메뉴 건너뛰기




Volumn 15, Issue 1, 2013, Pages 41-47

Robotic assistance and general anaesthesia improve catheter stability and increase signal attenuation during atrial fibrillation ablation

Author keywords

Atrial fibrillation; Catheter ablation; Electrogram; Robotic

Indexed keywords

ADULT; AMPLITUDE MODULATION; ANATOMICAL VARIATION; ARTICLE; CATHETER ABLATION; CLINICAL ARTICLE; CONSCIOUS SEDATION; CONTROLLED STUDY; ELECTROGRAPHY; GENERAL ANESTHESIA; HEART ATRIUM FIBRILLATION; HUMAN; MANUAL PULMONARY VEIN ABLATION; OUTCOME ASSESSMENT; PRIORITY JOURNAL; PULMONARY VEIN ISOLATION; RADIOFREQUENCY ABLATION; RANDOMIZED CONTROLLED TRIAL; ROBOTIC PULMONARY VEIN ABLATION; SIGNAL TRANSDUCTION; TREATMENT DURATION;

EID: 84871189550     PISSN: 10995129     EISSN: 15322092     Source Type: Journal    
DOI: 10.1093/europace/eus244     Document Type: Article
Times cited : (26)

References (25)
  • 3
    • 84857712103 scopus 로고    scopus 로고
    • Histopathologic characterization of chronic radiofrequency ablation lesions for pulmonary vein isolation
    • Kowalski M, Grimes MM, Perez FJ, Kenigsberg DN, Koneru J, Kasirajan V et al. Histopathologic characterization of chronic radiofrequency ablation lesions for pulmonary vein isolation. J Am Coll Cardiol 2012;59:930-8
    • (2012) J Am Coll Cardiol , Issue.59 , pp. 930-938
    • Kowalski, M.1    Grimes, M.M.2    Perez, F.J.3    Kenigsberg, D.N.4    Koneru, J.5    Kasirajan, V.6
  • 4
    • 78649349439 scopus 로고    scopus 로고
    • Persistence of pulmonary vein isolation after robotic remote-navigated ablation for atrial fibrillation and its relation to clinical outcome
    • Willems S, Steven D, Servatius H, Hoffmann BA, Drewitz I, Mullerleile K et al. Persistence of pulmonary vein isolation after robotic remote-navigated ablation for atrial fibrillation and its relation to clinical outcome. J Cardiovasc Electrophysiol 2010;21:1079-84
    • (2010) J Cardiovasc Electrophysiol , Issue.21 , pp. 1079-1084
    • Willems, S.1    Steven, D.2    Servatius, H.3    Hoffmann, B.A.4    Drewitz, I.5    Mullerleile, K.6
  • 8
    • 0025293526 scopus 로고
    • Electrode radius predicts lesion radius during radiofrequency energy heating. Validation of a proposed thermodynamic model
    • Haines DE, Watson DD, Verow AF. Electrode radius predicts lesion radius during radiofrequency energy heating. Validation of a proposed thermodynamic model. Circ Res 1990;67:124-9 (Pubitemid 20223733)
    • (1990) Circulation Research , vol.67 , Issue.1 , pp. 124-129
    • Haines, D.E.1    Watson, D.P.2    Verow, A.F.3
  • 9
    • 33644869315 scopus 로고    scopus 로고
    • Comparison of electrode cooling between internal and open irrigation in radiofrequency ablation lesion depth and incidence of thrombus and steam pop
    • DOI 10.1161/CIRCULATIONAHA.105.540062, PII 0000301720060103000005
    • Yokoyama K, Nakagawa H, Wittkampf FH, Pitha JV, Lazzara R, Jackman WM. Comparison of electrode cooling between internal and open irrigation in radiofrequency ablation lesion depth and incidence of thrombus and steam pop. Circulation 2006;113:11-9 (Pubitemid 43958483)
    • (2006) Circulation , vol.113 , Issue.1 , pp. 11-19
    • Yokoyama, K.1    Nakagawa, H.2    Wittkampf, F.H.M.3    Pitha, J.V.4    Lazzara, R.5    Jackman, W.M.6
  • 11
    • 70450216054 scopus 로고    scopus 로고
    • Ablation of atrial fibrillation utilizing robotic catheter navigation in comparison to manual navigation and ablation: Single-center experience
    • Di Biase L, Wang Y, Horton R, Gallinghouse GJ, Mohanty P, Sanchez J et al. Ablation of atrial fibrillation utilizing robotic catheter navigation in comparison to manual navigation and ablation: Single-center experience. J Cardiovasc Electrophysiol 2009;20:1328-35
    • (2009) J Cardiovasc Electrophysiol , vol.20 , pp. 1328-1335
    • Di Biase, L.1    Wang, Y.2    Horton, R.3    Gallinghouse, G.J.4    Mohanty, P.5    Sanchez, J.6
  • 13
    • 70349446735 scopus 로고    scopus 로고
    • Remote robotic navigation and electroanatomical mapping for ablation of atrial fibrillation: Considerations for navigation and impact on procedural outcome
    • Schmidt B, Tilz RR, Neven K, Julian Chun KR, Furnkranz A, Ouyang F. Remote robotic navigation and electroanatomical mapping for ablation of atrial fibrillation: Considerations for navigation and impact on procedural outcome. Circ Arrhythm Electrophysiol 2009;2:120-8
    • (2009) Circ Arrhythm Electrophysiol , vol.2 , pp. 120-128
    • Schmidt, B.1    Tilz, R.R.2    Neven, K.3    Julian Chun, K.R.4    Furnkranz, A.5    Ouyang, F.6
  • 14
    • 70350589325 scopus 로고    scopus 로고
    • Experience with the Hansen robotic system for atrial fibrillation ablation - lessons learned and techniques modified: Hansen in the real world
    • Wazni OM, Barrett C, Martin DO, Shaheen M, Tarakji K, Baranowski B et al. Experience with the Hansen robotic system for atrial fibrillation ablation - lessons learned and techniques modified: Hansen in the real world. J Cardiovasc Electrophysiol 2009;20:1193-6
    • (2009) J Cardiovasc Electrophysiol , vol.20 , pp. 1193-1196
    • Wazni, O.M.1    Barrett, C.2    Martin, D.O.3    Shaheen, M.4    Tarakji, K.5    Baranowski, B.6
  • 15
    • 60849086189 scopus 로고    scopus 로고
    • Early experience with robotic navigation for catheter ablation of paroxysmal atrial fibrillation
    • Kautzner J, Peichl P, Cihak R, Wichterle D, Mlcochova H. Early experience with robotic navigation for catheter ablation of paroxysmal atrial fibrillation. Pacing Clin Electrophysiol 2009;32(Suppl 1):S163-6
    • (2009) Pacing Clin Electrophysiol , vol.32 , Issue.SUPPL. 1
    • Kautzner, J.1    Peichl, P.2    Cihak, R.3    Wichterle, D.4    Mlcochova, H.5
  • 17
    • 33846994677 scopus 로고    scopus 로고
    • Characterization of the electroanatomical substrate in human atrial fibrillation: The relationship between changes in atrial volume, refractoriness, wavefront propagation velocities, and AF burden
    • Kojodjojo P, Peters NS, Davies DW, Kanagaratnam P. Characterization of the electroanatomical substrate in human atrial fibrillation: The relationship between changes in atrial volume, refractoriness, wavefront propagation velocities, and AF burden. J Cardiovasc Electrophysiol 2007;18:269-75
    • (2007) J Cardiovasc Electrophysiol , vol.18 , pp. 269-275
    • Kojodjojo, P.1    Peters, N.S.2    Davies, D.W.3    Kanagaratnam, P.4
  • 18
    • 0022606755 scopus 로고
    • Relating extracellular potentials and their derivatives to anisotropic propagation at a microscopic level in human cardiac muscle: Evidence for electrical uncoupling of side-to-side fiber connections with increasing age
    • Spach MS, Dolber PC. Relating extracellular potentials and their derivatives to anisotropic propagation at a microscopic level in human cardiac muscle. Evidence for electrical uncoupling of side-to-side fiber connections with increasing age. Circ Res 1986;58:356-71 (Pubitemid 16120759)
    • (1986) Circulation Research , vol.58 , Issue.3 , pp. 356-371
    • Spach, M.S.1    Dolber, P.C.2
  • 19
    • 40849136307 scopus 로고    scopus 로고
    • Novel ablative approach for atrial fibrillation to decrease risk of esophageal injury
    • Bunch TJ, Day JD. Novel ablative approach for atrial fibrillation to decrease risk of esophageal injury. Heart Rhythm 2008;5:624-7
    • (2008) Heart Rhythm , vol.5 , pp. 624-627
    • Bunch, T.J.1    Day, J.D.2
  • 21
    • 33644604591 scopus 로고    scopus 로고
    • Circumferential pulmonary-vein ablation for chronic atrial fibrillation
    • Oral H, Pappone C, Chugh A, Good E, Bogun F, Pelosi F Jr et al. Circumferential pulmonary-vein ablation for chronic atrial fibrillation. N Engl J Med 2006; 354:934-41
    • (2006) N Engl J Med , vol.354 , pp. 934-941
    • Oral, H.1    Pappone, C.2    Chugh, A.3    Good, E.4    Bogun, F.5    Pelosi Jr., F.6
  • 22
    • 79952184710 scopus 로고    scopus 로고
    • General anesthesia reduces the prevalence of pulmonary vein reconnection during repeat ablation when compared with conscious sedation: Results from a randomized study
    • Di Biase L, Conti S, Mohanty P, Bai R, Sanchez J, Walton D et al. General anesthesia reduces the prevalence of pulmonary vein reconnection during repeat ablation when compared with conscious sedation: Results from a randomized study. Heart Rhythm 2011;8:368-72
    • (2011) Heart Rhythm , Issue.8 , pp. 368-372
    • Di Biase, L.1    Conti, S.2    Mohanty, P.3    Bai, R.4    Sanchez, J.5    Walton, D.6
  • 25
    • 63049135802 scopus 로고    scopus 로고
    • Relationship between catheter forces, lesion characteristics, 'popping', and char formation: Experience with robotic navigation system
    • Di Biase L, Natale A, Barrett C, Tan C, Elayi CS, Ching CK et al. Relationship between catheter forces, lesion characteristics, 'popping', and char formation: Experience with robotic navigation system. J Cardiovasc Electrophysiol 2009; 20:436-40
    • (2009) J Cardiovasc Electrophysiol , vol.20 , pp. 436-440
    • Di Biase, L.1    Natale, A.2    Barrett, C.3    Tan, C.4    Elayi, C.S.5    Ching, C.K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.