1
-
-
13844254144
-
Recent important changes in IEEE motor and generator winding insulation diagnostic testing standards
-
DOI 10.1109/TIA.2004.840977
-
G.C. Stone, "Recent important changes in IEEE motor and generator winding insulation diagnostic testing standards", IEEE Trans. Industry Applications, vol. 41, no. 1, pp. 91-100, Jan.-Feb. 2005. (Pubitemid 40241995)
-
(2005)
IEEE Transactions on Industry Applications
, vol.41
, Issue.1
, pp. 91-100
-
-
Stone, G.C.1
-
2
-
-
51849084932
-
Experience with continuous on-line partial discharge monitoring of generators and motors", in
-
G.C. Stone, B. Lloyd, M. Sasic, "Experience with continuous on-line partial discharge monitoring of generators and motors", in Proc. of International Conference on Condition Monitoring and Diagnosis, pp. 212-216, 2008.
-
(2008)
Proc. of International Conference on Condition Monitoring and Diagnosis
, pp. 212-216
-
-
Stone, G.C.1
Lloyd, B.2
Sasic, M.3
-
3
-
-
84870828172
-
A review of on-line condition monitoring techniques for three-phase squirrel-cage induction motors-past, present and future", in
-
W.T. Thomson, "A review of on-line condition monitoring techniques for three-phase squirrel-cage induction motors-past, present and future", in Proc. of SDEMPED'99, pp. 1-16, 1999.
-
(1999)
Proc. of SDEMPED
, vol.99
, pp. 1-16
-
-
Thomson, W.T.1
-
4
-
-
32144440132
-
On-line stator fault diagnosis in low voltage induction motors
-
39th International Universities Power Engineering Conference, UPEC 2004 - Conference Proceedings
-
I. Albizu, I. Zamora, A.J. Mazon, J.R. Saenz, A. Tapia, "On-line stator fault diagnosis in low voltage induction motors", in Proc. of UPEC 2004, pp. 504-508, 2004. (Pubitemid 43205940)
-
(2004)
39th International Universities Power Engineering Conference, UPEC 2004 - Conference Proceedings
, vol.1
, pp. 504-508
-
-
Albizu, I.1
Zamora, I.2
Mazon, A.J.3
Saenz, J.R.4
Tapia, A.5
-
5
-
-
15044343813
-
A review of stator fault monitoring techniques of induction motors
-
DOI 10.1109/TEC.2004.837304
-
A. Siddique, "A Review of Stator Fault Monitoring Techniques of Induction Motors", IEEE Trans. Energy Conversion, vol. 20, no. 1, pp. 106-114, Mar. 2005. (Pubitemid 40377529)
-
(2005)
IEEE Transactions on Energy Conversion
, vol.20
, Issue.1
, pp. 106-114
-
-
Siddique, A.1
Yadava, G.S.2
Singh, B.3
-
6
-
-
0030388550
-
A new approach to on-line fault detection in ac motors," in
-
San Diego, CA
-
G.B. Kliman, W.J. Premerlani, R.A. Koegl, and D. Hoeweler, "A new approach to on-line fault detection in ac motors," in Proc. IEEE Industry Applications Soc. Annual Meeting Conf., San Diego, CA, 1996, pp. 687-693.
-
(1996)
Proc. IEEE Industry Applications Soc. Annual Meeting Conf.
, pp. 687-693
-
-
Kliman, G.B.1
Premerlani, W.J.2
Koegl, R.A.3
Hoeweler, D.4
-
8
-
-
0028742406
-
Detection and location of interturn short circuits in the stator windings of operating motors
-
Dec
-
J. Penman, H.G. Sedding, B.A. Lloyd, and W.T. Fink, "Detection and location of interturn short circuits in the stator windings of operating motors," IEEE Trans. Energy Conversion, vol. 9, no. 4, pp. 652-658, Dec. 1994.
-
(1994)
IEEE Trans. Energy Conversion
, vol.9
, Issue.4
, pp. 652-658
-
-
Penman, J.1
Sedding, H.G.2
Lloyd, B.A.3
Fink, W.T.4
-
9
-
-
0035274989
-
Current monitoring for detecting inter-turn short circuits in induction motors
-
DOI 10.1109/60.911400, PII S0885896901026523
-
A. Stavrou, H.G. Sedding, J. Penman, "Current monitoring for detecting inter-turn short circuits in induction motors", IEEE Trans. Energy Conversion, vol. 16, no. 1, pp. 32-37, Mar. 2001. (Pubitemid 32302940)
-
(2001)
IEEE Transactions on Energy Conversion
, vol.16
, Issue.1
, pp. 32-37
-
-
Stavrou, A.1
Sedding, H.G.2
Penman, J.3
-
10
-
-
84886817982
-
On-line mcsa to diagnose shorted turns in low voltage stator windings of 3-phase induction motors prior to failure", in
-
W.T. Thomson, "On-line MCSA to diagnose shorted turns in low voltage stator windings of 3-phase induction motors prior to failure", in Proc. IEMDC 2001, pp. 891-898.
-
Proc. IEMDC
, vol.2001
, pp. 891-898
-
-
Thomson, W.T.1
-
11
-
-
0036754027
-
Condition monitoring of stator windings in induction motors: Part I - Experimental investigation of the effective negative-sequence impedance detector
-
DOI 10.1109/TIA.2002.802935, PII 1011092002802935
-
J. Sottile, F.C. Trutt, J.L. Kohler, "Condition monitoring of stator windings in induction motors. Part I. Experimental Investigation of the Effective Negative-Sequence Impedance Detector", IEEE Trans. Industry Applications, vol. 38, no. 5, pp. 1447-1453, Sep./Oct 2002. (Pubitemid 35303260)
-
(2002)
IEEE Transactions on Industry Applications
, vol.38
, Issue.5
, pp. 1447-1453
-
-
Kohler, J.L.1
Sottile, J.2
Trutt, F.C.3
-
12
-
-
0036754470
-
Condition monitoring of stator windings in induction motors: Part II - Experimental investigation of voltage mismatch detectors
-
DOI 10.1109/TIA.2002.802921, PII 1011092002802921
-
J. Sottile, F.C. Trutt, J.L. Kohler, "Condition monitoring of stator windings in induction motors. Part II. Experimental investigation of voltage mismatch detectors", IEEE Trans. Industry Applications, vol. 38, no. 5, pp. 1454-1459, Sep./Oct 2002. (Pubitemid 35303261)
-
(2002)
IEEE Transactions on Industry Applications
, vol.38
, Issue.5
, pp. 1454-1459
-
-
Sottile, J.1
Trutt, F.C.2
Kohler, J.L.3
-
13
-
-
0242274222
-
A frequency-domain detection of stator winding faults in induction machines using an external flux sensor
-
H. Henao, C. Demian, and G.A. Capolino, "A frequency-domain detection of stator winding faults in induction machines using an external flux sensor", IEEE Trans. Ind. Appl., 39(5), pp. 1272-1279, 2003.
-
(2003)
IEEE Trans. Ind. Appl.
, vol.39
, Issue.5
, pp. 1272-1279
-
-
Henao, H.1
Demian, C.2
Capolino, G.A.3
-
14
-
-
0242424465
-
On the stray flux analysis for the detection of the three-phase induction machine faults," in
-
Oct
-
H. Henao, G.A. Capolino, and C. Martis, "On the stray flux analysis for the detection of the three-phase induction machine faults," in Proc. IAS'03, pp. 1368-1373, Oct. 2003.
-
(2003)
Proc. IAS'03
, pp. 1368-1373
-
-
Henao, H.1
Capolino, G.A.2
Martis, C.3
-
15
-
-
27944470310
-
Detection of stator short-circuit in induction machines using an external leakage flux sensor
-
Proceedings of the 2004 IEEE International Conference on Industrial Technology, ICIT
-
A. Yazidi, D. Thailly, H. Henao, R. Romary, G. A. Capolino, and J. F. Brudny, "Detection of stator short circuit in induction machine using an external leakage flux sensor," in Proc. ICIT, pp. 166-169, 2004. (Pubitemid 41675155)
-
(2004)
Proceedings of the IEEE International Conference on Industrial Technology
, vol.1
, pp. 166-169
-
-
Yazidi, A.1
Thailly, D.2
Henao, H.3
Romary, R.4
Capolino, G.-A.5
Brudny, J.-F.6
-
16
-
-
31444436593
-
Simplified axial flux spectrum method to detect incipient stator inter-turn short-circuits in induction machine
-
May
-
T. Assaf, H. Henao, G.A. Capolino, "Simplified axial flux spectrum method to detect incipient stator inter-turn short-circuits in induction machine", IEEE International Symposium on Industrial Electronics, vol. 2, pp. 815-819, May 2004.
-
(2004)
IEEE International Symposium on Industrial Electronics
, vol.2
, pp. 815-819
-
-
Assaf, T.1
Henao, H.2
Capolino, G.A.3
-
17
-
-
51549086519
-
Flux signature analysis: An alternative method for the fault diagnosis of induction machines", in
-
A. Yazidi, H. Henao, G.A. Capolino, M. Artioli, F. Filippetti, and D. Casadei, "Flux signature analysis: an alternative method for the fault diagnosis of induction machines", in Proc. of IEEE Power Tech, pp. 1-6, 2005.
-
(2005)
Proc. of IEEE Power Tech
, pp. 1-6
-
-
Yazidi, A.1
Henao, H.2
Capolino, G.A.3
Artioli, M.4
Filippetti, F.5
Casadei, D.6
-
18
-
-
5444235814
-
Diagnosis of stator inter-turn short circuits in dtc induction motordrives
-
S.M.A. Cruz, A.J.M. Cardoso, '"Diagnosis of stator inter-turn short circuits in DTC induction motordrives", IEEE Trans. Industry Applications, vol. 40, no. 5, pp. 1349-1360, 2004.
-
(2004)
IEEE Trans. Industry Applications
, vol.40
, Issue.5
, pp. 1349-1360
-
-
Cruz, S.M.A.1
Cardoso, A.J.M.2
-
19
-
-
84870845334
-
Study of an induction motor working under stator winding inter-turn short circuit condition", in
-
Aug
-
M.G. Melero, M.F. Cabanas, C. Rojas, G.A. Orcajo, J.M. Cano, J.Solares, "Study of an induction motor working under stator winding inter-turn short circuit condition", in Proc. SDEMPED 2003, pp. 52-57, Aug. 2003.
-
(2003)
Proc. SDEMPED
, vol.2003
, pp. 52-57
-
-
Melero, M.G.1
Cabanas, M.F.2
Rojas, C.3
Orcajo, G.A.4
Cano, J.M.5
Solares, J.6
-
20
-
-
29444455648
-
Induction machine fault diagnosis using an external radial flux sensor
-
DOI 10.1051/epjap:2005079
-
R. Romary, R. Corton, D. Thailly, and J.F. Brudny, "Induction Machine Faults Diagnosis using an External Radial Flux Sensor", The European Physical Journal of Applied Physics, 32, 125-132, 2005. (Pubitemid 43010851)
-
(2005)
EPJ Applied Physics
, vol.32
, Issue.2
, pp. 125-132
-
-
Romary, R.1
Corton, R.2
Thailly, D.3
Brudny, J.F.4
-
21
-
-
33947637062
-
Quantitative analysis of the external radial magnetic field for detection of stator inter-turn shortcircuit in induction machines", in
-
Sep
-
D. Thailly, R. Romary, J-F. Brudny, "Quantitative analysis of the external radial magnetic field for detection of stator inter-turn shortcircuit in induction machines", in Proc. EPE 2005, Sep. 2005.
-
(2005)
Proc. EPE
, vol.2005
-
-
Thailly, D.1
Romary, R.2
Brudny, J.-F.3
-
22
-
-
44649087354
-
Electromagnetic flux monitoring for detecting faults in electrical machines
-
Helsinki University of Technology
-
M.D. Negrea, "Electromagnetic flux monitoring for detecting faults in electrical machines", Doctoral Dissertation, Helsinki University of Technology, 2006.
-
(2006)
Doctoral Dissertation
-
-
Negrea, M.D.1
-
23
-
-
5044244199
-
Electrical insulation for rotating machines: Design, evaluation, aging, testing, and repair
-
G.C. Stone, E.A. Boulter, I. Culbert, H. Dhirani, Electrical insulation for rotating machines: design, evaluation, aging, testing, and repair, IEEE Press, 2004.
-
(2004)
IEEE Press
-
-
Stone, G.C.1
Boulter, E.A.2
Culbert, I.3
Dhirani, H.4
-
24
-
-
81255176204
-
Development of a leakage flux measurement system for condition monitoring of electrical drives", in
-
L. Frosini, A. Borin, L. Girometta, G. Venchi, "Development of a leakage flux measurement system for condition monitoring of electrical drives", in Proc. SDEMPED 2011, pp. 1-8, 2011.
-
(2011)
Proc. SDEMPED
, pp. 1-8
-
-
Frosini, L.1
Borin, A.2
Girometta, L.3
Venchi, G.4
|