메뉴 건너뛰기




Volumn 40, Issue 3, 2012, Pages 168-174

Semiautomatic region-of-interest validation at the femur in 18F-fluoride PET/CT

Author keywords

18 F PET CT; Bone; Femur; Region of interest; Validation

Indexed keywords

18F FLUORIDE; RADIOPHARMACEUTICAL AGENT; UNCLASSIFIED DRUG;

EID: 84871022578     PISSN: 00914916     EISSN: None     Source Type: Journal    
DOI: 10.2967/jnmt.111.100107     Document Type: Article
Times cited : (8)

References (30)
  • 1
    • 77953507633 scopus 로고    scopus 로고
    • Correlates of trabecular and cortical volumetric bone mineral density of the radius and tibia in older men: the Osteoporotic Fractures in Men Study
    • Barbour KE, Zmuda J, Strotmeyer E, et al. Correlates of trabecular and cortical volumetric bone mineral density of the radius and tibia in older men: the Osteoporotic Fractures in Men Study. J Bone Miner Res. 2010;25:1017-1028.
    • (2010) J Bone Miner Res , vol.25 , pp. 1017-1028
    • Barbour, K.E.1    Zmuda, J.2    Strotmeyer, E.3
  • 2
    • 77956852103 scopus 로고    scopus 로고
    • Correlates of trabecular and cortical volumetric bone mineral density (vBMD) at the femoral neck and lumbar spine: the osteoporotic fractures in men study (MrOS)
    • Cauley J, Blackwell T, Zmuda J, et al. Correlates of trabecular and cortical volumetric bone mineral density (vBMD) at the femoral neck and lumbar spine: the osteoporotic fractures in men study (MrOS). J Bone Miner Res. 2010;25: 1958-1971.
    • (2010) J Bone Miner Res , vol.25 , pp. 1958-1971
    • Cauley, J.1    Blackwell, T.2    Zmuda, J.3
  • 3
    • 0034960491 scopus 로고    scopus 로고
    • 18F]fluoride ion PET: correlation with bone histomorphometry
    • 18F]fluoride ion PET: correlation with bone histomorphometry. J Nucl Med. 2001;42:1091-1100.
    • (2001) J Nucl Med , vol.42 , pp. 1091-1100
    • Piert, M.1    Zittel, T.T.2    Becker, G.A.3
  • 4
    • 0027494688 scopus 로고
    • 18F]fluoride ion in renal osteodystrophy: correlation with bone histomorphometry
    • 18F]fluoride ion in renal osteodystrophy: correlation with bone histomorphometry. J Clin Endocrinol Metab. 1993;77: 949-955.
    • (1993) J Clin Endocrinol Metab , vol.77 , pp. 949-955
    • Messa, C.1    Goodman, W.G.2    Hoh, C.K.3
  • 6
    • 0032749549 scopus 로고    scopus 로고
    • Non-invasive assessment of skeletal kinetics using fluorine-18 fluoride positron emission tomography: evaluation of image and population-derived arterial input functions
    • Cook GJ, Lodge MA, Marsden PK, Dynes A, Fogelman I. Non-invasive assessment of skeletal kinetics using fluorine-18 fluoride positron emission tomography: evaluation of image and population-derived arterial input functions. Eur J Nucl Med. 1999;26:1424-1429.
    • (1999) Eur J Nucl Med , vol.26 , pp. 1424-1429
    • Cook, G.J.1    Lodge, M.A.2    Marsden, P.K.3    Dynes, A.4    Fogelman, I.5
  • 7
    • 0038782206 scopus 로고    scopus 로고
    • A new accurate and precise 3-D segmentation method for skeletal structures in volumetric CT data
    • Kang Y, Engelke K, Kalender W. A new accurate and precise 3-D segmentation method for skeletal structures in volumetric CT data. IEEE Trans Med Imaging. 2003;22:586-598.
    • (2003) IEEE Trans Med Imaging , vol.22 , pp. 586-598
    • Kang, Y.1    Engelke, K.2    Kalender, W.3
  • 9
    • 1442288644 scopus 로고    scopus 로고
    • Automated segmentation of acetabulum and femoral head from 3-D CT images
    • Zoroofi RA, Sato Y, Nishii T, et al. Automated segmentation of acetabulum and femoral head from 3-D CT images. IEEE Trans Inf Technol Biomed. 2003;7:329-343.
    • (2003) IEEE Trans Inf Technol Biomed , vol.7 , pp. 329-343
    • Zoroofi, R.A.1    Sato, Y.2    Nishii, T.3
  • 10
    • 0029151305 scopus 로고
    • Proximal femur bone mineral levels of US adults
    • Looker AC, Wahner HW, Dunn WL, et al. Proximal femur bone mineral levels of US adults. Osteoporos Int. 1995;5:389-409.
    • (1995) Osteoporos Int , vol.5 , pp. 389-409
    • Looker, A.C.1    Wahner, H.W.2    Dunn, W.L.3
  • 11
    • 77957877373 scopus 로고    scopus 로고
    • Radiation exposure in x-ray-based imaging techniques used in osteoporosis
    • Damilakis J, Adams J, Guglielmi G, Link T. Radiation exposure in x-ray-based imaging techniques used in osteoporosis. Eur Radiol. 2010;20:2707-2714.
    • (2010) Eur Radiol , vol.20 , pp. 2707-2714
    • Damilakis, J.1    Adams, J.2    Guglielmi, G.3    Link, T.4
  • 12
    • 74249110212 scopus 로고    scopus 로고
    • Analysis of hip geometry by clinical CT for the assessment of hip fracture risk in elderly Japanese women
    • Ito M, Wakao N, Hida T, et al. Analysis of hip geometry by clinical CT for the assessment of hip fracture risk in elderly Japanese women. Bone. 2010;46:453-457.
    • (2010) Bone , vol.46 , pp. 453-457
    • Ito, M.1    Wakao, N.2    Hida, T.3
  • 13
    • 0036139134 scopus 로고    scopus 로고
    • Measurement of bone mineral density at the spine and proximal femur by volumetric quantitative computed tomography and dual-energy x-ray absorptiometry in elderly women with and without vertebral fractures
    • Lang TF, Guglielmi G, van Kuijk C, De Serio A, Cammisa M, Genant HK. Measurement of bone mineral density at the spine and proximal femur by volumetric quantitative computed tomography and dual-energy x-ray absorptiometry in elderly women with and without vertebral fractures. Bone. 2002;30:247-250.
    • (2002) Bone , vol.30 , pp. 247-250
    • Lang, T.F.1    Guglielmi, G.2    van Kuijk, C.3    De Serio, A.4    Cammisa, M.5    Genant, H.K.6
  • 14
    • 14144251613 scopus 로고    scopus 로고
    • In vivo validation of a novel semiautomated method for border detection in intravascular ultrasound images
    • Bourantas CV, Plissiti ME, Fotiadis DI, et al. In vivo validation of a novel semiautomated method for border detection in intravascular ultrasound images. Br J Radiol. 2005;78:122-129.
    • (2005) Br J Radiol , vol.78 , pp. 122-129
    • Bourantas, C.V.1    Plissiti, M.E.2    Fotiadis, D.I.3
  • 15
    • 0031240184 scopus 로고    scopus 로고
    • A methodology for evaluation of boundary detection algorithms on medical images
    • Chalana V, Kim Y. A methodology for evaluation of boundary detection algorithms on medical images. IEEE Trans Med Imaging. 1997;16:642-652.
    • (1997) IEEE Trans Med Imaging , vol.16 , pp. 642-652
    • Chalana, V.1    Kim, Y.2
  • 16
    • 0343570527 scopus 로고    scopus 로고
    • An update on the diagnosis and assessment of osteoporosis with densitometry
    • Kanis JA, Gluer CC. An update on the diagnosis and assessment of osteoporosis with densitometry. Osteoporos Int. 2000;11:192-202.
    • (2000) Osteoporos Int , vol.11 , pp. 192-202
    • Kanis, J.A.1    Gluer, C.C.2
  • 17
    • 77953402854 scopus 로고    scopus 로고
    • Changing structure of the femoral neck across the adult female lifespan
    • Poole KES, Mayhew PM, Rose CM, et al. Changing structure of the femoral neck across the adult female lifespan. J Bone Miner Res. 2010;25:482-491.
    • (2010) J Bone Miner Res , vol.25 , pp. 482-491
    • Poole, K.E.S.1    Mayhew, P.M.2    Rose, C.M.3
  • 18
    • 84871028349 scopus 로고    scopus 로고
    • Construction and Validation of an Automatic Method for Region of Interest Selection in DMSA Renal Scans
    • Department of Medical Physics and Clinical Engineering Sheffield University. Sheffield, U.K
    • Colgan N. Construction and Validation of an Automatic Method for Region of Interest Selection in DMSA Renal Scans. Sheffield, U.K.: Department of Medical Physics and Clinical Engineering, Sheffield University; 2004.
    • (2004)
    • Colgan, N.1
  • 19
    • 0000250265 scopus 로고
    • Measures of the amount of ecologic association between species
    • Dice LR. Measures of the amount of ecologic association between species. Ecology. 1945;26:297-302.
    • (1945) Ecology , vol.26 , pp. 297-302
    • Dice, L.R.1
  • 20
    • 0026045948 scopus 로고
    • Measurement and reliability: statistical thinking considerations
    • Bartko JJ. Measurement and reliability: statistical thinking considerations. Schizophr Bull. 1991;17:483-489.
    • (1991) Schizophr Bull , vol.17 , pp. 483-489
    • Bartko, J.J.1
  • 22
    • 35148872689 scopus 로고    scopus 로고
    • Automatic segmentation and reconstruction of the cortex from neonatal MRI
    • Xue H, Srinivasan L, Jiang S, et al. Automatic segmentation and reconstruction of the cortex from neonatal MRI. Neuroimage. 2007;38:461-477.
    • (2007) Neuroimage , vol.38 , pp. 461-477
    • Xue, H.1    Srinivasan, L.2    Jiang, S.3
  • 23
    • 78650803425 scopus 로고    scopus 로고
    • Hippocampal volumetry for lateralization of temporal lobe epilepsy: automated versus manual methods
    • Akhondi-Asl A, Jafari-Khouzani K, Elisevich K, Soltanian-Zadeh H. Hippocampal volumetry for lateralization of temporal lobe epilepsy: automated versus manual methods. Neuroimage. 2010;(suppl 1):S218-S226.
    • (2010) Neuroimage , Issue.SUPPL. 1
    • Akhondi-Asl, A.1    Jafari-Khouzani, K.2    Elisevich, K.3    Soltanian-Zadeh, H.4
  • 24
    • 74949102081 scopus 로고    scopus 로고
    • Hippocampal volume assessment in temporal lobe epilepsy: how good is automated segmentation?
    • Pardoe HR, Pell GS, Abbott DF, Jackson GD. Hippocampal volume assessment in temporal lobe epilepsy: how good is automated segmentation? Epilepsia. 2009; 50:2586-2592.
    • (2009) Epilepsia , vol.50 , pp. 2586-2592
    • Pardoe, H.R.1    Pell, G.S.2    Abbott, D.F.3    Jackson, G.D.4
  • 25
    • 76749100200 scopus 로고    scopus 로고
    • Manual validation of FreeSurfer's automated hippocampal segmentation in normal aging, mild cognitive impairment, and Alzheimer Disease subjects
    • Sánchez-Benavides G, Gosṕmez-Ansosṕn B, SainzA, Vives Y, Delfino M, Peña-Casanova J. Manual validation of FreeSurfer's automated hippocampal segmentation in normal aging, mild cognitive impairment, and Alzheimer Disease subjects. Psychiatry Res. 2010;181:219-225.
    • (2010) Psychiatry Res , vol.181 , pp. 219-225
    • Sasṕnchez-Benavides, G.1    Gosṕmez-Ansosṕn, B.2    Sainz, A.3    Vives, Y.4    Delfino, M.5    Peña-Casanova, J.6
  • 26
    • 0034076558 scopus 로고    scopus 로고
    • Three-dimensional automatic quantitative analysis of intravascular ultrasound images
    • Kovalski G, Beyar R, Shofti R, Azhari H. Three-dimensional automatic quantitative analysis of intravascular ultrasound images. Ultrasound Med Biol. 2000; 26:527-537.
    • (2000) Ultrasound Med Biol , vol.26 , pp. 527-537
    • Kovalski, G.1    Beyar, R.2    Shofti, R.3    Azhari, H.4
  • 30
    • 36348941078 scopus 로고    scopus 로고
    • Use of the CT component of PET-CT to improve PET-MR registration: demonstration in softtissue sarcoma
    • Somer EJ, Benatar NA, O'Doherty MJ, Smith MA, Marsden PK. Use of the CT component of PET-CT to improve PET-MR registration: demonstration in softtissue sarcoma. Phys Med Biol. 2007;52:6991-7006.
    • (2007) Phys Med Biol , vol.52 , pp. 6991-7006
    • Somer, E.J.1    Benatar, N.A.2    O'Doherty, M.J.3    Smith, M.A.4    Marsden, P.K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.