메뉴 건너뛰기




Volumn 16, Issue 6, 2012, Pages 508-510

The use of the Icare tonometer reduced the need for anesthesia to measure intraocular pressure in children

Author keywords

[No Author keywords available]

Indexed keywords

ANESTHESIA; ARTICLE; CHILD; CLINICAL PRACTICE; GLAUCOMA; HUMAN; INTRAOCULAR PRESSURE; MAJOR CLINICAL STUDY; MEDICAL RECORD REVIEW; PRESCHOOL CHILD; PRIORITY JOURNAL; TONOMETER; TONOMETRY;

EID: 84870900038     PISSN: 10918531     EISSN: 15283933     Source Type: Journal    
DOI: 10.1016/j.jaapos.2012.07.004     Document Type: Article
Times cited : (35)

References (9)
  • 1
    • 79751530990 scopus 로고    scopus 로고
    • Application of the ICare rebound tonometer in healthy infants
    • A. Lundvall, H. Svedberg, and E. Chen Application of the ICare rebound tonometer in healthy infants J Glaucoma 20 2011 7 9
    • (2011) J Glaucoma , vol.20 , pp. 7-9
    • Lundvall, A.1    Svedberg, H.2    Chen, E.3
  • 2
    • 78651425786 scopus 로고    scopus 로고
    • Comparison of ICare rebound tonometer with noncontact tonometer in healthy children
    • M. Kageyama, K. Hirooka, T. Baba, and F. Shiraga Comparison of ICare rebound tonometer with noncontact tonometer in healthy children J Glaucoma 20 2011 63 66
    • (2011) J Glaucoma , vol.20 , pp. 63-66
    • Kageyama, M.1    Hirooka, K.2    Baba, T.3    Shiraga, F.4
  • 3
    • 34247633160 scopus 로고    scopus 로고
    • Reproducibility and tolerability of the ICare rebound tonometer in school children
    • A. Sahin, H. Basmak, L. Niyaz, and N. Yildirim Reproducibility and tolerability of the ICare rebound tonometer in school children J Glaucoma 16 2007 185 188
    • (2007) J Glaucoma , vol.16 , pp. 185-188
    • Sahin, A.1    Basmak, H.2    Niyaz, L.3    Yildirim, N.4
  • 7
    • 38149099312 scopus 로고    scopus 로고
    • Accuracy of the ICare rebound tonometer in glaucomatous eyes with topical ocular hypotensive medication
    • A. Diaz, E. Yebra-Pimentel, C.G. Resua, J. Gilino, and M.J. Giraldez Accuracy of the ICare rebound tonometer in glaucomatous eyes with topical ocular hypotensive medication Ophthalmic Physiol Opt 28 2008 29 34
    • (2008) Ophthalmic Physiol Opt , vol.28 , pp. 29-34
    • Diaz, A.1    Yebra-Pimentel, E.2    Resua, C.G.3    Gilino, J.4    Giraldez, M.J.5
  • 8
    • 33644629030 scopus 로고    scopus 로고
    • Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes
    • C. García-Resúa, J.M. González-Meijome, J. Gilino, and E. Yebra-Pimentel Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes Optom Vis Sci 83 2006 102 107
    • (2006) Optom Vis Sci , vol.83 , pp. 102-107
    • García-Resúa, C.1    González-Meijome, J.M.2    Gilino, J.3    Yebra-Pimentel, E.4
  • 9
    • 42449089780 scopus 로고    scopus 로고
    • Comparison of the ICare rebound tonometer with the Goldmann applanation tonometer by experienced and inexperienced tonometrists
    • L.M. Abraham, N.C.R. Epasinghe, D. Selva, and R. Casson Comparison of the ICare rebound tonometer with the Goldmann applanation tonometer by experienced and inexperienced tonometrists Eye (Lond) 22 2008 503 506
    • (2008) Eye (Lond) , vol.22 , pp. 503-506
    • Abraham, L.M.1    Epasinghe, N.C.R.2    Selva, D.3    Casson, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.