메뉴 건너뛰기




Volumn , Issue , 2011, Pages 1890-1895

Mechatronic design of a hand-held instrument with active trocar for laparoscopy

Author keywords

[No Author keywords available]

Indexed keywords

IN-VITRO; MECHATRONIC DESIGN; MINIMALLY INVASIVE; PROOF OF CONCEPT;

EID: 84871697428     PISSN: 10504729     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICRA.2011.5979719     Document Type: Conference Paper
Times cited : (14)

References (24)
  • 1
    • 0036292129 scopus 로고    scopus 로고
    • Comparison of robotic versus laparoscopic skills: Is there a difference in the learning curve?
    • July
    • P. Yohannes, P. Rotariu, P. Pinto, A. D. Smith, and B. R. Lee, "Comparison of robotic versus laparoscopic skills: is there a difference in the learning curve?," Urology, vol. 60, July 2002.
    • (2002) Urology , vol.60
    • Yohannes, P.1    Rotariu, P.2    Pinto, P.3    Smith, A.D.4    Lee, B.R.5
  • 2
    • 0033724356 scopus 로고    scopus 로고
    • The intuitive telesurgery system: Overview and application
    • 1
    • G. Guthart and J. J. Salisbury, "The intuitive telesurgery system: overview and application," Proceedings of ICRA '00, vol. 1, pp. 618-621 vol.1, 2000.
    • (2000) Proceedings of ICRA '00 , vol.1 , pp. 618-621
    • Guthart, G.1    Salisbury, J.J.2
  • 8
    • 0035565257 scopus 로고    scopus 로고
    • Deflectable and rotatable endoscopic instrument with intuitive control
    • November
    • D. Gossot and G. Lange, "Deflectable and rotatable endoscopic instrument with intuitive control," Minimally Invasive Therapy & Allied Technologies, vol. 10, pp. 295-299, November 2001.
    • (2001) Minimally Invasive Therapy & Allied Technologies , vol.10 , pp. 295-299
    • Gossot, D.1    Lange, G.2
  • 10
    • 0031255577 scopus 로고    scopus 로고
    • Deflectable endoscopic instrument system DENIS
    • 10.1007/s004649900523
    • A. Melzer, K. Kipfmüller, and B. Halfar, "Deflectable endoscopic instrument system DENIS," Surgical Endoscopy, vol. 11, pp. 1045-1051, 1997. 10.1007/s004649900523.
    • (1997) Surgical Endoscopy , vol.11 , pp. 1045-1051
    • Melzer, A.1    Kipfmüller, K.2    Halfar, B.3
  • 15
    • 80051544970 scopus 로고    scopus 로고
    • Robotic hand-held surgical device evaluation of end-effectors kinematics and developpement of proof-of-concept prototypes
    • Sept.
    • A. Hassan Zahraee, J. K. Paik, J. Szewczyk, and G. Morel, "Robotic hand-held surgical device evaluation of end-effectors kinematics and developpement of proof-of-concept prototypes," Proceedings of MICCAI '10, Sept. 2010.
    • (2010) Proceedings of MICCAI '10
    • Hassan Zahraee, A.1    Paik, J.K.2    Szewczyk, J.3    Morel, G.4
  • 16
    • 0032091742 scopus 로고    scopus 로고
    • An ergonomic comparison of in-line vs pistol-grip handle configuration in a laparo-scopic grasper
    • 10.1007/s004649900717
    • R. Berguer, S. Gerber, G. Kilpatrick, and D. Beckley, "An ergonomic comparison of in-line vs pistol-grip handle configuration in a laparo-scopic grasper," Surgical Endoscopy, vol. 12, pp. 805-808, 1998. 10.1007/s004649900717.
    • (1998) Surgical Endoscopy , vol.12 , pp. 805-808
    • Berguer, R.1    Gerber, S.2    Kilpatrick, G.3    Beckley, D.4
  • 17
    • 0032896127 scopus 로고    scopus 로고
    • Instruments for minimally invasive surgery: Principles of ergonomic handles
    • 10.1007/s004649900934
    • U. Matern and P. Waller, "Instruments for minimally invasive surgery: principles of ergonomic handles," Surgical Endoscopy, vol. 13, pp. 174-182, 1999. 10.1007/s004649900934.
    • (1999) Surgical Endoscopy , vol.13 , pp. 174-182
    • Matern, U.1    Waller, P.2
  • 18
    • 0032794128 scopus 로고    scopus 로고
    • MIS instruments. An experimental comparison of various ergonomic handles and their design
    • 10.1007/s004649901093
    • U. Matern, M. Eichenlaub, P. Waller, and K. D. Rückauer, "MIS instruments. an experimental comparison of various ergonomic handles and their design," Surgical Endoscopy, vol. 13, pp. 756-762, 1999. 10.1007/s004649901093.
    • (1999) Surgical Endoscopy , vol.13 , pp. 756-762
    • Matern, U.1    Eichenlaub, M.2    Waller, P.3    Rückauer, K.D.4
  • 19
    • 0036135137 scopus 로고    scopus 로고
    • Improved usability of a new handle design for laparo-scopic dissection forceps
    • 10.1007/s004640090102
    • M. A. Veelen, D. W. Meijer, R. H. Goossens, C. J. Snijders, and J. J. Jakimowicz, "Improved usability of a new handle design for laparo-scopic dissection forceps," Surgical Endoscopy, vol. 16, pp. 201-207, 2002. 10.1007/s004640090102.
    • (2002) Surgical Endoscopy , vol.16 , pp. 201-207
    • Veelen, M.A.1    Meijer, D.W.2    Goossens, R.H.3    Snijders, C.J.4    Jakimowicz, J.J.5
  • 20
    • 0347628944 scopus 로고    scopus 로고
    • Optimal angle between instrument shaft and handle for laparoscopic bowel suturing
    • Jan.
    • S. Ahmed, G. Hanna, and A. Cuschieri, "Optimal angle between instrument shaft and handle for laparoscopic bowel suturing," Archives of Surgery, vol. 139, Jan. 2004.
    • (2004) Archives of Surgery , vol.139
    • Ahmed, S.1    Hanna, G.2    Cuschieri, A.3
  • 21
    • 84871681477 scopus 로고    scopus 로고
    • Development of a miniature robot finger with a variable stiffness mechanism using shape memory
    • Aug.
    • Q. México and T. Hino, "Development of a miniature robot finger with a variable stiffness mechanism using shape memory," International Simposium on Robotics and Automation, Aug. 2004.
    • (2004) International Simposium on Robotics and Automation
    • México, Q.1    Hino, T.2
  • 22
    • 0142123045 scopus 로고    scopus 로고
    • Control of shape memory alloy actuator using pulse width modulation
    • N. Ma and G. SONG, "Control of shape memory alloy actuator using pulse width modulation," Smart materials and structures, vol. 12, no. 5, pp. 712-719, 2003.
    • (2003) Smart Materials and Structures , vol.12 , Issue.5 , pp. 712-719
    • Ma, N.1    Song, G.2
  • 24
    • 34548310420 scopus 로고    scopus 로고
    • Design and characterization of a novel hybrid actuator using shape memory alloy and dc micromotor for minimally invasive surgery applications
    • IEEE/ASME Transactions on Aug.
    • V. Kode and M. Cavusoglu, "Design and characterization of a novel hybrid actuator using shape memory alloy and dc micromotor for minimally invasive surgery applications," Mechatronics, IEEE/ASME Transactions on, vol. 12, pp. 455-464, Aug. 2007.
    • (2007) Mechatronics , vol.12 , pp. 455-464
    • Kode, V.1    Cavusoglu, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.