메뉴 건너뛰기




Volumn 26, Issue 5, 2006, Pages 1305-1333

Virtopsy: Minimally invasive, imaging-guided virtual autopsy

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; AUTOPSY; COMPUTER ASSISTED DIAGNOSIS; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER GRAPHICS; COMPUTER INTERFACE; COMPUTER PROGRAM; HUMAN; IMAGE ENHANCEMENT; METHODOLOGY; MINIMALLY INVASIVE SURGERY; NUCLEAR MAGNETIC RESONANCE IMAGING; THREE DIMENSIONAL IMAGING;

EID: 33749496212     PISSN: 15271323     EISSN: 15271323     Source Type: Journal    
DOI: 10.1148/rg.265065001     Document Type: Article
Times cited : (389)

References (66)
  • 1
    • 0032517292 scopus 로고    scopus 로고
    • Low-tech autopsies in the era of high-tech medicine: Continued value for quality assurance and patient safety
    • Lundberg GD. Low-tech autopsies in the era of high-tech medicine: continued value for quality assurance and patient safety. JAMA 1998;280:1273-1274.
    • (1998) JAMA , vol.280 , pp. 1273-1274
    • Lundberg, G.D.1
  • 3
    • 33749456357 scopus 로고    scopus 로고
    • Gewalt im Röntgenbild: Befunde bei Krieg, Folter und Verbrechen
    • Vogel H. Gewalt im Röntgenbild: Befunde bei Krieg, Folter und Verbrechen. Echomed 1997;41:13-42.
    • (1997) Echomed , vol.41 , pp. 13-42
    • Vogel, H.1
  • 5
    • 0017778659 scopus 로고
    • A computer-tomographical examination of cranial bullet wounds
    • [in German]
    • Wullenweber R, Schneider V, Grumme T. A computer-tomographical examination of cranial bullet wounds [in German]. Z Rechtsmed 1977;80:227-246.
    • (1977) Z Rechtsmed , vol.80 , pp. 227-246
    • Wullenweber, R.1    Schneider, V.2    Grumme, T.3
  • 7
    • 0034003893 scopus 로고    scopus 로고
    • Preliminary experience with postmortem computed tomography in military penetrating trauma
    • Farkash U, Scope A, Lynn M, et al. Preliminary experience with postmortem computed tomography in military penetrating trauma. J Trauma 2000;48:303-308.
    • (2000) J Trauma , vol.48 , pp. 303-308
    • Farkash, U.1    Scope, A.2    Lynn, M.3
  • 8
    • 0029031598 scopus 로고
    • Three-dimensional reconstruction of a bullet path: Validation by computed radiography
    • Oliver WR, Chancellor AS, Soltys M, et al. Three-dimensional reconstruction of a bullet path: validation by computed radiography. J Forensic Sci 1995;40:321-324.
    • (1995) J Forensic Sci , vol.40 , pp. 321-324
    • Oliver, W.R.1    Chancellor, A.S.2    Soltys, M.3
  • 9
    • 0020563297 scopus 로고
    • Intravital and postmortal CT examinations in cerebral gunshot injuries
    • [in German]
    • Schumacher M, Oehmichen M, Konig HG, Einighammer H. Intravital and postmortal CT examinations in cerebral gunshot injuries [in German]. Rofo 1983;139:58-62.
    • (1983) Rofo , vol.139 , pp. 58-62
    • Schumacher, M.1    Oehmichen, M.2    Konig, H.G.3    Einighammer, H.4
  • 10
    • 0025351273 scopus 로고
    • Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation
    • Kalender WA, Seissler W, Klotz E, Vock P. Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation. Radiology 1990;176:181-183.
    • (1990) Radiology , vol.176 , pp. 181-183
    • Kalender, W.A.1    Seissler, W.2    Klotz, E.3    Vock, P.4
  • 11
    • 0031552025 scopus 로고    scopus 로고
    • Perinatal necropsy by magnetic resonance imaging
    • Berry PJ, Keeling JW, Wigglesworth JS. Perinatal necropsy by magnetic resonance imaging. Lancet 1997;349:55-56.
    • (1997) Lancet , vol.349 , pp. 55-56
    • Berry, P.J.1    Keeling, J.W.2    Wigglesworth, J.S.3
  • 12
    • 0032556413 scopus 로고    scopus 로고
    • Magnetic resonance imaging may be alternative to necropsy
    • [letter]
    • Bisset R. Magnetic resonance imaging may be alternative to necropsy [letter]. BMJ 1998;317:1450.
    • (1998) BMJ , vol.317 , pp. 1450
    • Bisset, R.1
  • 13
    • 0037097689 scopus 로고    scopus 로고
    • Postmortem examinations using magnetic resonance imaging: Four year review of a working service
    • Bisset RA, Thomas NB, Turnbull IW, Lee S. Postmortem examinations using magnetic resonance imaging: four year review of a working service. BMJ 2002;324:1423-1424.
    • (2002) BMJ , vol.324 , pp. 1423-1424
    • Bisset, R.A.1    Thomas, N.B.2    Turnbull, I.W.3    Lee, S.4
  • 14
    • 0033219776 scopus 로고    scopus 로고
    • Optimising imaging parameters for post mortem MR imaging of the human brain
    • Blamire AM, Rowe JG, Styles P, McDonald B. Optimising imaging parameters for post mortem MR imaging of the human brain. Acta Radiol 1999;40:593-597.
    • (1999) Acta Radiol , vol.40 , pp. 593-597
    • Blamire, A.M.1    Rowe, J.G.2    Styles, P.3    McDonald, B.4
  • 15
    • 0030603336 scopus 로고    scopus 로고
    • Non-invasive perinatal necropsy by magnetic resonance imaging
    • Brookes JA, Hall-Craggs MA, Sams VR, Lees WR. Non-invasive perinatal necropsy by magnetic resonance imaging. Lancet 1996;348:1139-1141.
    • (1996) Lancet , vol.348 , pp. 1139-1141
    • Brookes, J.A.1    Hall-Craggs, M.A.2    Sams, V.R.3    Lees, W.R.4
  • 16
    • 0033519772 scopus 로고    scopus 로고
    • Magnetic resonance necropsy is offered routinely in university college London hospitals
    • Brookes JA, Hall-Craggs M, Lees WR. Magnetic resonance necropsy is offered routinely in university college London hospitals. BMJ 1999;319:56-57.
    • (1999) BMJ , vol.319 , pp. 56-57
    • Brookes, J.A.1    Hall-Craggs, M.2    Lees, W.R.3
  • 17
    • 0029796471 scopus 로고    scopus 로고
    • Postmortem cranial MRI and autopsy correlation in suspected child abuse
    • Hart BL, Dudley MH, Zumwalt RE. Postmortem cranial MRI and autopsy correlation in suspected child abuse. Am J Forensic Med Pathol 1996;17:217-224.
    • (1996) Am J Forensic Med Pathol , vol.17 , pp. 217-224
    • Hart, B.L.1    Dudley, M.H.2    Zumwalt, R.E.3
  • 19
    • 0031552024 scopus 로고    scopus 로고
    • Perinatal necropsy by magnetic resonance imaging
    • [letter]
    • Niermeijer MF. Perinatal necropsy by magnetic resonance imaging [letter]. Lancet 1997;349:56.
    • (1997) Lancet , vol.349 , pp. 56
    • Niermeijer, M.F.1
  • 20
    • 0031022075 scopus 로고    scopus 로고
    • Post-mortem fetal MR imaging: Comparison with findings at autopsy
    • Woodward PJ, Sohaey R, Harris DP, et al. Post-mortem fetal MR imaging: comparison with findings at autopsy. AJR Am J Roentgenol 1997;168:41-46.
    • (1997) AJR Am J Roentgenol , vol.168 , pp. 41-46
    • Woodward, P.J.1    Sohaey, R.2    Harris, D.P.3
  • 22
    • 0035148654 scopus 로고    scopus 로고
    • Post-mortem whole-body magnetic resonance imaging as an adjunct to autopsy: Preliminary clinical experience
    • Patriquin L, Kassarjian A, Barish M, et al. Post-mortem whole-body magnetic resonance imaging as an adjunct to autopsy: preliminary clinical experience. J Magn Reson Imaging 2001;13:277-287.
    • (2001) J Magn Reson Imaging , vol.13 , pp. 277-287
    • Patriquin, L.1    Kassarjian, A.2    Barish, M.3
  • 23
    • 0025939336 scopus 로고
    • Postmortem magnetic resonance images of the injured brain: Effective evidence in the courtroom
    • Harris LS. Postmortem magnetic resonance images of the injured brain: effective evidence in the courtroom. Forensic Sci Int 1991;50:179-185.
    • (1991) Forensic Sci Int , vol.50 , pp. 179-185
    • Harris, L.S.1
  • 24
    • 0038451601 scopus 로고    scopus 로고
    • Forensic pathological aspects of postmortem imaging of gunshot injury to the head: Documentation and biometric data
    • (Berl)
    • Oehmichen M, Gehl HB, Meissner C, et al. Forensic pathological aspects of postmortem imaging of gunshot injury to the head: documentation and biometric data. Acta Neuropathol (Berl) 2003;105:570-580.
    • (2003) Acta Neuropathol , vol.105 , pp. 570-580
    • Oehmichen, M.1    Gehl, H.B.2    Meissner, C.3
  • 25
    • 0001965630 scopus 로고    scopus 로고
    • Photogrammetrische Auswertung von Haut- und Weichteilwunden sowie Knochenverletzungen zur Bestimmung des Tatwerkzeuges: Grundlegende Aspekte
    • Brueschweiler W, Braun M, Fuchser HJ, Dirnhofer R. Photogrammetrische Auswertung von Haut- und Weichteilwunden sowie Knochenverletzungen zur Bestimmung des Tatwerkzeuges: grundlegende Aspekte. Rechtsmedizin 1997;7:1976-1983.
    • (1997) Rechtsmedizin , vol.7 , pp. 1976-1983
    • Brueschweiler, W.1    Braun, M.2    Fuchser, H.J.3    Dirnhofer, R.4
  • 26
    • 33749496011 scopus 로고    scopus 로고
    • Virtopsy home page. Available at: Accessed June 2006
    • Virtopsy home page. Available at: http://www.virtopsy.com. Accessed June 2006.
  • 27
    • 0037346267 scopus 로고    scopus 로고
    • Virtopsy, a new imaging horizon in forensic pathology: Virtual autopsy by postmortem multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) - A feasibility study
    • Thali MJ, Yen K, Schweitzer W, et al. Virtopsy, a new imaging horizon in forensic pathology: virtual autopsy by postmortem multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) - a feasibility study. J Forensic Sci 2003;48:386-403.
    • (2003) J Forensic Sci , vol.48 , pp. 386-403
    • Thali, M.J.1    Yen, K.2    Schweitzer, W.3
  • 29
    • 13244286650 scopus 로고    scopus 로고
    • From the archives of the AFIP: A comprehensive review of fetal tumors with pathologic correlation
    • Woodward PJ, Sohaey R, Kennedy A, Koeller KK. From the archives of the AFIP: a comprehensive review of fetal tumors with pathologic correlation. RadioGraphics 2005;25:215-242.
    • (2005) RadioGraphics , vol.25 , pp. 215-242
    • Woodward, P.J.1    Sohaey, R.2    Kennedy, A.3    Koeller, K.K.4
  • 30
    • 28144461551 scopus 로고    scopus 로고
    • From the archives of the AFIP: Oligodendroglioma and its variants: radiologic-pathologic correlation
    • Koeller KK, Rushing EJ. From the archives of the AFIP: oligodendroglioma and its variants: radiologic-pathologic correlation. RadioGraphics 2005;25:1669-1688.
    • (2005) RadioGraphics , vol.25 , pp. 1669-1688
    • Koeller, K.K.1    Rushing, E.J.2
  • 31
    • 33645801797 scopus 로고    scopus 로고
    • Maximum intensity projection of cranial computed tomography data for dental identification
    • Jackowski C, Aghayev E, Sonnenschein M, Dirnhofer R, Thali MJ. Maximum intensity projection of cranial computed tomography data for dental identification. Int J Legal Med 2006;120(3):165-167.
    • (2006) Int J Legal Med , vol.120 , Issue.3 , pp. 165-167
    • Jackowski, C.1    Aghayev, E.2    Sonnenschein, M.3    Dirnhofer, R.4    Thali, M.J.5
  • 33
    • 33745278859 scopus 로고    scopus 로고
    • Extended CT scale overcomes restoration caused streak artifacts - 3D color encoded automatic discrimination of dental restorations for identification
    • Jackowski C, Lussi A, Classens M, et al. Extended CT scale overcomes restoration caused streak artifacts - 3D color encoded automatic discrimination of dental restorations for identification. J Comput Assist Tomogr 2006;30(3):510-513.
    • (2006) J Comput Assist Tomogr , vol.30 , Issue.3 , pp. 510-513
    • Jackowski, C.1    Lussi, A.2    Classens, M.3
  • 34
    • 34250369014 scopus 로고    scopus 로고
    • Use of multislice computed tomography in disaster victim identification: Advantages and limitations
    • (in press)
    • Sidler M, Jackowski C, Dirnhofer R, Vock P, Thali M. Use of multislice computed tomography in disaster victim identification: advantages and limitations. Forensic Sci Int (in press).
    • Forensic Sci Int
    • Sidler, M.1    Jackowski, C.2    Dirnhofer, R.3    Vock, P.4    Thali, M.5
  • 35
    • 29244433744 scopus 로고    scopus 로고
    • Does imaging technology overcome problems of conventional postmortem examination? A trial of computed tomography imaging for postmortem examination
    • Hayakawa M, Yamamoto S, Motani H, Yajima D, Sato Y, Iwase H. Does imaging technology overcome problems of conventional postmortem examination? a trial of computed tomography imaging for postmortem examination. Int J Legal Med 2006;120(1):24-26.
    • (2006) Int J Legal Med , vol.120 , Issue.1 , pp. 24-26
    • Hayakawa, M.1    Yamamoto, S.2    Motani, H.3    Yajima, D.4    Sato, Y.5    Iwase, H.6
  • 37
    • 0022643784 scopus 로고
    • Modern imaging and endoscopic biopsy techniques in Egyptian mummies
    • Notman DN, Tashjian J, Aufderheide AC, et al. Modern imaging and endoscopic biopsy techniques in Egyptian mummies. AJR Am J Roentgenol 1986;146:93-96.
    • (1986) AJR Am J Roentgenol , vol.146 , pp. 93-96
    • Notman, D.N.1    Tashjian, J.2    Aufderheide, A.C.3
  • 38
    • 0028124150 scopus 로고
    • Skull of a 5,300-year-old mummy: Reproduction and investigation with CT-guided stereolithography
    • zur Nedden D, Knapp R, Wicke K, et al. Skull of a 5,300-year-old mummy: reproduction and investigation with CT-guided stereolithography. Radiology 1994;193:269-272.
    • (1994) Radiology , vol.193 , pp. 269-272
    • Zur Nedden, D.1    Knapp, R.2    Wicke, K.3
  • 39
    • 4344622048 scopus 로고    scopus 로고
    • Virtopsy post-mortem multi-slice computed tomography (MSCT) and magnetic resonance imaging (MRI) demonstrating descending tonsillar herniation: Comparison to clinical studies
    • Aghayev E, Yen K, Sonnenschein M, et al. Virtopsy post-mortem multi-slice computed tomography (MSCT) and magnetic resonance imaging (MRI) demonstrating descending tonsillar herniation: comparison to clinical studies. Neuroradiology 2004;46:559-564.
    • (2004) Neuroradiology , vol.46 , pp. 559-564
    • Aghayev, E.1    Yen, K.2    Sonnenschein, M.3
  • 40
    • 33644843957 scopus 로고    scopus 로고
    • Adipocere in postmortem imaging using multislice computed tomography (MSCT) and magnetic resonance imaging (MRI)
    • Jackowski C, Thali M, Sonnenschein M, Aghayev E, Yen K, Dirnhofer R. Adipocere in postmortem imaging using multislice computed tomography (MSCT) and magnetic resonance imaging (MRI). Am J Forensic Med Pathol 2005;26(4):360-364.
    • (2005) Am J Forensic Med Pathol , vol.26 , Issue.4 , pp. 360-364
    • Jackowski, C.1    Thali, M.2    Sonnenschein, M.3    Aghayev, E.4    Yen, K.5    Dirnhofer, R.6
  • 41
    • 33644863598 scopus 로고    scopus 로고
    • Line scan diffusion tensor imaging of post-traumatic cervical spinal cord changes with neuropathological correlation
    • Yen K, Weis J, Kreis R, et al. Line scan diffusion tensor imaging of post-traumatic cervical spinal cord changes with neuropathological correlation. AJNR Am J Neuroradiol 2006;27(1):70-73.
    • (2006) AJNR Am J Neuroradiol , vol.27 , Issue.1 , pp. 70-73
    • Yen, K.1    Weis, J.2    Kreis, R.3
  • 42
    • 14244255902 scopus 로고    scopus 로고
    • Virtopsy: Postmortem imaging of the human heart in situ using MSCT and MRI
    • Jackowski C, Schweitzer W, Thali M, et al. Virtopsy: postmortem imaging of the human heart in situ using MSCT and MRI. Forensic Sci Int 2005;149:11-23.
    • (2005) Forensic Sci Int , vol.149 , pp. 11-23
    • Jackowski, C.1    Schweitzer, W.2    Thali, M.3
  • 43
    • 7544226182 scopus 로고    scopus 로고
    • Visualization and quantification of air embolism structure by processing postmortem MSCT data
    • Jackowski C, Thali M, Sonnenschein M, et al. Visualization and quantification of air embolism structure by processing postmortem MSCT data. J Forensic Sci 2004;49:1339-1342.
    • (2004) J Forensic Sci , vol.49 , pp. 1339-1342
    • Jackowski, C.1    Thali, M.2    Sonnenschein, M.3
  • 44
    • 33747836698 scopus 로고    scopus 로고
    • Intrahepatic gas at postmortem CT: Forensic experience as a potential guide for in vivo trauma imaging
    • (in press)
    • Jackowski C, Sonnenschein M, Thali M, et al. Intrahepatic gas at postmortem CT: forensic experience as a potential guide for in vivo trauma imaging. J Trauma (in press).
    • J Trauma
    • Jackowski, C.1    Sonnenschein, M.2    Thali, M.3
  • 45
    • 0345734439 scopus 로고    scopus 로고
    • Non-traumatic postmortem computed tomographic (PMCT) findings of the lung
    • Shiotani S, Kohno M, Ohashi N, et al. Non-traumatic postmortem computed tomographic (PMCT) findings of the lung. Forensic Sci Int 2004;139:39-48.
    • (2004) Forensic Sci Int , vol.139 , pp. 39-48
    • Shiotani, S.1    Kohno, M.2    Ohashi, N.3
  • 46
    • 20444372343 scopus 로고    scopus 로고
    • Postmortem diagnostics using MSCT and MRI of a lethal streptococcus group a infection at infancy: A case report
    • Jackowski C, Dirnhofer S, Thali M, Aghayev E, Dirnhofer R, Sonnenschein M. Postmortem diagnostics using MSCT and MRI of a lethal streptococcus group A infection at infancy: a case report. Forensic Sci Int 2005;151:157-163.
    • (2005) Forensic Sci Int , vol.151 , pp. 157-163
    • Jackowski, C.1    Dirnhofer, S.2    Thali, M.3    Aghayev, E.4    Dirnhofer, R.5    Sonnenschein, M.6
  • 47
    • 20444380020 scopus 로고    scopus 로고
    • Fatal steamer accident: Blunt force injuries and drowning in post-mortem MSCT and MRI
    • Aghayev E, Thali MJ, Sonnenschein M, et al. Fatal steamer accident: blunt force injuries and drowning in post-mortem MSCT and MRI. Forensic Sci Int 2005;152:65-71.
    • (2005) Forensic Sci Int , vol.152 , pp. 65-71
    • Aghayev, E.1    Thali, M.J.2    Sonnenschein, M.3
  • 48
    • 34347371589 scopus 로고    scopus 로고
    • Post-mortem MSCT and MRI in hypothermia: Benefits, limitations and new finding of hemorrhages in muscles of back
    • (in press)
    • Aghayev E, Thali MJ, Jackowski C, Sonnenschein M, Dirnhofer R, Yen K. Post-mortem MSCT and MRI in hypothermia: benefits, limitations and new finding of hemorrhages in muscles of back. Forensic Sci Int (in press).
    • Forensic Sci Int
    • Aghayev, E.1    Thali, M.J.2    Jackowski, C.3    Sonnenschein, M.4    Dirnhofer, R.5    Yen, K.6
  • 49
    • 33747116684 scopus 로고    scopus 로고
    • Fatal hemorrhage in postmortem radiology: Measurements of cross-sectional areas of major blood vessels and volumes of aorta and spleen by MSCT and volumes of heart chambers by MRI
    • Aghayev E, Sonnenschein M, Jackowski C, et al. Fatal hemorrhage in postmortem radiology: measurements of cross-sectional areas of major blood vessels and volumes of aorta and spleen by MSCT and volumes of heart chambers by MRI. AJR Am J Roentgenol 2006;187:209-215.
    • (2006) AJR Am J Roentgenol , vol.187 , pp. 209-215
    • Aghayev, E.1    Sonnenschein, M.2    Jackowski, C.3
  • 50
    • 33747855777 scopus 로고    scopus 로고
    • Non-invasive estimation of organ weights by postmortem MRI and MSCT imaging in consideration of intrahepatic gas due to putrefaction and air due to venous air embolism
    • Jackowski C, Thali M, Buck U, et al. Non-invasive estimation of organ weights by postmortem MRI and MSCT imaging in consideration of intrahepatic gas due to putrefaction and air due to venous air embolism. Invest Radiol 2006;41(7):572-578.
    • (2006) Invest Radiol , vol.41 , Issue.7 , pp. 572-578
    • Jackowski, C.1    Thali, M.2    Buck, U.3
  • 51
    • 24044483852 scopus 로고    scopus 로고
    • Pneumomediastinum and soft tissue emphysema of the neck in postmortem CT and MRI: A new vital sign in hanging?
    • Aghayev E, Yen K, Sonnenschein M, et al. Pneumomediastinum and soft tissue emphysema of the neck in postmortem CT and MRI: a new vital sign in hanging? Forensic Sci Int 2005;153:181-188.
    • (2005) Forensic Sci Int , vol.153 , pp. 181-188
    • Aghayev, E.1    Yen, K.2    Sonnenschein, M.3
  • 52
    • 3142762397 scopus 로고    scopus 로고
    • Virtopsy: Forensic traumatology of the subcutaneous fatty tissue: multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) as diagnostic tools
    • Yen K, Vock P, Tiefenthaler B, et al. Virtopsy: forensic traumatology of the subcutaneous fatty tissue: multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) as diagnostic tools. J Forensic Sci 2004;49:799-806.
    • (2004) J Forensic Sci , vol.49 , pp. 799-806
    • Yen, K.1    Vock, P.2    Tiefenthaler, B.3
  • 53
    • 33745203513 scopus 로고    scopus 로고
    • Postmortem imaging of blood and its characteristics using MSCT and MRI
    • Jackowski C, Thali M, Aghayev E, et al. Postmortem imaging of blood and its characteristics using MSCT and MRI. Int J Legal Med 2006;120(4)233-240.
    • (2006) Int J Legal Med , vol.120 , Issue.4 , pp. 233-240
    • Jackowski, C.1    Thali, M.2    Aghayev, E.3
  • 54
    • 0022907562 scopus 로고
    • Priority of multiple gunshot injuries of the skull
    • [in German]
    • Madea B, Henssge C, Lockhoven HB. Priority of multiple gunshot injuries of the skull [in German]. Z Rechtsmed 1986;97:213-218.
    • (1986) Z Rechtsmed , vol.97 , pp. 213-218
    • Madea, B.1    Henssge, C.2    Lockhoven, H.B.3
  • 55
    • 0036846443 scopus 로고    scopus 로고
    • Charred body: Virtual autopsy with multi-slice computed tomography and magnetic resonance imaging
    • Thali MJ, Yen K, Plattner T, et al. Charred body: virtual autopsy with multi-slice computed tomography and magnetic resonance imaging. J Forensic Sci 2002;47:1326-1331.
    • (2002) J Forensic Sci , vol.47 , pp. 1326-1331
    • Thali, M.J.1    Yen, K.2    Plattner, T.3
  • 56
    • 0038309925 scopus 로고    scopus 로고
    • Into the decomposed body: Forensic digital autopsy using multislice-computed tomography
    • Thali MJ, Yen K, Schweitzer W, Vock P, Ozdoba C, Dirnhofer R. Into the decomposed body: forensic digital autopsy using multislice-computed tomography. Forensic Sci Int 2003;134:109-114.
    • (2003) Forensic Sci Int , vol.134 , pp. 109-114
    • Thali, M.J.1    Yen, K.2    Schweitzer, W.3    Vock, P.4    Ozdoba, C.5    Dirnhofer, R.6
  • 57
    • 24644491195 scopus 로고    scopus 로고
    • Virtopsy: Postmortem minimally invasive angiography using cross section techniques - Implementation and preliminary results
    • Jackowski C, Sonnenschein M, Thali MJ, et al. Virtopsy: postmortem minimally invasive angiography using cross section techniques - implementation and preliminary results. J Forensic Sci 2005;50:1175-1186.
    • (2005) J Forensic Sci , vol.50 , pp. 1175-1186
    • Jackowski, C.1    Sonnenschein, M.2    Thali, M.J.3
  • 58
    • 85060840303 scopus 로고    scopus 로고
    • Post-mortem angiography after vascular perfusion with diesel oil and a lipophilic contrast agent
    • (in press)
    • Grabherr S, Djonov V, Friess A, et al. Post-mortem angiography after vascular perfusion with diesel oil and a lipophilic contrast agent. AJR Am J Roentgenol (in press).
    • AJR Am J Roentgenol
    • Grabherr, S.1    Djonov, V.2    Friess, A.3
  • 59
    • 0030071062 scopus 로고    scopus 로고
    • A microtomographic system for the nondestructive evaluation of bone architecture
    • Ruegsegger P, Koller B, Muller R. A microtomographic system for the nondestructive evaluation of bone architecture. Calcif Tissue Int 1996;58:24-29.
    • (1996) Calcif Tissue Int , vol.58 , pp. 24-29
    • Ruegsegger, P.1    Koller, B.2    Muller, R.3
  • 60
    • 0242442634 scopus 로고    scopus 로고
    • Forensic microradiology: Micro-computed tomography (Micro-CT) and analysis of patterned injuries inside of bone
    • Thali MJ, Taubenreuther U, Karolczak M, et al. Forensic microradiology: micro-computed tomography (Micro-CT) and analysis of patterned injuries inside of bone. J Forensic Sci 2003;48:1336-1342.
    • (2003) J Forensic Sci , vol.48 , pp. 1336-1342
    • Thali, M.J.1    Taubenreuther, U.2    Karolczak, M.3
  • 62
    • 7544232172 scopus 로고    scopus 로고
    • Is 'virtual histology' the next step after the 'virtual autopsy'? Magnetic resonance microscopy in forensic medicine
    • Thali MJ, Dirnhofer R, Becker R, Oliver W, Potter K. Is 'virtual histology' the next step after the 'virtual autopsy'? magnetic resonance microscopy in forensic medicine. Magn Reson Imaging 2004;22:1131-1138.
    • (2004) Magn Reson Imaging , vol.22 , pp. 1131-1138
    • Thali, M.J.1    Dirnhofer, R.2    Becker, R.3    Oliver, W.4    Potter, K.5
  • 63
    • 14844293464 scopus 로고    scopus 로고
    • VIRTOPSY: Scientific documentation, reconstruction and animation in forensics: individual and real 3D data based geometric approach including optical body/object surface and radiological CT/MRI scanning
    • Thali MJ, Braun M, Buck U, et al. VIRTOPSY: scientific documentation, reconstruction and animation in forensics: individual and real 3D data based geometric approach including optical body/object surface and radiological CT/MRI scanning. J Forensic Sci 2005;50:428-442.
    • (2005) J Forensic Sci , vol.50 , pp. 428-442
    • Thali, M.J.1    Braun, M.2    Buck, U.3
  • 64
    • 0242695004 scopus 로고    scopus 로고
    • 3D surface and body documentation in forensic medicine: 3-D/CAD Photogrammetry merged with 3D radiological scanning
    • Thali MJ, Braun M, Wirth J, Vock P, Dirnhofer R. 3D surface and body documentation in forensic medicine: 3-D/CAD Photogrammetry merged with 3D radiological scanning. J Forensic Sci 2003;48:1356-1365.
    • (2003) J Forensic Sci , vol.48 , pp. 1356-1365
    • Thali, M.J.1    Braun, M.2    Wirth, J.3    Vock, P.4    Dirnhofer, R.5
  • 65
    • 26244459836 scopus 로고    scopus 로고
    • Strangulation signs: Initial correlation of MRI, MSCT and forensic neck findings
    • Yen K, Thali M, Aghayev E, et al. Strangulation signs: initial correlation of MRI, MSCT and forensic neck findings. J Magn Reson Imaging 2005;22(4):501-510.
    • (2005) J Magn Reson Imaging , vol.22 , Issue.4 , pp. 501-510
    • Yen, K.1    Thali, M.2    Aghayev, E.3
  • 66
    • 33749460875 scopus 로고    scopus 로고
    • The Japan Society of Autopsy Imaging home page. Available at: Accessed June 2006
    • The Japan Society of Autopsy Imaging home page. Available at: http://plaza.umin.ac.jp/%7Eai-ai/english.htm. Accessed June 2006.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.