메뉴 건너뛰기




Volumn 14, Issue 6, 2012, Pages 896-904

A Double-Blind Randomized Controlled Trial (RCT) of Titanium-13Zirconium versus Titanium Grade IV Small-Diameter Bone Level Implants in Edentulous Mandibles - Results from a 1-Year Observation Period

Author keywords

Alloy; Bone level implant; Double blind; Edentulous mandible; Locator; RCT; Titanium; Zirconium

Indexed keywords

TITANIUM; TOOTH IMPLANT; ZIRCONIUM;

EID: 84870513533     PISSN: 15230899     EISSN: 17088208     Source Type: Journal    
DOI: 10.1111/j.1708-8208.2010.00324.x     Document Type: Article
Times cited : (111)

References (38)
  • 1
    • 0019663098 scopus 로고
    • A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
    • Adell R, Lekholm U, Rockler B, Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981; 10:387-416.
    • (1981) Int J Oral Surg , vol.10 , pp. 387-416
    • Adell, R.1    Lekholm, U.2    Rockler, B.3    Branemark, P.I.4
  • 3
    • 0024087257 scopus 로고
    • Trends in the prevalence and severity of periodontal diseases in the US: a public health problem?
    • Capilouto ML, Douglass CW. Trends in the prevalence and severity of periodontal diseases in the US: a public health problem? J Public Health Dent 1988; 48:245-251.
    • (1988) J Public Health Dent , vol.48 , pp. 245-251
    • Capilouto, M.L.1    Douglass, C.W.2
  • 4
    • 0017564248 scopus 로고
    • Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period
    • Branemark PI, Hansson BO, Adell R, etal. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg Suppl 1977; 16:1-132.
    • (1977) Scand J Plast Reconstr Surg Suppl , vol.16 , pp. 1-132
    • Branemark, P.I.1    Hansson, B.O.2    Adell, R.3
  • 5
    • 0016980179 scopus 로고
    • [Tissue reaction to an implant of a titanium hollow cylinder with a titanium surface spray layer]
    • Schroeder A, Pohler O, Sutter F. [Tissue reaction to an implant of a titanium hollow cylinder with a titanium surface spray layer]. SSO Schweiz Monatsschr Zahnheilkd 1976; 86:713-727.
    • (1976) SSO Schweiz Monatsschr Zahnheilkd , vol.86 , pp. 713-727
    • Schroeder, A.1    Pohler, O.2    Sutter, F.3
  • 6
    • 29644434850 scopus 로고    scopus 로고
    • Oral health of individuals aged 3-80 years in Jonkoping, Sweden during 30 years (1973-2003). II. Review of clinical and radiographic findings
    • Hugoson A, Koch G, Gothberg C, etal. Oral health of individuals aged 3-80 years in Jonkoping, Sweden during 30 years (1973-2003). II. Review of clinical and radiographic findings. Swed Dent J 2005; 29:139-155.
    • (2005) Swed Dent J , vol.29 , pp. 139-155
    • Hugoson, A.1    Koch, G.2    Gothberg, C.3
  • 7
    • 34250646999 scopus 로고    scopus 로고
    • What are the prevalence and incidence of tooth loss in the adult and elderly population in Europe?
    • Muller F, Naharro M, Carlsson GE. What are the prevalence and incidence of tooth loss in the adult and elderly population in Europe? Clin Oral Implants Res 2007; 18(Suppl 3):2-14.
    • (2007) Clin Oral Implants Res , vol.18 , Issue.3 SUPPL. , pp. 2-14
    • Muller, F.1    Naharro, M.2    Carlsson, G.E.3
  • 10
    • 0030144715 scopus 로고    scopus 로고
    • A 5-year prospective multicenter follow-up report on overdentures supported by osseointegrated implants
    • Jemt T, Chai J, Harnett J, etal. A 5-year prospective multicenter follow-up report on overdentures supported by osseointegrated implants. Int J Oral Maxillofac Implants 1996; 11:291-298.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 291-298
    • Jemt, T.1    Chai, J.2    Harnett, J.3
  • 12
    • 0031203252 scopus 로고    scopus 로고
    • Patient satisfaction with implant-supported mandibular overdentures. A comparison of three treatment strategies with ITI-dental implants
    • Wismeijer D, van Waas MA, Vermeeren JI, Mulder J, Kalk W. Patient satisfaction with implant-supported mandibular overdentures. A comparison of three treatment strategies with ITI-dental implants. Int J Oral Maxillofac Surg 1997; 26:263-267.
    • (1997) Int J Oral Maxillofac Surg , vol.26 , pp. 263-267
    • Wismeijer, D.1    van Waas, M.A.2    Vermeeren, J.I.3    Mulder, J.4    Kalk, W.5
  • 13
    • 0036654483 scopus 로고    scopus 로고
    • The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients
    • Feine JS, Carlsson GE, Awad MA, etal. The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Gerodontology 2002; 19:3-4.
    • (2002) Gerodontology , vol.19 , pp. 3-4
    • Feine, J.S.1    Carlsson, G.E.2    Awad, M.A.3
  • 14
    • 69249159504 scopus 로고    scopus 로고
    • Mandibular two implant-supported overdentures as the first choice standard of care for edentulous patients - the York Consensus Statement
    • Thomason JM, Feine J, Exley C, etal. Mandibular two implant-supported overdentures as the first choice standard of care for edentulous patients - the York Consensus Statement. Br Dent J 2009; 207:185-186.
    • (2009) Br Dent J , vol.207 , pp. 185-186
    • Thomason, J.M.1    Feine, J.2    Exley, C.3
  • 15
    • 29044438918 scopus 로고    scopus 로고
    • Improved biocompatibility of Titanium-Zirconium (Ti-Zr) Alloy: tissue reaction and sensitization to Ti-Zr Alloy compared with pure Ti and Zr in rat implantation study
    • Ikarashi Y, Toyoda K, Kobayashi E, etal. Improved biocompatibility of Titanium-Zirconium (Ti-Zr) Alloy: tissue reaction and sensitization to Ti-Zr Alloy compared with pure Ti and Zr in rat implantation study. Mater Trans 2005; 46:2260-2267.
    • (2005) Mater Trans , vol.46 , pp. 2260-2267
    • Ikarashi, Y.1    Toyoda, K.2    Kobayashi, E.3
  • 16
    • 0029347568 scopus 로고
    • Mechanical properties of the binary titanium-zirconium alloys and their potential for biomedical materials
    • Kobayashi E, Matsumoto S, Doi H, Yoneyama T, Hamanaka H. Mechanical properties of the binary titanium-zirconium alloys and their potential for biomedical materials. J Biomed Mater Res 1995; 29:943-950.
    • (1995) J Biomed Mater Res , vol.29 , pp. 943-950
    • Kobayashi, E.1    Matsumoto, S.2    Doi, H.3    Yoneyama, T.4    Hamanaka, H.5
  • 17
    • 0031804625 scopus 로고    scopus 로고
    • Chondrogenic cellular responses to titanium and zirconium alloys in vitro
    • Tsuchiya T, Nakamura A, Ohshima Y, etal. Chondrogenic cellular responses to titanium and zirconium alloys in vitro. Tissue Eng 1998; 4:197-204.
    • (1998) Tissue Eng , vol.4 , pp. 197-204
    • Tsuchiya, T.1    Nakamura, A.2    Ohshima, Y.3
  • 19
    • 84870552686 scopus 로고    scopus 로고
    • Evaluation of a new Titanium-Zirconium implant: a biomedical and histological comparative study in minipigs. (OS-5) Academy of Osseointregration 23rd Annual Meeting, Boston, USA.
    • Gottlow J, Dard M, Kjellson F, Obrecht M, Sennerby I. Evaluation of a new Titanium-Zirconium implant: a biomedical and histological comparative study in minipigs. (OS-5) Academy of Osseointregration 23rd Annual Meeting, Boston, USA. 2008.
    • (2008)
    • Gottlow, J.1    Dard, M.2    Kjellson, F.3    Obrecht, M.4    Sennerby, I.5
  • 20
    • 0032082470 scopus 로고    scopus 로고
    • Use of radiographs in evaluating success, stability and failure in implant dentistry
    • Bragger U. Use of radiographs in evaluating success, stability and failure in implant dentistry. Periodontol 2000 1998; 17:77-88.
    • (1998) Periodontol 2000 , vol.17 , pp. 77-88
    • Bragger, U.1
  • 21
    • 12144271242 scopus 로고    scopus 로고
    • Patterns of tissue remodeling after placement of ITI dental implants using an osteotome technique: a longitudinal radiographic case cohort study
    • Bragger U, Gerber C, Joss A, etal. Patterns of tissue remodeling after placement of ITI dental implants using an osteotome technique: a longitudinal radiographic case cohort study. Clin Oral Implants Res 2004; 15:158-166.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 158-166
    • Bragger, U.1    Gerber, C.2    Joss, A.3
  • 22
    • 0025622922 scopus 로고
    • Tissue integration of non-submerged implants. 1-year results of a prospective study with 100 ITI hollow-cylinder and hollow-screw implants
    • Buser D, Weber HP, Lang NP. Tissue integration of non-submerged implants. 1-year results of a prospective study with 100 ITI hollow-cylinder and hollow-screw implants. Clin Oral Implants Res 1990; 1:33-40.
    • (1990) Clin Oral Implants Res , vol.1 , pp. 33-40
    • Buser, D.1    Weber, H.P.2    Lang, N.P.3
  • 23
    • 0023583441 scopus 로고
    • The microbiota associated with successful or failing osseointegrated titanium implants
    • Mombelli A, van Oosten MA, Schurch E Jr, Land NP. The microbiota associated with successful or failing osseointegrated titanium implants. Oral Microbiol Immunol 1987; 2:145-151.
    • (1987) Oral Microbiol Immunol , vol.2 , pp. 145-151
    • Mombelli, A.1    van Oosten, M.A.2    Schurch Jr., E.3    Land, N.P.4
  • 25
    • 4143063995 scopus 로고    scopus 로고
    • Enhanced bone apposition to a chemically modified SLA titanium surface
    • Buser D, Broggini N, Wieland M, etal. Enhanced bone apposition to a chemically modified SLA titanium surface. J Dent Res 2004; 83:529-533.
    • (2004) J Dent Res , vol.83 , pp. 529-533
    • Buser, D.1    Broggini, N.2    Wieland, M.3
  • 26
    • 3042524205 scopus 로고    scopus 로고
    • Implant-supported fixed prostheses in the edentulous maxilla. A 2-year clinical and radiological follow-up of treatment with non-submerged ITI implants
    • Bergkvist G, Sahlholm S, Nilner K, Lindh C. Implant-supported fixed prostheses in the edentulous maxilla. A 2-year clinical and radiological follow-up of treatment with non-submerged ITI implants. Clin Oral Implants Res 2004; 15:351-359.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 351-359
    • Bergkvist, G.1    Sahlholm, S.2    Nilner, K.3    Lindh, C.4
  • 27
    • 0035463298 scopus 로고    scopus 로고
    • A prospective study of treatment of severely resorbed maxillae with narrow nonsubmerged implants: results after 1 year of loading
    • Hallman M. A prospective study of treatment of severely resorbed maxillae with narrow nonsubmerged implants: results after 1 year of loading. Int J Oral Maxillofac Implants 2001; 16:731-736.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 731-736
    • Hallman, M.1
  • 28
    • 33644857753 scopus 로고    scopus 로고
    • Clinical and radiographic evaluation of small-diameter (3.3-mm) implants followed for 1-7 years: a longitudinal study
    • Romeo E, Lops D, Amorfini L, Chiapasco M, Ghisolfi M, Vogel G. Clinical and radiographic evaluation of small-diameter (3.3-mm) implants followed for 1-7 years: a longitudinal study. Clin Oral Implants Res 2006; 17:139-148.
    • (2006) Clin Oral Implants Res , vol.17 , pp. 139-148
    • Romeo, E.1    Lops, D.2    Amorfini, L.3    Chiapasco, M.4    Ghisolfi, M.5    Vogel, G.6
  • 29
    • 33645064549 scopus 로고    scopus 로고
    • Prosthetic treatment of maxillary lateral incisor agenesis with osseointegrated implants: a 24-39-month prospective clinical study
    • Zarone F, Sorrentino R, Vaccaro F, Russo S. Prosthetic treatment of maxillary lateral incisor agenesis with osseointegrated implants: a 24-39-month prospective clinical study. Clin Oral Implants Res 2006; 17:94-101.
    • (2006) Clin Oral Implants Res , vol.17 , pp. 94-101
    • Zarone, F.1    Sorrentino, R.2    Vaccaro, F.3    Russo, S.4
  • 30
    • 43149113226 scopus 로고    scopus 로고
    • Success rates of microimplants in edentulous patients with residual ridge resorption
    • Morneburg TR, Proschel PA. Success rates of microimplants in edentulous patients with residual ridge resorption. Int J Oral Maxillofac Implants 2008; 23:270-276.
    • (2008) Int J Oral Maxillofac Implants , vol.23 , pp. 270-276
    • Morneburg, T.R.1    Proschel, P.A.2
  • 31
    • 33644834962 scopus 로고    scopus 로고
    • Multi-clinic evaluation using mini-dental implants for long-term denture stabilization: a preliminary biometric evaluation
    • Bulard RA, Vance JB. Multi-clinic evaluation using mini-dental implants for long-term denture stabilization: a preliminary biometric evaluation. Compend Contin Educ Dent 2005; 26:892-897.
    • (2005) Compend Contin Educ Dent , vol.26 , pp. 892-897
    • Bulard, R.A.1    Vance, J.B.2
  • 33
    • 33645112784 scopus 로고    scopus 로고
    • Nine- to fourteen-year follow-up of implant treatment. Part I: implant loss and associations to various factors
    • Roos-Jansaker AM, Lindahl C, Renvert H, Renvert S. Nine- to fourteen-year follow-up of implant treatment. Part I: implant loss and associations to various factors. J Clin Periodontol 2006; 33:283-289.
    • (2006) J Clin Periodontol , vol.33 , pp. 283-289
    • Roos-Jansaker, A.M.1    Lindahl, C.2    Renvert, H.3    Renvert, S.4
  • 34
    • 37849006816 scopus 로고    scopus 로고
    • Early loading of sandblasted and acid-etched implants: a randomized-controlled double-blind split-mouth study. Five-year results
    • Roccuzzo M, Aglietta M, Bunino M, Bonino L. Early loading of sandblasted and acid-etched implants: a randomized-controlled double-blind split-mouth study. Five-year results. Clin Oral Implants Res 2008; 19:148-152.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 148-152
    • Roccuzzo, M.1    Aglietta, M.2    Bunino, M.3    Bonino, L.4
  • 35
    • 0034208063 scopus 로고    scopus 로고
    • A prospective split-mouth comparative study of two screw-shaped self-tapping pure titanium implant systems
    • van Steenberghe D, De Mars G, Quirynen M, Jacobs R, Naert I. A prospective split-mouth comparative study of two screw-shaped self-tapping pure titanium implant systems. Clin Oral Implants Res 2000; 11:202-209.
    • (2000) Clin Oral Implants Res , vol.11 , pp. 202-209
    • van Steenberghe, D.1    De Mars, G.2    Quirynen, M.3    Jacobs, R.4    Naert, I.5
  • 36
    • 0031243162 scopus 로고    scopus 로고
    • Some clinical and radiographical features of submerged and non-submerged titanium implants. A 5-year follow-up study
    • Ericsson I, Randow K, Nilner K, Petersson A. Some clinical and radiographical features of submerged and non-submerged titanium implants. A 5-year follow-up study. Clin Oral Implants Res 1997; 8:422-426.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 422-426
    • Ericsson, I.1    Randow, K.2    Nilner, K.3    Petersson, A.4
  • 37
    • 0036985577 scopus 로고    scopus 로고
    • Nonsubmerged and submerged implants in the treatment of the partially edentulous maxilla
    • Astrand P, Engquist B, Anzen B, etal. Nonsubmerged and submerged implants in the treatment of the partially edentulous maxilla. Clin Implant Dent Relat Res 2002; 4:115-127.
    • (2002) Clin Implant Dent Relat Res , vol.4 , pp. 115-127
    • Astrand, P.1    Engquist, B.2    Anzen, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.