메뉴 건너뛰기




Volumn 12, Issue 5, 2012, Pages

Medical imaging and computer-aided flow analysis of a heart with atrial septal defect

Author keywords

atrial septal defect; cardiac flow analysis; computational fluid dynamics; Magnetic resonance fluid motion tracking; right atrium; vorticity

Indexed keywords

CARDIAC CHAMBERS; FLOW ANALYSIS; FLOW MAPS; FLUID MOTIONS; MAGNETIC RESONANCE IMAGES; MR IMAGING; MR SIGNALS; QUANTITATIVE ASSESSMENTS; RIGHT ATRIUM; SCAN MODE; SEPTAL DEFECT; SINGLE VORTICES; VELOCITY FIELD; VELOCITY MAPS; VORTEX STRENGTH; VORTICAL FLOWS;

EID: 84871537497     PISSN: 02195194     EISSN: None     Source Type: Journal    
DOI: 10.1142/S0219519412500248     Document Type: Article
Times cited : (6)

References (48)
  • 2
  • 3
  • 6
    • 33746862145 scopus 로고    scopus 로고
    • The effect of vortex formation on left ventricular filling and mitral valve efficiency
    • Pierrakos O, Vlachos PP, The effect of vortex formation on left ventricular filling and mitral valve efficiency, J Biomech Eng 128:527-539, 2006.
    • (2006) J Biomech Eng , vol.128 , pp. 527-539
    • Pierrakos, O.1    Vlachos, P.P.2
  • 7
    • 0031714140 scopus 로고    scopus 로고
    • Vortical fiow feature recognition: A topological study of in-vivo fiow patterns using MR velocity mapping
    • Yang GZ, Mohiaddin RH, Kilner PJ, Firmin DN, Vortical fiow feature recognition: A topological study of in-vivo fiow patterns using MR velocity mapping, J Comput Assist Tomogr 22:577-586, 1998.
    • (1998) J Comput Assist Tomogr , vol.22 , pp. 577-586
    • Yang, G.Z.1    Mohiaddin, R.H.2    Kilner, P.J.3    Firmin, D.N.4
  • 8
    • 33749621392 scopus 로고    scopus 로고
    • Atrial septal defects in the adult-Recent progess and overview
    • Webb G, Gatzoulis MA, Atrial septal defects in the adult-Recent progess and overview, Circulation 114:1645-1653, 2006.
    • (2006) Circulation , vol.114 , pp. 1645-1653
    • Webb, G.1    Gatzoulis, M.A.2
  • 10
    • 0036481560 scopus 로고    scopus 로고
    • Recommendations for quantification of Doppler echocardiography: A report from the Doppler quantification task force of the nonmenclature and standards committee of the American Society of echocardiography
    • Quinones MA, Otto CM, Stoddard M, Waggoner A, Zoghbi WA, Recommendations for quantification of Doppler echocardiography: A report from the Doppler quantification task force of the nonmenclature and standards committee of the American Society of echocardiography, J Am Soc Echocardiogr 15:167-184, 2002.
    • (2002) J Am Soc Echocardiogr , vol.15 , pp. 167-184
    • Quinones, M.A.1    Otto, C.M.2    Stoddard, M.3    Waggoner, A.4    Zoghbi, W.A.5
  • 11
    • 1042298885 scopus 로고    scopus 로고
    • Accuracy of spectral Doppler fiow and tissue velocity measurements in ultrasound systems
    • Walker A, Olsson E, Wranne B, Ringqvist I, Ask P, Accuracy of spectral Doppler fiow and tissue velocity measurements in ultrasound systems, Ultrasound Med Biol 30:127-132, 2004.
    • (2004) Ultrasound Med Biol , vol.30 , pp. 127-132
    • Walker, A.1    Olsson, E.2    Wranne, B.3    Ringqvist, I.4    Ask, P.5
  • 12
    • 33750958159 scopus 로고    scopus 로고
    • Left ventricular isovolumic fiow sequence during sinus and paced rhythm: New insights from use of high-resolution Doppler and ultrasonic digital particle imaging velocimetry
    • Sengupta PP, Khandheria BK, Korinek L, Jahangir A, Yoshifuku S, Milosevic I, Belohlavek M, Left ventricular isovolumic fiow sequence during sinus and paced rhythm: New insights from use of high-resolution Doppler and ultrasonic digital particle imaging velocimetry, J Am Coll Cardiol 49:899-908, 2007.
    • (2007) J Am Coll Cardiol , vol.49 , pp. 899-908
    • Sengupta, P.P.1    Khandheria, B.K.2    Korinek, L.3    Jahangir, A.4    Yoshifuku, S.5    Milosevic, I.6    Belohlavek, M.7
  • 14
    • 0028656433 scopus 로고
    • Diagnosis in adolescents and adults with congenital heart disease, Prospective assessment of individual and combined roles of magnetic resonance imaging and transesophageal echocardiography
    • Hirsch R, Kilner PJ, Connelly MS, Redington AN, St John Sutton MG, Somerville J, Diagnosis in adolescents and adults with congenital heart disease, Prospective assessment of individual and combined roles of magnetic resonance imaging and transesophageal echocardiography, Circulation 90:2937-2951, 1994.
    • (1994) Circulation , vol.90 , pp. 2937-2951
    • Hirsch, R.1    Kilner, P.J.2    Connelly, M.S.3    Redington, A.N.4    St John Sutton, M.G.5    Somerville, J.6
  • 15
    • 0029979046 scopus 로고    scopus 로고
    • Congenital heart disease in adults and adolescents: Comparative value of transthoracic and transesophageal echocardiography and MR imaging
    • Hoppe UC, Dederichs B, Deutsch HJ, Theissen P, Schicha H, Sechtem U, Congenital heart disease in adults and adolescents: Comparative value of transthoracic and transesophageal echocardiography and MR imaging, Radiology 199:669-677, 1996.
    • (1996) Radiology , vol.199 , pp. 669-677
    • Hoppe, U.C.1    Dederichs, B.2    Deutsch, H.J.3    Theissen, P.4    Schicha, H.5    Sechtem, U.6
  • 17
    • 0037256212 scopus 로고    scopus 로고
    • Differential diagnosis of arachnoid cyst from subarachnoid space enlargement by phase-contrast cine MRI
    • Yu YQ, Kong X, Liu D, Differential diagnosis of arachnoid cyst from subarachnoid space enlargement by phase-contrast cine MRI, Chin Med J 116:116-120, 2003.
    • (2003) Chin Med J , vol.116 , pp. 116-120
    • Yu, Y.Q.1    Kong, X.2    Liu, D.3
  • 18
    • 84871584987 scopus 로고
    • Phillips Philips Medical Systems Clinical Education
    • Phillips, Philips Medical Systems Clinical Education, Basic principles of MR imaging, 1984.
    • (1984) Basic Principles of MR Imaging
  • 19
    • 0018967289 scopus 로고
    • Non-invasive diagnosis in clinically suspected atrial septal defect of secundum or sinus venosus type, Value of combining chest X-ray, phonocardiography, and M-mode echocardiography
    • Egeblad EH, Berning J, Efsen F, Wennevold A, Non-invasive diagnosis in clinically suspected atrial septal defect of secundum or sinus venosus type, Value of combining chest X-ray, phonocardiography, and M-mode echocardiography, Br Heart J 44:317-321, 1980.
    • (1980) Br Heart J , vol.44 , pp. 317-321
    • Egeblad, E.H.1    Berning, J.2    Efsen, F.3    Wennevold, A.4
  • 21
    • 33750313558 scopus 로고    scopus 로고
    • Diagnostic value of multislice CT angiography in coronary artery disease: A meta-analysis
    • Sun Z, Jiang W, Diagnostic value of multislice CT angiography in coronary artery disease: A meta-analysis, Eur J Radiol 60:279-286, 2006.
    • (2006) Eur J Radiol , vol.60 , pp. 279-286
    • Sun, Z.1    Jiang, W.2
  • 22
    • 44949261056 scopus 로고    scopus 로고
    • Diagnostic value of 64-slice CT angiography in coronary artery disease: A systematic review
    • Sun Z, Lin CH, Davidson R, Dong C, Liao Y, Diagnostic value of 64-slice CT angiography in coronary artery disease: A systematic review, Eur J Radiol 67:78-84, 2007.
    • (2007) Eur J Radiol , vol.67 , pp. 78-84
    • Sun, Z.1    Lin, C.H.2    Davidson, R.3    Dong, C.4    Liao, Y.5
  • 23
    • 77953516026 scopus 로고    scopus 로고
    • Multislice CT angiography in the cardiac imaging, Part II: Diagnostic applications in coronary artery disease
    • Sun Z, Ng KH, Multislice CT angiography in the cardiac imaging, Part II: Diagnostic applications in coronary artery disease, Singapore Med J 51:282-289, 2010.
    • (2010) Singapore Med J , vol.51 , pp. 282-289
    • Sun, Z.1    Ng, K.H.2
  • 25
    • 84976670463 scopus 로고
    • The computation of optical fiow
    • Barron JL, Beauchemin Ss, The computation of optical fiow, ACM Computing Surveys 27:434-465, 1995.
    • (1995) ACM Computing Surveys , vol.27 , pp. 434-465
    • Barron, J.L.1    Ss, B.2
  • 28
    • 0024551349 scopus 로고
    • Human abdominal aorta: Comparative measurements of blood fiow with MR imaging and multigated Doppler US
    • Maier SE, Meier D, Boesiger P, Moser UT, Vieli A, Human abdominal aorta: Comparative measurements of blood fiow with MR imaging and multigated Doppler US, Radiology 171:487-492, 1989.
    • (1989) Radiology , vol.171 , pp. 487-492
    • Maier, S.E.1    Meier, D.2    Boesiger, P.3    Moser, U.T.4    Vieli, A.5
  • 29
    • 0034016549 scopus 로고    scopus 로고
    • Phase-velocity cine magnetic resonance imaging measurement of pulsatile blood fiow in children and young adults: In vitro and in vivo validation
    • Powell AJ, Maier SE, Chung T, Geva T, Phase-velocity cine magnetic resonance imaging measurement of pulsatile blood fiow in children and young adults: In vitro and in vivo validation, Pediatr Cardiol 21:104-110, 2000.
    • (2000) Pediatr Cardiol , vol.21 , pp. 104-110
    • Powell, A.J.1    Maier, S.E.2    Chung, T.3    Geva, T.4
  • 30
    • 0036584937 scopus 로고    scopus 로고
    • Cardiovascular fiow measurement with phasecontrast MR imaging: Basic facts and implementation
    • Lotz J, Meier C, Leppert A, Galanski M, Cardiovascular fiow measurement with phasecontrast MR imaging: Basic facts and implementation, Radiographics 22:651-671, 2002.
    • (2002) Radiographics , vol.22 , pp. 651-671
    • Lotz, J.1    Meier, C.2    Leppert, A.3    Galanski, M.4
  • 32
    • 11244302808 scopus 로고    scopus 로고
    • Full field velocity and temperature measurements using magnetic resonance imaging in turbulent complex internal fiows
    • Elkins CJ, Markl M, Iyengar A, Wicker R, Eaton J, Full field velocity and temperature measurements using magnetic resonance imaging in turbulent complex internal fiows, Int J Heat Fluid Fl 25:702-710, 2004.
    • (2004) Int J Heat Fluid Fl , vol.25 , pp. 702-710
    • Elkins, C.J.1    Markl, M.2    Iyengar, A.3    Wicker, R.4    Eaton, J.5
  • 37
    • 0033804590 scopus 로고    scopus 로고
    • Computational modeling of left heart diastolic function: Examination of ventricular dysfunction
    • Lemmon JD, Yoganathan AP, Computational modeling of left heart diastolic function: Examination of ventricular dysfunction, J Biomech Eng 122:297-303, 2000.
    • (2000) J Biomech Eng , vol.122 , pp. 297-303
    • Lemmon, J.D.1    Yoganathan, A.P.2
  • 38
    • 0031281394 scopus 로고    scopus 로고
    • Computational approach for probing the fiow through artificial heart devices
    • Kiris C, Kwak D, Rogers S, Chang ID, Computational approach for probing the fiow through artificial heart devices, J Biomech Eng 119:452-460, 1997.
    • (1997) J Biomech Eng , vol.119 , pp. 452-460
    • Kiris, C.1    Kwak, D.2    Rogers, S.3    Chang, I.D.4
  • 39
    • 0041375626 scopus 로고    scopus 로고
    • Comparative study of magnetic resonance imaging and image-based computational fiuid dynamics for quanti-fication of pulsatile fiow in a carotid bifurcation phantom
    • Zhao SZ, Papathanasopoulou P, Long Q, Marshall I, Xu XY, Comparative study of magnetic resonance imaging and image-based computational fiuid dynamics for quanti-fication of pulsatile fiow in a carotid bifurcation phantom, Ann Biomed Eng 31:962-971, 2003.
    • (2003) Ann Biomed Eng , vol.31 , pp. 962-971
    • Zhao, S.Z.1    Papathanasopoulou, P.2    Long, Q.3    Marshall, I.4    Xu, X.Y.5
  • 40
    • 0011212712 scopus 로고
    • Measuring distributions of diffusivity in turbulent fiuids with magneticresonance imaging
    • Kuethe DO, Measuring distributions of diffusivity in turbulent fiuids with magneticresonance imaging, Phys Rev A 40:4542-4551, 1989.
    • (1989) Phys Rev A , vol.40 , pp. 4542-4551
    • Kuethe, D.O.1
  • 48
    • 84865567210 scopus 로고    scopus 로고
    • Medical image diagnostics based on computer-aided fiow analysis using magnetic resonance images
    • (Epub ahead of print)10. 1016/j.compmedimag.2012.04.003
    • Wong KK, Sun Z, Yu J, Worthley SG, Mazumdar J, Abbott D, Medical image diagnostics based on computer-aided fiow analysis using magnetic resonance images, Comput Med Imaging Graph (Epub ahead of print) 10. 1016/j.compmedimag. 2012. 04. 003
    • Comput Med Imaging Graph
    • Wong, K.K.1    Sun, Z.2    Yu, J.3    Worthley, S.G.4    Mazumdar, J.5    Abbott, D.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.