메뉴 건너뛰기




Volumn 23, Issue 8, 2011, Pages 632-635

Cost-effectiveness analysis of flexible optical scopes for tracheal intubation: A descriptive comparative study of reusable and single-use scopes

Author keywords

Intubation cost analysis; Intubation scope; Reusable scope; Single use scope

Indexed keywords

ARTICLE; CONTROLLED STUDY; COST EFFECTIVENESS ANALYSIS; ENDOTRACHEAL INTUBATION; FIBEROSCOPE; HOSPITAL COST; HUMAN; INTERMETHOD COMPARISON; LARYNGOSCOPE; OPEN STUDY; PRIORITY JOURNAL; RETROSPECTIVE STUDY; REUSABLE FIBEROPTIC SCOPE; SINGLE USE INTUBATION SCOPE;

EID: 82755186001     PISSN: 09528180     EISSN: 18734529     Source Type: Journal    
DOI: 10.1016/j.jclinane.2011.04.007     Document Type: Article
Times cited : (28)

References (15)
  • 1
    • 0037406762 scopus 로고    scopus 로고
    • Practice guidelines for management of the difficult airway: An updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway
    • American Society Of Anesthesiologists Task Force On Management Of The Difficult Airway
    • American Society of Anesthesiologists Task Force on Management of the Difficult Airway Practice guidelines for management of the difficult airway: an updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway Anesthesiology 98 2003 1269 1277
    • (2003) Anesthesiology , vol.98 , pp. 1269-1277
  • 2
    • 84859921802 scopus 로고    scopus 로고
    • Available at. Accessed August 20, 2010
    • Available at http://ambu.net.dynamicweb.dk/aScopeUS/Product-Details.aspx. Accessed August 20, 2010.
  • 3
    • 84859908737 scopus 로고    scopus 로고
    • Available at. Accessed August 20, 2010
    • Available at http://ambu.net.dynamicweb.dk/Files/Billeder/com/ Landingpages/aScope/Ambu-aScope-brochure.pdf. Accessed August 20, 2010.
  • 4
    • 84859925367 scopus 로고    scopus 로고
    • Available at. Accessed August 20, 2010
    • Available at http://ambu.net.dynamicweb.dk/Files/Billeder/com/ Landingpages/aScope/IE-aScope-493200201-0509.pdf. Accessed August 20, 2010.
  • 5
    • 84859911079 scopus 로고    scopus 로고
    • Available at. Accessed August 20, 2010
    • Available at http://ambu.net.dynamicweb.dk/Files/Billeder/com/ Landingpages/aScope/IE-aScope-monitor-493200301-0509.pdf. Accessed August 20, 2010.
  • 6
    • 84859911080 scopus 로고    scopus 로고
    • Available at. Accessed August 20, 2010
    • Available at http://www.bsg.org.uk/images/stories/docs/clinical/ guidelines/endoscopy/decontamination-2008.pdf. Accessed August 20, 2010.
  • 7
    • 84859925368 scopus 로고    scopus 로고
    • Available at. Accessed August 20, 2010
    • Available at http://www.bsg.org.uk/images/stories/docs/clinical/ guidelines/endoscopy/decontamination-vCJD-08.pdf. Accessed August 20, 2010.
  • 8
    • 84859908738 scopus 로고    scopus 로고
    • Available at. Accessed August 20, 2010
    • Available at http://www.entuk.org/members/publications/scopesfullweb2. pdf. Accessed August 20, 2010.
  • 9
    • 64449084063 scopus 로고    scopus 로고
    • Flexible bronchoscope damage and repair costs in a bronchoscopy teaching unit
    • A. Rozman, S. Duh, M. Petrinec-Primozic, and N. Triller Flexible bronchoscope damage and repair costs in a bronchoscopy teaching unit Respiration 77 2009 325 330
    • (2009) Respiration , vol.77 , pp. 325-330
    • Rozman, A.1    Duh, S.2    Petrinec-Primozic, M.3    Triller, N.4
  • 10
    • 23044466730 scopus 로고    scopus 로고
    • High price of bronchoscopy: Cost of maintenance and repair of flexible bronchoscopes
    • DOI 10.1097/01.laboratory.0000172943.72334.ff
    • A.J. Choure, E.D. Manali, G. Krizmanich, T.R. Gildea, and A.C. Mehta High price of bronchoscopy: cost of maintenance and repair of flexible bronchoscopes J Bronchol Intervent Pulmonol 12 2005 147 150 (Pubitemid 41061227)
    • (2005) Journal of Bronchology , vol.12 , Issue.3 , pp. 147-150
    • Choure, A.J.1    Manali, E.D.2    Krizmanich, G.3    Gildea, T.R.4    Mehta, A.C.5
  • 11
    • 19044399445 scopus 로고    scopus 로고
    • Reducing maintenance and repair costs in an interventional pulmonology program
    • DOI 10.1378/chest.127.4.1382
    • W. Lunn, R. Garland, L. Gryniuk, L. Smith, D. Feller-Kopman, and A. Ernst Reducing maintenance and repair costs in an interventional pulmonology program Chest 127 2005 1382 1387 (Pubitemid 46224305)
    • (2005) Chest , vol.127 , Issue.4 , pp. 1382-1387
    • Lunn, W.1    Garland, R.2    Gryniuk, L.3    Smith, L.4    Feller-Kopman, D.5    Ernst, A.6
  • 12
    • 0026729933 scopus 로고
    • Bronchoscope damage and repair costs: Results of a regional postal survey
    • M.B. Kirkpatrick, J.R. Smith, P.J. Hoffman, and R.M. Middleton 3rd Bronchoscope damage and repair costs: results of a regional postal survey Respir Care 37 1992 1256 1259 (Pubitemid 23010955)
    • (1992) Respiratory Care , vol.37 , Issue.11 , pp. 1256-1259
    • Kirkpatrick, M.B.1    Smith, J.R.2    Hoffman, P.J.3    Middleton III, R.M.4
  • 13
    • 43749119189 scopus 로고    scopus 로고
    • Optical and video laryngoscopes for emergency airway management
    • J.C. Sakles, R. Rodgers, and S.M. Keim Optical and video laryngoscopes for emergency airway management Intern Emerg Med 3 2008 139 143
    • (2008) Intern Emerg Med , vol.3 , pp. 139-143
    • Sakles, J.C.1    Rodgers, R.2    Keim, S.M.3
  • 14
    • 77954491140 scopus 로고    scopus 로고
    • Evaluation of the novel, single-use, flexible aScope for tracheal intubation in the simulated difficult airway and first clinical experiences
    • T. Piepho, C. Werner, and R.R. Noppens Evaluation of the novel, single-use, flexible aScope for tracheal intubation in the simulated difficult airway and first clinical experiences Anaesthesia 65 2010 820 825
    • (2010) Anaesthesia , vol.65 , pp. 820-825
    • Piepho, T.1    Werner, C.2    Noppens, R.R.3
  • 15
    • 84859921803 scopus 로고    scopus 로고
    • Available at. Accessed August 20, 2010
    • Available at http://www.visionsciences.com/SWAPPID/96/SubPageID/32585. Accessed August 20, 2010.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.