메뉴 건너뛰기




Volumn 12, Issue 12, 2012, Pages 16907-16919

Textile electrodes for EEG recording - a pilot study

Author keywords

EEG; Electrodes; Smart textiles; Textrodes

Indexed keywords

CONDUCTIVE TEXTILES; FREQUENCY DISTRIBUTIONS; LONG TERM MONITORING; MONITORING APPLICATIONS; NEONATAL INTENSIVE CARE UNITS; POWERLINE INTERFERENCE; SMART TEXTILES; TEXTRODES;

EID: 84871694481     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s121216907     Document Type: Article
Times cited : (116)

References (23)
  • 3
    • 80052857741 scopus 로고    scopus 로고
    • Prognostic Capacity of Automated Quantification of Suppression Time in the EEG of Post-Asphyctic Full-Term Neonates
    • Flisberg, A.; Kjellmer, I.; Löfhede, J.; Lindecrantz, K.; Thordstein, M. Prognostic Capacity of Automated Quantification of Suppression Time in the EEG of Post-Asphyctic Full-Term Neonates. Acta Paediatr. 2011, 100, 1338-1343.
    • (2011) Acta Paediatr. , vol.100 , pp. 1338-1343
    • Flisberg, A.1    Kjellmer, I.2    Löfhede, J.3    Lindecrantz, K.4    Thordstein, M.5
  • 6
    • 37549028073 scopus 로고    scopus 로고
    • High-Fidelity Recording of Brain Activity in the Extremely Preterm Babies: Feasibility Study in the Incubator
    • Vanhatalo, S.; Metsäranta, M.; Andersson, S. High-Fidelity Recording of Brain Activity in the Extremely Preterm Babies: Feasibility Study in the Incubator. Clin. Neurophys. 2008, 119, 439-445.
    • (2008) Clin. Neurophys. , vol.119 , pp. 439-445
    • Vanhatalo, S.1    Metsäranta, M.2    Andersson, S.3
  • 9
    • 35848931902 scopus 로고    scopus 로고
    • Novel Dry Electrodes for ECG Monitoring
    • doi:10.1088/0967-3334/28/11/005
    • Gruetzmann, A.; Hansen, S.; Müller, J. Novel Dry Electrodes for ECG Monitoring. Phys. Meas. 2007, 28, doi:10.1088/0967-3334/28/11/005.
    • (2007) Phys. Meas. , vol.28
    • Gruetzmann, A.1    Hansen, S.2    Müller, J.3
  • 10
    • 78649250715 scopus 로고    scopus 로고
    • Brain-Computer Interface Using Water-Based Electrodes
    • doi:10.1088/1741-2560/7/6/066007
    • Volosyak, I.; Valbuena, D.; Malechka, T.; Peuscher, J.; Gräser, A. Brain-Computer Interface Using Water-Based Electrodes. J. Neur. Eng. 2010, 7, doi:10.1088/1741-2560/7/6/066007.
    • (2010) J. Neur. Eng. , vol.7
    • Volosyak, I.1    Valbuena, D.2    Malechka, T.3    Peuscher, J.4    Gräser, A.5
  • 14
    • 0034233563 scopus 로고    scopus 로고
    • Nonlinear Transient Response of Electrode-Electrolyte Interfaces
    • McAdams, E.T.; Jossinet, J. Nonlinear Transient Response of Electrode-Electrolyte Interfaces. Med. Biol. Eng. Comput. 2000, 38, 427-432.
    • (2000) Med. Biol. Eng. Comput. , vol.38 , pp. 427-432
    • McAdams, E.T.1    Jossinet, J.2
  • 15
    • 0004106890 scopus 로고    scopus 로고
    • 3rd ed., John Wiley & Sons: New York, NY, USA
    • Webster, J.G. Medical Instrumentation, 3rd ed.; John Wiley & Sons: New York, NY, USA, 1998.
    • (1998) Medical Instrumentation
    • Webster, J.G.1
  • 20
    • 84864687330 scopus 로고    scopus 로고
    • Biomedical Electrodes for Biopotential Monitoring and Electrostimulation
    • In, Yoo, H.J., van Hoof, C., Eds.; Springer: New York, NY, USA
    • McAdams, E. Biomedical Electrodes for Biopotential Monitoring and Electrostimulation. In Bio-Medical CMOS ICs, Integrated Circuits and Systems; Yoo, H.J., van Hoof, C., Eds.; Springer: New York, NY, USA, 2011.
    • (2011) Bio-Medical CMOS ICs, Integrated Circuits and Systems
    • McAdams, E.1
  • 21
    • 0034048104 scopus 로고    scopus 로고
    • A Direct Comparison of Wet, Dry and Insulating Bioelectric Recording Electrodes
    • Searle, A.; Kirkup, L. A Direct Comparison of Wet, Dry and Insulating Bioelectric Recording Electrodes. Phys. Meas. 2000, 21, 271-283.
    • (2000) Phys. Meas. , vol.21 , pp. 271-283
    • Searle, A.1    Kirkup, L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.