메뉴 건너뛰기




Volumn 2, Issue , 2003, Pages 1758-1761

Fabric sensors for the measurement of physiological parameters

Author keywords

Circuit noise; Electrocardiography; Electrodes; Fabrics; Impedance; Instruments; Intelligent sensors; Low frequency noise; Signal to noise ratio; Textiles

Indexed keywords

ACTUATORS; DATA HANDLING; DIGITAL STORAGE; ELECTRIC IMPEDANCE; ELECTROCARDIOGRAPHY; ELECTRODES; FABRICS; INSTRUMENTS; MICROSYSTEMS; PHYSIOLOGICAL MODELS; SIGNAL TO NOISE RATIO; SMART TEXTILES; TEXTILES; TRANSDUCERS;

EID: 79951632153     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/SENSOR.2003.1217126     Document Type: Conference Paper
Times cited : (25)

References (8)
  • 1
    • 4344655000 scopus 로고    scopus 로고
    • Measurement of respiratory and cardiac function by the LifeShirtTM: Intial assessment of usability and reliability during ambulatory sleep monitoring
    • F.H. Wilhelm, E. Handke & W.T. Roth, "Measurement of respiratory and cardiac function by the LifeShirtTM: intial assessment of usability and reliability during ambulatory sleep monitoring", Biological Psychology, vol. 59, 2002, pp. 250-251.
    • (2002) Biological Psychology , vol.59 , pp. 250-251
    • Wilhelm, F.H.1    Handke, E.2    Roth, W.T.3
  • 2
    • 0018611949 scopus 로고
    • A model of bioelectrode motion artefact and reduction of artefact by amplifier input stage design
    • P. Zipp & H. Ahrens, "A model of bioelectrode motion artefact and reduction of artefact by amplifier input stage design", J. Biomed. Eng., vol. 1, 1979, pp. 273-276.
    • (1979) J. Biomed. Eng. , vol.1 , pp. 273-276
    • Zipp, P.1    Ahrens, H.2
  • 3
    • 0016949544 scopus 로고
    • Method for recording electrocardiograms with dry electrodes applied to unprepared skin
    • R.P. Betts & B.H. Brown, "Method for recording electrocardiograms with dry electrodes applied to unprepared skin", Med. & Biol. Eng., vol. 13, 1976, pp. 313-315.
    • (1976) Med. & Biol. Eng. , vol.13 , pp. 313-315
    • Betts, R.P.1    Brown, B.H.2
  • 5
    • 0019225385 scopus 로고
    • Ground-Free ECG Recording with Two Electrodes
    • December
    • N.V. Thakor & J.G. Webster, "Ground-Free ECG Recording with Two Electrodes", IEEE Trans. Biomed. Eng., vol. 27, no. 12, December 1980, pp. 699-704.
    • (1980) IEEE Trans. Biomed. Eng. , vol.27 , Issue.12 , pp. 699-704
    • Thakor, N.V.1    Webster, J.G.2
  • 6
    • 0020641935 scopus 로고
    • Driven-Right-Leg Circuit Design
    • January
    • B.B. Winter & J.G. Webster, "Driven-Right-Leg Circuit Design", IEEE Trans. Biomed. Eng., vol. 30, no. 1, January 1983, pp. 62-66.
    • (1983) IEEE Trans. Biomed. Eng. , vol.30 , Issue.1 , pp. 62-66
    • Winter, B.B.1    Webster, J.G.2
  • 7
    • 0023759143 scopus 로고
    • Simultaneous Quantification of Chest Wall Distortion by Multiple Methods in Preterm Infants
    • G.P. Heldt, "Simultaneous Quantification of Chest Wall Distortion by Multiple Methods in Preterm Infants", Am. Rev. Respir. Dis., vol. 138, 1988, pp. 120-125.
    • (1988) Am. Rev. Respir. Dis. , vol.138 , pp. 120-125
    • Heldt, G.P.1
  • 8
    • 0028028458 scopus 로고
    • Evaluation of three different techniques used to measure chest wall movements in children
    • R.I. Ross Russel & P.J. Helms, "Evaluation of three different techniques used to measure chest wall movements in children", Eur. Respir. J., vol. 7, 1994, pp. 2073-2076.
    • (1994) Eur. Respir. J. , vol.7 , pp. 2073-2076
    • Ross Russel, R.I.1    Helms, P.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.