of different scanning protocols on effective dose estimates
    • Hausleiter J, Meyer T, Hadamitzky M, et al. Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation. 2006;113:1305-1310.
    • (2006) Circulation , vol.113 , pp. 1305-1310
    • Hausleiter, J.1    Meyer, T.2    Hadamitzky, M.3
  • 16
    • 77953872454 scopus 로고    scopus 로고
    • Radiation dose reduction by using 100-kV tube voltage in cardiac 64-slice computed tomography: A comparative study
    • Feuchtner GM, Jodocy D, Klauser A, et al. Radiation dose reduction by using 100-kV tube voltage in cardiac 64-slice computed tomography: a comparative study. Eur J Radiol. 2010;75:e51-e56.
    • (2010) Eur J Radiol , vol.75
    • Feuchtner, G.M.1    Jodocy, D.2    Klauser, A.3
  • 17
    • 79958139045 scopus 로고    scopus 로고
    • Use of 100kV versus 120 kV in cardiac dual source computed tomography: Effect on radiation dose and image quality
    • Blankstein R, Bolen MA, Pale R, et al. Use of 100kV versus 120 kV in cardiac dual source computed tomography: effect on radiation dose and image quality. Int J Cardiovasc Imaging. 2011;27:579-586.
    • (2011) Int J Cardiovasc Imaging , vol.27 , pp. 579-586
    • Blankstein, R.1    Bolen, M.A.2    Pale, R.3
  • 18
    • 80055067056 scopus 로고    scopus 로고
    • Direct chest area measurement: A potential anthropometric replacement for BMI to inform cardiac CT dose parameters?
    • Ghoshhajra BB, Engel LC, Major GP, et al. Direct chest area measurement: A potential anthropometric replacement for BMI to inform cardiac CT dose parameters? J Cardiovasc Comput Tomogr. 2011;5:240-246.
    • (2011) J Cardiovasc Comput Tomogr , vol.5 , pp. 240-246
    • Ghoshhajra, B.B.1    Engel, L.C.2    Major, G.P.3
  • 19
    • 73649148717 scopus 로고    scopus 로고
    • Automatic selection of tube potential for radiation dose reduction in CT: A general strategy
    • Yu L, Li H, Fletcher JG, et al. Automatic selection of tube potential for radiation dose reduction in CT: a general strategy. Med Phys. 2010;37:234-243.
    • (2010) Med Phys , vol.37 , pp. 234-243
    • Yu, L.1    Li, H.2    Fletcher, J.G.3
  • 20
    • 81855170190 scopus 로고    scopus 로고
    • Automated attenuation-based tube potential selection for thoracoabdominal computed tomography angiography: Improved dose effectiveness
    • Winklehner A, Goetti R, Baumueller S, et al. Automated attenuation-based tube potential selection for thoracoabdominal computed tomography angiography: improved dose effectiveness. Invest Radiol. 2011;46:767-773.
    • (2011) Invest Radiol , vol.46 , pp. 767-773
    • Winklehner, A.1    Goetti, R.2    Baumueller, S.3
  • 21
    • 1642389455 scopus 로고    scopus 로고
    • Lowkilovoltage multi-detector row chest CT in adults: Feasibility and effect on image quality and iodine dose
    • Sigal-Cinqualbre AB, Hennequin R, Abada HT, et al. Lowkilovoltage multi-detector row chest CT in adults: feasibility and effect on image quality and iodine dose. Radiology. 2004; 231:169-174.
    • (2004) Radiology , vol.231 , pp. 169-174
    • Sigal-Cinqualbre, A.B.1    Hennequin, R.2    Abada, H.T.3
  • 22
    • 80055098779 scopus 로고    scopus 로고
    • SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT
    • Halliburton SS, Abbara S, Chen MY, et al. SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT. J Cardiovasc Comput Tomogr. 2011;5:198-224.
    • (2011) J Cardiovasc Comput Tomogr , vol.5 , pp. 198-224
    • Halliburton, S.S.1    Abbara, S.2    Chen, M.Y.3
  • 23
    • 80054984676 scopus 로고    scopus 로고
    • Iterative reconstruction in image space (IRIS) in cardiac computed tomography: Initial experience
    • Bittencourt MS, Schmidt B, Seltmann M, et al. Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience. Int J Cardiovasc Imaging. 2011;27:1081-1087.
    • (2011) Int J Cardiovasc Imaging , vol.27 , pp. 1081-1087
    • Bittencourt, M.S.1    Schmidt, B.2    Seltmann, M.3
  • 24
    • 0037302020 scopus 로고    scopus 로고
    • Comparison of image quality in contrast-enhanced coronary-artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography
    • Achenbach S, Giesler T, Ropers D, et al. Comparison of image quality in contrast-enhanced coronary-artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography. Invest Radiol. 2003;38:119-128.
    • (2003) Invest Radiol , vol.38 , pp. 119-128
    • Achenbach, S.1    Giesler, T.2    Ropers, D.3
  • 25
    • 84861478737 scopus 로고    scopus 로고
    • Image quality and dose performance of 80 kV low dose scan protocol in high-pitch spiral coronary CT angiography: Feasibility study
    • Wang D, Hu XH, Zhang SZ, et al. Image quality and dose performance of 80 kV low dose scan protocol in high-pitch spiral coronary CT angiography: feasibility study. Int J Cardiovasc Imaging. 2011;28:415-423.
    • (2011) Int J Cardiovasc Imaging , vol.28 , pp. 415-423
    • Wang, D.1    Hu, X.H.2    Zhang, S.Z.3
  • 26
    • 79955015001 scopus 로고    scopus 로고
    • CT dose index and patient dose: They are not the same thing
    • McCollough CH, Leng S, Yu L, et al. CT dose index and patient dose: they are not the same thing. Radiology. 2011;259: 311-316.
    • (2011) Radiology , vol.259 , pp. 311-316
    • McCollough, C.H.1    Leng, S.2    Yu, L.3
  • 27
    • 3242783182 scopus 로고    scopus 로고
    • Comparison of Z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis
    • Kalra MK, Maher MM, Toth TL, et al. Comparison of Z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis. Radiology. 2004;232:347-353.
    • (2004) Radiology , vol.232 , pp. 347-353
    • Kalra, M.K.1    Maher, M.M.2    Toth, T.L.3
  • 28
    • 13244297711 scopus 로고    scopus 로고
    • Techniques and applications of automatic tube current modulation for CT
    • Kalra MK, Maher MM, Toth TL, et al. Techniques and applications of automatic tube current modulation for CT. Radiology. 2004;233:649-657.
    • (2004) Radiology , vol.233 , pp. 649-657
    • Kalra, M.K.1    Maher, M.M.2    Toth, T.L.3
  • 29
    • 77956825812 scopus 로고    scopus 로고
    • Adaptive statistical iterative reconstruction: Assessment of image noise and image quality in coronary CT angiography
    • Leipsic J, Labounty TM, Heilbron B, et al. Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography. Am J Roentgenol. 2010; 195:649-654.
    • (2010) Am J Roentgenol , vol.195 , pp. 649-654
    • Leipsic, J.1    Labounty, T.M.2    Heilbron, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.