메뉴 건너뛰기




Volumn 10, Issue 11, 2010, Pages 10448-10466

An online universal diagnosis procedure using two external flux sensors applied to the AC electrical rotating machines

Author keywords

AC motors; Fault diagnosis; Magnetic field sensors; Maintenance

Indexed keywords

CLASSICAL METHODS; DIAGNOSIS PROCEDURE; ELECTROMAGNETIC DEVICES; EXTERNAL MAGNETIC FIELD; FLUX SENSORS; MAGNETIC FIELD SENSORS; ROTATING MACHINE; SHORT-CIRCUIT FAULT;

EID: 84871088092     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s101110448     Document Type: Article
Times cited : (29)

References (19)
  • 2
    • 57849121743 scopus 로고    scopus 로고
    • Bearing fault detection via stator current noise cancellation and statistical control
    • Zhou, W.; Habetler, T.G.; Harley, R.G. Bearing fault detection via stator current noise cancellation and statistical control. IEEE Trans. Ind. Electron. 2008, 55, 4260-4269.
    • (2008) IEEE Trans. Ind. Electron. , vol.55 , pp. 4260-4269
    • Zhou, W.1    Habetler, T.G.2    Harley, R.G.3
  • 3
    • 0034297784 scopus 로고    scopus 로고
    • The detection of inter turn short-circuits in the stator windings of operating motors
    • Joksimovic, M.G.; Penman, J. The detection of inter turn short-circuits in the stator windings of operating motors. IEEE Trans. Ind. Electron. 2000, 47, 1078-1084.
    • (2000) IEEE Trans. Ind. Electron. , vol.47 , pp. 1078-1084
    • Joksimovic, M.G.1    Penman, J.2
  • 4
    • 57749200463 scopus 로고    scopus 로고
    • Analysis and Application of particular current signatures (symptoms) for cage monitoring in nonsinusoidally fed motors with high rejection to drive load, inertia, and frequency variations
    • Bruzzese, C. Analysis and Application of particular current signatures (symptoms) for cage monitoring in nonsinusoidally fed motors with high rejection to drive load, inertia, and frequency variations. IEEE Trans. Ind. Electron. 2008, 55, 4137-4155.
    • (2008) IEEE Trans. Ind. Electron. , vol.55 , pp. 4137-4155
    • Bruzzese, C.1
  • 6
    • 57749204314 scopus 로고    scopus 로고
    • Eccentricity fault diagnosis of a dual-stator winding induction machine drive considering the slotting effects
    • Andriamalala, R.N.; Razik, H.; Baghli, L.; Sargos, F.M. Eccentricity fault diagnosis of a dual-stator winding induction machine drive considering the slotting effects. IEEE Trans. Ind. Electron. 2008, 55, 4238-4251.
    • (2008) IEEE Trans. Ind. Electron. , vol.55 , pp. 4238-4251
    • Andriamalala, R.N.1    Razik, H.2    Baghli, L.3    Sargos, F.M.4
  • 7
    • 41349105525 scopus 로고    scopus 로고
    • Induction machine broken bar and stator short-circuit fault diagnostics based on three-phase stator current envelopes
    • da Silva, A.M.; Povinelli, R.J.; Demerdash N.A.O. Induction machine broken bar and stator short-circuit fault diagnostics based on three-phase stator current envelopes. IEEE Trans. Ind. Electron. 2008, 55, 1310-1318.
    • (2008) IEEE Trans. Ind. Electron. , vol.55 , pp. 1310-1318
    • da Silva, A.M.1    Povinelli, R.J.2    Demerdash, N.A.O.3
  • 8
    • 33746338247 scopus 로고    scopus 로고
    • A method to detect broken bars in induction machine using pattern recognition techniques
    • Ondel, O.; Boutleux, E.; Clerc, G. A method to detect broken bars in induction machine using pattern recognition techniques. IEEE Trans. Ind. Appl. 2006, 42, 916-923.
    • (2006) IEEE Trans. Ind. Appl. , vol.42 , pp. 916-923
    • Ondel, O.1    Boutleux, E.2    Clerc, G.3
  • 10
    • 0028742406 scopus 로고
    • Detection and location of inter-turn short circuit in the stator windings of operating motors
    • Penman, J.; Sedding, H.G.; Lloyd, B.A.; Fink, W.T. Detection and location of inter-turn short circuit in the stator windings of operating motors. IEEE Trans. Energy Convers. 1994, 9, 652-658.
    • (1994) IEEE Trans. Energy Convers. , vol.9 , pp. 652-658
    • Penman, J.1    Sedding, H.G.2    Lloyd, B.A.3    Fink, W.T.4
  • 11
    • 0242274222 scopus 로고    scopus 로고
    • A frequency-domain of stator winding faults in induction machines using an external flux sensor
    • Henao, H.; Demian, C.; Capolino, G.A. A frequency-domain of stator winding faults in induction machines using an external flux sensor. IEEE Trans. Ind. Appl. 2003, 39, 1272-1279.
    • (2003) IEEE Trans. Ind. Appl. , vol.39 , pp. 1272-1279
    • Henao, H.1    Demian, C.2    Capolino, G.A.3
  • 12
    • 29444455648 scopus 로고    scopus 로고
    • Induction machine fault diagnosis using an external radial flux Sensor
    • Romary, R.; Corton, R.; Thailly, D.; Brudny, J.F. Induction machine fault diagnosis using an external radial flux Sensor. Eur. Phys. J-Appl. Phys. 2005, 32, 125-132.
    • (2005) Eur. Phys. J-Appl. Phys. , vol.32 , pp. 125-132
    • Romary, R.1    Corton, R.2    Thailly, D.3    Brudny, J.F.4
  • 14
    • 77954245767 scopus 로고    scopus 로고
    • Effects of eccentricity on external magnetic field of induction machine
    • Presented at, Valletta, Malta, April
    • Vitek, O.; Janda, M.; Hajek, V. Effects of eccentricity on external magnetic field of induction machine. Presented at 15th IEEE Mediterranean Electrotechnical Conference MELECON 2010, Valletta, Malta, April 2010; pp. 939-943.
    • (2010) 15th IEEE Mediterranean Electrotechnical Conference MELECON 2010 , pp. 939-943
    • Vitek, O.1    Janda, M.2    Hajek, V.3
  • 15
    • 0026915223 scopus 로고
    • Air gap permeance in doubly-slotted asynchronous machines
    • Harry Hesse, M. Air gap permeance in doubly-slotted asynchronous machines. IEEE Trans. Energy Conv. 1992, 7, 491-499.
    • (1992) IEEE Trans. Energy Conv. , vol.7 , pp. 491-499
    • Harry Hesse, M.1
  • 16
    • 0031139914 scopus 로고    scopus 로고
    • Modelling of induction machine slotting. Resonance phenomenom
    • Brudny, J.F. Modelling of induction machine slotting. Resonance phenomenom. Eur. Phys. J-Appl. Phys. JP III. 1997; pp. 1009-1023.
    • (1997) Eur. Phys. J-Appl. Phys. JP III. , pp. 1009-1023
    • Brudny, J.F.1
  • 17
    • 68349141264 scopus 로고    scopus 로고
    • Analytical computation of an AC machine external magnetic field
    • Romary, R.; Roger, D.; Brudny, J.F. Analytical computation of an AC machine external magnetic field. Eur. Phys. J-Appl. Phys. 2009, 47, 31102-p1-31102-p6.
    • (2009) Eur. Phys. J-Appl. Phys. , vol.47
    • Romary, R.1    Roger, D.2    Brudny, J.F.3
  • 18
    • 72749117306 scopus 로고    scopus 로고
    • Diagnosis of induction machines: Definition of health machine electromagnetic signature
    • In, Springer: New York, NY, USA
    • Thailly, D.; Romary, R.; Brudny, J.F. Diagnosis of induction machines: Definition of health machine electromagnetic signature. In Recent Developments of Electrical Drives; Springer: New York, NY, USA, 2006; pp. 237-246.
    • (2006) Recent Developments of Electrical Drives , pp. 237-246
    • Thailly, D.1    Romary, R.2    Brudny, J.F.3
  • 19
    • 84952799015 scopus 로고    scopus 로고
    • Synchronous machine diagnosis using an external magnetic flux sensor
    • paper: CD ROM, N° 462, Presented at the, ICEM Chania, Crête, September, abstract
    • Thailly, D.; Romary, R.; Lecointe, J. Ph.; Brudny, J.F.; Suau, P. Synchronous machine diagnosis using an external magnetic flux sensor. Presented at the 17th International Conference on Electrical Machines, ICEM 2006; Chania, Crête, September 2006, abstract p. 59, paper: CD ROM, N° 462.
    • (2006) 17th International Conference on Electrical Machines , pp. 59
    • Thailly, D.1    Romary, R.2    Lecointe, J.P.3    Brudny, J.F.4    Suau, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.