메뉴 건너뛰기




Volumn 68, Issue 1, 2013, Pages 21-26

Comparison of the single-use Ambu® aScope™ 2 vs the conventional fibrescope for tracheal intubation in patients with cervical spine immobilisation by a semirigid collar

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CAMERA; CERVICAL COLLAR; CERVICAL SPINE; CLINICAL ARTICLE; DEVICES; EMERGENCY TREATMENT; ENDOTRACHEAL INTUBATION; FEMALE; FIBEROSCOPE; HUMAN; JAW THRUST MANEUVER; MALE; RESPIRATION CONTROL; SECRETION (PROCESS); VIDEOSCOPE;

EID: 84870974695     PISSN: 00032409     EISSN: 13652044     Source Type: Journal    
DOI: 10.1111/anae.12044     Document Type: Article
Times cited : (28)

References (18)
  • 2
    • 64149108119 scopus 로고    scopus 로고
    • Laryngoscopy: Time to change our view
    • Frerk CM, Lee G,. Laryngoscopy: time to change our view. Anaesthesia 2009; 64: 351-4.
    • (2009) Anaesthesia , vol.64 , pp. 351-354
    • Frerk, C.M.1    Lee, G.2
  • 3
    • 0037406762 scopus 로고    scopus 로고
    • Practice guidelines for management of the difficult airway: An updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway
    • American Society of Anesthesiologists Task Force on Management of the Difficult Airway.
    • American Society of Anesthesiologists Task Force on Management of the Difficult Airway. Practice guidelines for management of the difficult airway: an updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway. Anesthesiology 2003; 98: 1269-77.
    • (2003) Anesthesiology , vol.98 , pp. 1269-1277
  • 4
    • 3242884152 scopus 로고    scopus 로고
    • Difficult Airway Society guidelines for management of the unanticipated difficult intubation
    • DOI 10.1111/j.1365-2044.2004.03831.x
    • Henderson JJ, Popat MT, Latto IP, Pearce AC,. Difficult Airway Society guidelines for management of the unanticipated difficult intubation. Anaesthesia 2004; 59: 675-94. (Pubitemid 38997010)
    • (2004) Anaesthesia , vol.59 , Issue.7 , pp. 675-694
    • Henderson, J.J.1    Popat, M.T.2    Latto, I.P.3    Pearce, A.C.4
  • 6
    • 82755186001 scopus 로고    scopus 로고
    • Cost-effectiveness analysis of flexible optical scopes for tracheal intubation: A descriptive comparative study of re-usable and single-use scopes
    • Gupta D, Wang H,. Cost-effectiveness analysis of flexible optical scopes for tracheal intubation: a descriptive comparative study of re-usable and single-use scopes. Journal of Clinical Anesthesia 2011; 23: 632-5.
    • (2011) Journal of Clinical Anesthesia , vol.23 , pp. 632-635
    • Gupta, D.1    Wang, H.2
  • 7
    • 84871000971 scopus 로고    scopus 로고
    • Medical Devices Agency Decontamination of Endoscopes - DB 2002(05)
    • (accessed 09/09/2012)
    • Medical Devices Agency Decontamination of Endoscopes-DB 2002(05). Medical Devices Agency. http://www.mhra.gov.uk/publications/Safetyguidance/ DeviceBulletins/CON007329(accessed 09/09/2012).
    • Medical Devices Agency
  • 8
    • 49249093572 scopus 로고    scopus 로고
    • Association of Anaesthetists of Great Britain and Ireland Infection control in anaesthesia
    • Association of Anaesthetists of Great Britain and Ireland Infection control in anaesthesia. Anaesthesia 2008; 63: 1027-36.
    • (2008) Anaesthesia , vol.63 , pp. 1027-1036
  • 9
    • 77954491140 scopus 로고    scopus 로고
    • Evaluation of the novel, single-use, flexible aScope for tracheal intubation in the simulated difficult airway and first clinical experiences
    • Piepho T, Werner C, Noppens RR,. Evaluation of the novel, single-use, flexible aScope for tracheal intubation in the simulated difficult airway and first clinical experiences. Anaesthesia 2010; 65: 820-5.
    • (2010) Anaesthesia , vol.65 , pp. 820-825
    • Piepho, T.1    Werner, C.2    Noppens, R.R.3
  • 10
    • 79952748272 scopus 로고    scopus 로고
    • Evaluation of a single-use intubating videoscope (Ambu aScope) in three airway training manikins for oral intubation, nasal intubation and intubation via three supraglottic airway devices
    • Scutt S, Clark N, Cook TM, et al. Evaluation of a single-use intubating videoscope (Ambu aScope) in three airway training manikins for oral intubation, nasal intubation and intubation via three supraglottic airway devices. Anaesthesia 2011; 66: 293-9.
    • (2011) Anaesthesia , vol.66 , pp. 293-299
    • Scutt, S.1    Clark, N.2    Cook, T.M.3
  • 11
    • 79960358599 scopus 로고    scopus 로고
    • Comparison of the manoeuvrability and ease of use of the Ambu aScope and Olympus re-usable fibrescope in a manikin
    • Vijayakumar M, Clarke A, Wilkes AR, Goodwin N, Hodzovic I,. Comparison of the manoeuvrability and ease of use of the Ambu aScope and Olympus re-usable fibrescope in a manikin. Anaesthesia 2011; 66: 689-93.
    • (2011) Anaesthesia , vol.66 , pp. 689-693
    • Vijayakumar, M.1    Clarke, A.2    Wilkes, A.R.3    Goodwin, N.4    Hodzovic, I.5
  • 12
    • 77956525275 scopus 로고    scopus 로고
    • Use of the Ambu((R)) aScope in 10 patients with predicted difficult intubation
    • Pujol E, Lopez AM, Valero R,. Use of the Ambu((R)) aScope in 10 patients with predicted difficult intubation. Anaesthesia 2010; 65: 1037-40.
    • (2010) Anaesthesia , vol.65 , pp. 1037-1040
    • Pujol, E.1    Lopez, A.M.2    Valero, R.3
  • 13
    • 24944549606 scopus 로고    scopus 로고
    • Reduction in mouth opening with semi-rigid cervical collars
    • DOI 10.1093/bja/aei190
    • Goutcher CM, Lochhead V,. Reduction in mouth opening with semi-rigid cervical collars. British Journal of Anaesthesia 2005; 95: 344-8. (Pubitemid 41487345)
    • (2005) British Journal of Anaesthesia , vol.95 , Issue.3 , pp. 344-348
    • Goutcher, C.M.1    Lochhead, V.2
  • 14
    • 70449633236 scopus 로고    scopus 로고
    • Evaluation of the GlideScope for tracheal intubation in patients with cervical spine immobilisation by a semi-rigid collar
    • Bathory I, Frascarolo P, Kern C, Schoettker P,. Evaluation of the GlideScope for tracheal intubation in patients with cervical spine immobilisation by a semi-rigid collar. Anaesthesia 2009; 64: 1337-41.
    • (2009) Anaesthesia , vol.64 , pp. 1337-1341
    • Bathory, I.1    Frascarolo, P.2    Kern, C.3    Schoettker, P.4
  • 16
    • 80053329777 scopus 로고    scopus 로고
    • Use of a modified Ovassapian airway to increase mouth opening for fiberoptic orotracheal intubation in a patient with severe trismus
    • Truong A, Truong DT,. Use of a modified Ovassapian airway to increase mouth opening for fiberoptic orotracheal intubation in a patient with severe trismus. Anesthesia and Analgesia 2011; 113: 958-9.
    • (2011) Anesthesia and Analgesia , vol.113 , pp. 958-959
    • Truong, A.1    Truong, D.T.2
  • 18
    • 0036173720 scopus 로고    scopus 로고
    • Orotracheal fibreoptic intubation for rapid sequence induction of anaesthesia
    • DOI 10.1046/j.0003-2409.2001.02400.x
    • Pandit JJ, Dravid RM, Iyer R, Popat MT,. Orotracheal fibreoptic intubation for rapid sequence induction of anaesthesia. Anaesthesia 2002; 57: 123-7. (Pubitemid 34149948)
    • (2002) Anaesthesia , vol.57 , Issue.2 , pp. 123-127
    • Pandit, J.J.1    Dravid, R.M.2    Iyer, R.3    Popat, M.T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.