메뉴 건너뛰기




Volumn 27, Issue 2, 2013, Pages 325-332

Investigations of chemical warfare agents and toxic industrial compounds with proton-transfer-reaction mass spectrometry for a real-time threat monitoring scenario

Author keywords

[No Author keywords available]

Indexed keywords

AIR CONDITIONING; ALARM SYSTEMS; CHEMICAL WARFARE; COST EFFECTIVENESS; MASS SPECTROMETRY; PROTON TRANSFER;

EID: 84871278659     PISSN: 09514198     EISSN: 10970231     Source Type: Journal    
DOI: 10.1002/rcm.6456     Document Type: Article
Times cited : (21)

References (28)
  • 1
    • 71949106768 scopus 로고    scopus 로고
    • Real-time trace detection and identification of chemical warfare agent simulants using recent advances in proton transfer reaction time-of-flight mass spectrometry
    • F. Petersson, P. Sulzer, C. A. Mayhew, P. Watts, A. Jordan, L. Märk, T. D. Märk,. Real-time trace detection and identification of chemical warfare agent simulants using recent advances in proton transfer reaction time-of-flight mass spectrometry. Rapid Commun. Mass Spectrom. 2009, 23, 3875.
    • (2009) Rapid Commun. Mass Spectrom. , vol.23 , pp. 3875
    • Petersson, F.1    Sulzer, P.2    Mayhew, C.A.3    Watts, P.4    Jordan, A.5    Märk, L.6    Märk, T.D.7
  • 2
    • 71649100837 scopus 로고    scopus 로고
    • Applications of proton transfer reaction time-of-flight mass spectrometry for the sensitive and rapid real-time detection of solid high explosives
    • C. A. Mayhew, P. Sulzer, F. Petersson, S. Haidacher, A. Jordan, L. Märk, P. Watts, T. D. Märk,. Applications of proton transfer reaction time-of-flight mass spectrometry for the sensitive and rapid real-time detection of solid high explosives. Int. J. Mass Spectrom. 2010, 289, 58.
    • (2010) Int. J. Mass Spectrom. , vol.289 , pp. 58
    • Mayhew, C.A.1    Sulzer, P.2    Petersson, F.3    Haidacher, S.4    Jordan, A.5    Märk, L.6    Watts, P.7    Märk, T.D.8
  • 4
    • 79958169796 scopus 로고    scopus 로고
    • Use of proton transfer reaction time-of-flight mass spectrometry for the analytical detection of illicit and controlled prescription drugs at room temperature via direct headspace sampling
    • B. Agarwal, F. Petersson, S. Jürschik, P. Sulzer, A. Jordan, T. D. Märk, P. Watts, C. A. Mayhew,. Use of proton transfer reaction time-of-flight mass spectrometry for the analytical detection of illicit and controlled prescription drugs at room temperature via direct headspace sampling. Anal. Bioanal. Chem. 2011, 400, 2631.
    • (2011) Anal. Bioanal. Chem. , vol.400 , pp. 2631
    • Agarwal, B.1    Petersson, F.2    Jürschik, S.3    Sulzer, P.4    Jordan, A.5    Märk, T.D.6    Watts, P.7    Mayhew, C.A.8
  • 6
    • 84866424005 scopus 로고    scopus 로고
    • Rapid and facile detection of four " date rape drugs" in different beverages utilizing Proton-Transfer-Reaction Mass Spectrometry (PTR-MS)
    • S. Jürschik, B. Agarwal, T. Kassebacher, P. Sulzer, C. A. Mayhew, T. D. Märk,. Rapid and facile detection of four " date rape drugs" in different beverages utilizing Proton-Transfer-Reaction Mass Spectrometry (PTR-MS). J. Mass Spectrom. 2012, 47, 1092.
    • (2012) J. Mass Spectrom. , vol.47 , pp. 1092
    • Jürschik, S.1    Agarwal, B.2    Kassebacher, T.3    Sulzer, P.4    Mayhew, C.A.5    Märk, T.D.6
  • 8
    • 85159508488 scopus 로고    scopus 로고
    • (accessed on 3.10.2012)
    • http://www.infrastructure-protection.org (accessed on 3.10.2012).
  • 9
    • 85159509365 scopus 로고    scopus 로고
    • (accessed 3.10.2012)
    • http://www.epa.gov/oppt/aegl/index.htm (accessed 3.10.2012).
  • 10
    • 85159510096 scopus 로고    scopus 로고
    • (accessed 3.10.2012)
    • http://www.epa.gov/oppt/aegl/pubs/priority.htm (accessed 3.10.2012).
  • 11
    • 0001286293 scopus 로고
    • The chemistry of the organic isocyanates
    • J. H. Saunders, R. J. Slocombe,. The chemistry of the organic isocyanates. Chem. Rev. 1948, 43 (2), 203.
    • (1948) Chem. Rev. , vol.43 , Issue.2 , pp. 203
    • Saunders, J.H.1    Slocombe, R.J.2
  • 12
    • 0034745528 scopus 로고    scopus 로고
    • Phosgene exposure: Mechanisms of injury and treatment strategies
    • J. Borak, W.F. Diller,. Phosgene exposure: mechanisms of injury and treatment strategies. J. Occup. Environ. Med. 2001, 43 (2), 110.
    • (2001) J. Occup. Environ. Med. , vol.43 , Issue.2 , pp. 110
    • Borak, J.1    Diller, W.F.2
  • 13
    • 0000843067 scopus 로고
    • Trichloromethyl chloroformate. Reaction with amines, amino acids, and amino alcohols
    • K. Kurita, T. Matsumura, Y. Iwakura,. Trichloromethyl chloroformate. Reaction with amines, amino acids, and amino alcohols. J. Org. Chem. 1976, 41, 2070.
    • (1976) J. Org. Chem. , vol.41 , pp. 2070
    • Kurita, K.1    Matsumura, T.2    Iwakura, Y.3
  • 15
    • 0019954840 scopus 로고
    • Injuries after use of the lacrimatory agent chloroacetophenone in a confined space
    • K. Thorburn,. Injuries after use of the lacrimatory agent chloroacetophenone in a confined space. Arch. Environ. Health 1982, 37 (3), 182.
    • (1982) Arch. Environ. Health , vol.37 , Issue.3 , pp. 182
    • Thorburn, K.1
  • 19
    • 7644239317 scopus 로고    scopus 로고
    • Ion mobility spectrometry
    • A
    • K. Cottingham,. Ion mobility spectrometry. Anal. Chem. 2003, 75, 439 A.
    • (2003) Anal. Chem. , vol.75 , pp. 439
    • Cottingham, K.1
  • 20
    • 70350641361 scopus 로고    scopus 로고
    • Detection and quantification of chemical warfare agent precursors and surrogates by selected ion flow tube mass spectrometry
    • G. J. Francis, D. B. Milligan, M. J. McEwan,. Detection and quantification of chemical warfare agent precursors and surrogates by selected ion flow tube mass spectrometry. Anal. Chem. 2009, 81, 8892.
    • (2009) Anal. Chem. , vol.81 , pp. 8892
    • Francis, G.J.1    Milligan, D.B.2    McEwan, M.J.3
  • 21
    • 65249177702 scopus 로고    scopus 로고
    • Proton-transfer reaction mass spectrometry
    • R. S. Blake, P. S. Monks, A. M. Ellis,. Proton-transfer reaction mass spectrometry. Chem. Rev. 2009, 109, 861.
    • (2009) Chem. Rev. , vol.109 , pp. 861
    • Blake, R.S.1    Monks, P.S.2    Ellis, A.M.3
  • 22
    • 33947662474 scopus 로고    scopus 로고
    • Measurement of Volatile Organic Compounds in the Earth's Atmosphere using Proton-Transfer-Reaction Mass Spectrometry
    • J. de Gouw, C. Warneke, T. Karl, G. Eerdekens, C. van der Veen, R. Fall,. Measurement of Volatile Organic Compounds in the Earth's Atmosphere using Proton-Transfer-Reaction Mass Spectrometry. Mass Spectrom. Rev. 2007, 26, 223.
    • (2007) Mass Spectrom. Rev. , vol.26 , pp. 223
    • De Gouw, J.1    Warneke, C.2    Karl, T.3    Eerdekens, G.4    Van Der Veen, C.5    Fall, R.6
  • 25
    • 85159504536 scopus 로고    scopus 로고
    • (accessed 3.10.2012)
    • http://www.ionicon.com/products/index.html (accessed 3.10.2012)
  • 28
    • 10044271359 scopus 로고    scopus 로고
    • On-line monitoring of volatile organic compounds at pptv levels by means of proton-transfer-reaction mass-spectrometry (PTR-MS): Medical applications, food control and environmental research
    • W. Lindinger, A. Hansel, A. Jordan,. On-line monitoring of volatile organic compounds at pptv levels by means of proton-transfer-reaction mass-spectrometry (PTR-MS): Medical applications, food control and environmental research. Int. J. Mass Spectrom. Ion Processes 1998, 173, 191.
    • (1998) Int. J. Mass Spectrom. Ion Processes , vol.173 , pp. 191
    • Lindinger, W.1    Hansel, A.2    Jordan, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.