Volumn 10, Issue 3, 2009, Pages 389-394

High incidence of defective ultrasound transducers in use in routine clinical practice

Author keywords

Defect; Error; Probe; Test; Transducer; Ultrasound

Indexed keywords

ARTICLE; CLINICAL PRACTICE; ELECTRIC ACTIVITY; ERROR; HISTOGRAM; HOSPITAL DEPARTMENT; MEDICAL DECISION MAKING; PIEZOELECTRICITY; PRIORITY JOURNAL; SENSITIVITY ANALYSIS; ULTRASOUND TRANSDUCER;

EID: 64749104230     PISSN: 15252167     EISSN: 15322114     Source Type: Journal    
DOI: 10.1093/ejechocard/jen295     Document Type: Article
Times cited : (54)

References (20)
  • 2
    • 33745712206 scopus 로고    scopus 로고
    • Automated quality control of ultrasonic B-mode scanners by applying an TMM 3D cyst phantom
    • Satrapa J, Doblhoff G, Schultz HJ. Automated quality control of ultrasonic B-mode scanners by applying an TMM 3D cyst phantom. Ultraschall Med 2006; 27:262-72.
    • (2006) Ultraschall Med , vol.27 , pp. 262-272
    • Satrapa, J.1    Doblhoff, G.2    Schultz, H.J.3
  • 3
    • 0037237280 scopus 로고    scopus 로고
    • The Method and Effects of Transducer degradation on image quality and the clinical efficacy of diagnostic sonography
    • Weigang B, Moore GW, Gessert J, Phillips WH, Schafer M. The Method and Effects of Transducer degradation on image quality and the clinical efficacy of diagnostic sonography. J Diagn Med Sonog 2002; 19:3-13.
    • (2002) J Diagn Med Sonog , vol.19 , pp. 3-13
    • Weigang, B.1    Moore, G.W.2    Gessert, J.3    Phillips, W.H.4    Schafer, M.5
  • 8
    • 0031814617 scopus 로고    scopus 로고
    • Real-time B-mode ultrasound quality control test procedures. Report of AAPM Ultrasound Task Group No. 1
    • Goodsitt MM, Carson PL, Witt S, Hykes DL, Kofler JM. Real-time B-mode ultrasound quality control test procedures. Report of AAPM Ultrasound Task Group No. 1. Med Phys 1998; 25:1385-406.
    • (1998) Med Phys , vol.25 , pp. 1385-1406
    • Goodsitt, M.M.1    Carson, P.L.2    Witt, S.3    Hykes, D.L.4    Kofler, J.M.5
  • 9
    • 0011228451 scopus 로고
    • Routine quality assurance of ultrasound imaging systems
    • No. 71. The Institute of Physical Sciences in Medicine
    • Price R. Routine quality assurance of ultrasound imaging systems. IPSM Report No. 71. The Institute of Physical Sciences in Medicine, 1995.
    • (1995) IPSM Report
    • Price, R.1
  • 10
    • 0017136411 scopus 로고
    • Rapid evaluation of many pulse echo system characteristics by use of a triggered pulse burst generator with exponential decay
    • Carson PL. Rapid evaluation of many pulse echo system characteristics by use of a triggered pulse burst generator with exponential decay. J Clin Ultrasound 1976; 4:259-63.
    • (1976) J Clin Ultrasound , vol.4 , pp. 259-263
    • Carson, P.L.1
  • 12
    • 0035712366 scopus 로고    scopus 로고
    • A computerised quality control testing system for B-mode ultrasound
    • Gibson NM, Dudley NJ, Griffith K. A computerised quality control testing system for B-mode ultrasound. Ultrasound Med Biol 2001; 27: 1697-711.
    • (2001) Ultrasound Med Biol , vol.27 , pp. 1697-1711
    • Gibson, N.M.1    Dudley, N.J.2    Griffith, K.3
  • 13
    • 0018034877 scopus 로고
    • A method of calibrating contact B-scanners
    • Hall AJ, Fleming JEE. A method of calibrating contact B-scanners. Ultrasonics 1978;277-81.
    • (1978) Ultrasonics , pp. 277-281
    • Hall, A.J.1    Fleming, J.E.E.2
  • 14
    • 64749092745 scopus 로고    scopus 로고
    • Quality assurance for gray-scale imaging
    • Madsen EL. Quality assurance for gray-scale imaging. Ultrasound Med Biol 2002; 26:45-50.
    • (2002) Ultrasound Med Biol , vol.26 , pp. 45-50
    • Madsen, E.L.1
  • 15
    • 67649339868 scopus 로고    scopus 로고
    • Medical ultrasound: A new metric of performance for grey-scale imaging
    • Pye SD, Ellis W, MacGillivray T. Medical ultrasound: a new metric of performance for grey-scale imaging.. J Phys 2004; 1:187-92.
    • (2004) J Phys , vol.1 , pp. 187-192
    • Pye, S.D.1    Ellis, W.2    MacGillivray, T.3
  • 17
    • 0031987372 scopus 로고    scopus 로고
    • Development of an example flow test object and comparison of five of these test objects, constructed in various laboratories
    • Teirlink CJPM, Bezemer RA, Kollmann C, Lubbers J, Hoskins PR, Fish P et al. Development of an example flow test object and comparison of five of these test objects, constructed in various laboratories. Ultrasonics 1998; 36:653-60.
    • (1998) Ultrasonics , vol.36 , pp. 653-660
    • Teirlink, C.J.P.M.1    Bezemer, R.A.2    Kollmann, C.3    Lubbers, J.4    Hoskins, P.R.5    Fish, P.6
  • 18
    • 33847038380 scopus 로고    scopus 로고
    • Objective performance testing and quality assurance of medical ultrasound equipment
    • Thijssen JM, Weijers G, de Korte CL. Objective performance testing and quality assurance of medical ultrasound equipment. Ultrasound Med Biol 2007; 33:460-71.
    • (2007) Ultrasound Med Biol , vol.33 , pp. 460-471
    • Thijssen, J.M.1    Weijers, G.2    de Korte, C.L.3
  • 19


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.