메뉴 건너뛰기




Volumn 17, Issue 10, 2012, Pages

In vivo estimation of elastic wave parameters using phase-stabilized swept source optical coherence elastography

Author keywords

Biomechanical properties; Elastic wave; Elastography; In vivo; Ocular tissues; Optical coherence tomography; Phase sensitive; Shear wave

Indexed keywords

ACOUSTIC WAVE VELOCITY; BIOMECHANICS; ELASTIC WAVES; HISTOLOGY; MAMMALS; MEDICAL IMAGING; OPTICAL TOMOGRAPHY; SHEAR WAVES; TISSUE; WAVE PROPAGATION;

EID: 84870766358     PISSN: 10833668     EISSN: 15602281     Source Type: Journal    
DOI: 10.1117/1.JBO.17.10.100501     Document Type: Article
Times cited : (50)

References (35)
  • 1
    • 0017108327 scopus 로고
    • Causes of blindness among students in blind school institutions in a developing country
    • M. C. Chirambo and D. Benezra, Causes of blindness among students in blind school institutions in a developing country, Br. J. Ophthalmol. 60(9), 665-668 (1976).
    • (1976) Br. J. Ophthalmol. , vol.60 , Issue.9 , pp. 665-668
    • Chirambo, M.C.1    Benezra, D.2
  • 2
    • 0036910912 scopus 로고    scopus 로고
    • Progressive post-LASIK eratectasia: Biomechanical instability or chronic disease process?
    • DOI 10.1016/S0886-3350(02)01698-X, PII S088633500201698X
    • I. F. Comaish and M. A. Lawless, Progressive post-LASIK keratectasia: Biomechanical instability or chronic disease process, J. Cataract Refractive Surg. 28(12), 2206-2213 (2002). (Pubitemid 36032719)
    • (2002) Journal of Cataract and Refractive Surgery , vol.28 , Issue.12 , pp. 2206-2213
    • Comaish, I.F.1    Lawless, M.A.2
  • 3
    • 0030888970 scopus 로고    scopus 로고
    • Keratoconus: Diagnosis and treatment
    • DOI 10.1097/00004397-199703710-00005
    • L. T. Nordan, Keratoconus: Diagnosis and treatment, Int. Ophthalmol. Clin. 37(1), 51-63 (1997). (Pubitemid 27149006)
    • (1997) International Ophthalmology Clinics , vol.37 , Issue.1 , pp. 51-63
    • Nordan, L.T.1
  • 5
    • 33847014493 scopus 로고    scopus 로고
    • Assessment of corneal biomechanical properties and their variation with age
    • A. Elsheikh et al., Assessment of corneal biomechanical properties and their variation with age, Curr. Eye Res. 32(1), 11-19 (2007).
    • (2007) Curr. Eye Res. , vol.32 , Issue.1 , pp. 11-19
    • Elsheikh, A.1
  • 7
    • 77954133261 scopus 로고    scopus 로고
    • MR elastography of the ex vivo bovine globe
    • D. V. Litwiller et al., MR elastography of the ex vivo bovine globe, J. Magn. Reson. Imaging 32(1), 44-51 (2010).
    • (2010) J. Magn. Reson. Imaging , vol.32 , Issue.1 , pp. 44-51
    • Litwiller, D.V.1
  • 8
    • 72249104685 scopus 로고    scopus 로고
    • High-resolution quantitative imaging of cornea elasticity using supersonic shear imaging
    • M. Tanter et al., High-resolution quantitative imaging of cornea elasticity using supersonic shear imaging, IEEE Trans. Med. Imag. 28(12), 1881-1893 (2009).
    • (2009) IEEE Trans. Med. Imag. , vol.28 , Issue.12 , pp. 1881-1893
    • Tanter, M.1
  • 9
    • 79955157179 scopus 로고    scopus 로고
    • Effect of glucose on the stress-strain behavior of ex-vivo rabbit cornea
    • S. Ni et al., Effect of glucose on the stress-strain behavior of ex-vivo rabbit cornea, Exper. Eye Res. 92(5), 353-360 (2011).
    • (2011) Exper. Eye Res. , vol.92 , Issue.5 , pp. 353-360
    • Ni, S.1
  • 12
    • 0029654138 scopus 로고
    • Magnetic resonance elastography by direct visualization of propagating acoustic strain waves
    • R. Muthupillai et al., Magnetic resonance elastography by direct visualization of propagating acoustic strain waves, Science 269(5232), 1854-1857 (1995).
    • (1995) Science , vol.269 , Issue.5232 , pp. 1854-1857
    • Muthupillai, R.1
  • 13
    • 0032619353 scopus 로고    scopus 로고
    • Elastography: Ultrasonic estimation and imaging of the elastic properties of tissues
    • Professional Engineering Publishing
    • J. Ophir et al., Elastography: Ultrasonic estimation and imaging of the elastic properties of tissues, Proc. Institution of Mechanical Engineers-Part H-J. Eng. Med. (Professional Engineering Publishing), 213(3), 203-233 (1999).
    • (1999) Proc. Institution of Mechanical Engineers-Part H-J. Eng. Med. , vol.213 , Issue.3 , pp. 203-233
    • Ophir, J.1
  • 14
    • 0027055621 scopus 로고
    • Sonoelasticity of organs: Shear waves ring a bell
    • K. J. Parker and R. M. Lerner, Sonoelasticity of organs: Shear waves ring a bell, J. Ultrasound Med. 11(8), 387-392 (1992). (Pubitemid 23049742)
    • (1992) Journal of Ultrasound in Medicine , vol.11 , Issue.8 , pp. 387-392
    • Parker, K.J.1    Lerner, R.M.2
  • 15
    • 77954715997 scopus 로고    scopus 로고
    • Tissue quantification with acoustic radiation force impulse imaging: Measurement repeatability and normal values in the healthy liver
    • M. DOnofrio, A. Gallotti, and R. P. Mucelli, Tissue quantification with acoustic radiation force impulse imaging: Measurement repeatability and normal values in the healthy liver, Am. J. Roentgenol. 195(1), 132-136 (2010).
    • (2010) Am. J. Roentgenol. , vol.195 , Issue.1 , pp. 132-136
    • Donofrio, M.1    Gallotti, A.2    Mucelli, R.P.3
  • 16
    • 80055108610 scopus 로고    scopus 로고
    • Acoustic radiation force impulse (ARFI) imaging: A review
    • K. Nightingale, Acoustic radiation force impulse (ARFI) imaging: A review, Curr. Med. Imaging Rev. 7(4), 328-339 (2011).
    • (2011) Curr. Med. Imaging Rev. , vol.7 , Issue.4 , pp. 328-339
    • Nightingale, K.1
  • 17
    • 2442466831 scopus 로고    scopus 로고
    • Supersonic shear imaging: A new technique for soft tissue elasticity mapping
    • J. Bercoff, M. Tanter, and M. Fink, Supersonic shear imaging: A new technique for soft tissue elasticity mapping, IEEE Trans. Ultrason. Ferroelectr. Freq. Control 51(4), 396-409 (2004).
    • (2004) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.51 , Issue.4 , pp. 396-409
    • Bercoff, J.1    Tanter, M.2    Fink, M.3
  • 18
    • 50049134335 scopus 로고    scopus 로고
    • Quantitative assessment of breast lesion viscoelasticity: Initial clinical results using supersonic shear imaging
    • M. Tanter et al., Quantitative assessment of breast lesion viscoelasticity: Initial clinical results using supersonic shear imaging, Ultrasound Med. Biol. 34(9), 1373-1386 (2008).
    • (2008) Ultrasound Med. Biol. , vol.34 , Issue.9 , pp. 1373-1386
    • Tanter, M.1
  • 19
    • 13844317411 scopus 로고    scopus 로고
    • Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
    • DOI 10.1016/j.jcrs.2004.10.044
    • D. A. Luce, Determining in vivo biomechanical properties of the cornea with an ocular response analyzer, J. Cataract Refractive Surg. 31(1), 156-162 (2005). (Pubitemid 40260703)
    • (2005) Journal of Cataract and Refractive Surgery , vol.31 , Issue.1 , pp. 156-162
    • Luce, D.A.1
  • 20
    • 0033021344 scopus 로고    scopus 로고
    • Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo
    • DOI 10.1006/bulm.1999.0102
    • G. J. Orssengo and D. C. Pye, Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo, Bull. Math. Biol. 61(3), 551-572 (1999). (Pubitemid 29274620)
    • (1999) Bulletin of Mathematical Biology , vol.61 , Issue.3 , pp. 551-572
    • Orssengo, G.J.1    Pye, D.C.2
  • 21
    • 77953259797 scopus 로고    scopus 로고
    • Biomechanical properties of keratoconus suspect eyes
    • A. Saad et al., Biomechanical properties of keratoconus suspect eyes, Invest. Ophthalmol. Visual Sci. 51(6), 2912-2916 (2010).
    • (2010) Invest. Ophthalmol. Visual Sci. , vol.51 , Issue.6 , pp. 2912-2916
    • Saad, A.1
  • 22
    • 0010749679 scopus 로고    scopus 로고
    • OCT elastography: Imaging microscopic deformation andstrain of tissue
    • J. Schmitt, OCT elastography: Imaging microscopic deformation andstrain of tissue, Opt. Express 3(6), 199-211 (1998).
    • (1998) Opt. Express , vol.3 , Issue.6 , pp. 199-211
    • Schmitt, J.1
  • 23
    • 79960530748 scopus 로고    scopus 로고
    • Assessment of corneal dynamics with highspeed swept source Optical Coherence Tomography combined with an air puff system
    • D. Alonso-Caneiro et al., Assessment of corneal dynamics with highspeed swept source Optical Coherence Tomography combined with an air puff system, Opt. Express 19(15), 14188-14199 (2011).
    • (2011) Opt. Express , vol.19 , Issue.15 , pp. 14188-14199
    • Alonso-Caneiro, D.1
  • 24
    • 72449204617 scopus 로고    scopus 로고
    • In vivo dynamic optical coherence elastography using a ring actuator
    • B. F. Kennedy et al., In vivo dynamic optical coherence elastography using a ring actuator, Opt. Express 17(24), 21762-21772 (2009).
    • (2009) Opt. Express , vol.17 , Issue.24 , pp. 21762-21772
    • Kennedy, B.F.1
  • 25
    • 77953840418 scopus 로고    scopus 로고
    • Dynamic spectral-domain optical coherence elastography for tissue characterization
    • X. Liang et al., Dynamic spectral-domain optical coherence elastography for tissue characterization, Opt. Express 18(13), 14183-14190 (2010).
    • (2010) Opt. Express , vol.18 , Issue.13 , pp. 14183-14190
    • Liang, X.1
  • 26
    • 47849093881 scopus 로고    scopus 로고
    • Optical micro-scale mapping of dynamic biomechanical tissue properties
    • X. Liang et al., Optical micro-scale mapping of dynamic biomechanical tissue properties, Opt. Express 16(15), 11052-11065 (2008).
    • (2008) Opt. Express , vol.16 , Issue.15 , pp. 11052-11065
    • Liang, X.1
  • 27
    • 33750350270 scopus 로고    scopus 로고
    • Double-shot depth-resolved displacement field measurement using phase-contrast spectral optical coherence tomography
    • M. H. De La Torre-Ibarra, P. D. Ruiz, and J. M. Huntley, Double-shot depth-resolved displacement field measurement using phase-contrast spectral optical coherence tomography, Opt. Express 14(21), 9643-9656 (2006).
    • (2006) Opt. Express , vol.14 , Issue.21 , pp. 9643-9656
    • De La Torre-Ibarra, M.H.1    Ruiz, P.D.2    Huntley, J.M.3
  • 28
    • 84862110237 scopus 로고    scopus 로고
    • Noncontact all-optical measurement of corneal elasticity
    • C. Li et al., Noncontact all-optical measurement of corneal elasticity, Opt. Lett. 37(10), 1625-1627 (2012).
    • (2012) Opt. Lett. , vol.37 , Issue.10 , pp. 1625-1627
    • Li, C.1
  • 29
    • 79955977212 scopus 로고    scopus 로고
    • Method for optical coherence elastography of the cornea
    • M. R. Ford et al., Method for optical coherence elastography of the cornea, J. Biomed. Opt. 16(1), 016005-016007 (2011).
    • (2011) J. Biomed. Opt. , vol.16 , Issue.1 , pp. 016005-016007
    • Ford, M.R.1
  • 30
    • 84868642615 scopus 로고    scopus 로고
    • Estimation of shear wave velocity in gelatin phantoms utilizing PhS-SSOCT
    • R. K. Manapuram et al., Estimation of shear wave velocity in gelatin phantoms utilizing PhS-SSOCT, Laser Phys. 22(9), 1439-1444 (2012).
    • (2012) Laser Phys. , vol.22 , Issue.9 , pp. 1439-1444
    • Manapuram, R.K.1
  • 31
    • 78751681224 scopus 로고    scopus 로고
    • Assessment of wave propagation on surfaces of crystalline lens with phase sensitive optical coherence tomography
    • R. K. Manapuram et al., Assessment of wave propagation on surfaces of crystalline lens with phase sensitive optical coherence tomography, Laser Phys. Lett. 8(2), 164-168 (2011).
    • (2011) Laser Phys. Lett. , vol.8 , Issue.2 , pp. 164-168
    • Manapuram, R.K.1
  • 32
    • 51849143798 scopus 로고    scopus 로고
    • Development of phasestabilized swept-source OCT for the ultrasensitive quantification of microbubbles
    • R. Manapuram, V. Manne, and K. Larin, Development of phasestabilized swept-source OCT for the ultrasensitive quantification of microbubbles, Laser Phys. 18(9), 1080-1086 (2008).
    • (2008) Laser Phys. , vol.18 , Issue.9 , pp. 1080-1086
    • Manapuram, R.1    Manne, V.2    Larin, K.3
  • 33
    • 66549084467 scopus 로고    scopus 로고
    • Phase-sensitive swept source optical coherence tomography for imaging and quantifying of microbubbles in clear and scattering media
    • R. K. Manapuram, V. G. R. Manne, and K. V. Larin, Phase-sensitive swept source optical coherence tomography for imaging and quantifying of microbubbles in clear and scattering media, J. Appl. Phys. 105(10), 102040 (2009).
    • (2009) J. Appl. Phys. , vol.105 , Issue.10 , pp. 102040
    • Manapuram, R.K.1    Manne, V.G.R.2    Larin, K.V.3
  • 34
    • 79953154435 scopus 로고    scopus 로고
    • 3D assessment of mechanical wave propagation in the crystalline eye lens using PhS-SSOCT
    • R. K. Manapuram et al., 3D assessment of mechanical wave propagation in the crystalline eye lens using PhS-SSOCT, Proc. SPIE 7885, 78851V (2011).
    • (2011) Proc. SPIE 7885 , pp. 78851
    • Manapuram, R.K.1
  • 35