Volumn 33, Issue 6, 2012, Pages 544-549

Guideline for technical quality assurance (TQA) of ultrasound devices (B-Mode) - Version 10 (July 2012)

Author keywords

physics; QA QC; safety; technical aspects; ultrasound

Indexed keywords

CLINICAL COMPETENCE; COMPUTER ASSISTED DIAGNOSIS; COMPUTER PROGRAM; CONFERENCE PAPER; CONSENSUS DEVELOPMENT; ECHOGRAPHY; EQUIPMENT; EQUIPMENT DESIGN; EUROPE; HEALTH CARE QUALITY; HUMAN; IMAGE QUALITY; PRACTICE GUIDELINE; QUALITY CONTROL; STANDARD;

EID: 84870863278     PISSN: 01724614     EISSN: 14388782     Source Type: Journal    
DOI: 10.1055/s-0032-1325347     Document Type: Article
Times cited : (44)

References (34)
  • 1
    • 78650054415 scopus 로고    scopus 로고
    • Evaluation of a low-cost liquid ultrasound test object for detection of transducer artefacts
    • King D. M., Hangiandreou N. J., Tradup D. J. et al. Evaluation of a low-cost liquid ultrasound test object for detection of transducer artefacts. Phys Med Biol: 2010; 55 N557 N570
    • (2010) Phys Med Biol , vol.55
    • King, D.M.1    Hangiandreou, N.J.2    Tradup, D.J.3
  • 3
    • 0035712366 scopus 로고    scopus 로고
    • A computerised quality control testing system for B-mode ultrasound
    • DOI 10.1016/S0301-5629(01)00479-3, PII S0301562901004793
    • Gibson N. M., Dudley N. J., Griffith K. A Computerised Ultrasound Quality Control Testing System. Ultrasound Med Biol: 2001; 27 1697 1711 (Pubitemid 34143131)
    • (2001) Ultrasound in Medicine and Biology , vol.27 , Issue.12 , pp. 1697-1711
    • Gibson, N.M.1    Dudley, N.J.2    Griffith, K.3
  • 5
    • 33847038380 scopus 로고    scopus 로고
    • Objective performance testing and quality assurance of medical ultrasound equipment
    • DOI 10.1016/j.ultrasmedbio.2006.09.006, PII S0301562906018588
    • Thijssen J. M., Weijers G., deKorte C. L. Objective performance testing and quality assurance of medical ultrasound equipment. Ultrasound Med Biol: 2007; 33 460 471 (Pubitemid 46275192)
    • (2007) Ultrasound in Medicine and Biology , vol.33 , Issue.3 , pp. 460-471
    • Thijssen, J.M.1    Weijers, G.2    De Korte, C.L.3
  • 8
    • 84870937124 scopus 로고    scopus 로고
    • American College of Radiology (ACR) www.acr.org/Quality-Safety/ Accreditation/Ultrasound (accessed 26.6.2012)
    • American College of Radiology (ACR) Ultrasound Accreditation Program Requirements; revision 3/23/12. www.acr.org/Quality-Safety/Accreditation/ Ultrasound (accessed 26.6.2012)
    • Ultrasound Accreditation Program Requirements; Revision 3/23/12
  • 25
    • 84870878902 scopus 로고    scopus 로고
    • American Association of Physicists in Medicne (AAPM) (accessed 26.6.2012)
    • American Association of Physicists in Medicne (AAPM) Real-time B-mode ultrasound quality control test procedures. 1998; www.aapm.org/pubs/reports/rpt- 65.pdf (accessed 26.6.2012)
    • (1998) Real-time B-mode Ultrasound Quality Control Test Procedures
  • 31
    • 79959839401 scopus 로고    scopus 로고
    • Four-year experience with a clinical ultrasound Quality Control program
    • Hangiandreou N. J., Stekel S. F., Tradup D. J. et al. Four-year experience with a clinical ultrasound Quality Control program. Ultrasound Med Biol: 2011; 37 1350 1357
    • (2011) Ultrasound Med Biol , vol.37 , pp. 1350-1357
    • Hangiandreou, N.J.1    Stekel, S.F.2    Tradup, D.J.3
  • 32
    • 64749104230 scopus 로고    scopus 로고
    • High incidence of defective ultrasound transducers in use in routine clinical practice
    • Martensson M., Olsson M., Segall B. et al. High incidence of defective ultrasound transducers in use in routine clinical practice. Eur J Echocardiogr: 2009; 10 389 394
    • (2009) Eur J Echocardiogr , vol.10 , pp. 389-394
    • Martensson, M.1    Olsson, M.2    Segall, B.3
  • 33
    • 84992792951 scopus 로고    scopus 로고
    • The need for evidence-based quality assurance in the modern ultrasound clinical laboratory
    • Moore G. W., Gessert A., Schafer M. The need for evidence-based quality assurance in the modern ultrasound clinical laboratory. Ultrasound: 2005; 13 158 162
    • (2005) Ultrasound , vol.13 , pp. 158-162
    • Moore, G.W.1    Gessert, A.2    Schafer, M.3
  • 34
    • 77957981090 scopus 로고    scopus 로고
    • Ultrasound transducer function: Annual testing is not sufficient
    • Martensson M., Olsson M., Brodin L. A. Ultrasound transducer function: Annual testing is not sufficient. Eur J Echocardiogr: 2010; 11 801 805
    • (2010) Eur J Echocardiogr , vol.11 , pp. 801-805
    • Martensson, M.1    Olsson, M.2    Brodin, L.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.