메뉴 건너뛰기




Volumn 28, Issue 12, 2012, Pages 895-900

Correlation between central corneal thickness, anterior chamber depth, and corneal keratometry as measured by Oculyzer II and WaveLight OB820 in preoperative cataract surgery patients

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANTERIOR EYE CHAMBER DEPTH; ARTICLE; BIOMETRY; CATARACT; CATARACT EXTRACTION; CENTRAL CORNEA THICKNESS; CORNEA THICKNESS; FEMALE; HUMAN; KERATOMETRY; MAJOR CLINICAL STUDY; MALE; OPTICAL INSTRUMENTATION; PREOPERATIVE PERIOD; PRIORITY JOURNAL; REFLECTOMETRY;

EID: 84871265497     PISSN: 1081597X     EISSN: 19382391     Source Type: Journal    
DOI: 10.3928/1081597X-20121005-07     Document Type: Article
Times cited : (22)

References (26)
  • 1
    • 37349012831 scopus 로고    scopus 로고
    • Biometry and intraocular lens power calculation
    • DOI 10.1097/ICU.0b013e3282f1c5ad, PII 0005573520080100000005
    • Lee AC, Qazi MA, Pepose JS. Biometry and intraocular lens power calculation. Curr Opin Ophthalmol. 2008;19(1):13-17. (Pubitemid 350307554)
    • (2008) Current Opinion in Ophthalmology , vol.19 , Issue.1 , pp. 13-17
    • Lee, A.C.1    Qazi, M.A.2    Pepose, J.S.3
  • 2
    • 33646054203 scopus 로고    scopus 로고
    • Prediction of the effective postoperative (intraocular lens) anterior chamber depth
    • Olsen T. Prediction of the effective postoperative (intraocular lens) anterior chamber depth. J Cataract Refract Surg. 2006;32(3):419-424.
    • (2006) J Cataract Refract Surg , vol.32 , Issue.3 , pp. 419-424
    • Olsen, T.1
  • 3
    • 52049110989 scopus 로고    scopus 로고
    • Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula
    • Haigis W. Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula. J Cataract Refract Surg. 2008;34(10):1658-1663.
    • (2008) J Cataract Refract Surg , vol.34 , Issue.10 , pp. 1658-1663
    • Haigis, W.1
  • 4
    • 79952274385 scopus 로고    scopus 로고
    • Accuracy of intraocular lens calculations using the IOLMaster in eyes with long axial length and a comparison of various formulas
    • Bang S, Edell E, Yu Q, Pratzer K, Stark W. Accuracy of intraocular lens calculations using the IOLMaster in eyes with long axial length and a comparison of various formulas. Ophthalmology. 2011;118(3):503-506.
    • (2011) Ophthalmology , vol.118 , Issue.3 , pp. 503-506
    • Bang, S.1    Edell, E.2    Yu, Q.3    Pratzer, K.4    Stark, W.5
  • 5
    • 79959565429 scopus 로고    scopus 로고
    • Accuracy of the Holladay 2 intraocular lens formula for pediatric eyes in the absence of preoperative refraction
    • Trivedi RH, Wilson ME, Reardon W. Accuracy of the Holladay 2 intraocular lens formula for pediatric eyes in the absence of preoperative refraction. J Cataract Refract Surg. 2011;37(7):1239-1243.
    • (2011) J Cataract Refract Surg , vol.37 , Issue.7 , pp. 1239-1243
    • Trivedi, R.H.1    Wilson, M.E.2    Reardon, W.3
  • 6
    • 78650508781 scopus 로고    scopus 로고
    • Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry
    • Aristodemou P, Knox Cartwright NE, Sparrow JM, Johnston RL. Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry. J Cataract Refract Surg. 2011;37(1):63-71.
    • (2011) J Cataract Refract Surg , vol.37 , Issue.1 , pp. 63-71
    • Aristodemou, P.1    Knox Cartwright, N.E.2    Sparrow, J.M.3    Johnston, R.L.4
  • 8
    • 79960128547 scopus 로고    scopus 로고
    • In vivo measurement of central corneal thickness in normal chicks (Gallus gallus domesticus) with the optical low-coherence reflectometer
    • Tappeiner C, Goldblum D, Katsoulis K, Sarra GM, Frueh BE. In vivo measurement of central corneal thickness in normal chicks (Gallus gallus domesticus) with the optical low-coherence reflectometer. Vet Ophthalmol. 2011;14(4):257-261.
    • (2011) Vet Ophthalmol , vol.14 , Issue.4 , pp. 257-261
    • Tappeiner, C.1    Goldblum, D.2    Katsoulis, K.3    Sarra, G.M.4    Frueh, B.E.5
  • 10
    • 0030732713 scopus 로고    scopus 로고
    • Corneal thickness measurements with the Orbscan Topography System and ultrasonic pachymetry
    • Yaylali V, Kaufman SC, Thompson HW. Corneal thickness measurements with the Orbscan topography system and ultrasonic pachymetry. J Cataract Refract Surg. 1997;23(9):1345-1350. (Pubitemid 27524541)
    • (1997) Journal of Cataract and Refractive Surgery , vol.23 , Issue.9 , pp. 1345-1350
    • Yaylali, V.1    Kaufman, S.C.2    Thompson, H.W.3
  • 11
    • 34250648821 scopus 로고    scopus 로고
    • Central corneal thickness measurements using Orbscan II, Visante, ultrasound, and Pentacam pachymetry after laser in situ keratomileusis for myopia
    • DOI 10.1016/j.jcrs.2007.03.028, PII S0886335007005834
    • Ho T, Cheng AC, Rao SK, Lau S, Leung CK, Lam DS. Central corneal thickness measurements using Orbscan II, Visante, ultrasound and Pentacam pachymetry after laser in situ keratomileusis for myopia. J Cataract Refract Surg. 2007;33(7):1177-1182. (Pubitemid 46936129)
    • (2007) Journal of Cataract and Refractive Surgery , vol.33 , Issue.7 , pp. 1177-1182
    • Ho, T.1    Cheng, A.C.K.2    Rao, S.K.3    Lau, S.4    Leung, C.K.S.5    Lam, D.S.C.6
  • 12
    • 72049094509 scopus 로고    scopus 로고
    • Spectral-domain optical coherence tomography: A comparison of modern high-resolution retinal imaging systems
    • Kiernan DF, Mieler WF, Hariprasad SM. Spectral-domain optical coherence tomography: a comparison of modern high-resolution retinal imaging systems. Am J Ophthalmol. 2010;149(1):18-31.
    • (2010) Am J Ophthalmol , vol.149 , Issue.1 , pp. 18-31
    • Kiernan, D.F.1    Mieler, W.F.2    Hariprasad, S.M.3
  • 13
    • 37349056419 scopus 로고    scopus 로고
    • Anterior segment biometry with the Pentacam: Comprehensive assessment of repeatability of automated measurements
    • DOI 10.1016/j.jcrs.2007.09.013, PII S0886335007017725
    • Shankar H, Taranath D, Santhirathelagan CT, Pesudovs K. Anterior segment biometry with the Pentacam: comprehensive assessment of repeatability of automated measurements. J Cataract Refract Surg. 2008;34(1):103-113. (Pubitemid 350299777)
    • (2008) Journal of Cataract and Refractive Surgery , vol.34 , Issue.1 , pp. 103-113
    • Shankar, H.1    Taranath, D.2    Santhirathelagan, C.T.3    Pesudovs, K.4
  • 15
    • 84863772201 scopus 로고    scopus 로고
    • Repeatability and agreement of 2 Scheimpflug analyzers in measuring the central corneal thickness and anterior chamber angle, volume, and depth
    • Bedei A, Appolloni I, Madesani A, Pietrelli A, Franceschi S, Barabesi L. Repeatability and agreement of 2 Scheimpflug analyzers in measuring the central corneal thickness and anterior chamber angle, volume, and depth. Eur J Ophthalmol. 2012;22 Suppl 7:S29-S32.
    • (2012) Eur J Ophthalmol , vol.22 , Issue.SUPPL. 7
    • Bedei, A.1    Appolloni, I.2    Madesani, A.3    Pietrelli, A.4    Franceschi, S.5    Barabesi, L.6
  • 16
    • 84867395264 scopus 로고    scopus 로고
    • Comparison of central corneal thickness measurements with optical low-coherence reflectometry and ultrasound pachymetry and reproducibility of both devices
    • Koktekir BE, Gedik S, Bakbak B. Comparison of central corneal thickness measurements with optical low-coherence reflectometry and ultrasound pachymetry and reproducibility of both devices. Cornea. 2012;31(11):1278-1281.
    • (2012) Cornea , vol.31 , Issue.11 , pp. 1278-1281
    • Koktekir, B.E.1    Gedik, S.2    Bakbak, B.3
  • 17
    • 66749108908 scopus 로고    scopus 로고
    • Accuracy of a new partial coherence interferometry analyser for biometric measurements
    • Holzer MP, Mamusa M, Auffarth GU. Accuracy of a new partial coherence interferometry analyser for biometric measurements. Br J Ophthalmol. 2009;93(6):807-810.
    • (2009) Br J Ophthalmol , vol.93 , Issue.6 , pp. 807-810
    • Holzer, M.P.1    Mamusa, M.2    Auffarth, G.U.3
  • 18
    • 84865508011 scopus 로고    scopus 로고
    • Comparison of central corneal thickness and anterior chamber depth measured using LenStar LS900, Pentacam, and Visante AS-OCT
    • O'Donnell C, Hartwig A, Radhakrishnan H. Comparison of central corneal thickness and anterior chamber depth measured using LenStar LS900, Pentacam, and Visante AS-OCT. Cornea. 2012;31(9):983-988.
    • (2012) Cornea , vol.31 , Issue.9 , pp. 983-988
    • O'Donnell, C.1    Hartwig, A.2    Radhakrishnan, H.3
  • 19
    • 80053439028 scopus 로고    scopus 로고
    • Comparison of the biometric measurements obtained using non-contact optical biometers LenStar LS 900 and IOL Master V.5
    • Kolodziejczyk W, Galecki T, Lazicka-Galecka M, Szaflik J. Comparison of the biometric measurements obtained using non-contact optical biometers LenStar LS 900 and IOL Master V.5. Klin Oczna. 2011;113(1-3):47-51.
    • (2011) Klin Oczna , vol.113 , Issue.1-3 , pp. 47-51
    • Kolodziejczyk, W.1    Galecki, T.2    Lazicka-Galecka, M.3    Szaflik, J.4
  • 22
    • 79953029518 scopus 로고    scopus 로고
    • Comparison between Lenstar LS 900 non-contact biometry and OcuScan RXP contact biometry for task delegation
    • French
    • El Chehab H, Giraud JM, Le Corre A, et al. Comparison between Lenstar LS 900 non-contact biometry and OcuScan RXP contact biometry for task delegation [French]. J Fr Ophtalmol. 2011;34(3):175-180.
    • (2011) J Fr Ophtalmol , vol.34 , Issue.3 , pp. 175-180
    • El Chehab, H.1    Giraud, J.M.2    Le Corre, A.3
  • 23
    • 78751541997 scopus 로고    scopus 로고
    • Comparison of anterior segment measurements with rotating Scheimpflug photography and partial coherence reflectometry
    • Huang J, Pesudovs K, Wen D, et al. Comparison of anterior segment measurements with rotating Scheimpflug photography and partial coherence reflectometry. J Cataract Refract Surg. 2011;37(2):341-348.
    • (2011) J Cataract Refract Surg , vol.37 , Issue.2 , pp. 341-348
    • Huang, J.1    Pesudovs, K.2    Wen, D.3
  • 24
    • 79951945131 scopus 로고    scopus 로고
    • Evaluation of 2 new optical biometry devices and comparison with the current gold standard biometer
    • Chen YA, Hirnschall N, Findl O. Evaluation of 2 new optical biometry devices and comparison with the current gold standard biometer. J Cataract Refract Surg. 2011;37(3):513-517.
    • (2011) J Cataract Refract Surg , vol.37 , Issue.3 , pp. 513-517
    • Chen, Y.A.1    Hirnschall, N.2    Findl, O.3
  • 25
    • 34247193156 scopus 로고    scopus 로고
    • Corneal radii and anterior chamber depth measurements using the IOLMaster versus the pentacam
    • Reuland MS, Reuland AJ, Nishi Y, Auffarth GU. Corneal radii and anterior chamber depth measurements using the IOLmaster versus the Pentacam. J Refract Surg. 2007;23(4):368-373. (Pubitemid 46608848)
    • (2007) Journal of Refractive Surgery , vol.23 , Issue.4 , pp. 368-373
    • Reuland, M.S.1    Reuland, A.J.2    Nishi, Y.3    Auffarth, G.U.4
  • 26
    • 33845495864 scopus 로고    scopus 로고
    • Comparison of Different Techniques of Anterior Chamber Depth and Keratometric Measurements
    • DOI 10.1016/j.ajo.2006.08.031, PII S0002939406010154
    • Elbaz U, Barkana Y, Gerber Y, Avni I, Zadok D. Comparison of different techniques of anterior chamber depth and keratometric measurements. Am J Ophthalmol. 2007;143(1):48-53. (Pubitemid 44917822)
    • (2007) American Journal of Ophthalmology , vol.143 , Issue.1 , pp. 48-53
    • Elbaz, U.1    Barkana, Y.2    Gerber, Y.3    Avni, I.4    Zadok, D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.