메뉴 건너뛰기




Volumn 59, Issue 12, 2012, Pages 3304-3313

Clinical microwave tomographic imaging of the calcaneus: A first-in-human case study of two subjects

Author keywords

Bone; bone density; dielectric properties; fracture risk; microwave imaging; osteoporosis

Indexed keywords

BONE DENSITY; DENSITY MEASURES; FRACTURE RISKS; GOOD CORRELATIONS; LOWER LEG; MICROWAVE IMAGES; MICROWAVE IMAGING; MICROWAVE PROPERTY; OSTEOPOROSIS; REGULARIZATION TECHNIQUE; TOMOGRAPHIC IMAGES; TOMOGRAPHIC IMAGING; X-RAY DENSITY;

EID: 84870495964     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/TBME.2012.2209202     Document Type: Article
Times cited : (110)

References (74)
  • 2
    • 77950643657 scopus 로고
    • Looking beyond bone mineral density\imaging assessment of bone quality
    • J. F. Griffith, K. Engelke, and H. K. Genant, "Looking beyond bone mineral density\imaging assessment of bone quality, " Ann. N. Y. Acad. Sci., vol. 1192, pp. 45-56, 2010.
    • (1192) Ann. N. Y. Acad. Sci. , pp. 45-56
    • Griffith, J.F.1    Engelke, K.2    Genant, H.K.3
  • 3
    • 0030969095 scopus 로고    scopus 로고
    • Comparisons of noninvasive bone mineral measurements in assessing age- related loss, fracture discrimination, and diagnostic classification
    • S. Grampp, H. K. Genant, A. Mathur, P. Lang, M. Jergas, M. Takada, C. C. Gluer, Y. Lu, and M. Chavez, "Comparison of noninvasive bone mineral measurements in assessing age-related loss, fracture discrimination, and diagnostic classification, " J. Bone Miner. Res., vol. 12, pp. 697-711, 1997. (Pubitemid 27200321)
    • (1997) Journal of Bone and Mineral Research , vol.12 , Issue.5 , pp. 697-711
    • Grampp, S.1    Genant, H.K.2    Mathur, A.3    Lang, P.4    Jergas, M.5    Takada, M.6    Gluer, C.-C.7    Lu, Y.8    Chavez, M.9
  • 4
    • 27444437924 scopus 로고    scopus 로고
    • Rate of forearm bone loss is associated with an increased risk of fracture independently of bone mass in postmenopausal women: The OFELY study
    • DOI 10.1359/JBMR.050704
    • E. Sornay-Rendu, F. Munoz, F. Duboeuf, and P. Delmas, "Rate of forearm bone loss is associated with an increased risk of fracture independently of bone mass in postmenopausal women: The OFELY study, " J. Bone Miner. Res., vol. 20, pp. 1929-1935, 2005. (Pubitemid 41532778)
    • (2005) Journal of Bone and Mineral Research , vol.20 , Issue.11 , pp. 1929-1935
    • Sornay-Rendu, E.1    Munoz, F.2    Duboeuf, F.3    Delmas, P.D.4
  • 5
    • 0037042498 scopus 로고    scopus 로고
    • Treatment of postmenopausal osteoporosis
    • DOI 10.1016/S0140-6736(02)08827-X
    • P. D. Delmas, "Treatment of postmenopausal osteoporosis, " Lancet, vol. 359, pp. 2018-2026, 2002. (Pubitemid 34663722)
    • (2002) Lancet , vol.359 , Issue.9322 , pp. 2018-2026
    • Delmas, P.D.1
  • 6
    • 0037129560 scopus 로고    scopus 로고
    • Epidemiology and outcomes of osteoporotic fractures
    • S. R. Cummings and L. J. Melton III, "Epidemiology and outcomes of osteoporotic fractures, " Lancet, vol. 359, pp. 1761-1767, 2002.
    • (2002) Lancet , vol.359 , pp. 1761-1767
    • Cummings, S.R.1    Melton Iii, L.J.2
  • 7
    • 0000379714 scopus 로고    scopus 로고
    • Magnitude and impact of osteoporosis and fractures
    • R. Marcus, D. Feldman, and J. Kelsey, Eds., 2nd ed. San Diego, CA: Academic
    • L. J. Melton III and C. Cooper, "Magnitude and impact of osteoporosis and fractures, " in Osteoporosis, vol. 1, R. Marcus, D. Feldman, and J. Kelsey, Eds., 2nd ed. San Diego, CA: Academic, 2001, pp. 557-567.
    • (2001) Osteoporosis , vol.1 , pp. 557-567
    • Melton Iii, L.J.1    Cooper, C.2
  • 8
    • 0033550968 scopus 로고    scopus 로고
    • Mortality after all major types of osteoporotic fracture in men and women: An observational study
    • DOI 10.1016/S0140-6736(98)09075-8
    • J. R. Center, T. V. Nguyen, D. Scheider, P. N. Sambrook, and J. A. Eisman, "Mortality after all major typesofosteoporotic fractureinmen and women: An observational study, " Lancet, vol. 353, pp. 878-882, 1999. (Pubitemid 29126875)
    • (1999) Lancet , vol.353 , Issue.9156 , pp. 878-882
    • Center, J.R.1    Nguyen, T.V.2    Schneider, D.3    Sambrook, P.N.4    Eisman, J.A.5
  • 10
    • 0030035978 scopus 로고    scopus 로고
    • Mortality following fractures in older women: The study of osteoporotic fractures
    • W. S. Browner, A. R. Pressman, M. C. Nevitt, and S. R. Cummings, "Mortality following fractures in older women: The study of osteoporotic fractures, " Arch. Internal Med., vol. 156, pp. 1521-1525, 1996.
    • (1996) Arch. Internal Med. , vol.156 , pp. 1521-1525
    • Browner, W.S.1    Pressman, A.R.2    Nevitt, M.C.3    Cummings, S.R.4
  • 12
    • 0034106143 scopus 로고    scopus 로고
    • Excess mortality following vertebral fracture
    • L. J. Melton III, "Excess mortality following vertebral fracture, " J. Amer. Geriatr. Soc., vol. 48, pp. 338-339, 2000.
    • (2000) J. Amer. Geriatr. Soc. , vol.48 , pp. 338-339
    • Melton Iii, L.J.1
  • 13
    • 0009354424 scopus 로고    scopus 로고
    • Osteoporosis and its nonskeletal consequences: Their impact on treatment decisions
    • R. Marcus, D. Feldman, and J. Kelsey, Eds., 2nd ed. San Diego, CA: Academic
    • D. T. Gold, K. W. Lyles, K. M. Shipp, and M. K. Drezner, "Osteoporosis and its nonskeletal consequences: Their impact on treatment decisions, " in Osteoporosis, R. Marcus, D. Feldman, and J. Kelsey, Eds., 2nd ed. San Diego, CA: Academic, 2001, pp. 479-484.
    • (2001) Osteoporosis , pp. 479-484
    • Gold, D.T.1    Lyles, K.W.2    Shipp, K.M.3    Drezner, M.K.4
  • 14
    • 0009352141 scopus 로고    scopus 로고
    • Outcomes of osteoporotic fractures
    • R. Marcus, D. Feldman, and J. Kelsey, Eds., 2nd ed. San Diego, CA: Academic
    • G. A. Greendale and E. Barrett-Connor, "Outcomes of osteoporotic fractures, " in Osteoporosis, R. Marcus, D. Feldman, and J. Kelsey, Eds., 2nd ed. San Diego, CA: Academic, 2001, pp. 819-829.
    • (2001) Osteoporosis , pp. 819-829
    • Greendale, G.A.1    Barrett-Connor, E.2
  • 15
    • 1942420382 scopus 로고    scopus 로고
    • Comparison of radiographic texture analysis from computed radiography and bone densitometry systems
    • DOI 10.1118/1.1650529
    • J. R. Wilkie, M. L. Giger, M. R. Chinander, T. J. Vokes, H. Li, L. Dixon, and V. Jaros, "Comparison of radiographic texture analysis from computed radiography and bone densitometry systems, " Med. Phys., vol. 31, pp. 882-891, 2004. (Pubitemid 38508869)
    • (2004) Medical Physics , vol.31 , Issue.4 , pp. 882-891
    • Wilkie, J.R.1    Giger, M.L.2    Chinander, M.R.3    Vokes, T.J.4    Li, H.5    Dixon, L.6    Jaros, V.7
  • 17
    • 0035077994 scopus 로고    scopus 로고
    • Is quantitative ultrasound dependent on bone structure? A reflection
    • DOI 10.1007/s001980170151
    • C. F. Njeh, T. Fuerst, E. Diessel, and H. K. Genant, "Is quantitative ultrasound dependent on bone structure? A reflection, " Osteoporos. Int., vol. 12, pp. 1-15, 2001. (Pubitemid 32233653)
    • (2001) Osteoporosis International , vol.12 , Issue.1 , pp. 1-15
    • Njeh, C.F.1    Fuerst, T.2    Diessel, E.3    Genant, H.K.4
  • 18
    • 0030934837 scopus 로고    scopus 로고
    • Broadband ultrasound attenuation predicts fractures strongly and independently of densitometry in older women
    • D. C. Bauer, C. C. Gluer, J. A. Cauley, T. M. Vogt, K. E. Ensrud, H. K. Genant, and D. M. Black, "Broadband ultrasound attenuation predicts fractures strongly and independently of densitometry in older women, " Arch. Internal Med., vol. 157, pp. 629-633, 1997.
    • (1997) Arch. Internal Med. , vol.157 , pp. 629-633
    • Bauer, D.C.1    Gluer, C.C.2    Cauley, J.A.3    Vogt, T.M.4    Ensrud, K.E.5    Genant, H.K.6    Black, D.M.7
  • 19
    • 2642622570 scopus 로고    scopus 로고
    • Ultrasound characterization of bone demineralization
    • DOI 10.1007/s002239900406
    • C. Wu, C. Gluer, Y. Lu, T. Fuerst, D. Hans, and H. K. Genant, "Ultrasound characterization of bone demineralization, " Calcified Tissue Int., vol. 62, pp. 133-139, 1998. (Pubitemid 28086343)
    • (1998) Calcified Tissue International , vol.62 , Issue.2 , pp. 133-139
    • Wu, C.1    Gluer, C.2    Lu, Y.3    Fuerst, T.4    Hans, D.5    Genant, H.K.6
  • 20
    • 16044362010 scopus 로고    scopus 로고
    • Ulrasonographic heel measurements to predict hip fracture in elderly women: The EPIDOS prospective study
    • DOI 10.1016/S0140-6736(95)11456-4
    • D. Hans, P. Dargent-Molina, A. M. Schott, J. L. Sebert, C. Cormier, P. O. Kotzki, P. D. Delmas, J. M. Pouilles, G. Breart, and P. J. Meunier, "Ultrasonographic heel measurements to predict hip fracture in elderly women: The EPIDOS prospective study, " Lancet, vol. 348, pp. 511-514, 1996. (Pubitemid 26279013)
    • (1996) Lancet , vol.348 , Issue.9026 , pp. 511-514
    • Hans, D.1    Dargent-Molina, P.2    Schott, A.M.3    Sebert, J.L.4    Cormier, C.5    Kotzki, P.O.6    Delmas, P.D.7    Pouilles, J.M.8    Breart, G.9    Meunier, P.J.10
  • 23
    • 0042806033 scopus 로고    scopus 로고
    • Time-domain ultra-wideband imaging radar experiment for verifying super-resolution in nonlinear inverse scattering
    • F. C. Chen and W. C. Chew, "Time-domain ultra-wideband imaging radar experiment for verifying super-resolution in nonlinear inverse scattering, " J. Electromagn. Waves Appl., vol. 17, pp. 1243-1260, 2003.
    • (2003) J. Electromagn. Waves Appl. , vol.17 , pp. 1243-1260
    • Chen, F.C.1    Chew, W.C.2
  • 24
    • 0036646750 scopus 로고    scopus 로고
    • Imaging of biomedical data using a multiplicative regularized contrast source inversion method
    • DOI 10.1109/TMTT.2002.800427, PII 1011092002800427
    • A.Abubakar, P. M. van den Berg, and J. J. Mallorqui, " Imagingofbiomed-ical data using a multiplicative regularized contrast source inversion method, " IEEE Trans. Microw. Theory Tech., vol. 50, no. 7, pp. 1761-1771, Jul. 2002. (Pubitemid 34822220)
    • (2002) IEEE Transactions on Microwave Theory and Techniques , vol.50 , Issue.7 , pp. 1761-1771
    • Abubakar, A.1    Van Den Berg, P.M.2    Mallorqui, J.J.3
  • 25
    • 33846376862 scopus 로고    scopus 로고
    • Initial clinical experience with microwave breast imaging in women with normal mammography
    • DOI 10.1016/j.acra.2006.10.016, PII S1076633206006301
    • P. M. Meaney, M. W. Fanning, T. Raynolds, C. J. Fox, Q. Fang, C. A. Kogel, S. P. Poplack, and K. D. Paulsen, "Initial clinical experience with microwave breast imaging in women with normal mammography, " Acad. Radiol., vol. 14, pp. 207-218, 2007. (Pubitemid 46127650)
    • (2007) Academic Radiology , vol.14 , Issue.2 , pp. 207-218
    • Meaney, P.M.1    Fanning, M.W.2    Raynolds, T.3    Fox, C.J.4    Fang, Q.5    Kogel, C.A.6    Poplack, S.P.7    Paulsen, K.D.8
  • 26
    • 0026384343 scopus 로고
    • Inverse scattering: An iterative numerical method for electromagnetic imaging
    • Dec
    • N. Joachimowicz, C. Pichot, and J. R. Hugonin, "Inverse scattering: an iterative numerical method for electromagnetic imaging, " IEEE Trans. Antennas Propag., vol. 39, no. 12, pp. 1742-1752, Dec. 1991.
    • (1991) IEEE Trans. Antennas Propag. , vol.39 , Issue.12 , pp. 1742-1752
    • Joachimowicz, N.1    Pichot, C.2    Hugonin, J.R.3
  • 27
    • 0028428016 scopus 로고
    • Redundant electromagnetic data for microwave imaging ofthree-dimensional dielectric objects
    • May
    • S. Caorsi, G. L. Gragnani, and M. Pastorino, "Redundant electromagnetic data for microwave imaging ofthree-dimensional dielectric objects, " IEEE Trans. Antennas Propag., vol. 42, no. 5, pp. 581-589, May 1994.
    • (1994) IEEE Trans. Antennas Propag. , vol.42 , Issue.5 , pp. 581-589
    • Caorsi, S.1    Gragnani, G.L.2    Pastorino, M.3
  • 28
    • 0035391524 scopus 로고    scopus 로고
    • On the local minima in a tomographic imaging technique
    • DOI 10.1109/36.934091, PII S0196289201054730
    • T. Isernia, V. Pascazio, and R. Pierri, "On the local minima in a tomo-graphic imaging technique, " IEEE Trans. Geosci. Remote Sens. E, vol. 39, no. 7, pp. 1596-1607, Jul. 2001. (Pubitemid 32732673)
    • (2001) IEEE Transactions on Geoscience and Remote Sensing , vol.39 , Issue.7 , pp. 1596-1607
    • Isernia, T.1    Pascazio, V.2    Pierri, R.3
  • 31
    • 2942511377 scopus 로고    scopus 로고
    • Reconstruction algorithms for electromagnetic imaging
    • Jun
    • M. Pastorino, S. Caorsi, A. Massa, and A. Randazzo, "Reconstruction algorithms for electromagnetic imaging, " IEEE Trans. Instrum. Meas., vol. 53, no. 3, pp. 692-699, Jun. 2004.
    • (2004) IEEE Trans. Instrum. Meas. , vol.53 , Issue.3 , pp. 692-699
    • Pastorino, M.1    Caorsi, S.2    Massa, A.3    Randazzo, A.4
  • 34
    • 0037360011 scopus 로고    scopus 로고
    • Experimental feasibility study of confocal microwave imaging for breast tumor detection
    • Mar
    • E. C. Fear, J. Sill, and M. A. Stuchly, "Experimental feasibility study of confocal microwave imaging for breast tumor detection, " IEEE Trans. Microw. Theory Tech., vol. 51, no. 3, pp. 887-892, Mar. 2003.
    • (2003) IEEE Trans. Microw. Theory Tech. , vol.51 , Issue.3 , pp. 887-892
    • Fear, E.C.1    Sill, J.2    Stuchly, M.A.3
  • 35
    • 0032403014 scopus 로고    scopus 로고
    • Two-dimensional FDTD analysis of a pulsed microwave confocal system for breast cancer detection: Fixed-focus and antenna-array sensors
    • PII S001892949808848X
    • S. C. Hagness, A. Taflove, and J. E. Bridges, "Two-dimensional FDTD analysis of a pulsed microwave confocal system for breast cancer detection: Fixed-focus and antenna-array sensors, " IEEE Trans. Biomed. Eng., vol. 45, no. 12, pp. 1470-1479, Dec. 1998. (Pubitemid 128751994)
    • (1998) IEEE Transactions on Biomedical Engineering , vol.45 , Issue.12 , pp. 1470-1479
    • Hagness, S.C.1    Taflove, A.2    Bridges, J.E.3
  • 37
    • 0024572263 scopus 로고
    • Dielectric properties of tissues and biological materials: A critical review
    • K. R. Foster and H. Schwan, "Dielectric properties of tissues and biological materials: A critical review, " Crit. Rev. Biomed. Eng., vol. 17, no. 1, pp. 25-104, 1989.
    • (1989) Crit. Rev. Biomed. Eng. , vol.17 , Issue.1 , pp. 25-104
    • Foster, K.R.1    Schwan, H.2
  • 38
  • 39
    • 0034982640 scopus 로고    scopus 로고
    • Changes in the dielectric properties of rat tissue as a function of age at microwave frequencies
    • DOI 10.1088/0031-9155/46/6/303, PII S0031915501216881
    • A. Peyman, A. A. Rezazadeh, and C. Gabriel, "Changes in the dielectric properties of rat tissue as a function of age at microwave frequencies, " Phys. Med. Biol., vol. 46, pp. 1617-1629, 2001. (Pubitemid 32519743)
    • (2001) Physics in Medicine and Biology , vol.46 , Issue.6 , pp. 1617-1629
    • Peyman, A.1    Rezazadeh, A.A.2    Gabriel, C.3
  • 40
    • 58149265180 scopus 로고    scopus 로고
    • Variation of the dielectric properties of tissues with age: The effect on the values of SAR in children when exposed to walkie-talkie devices
    • A. Peyman, C. Gabriel, E. H. Grant, G. Vermeeren, and L. Martens, "Variation of the dielectric properties of tissues with age: The effect on the values of SAR in children when exposed to walkie-talkie devices, " Phys. Med. Biol., vol. 54, pp. 227-241, 2009.
    • (2009) Phys. Med. Biol. , vol.54 , pp. 227-241
    • Peyman, A.1    Gabriel, C.2    Grant, E.H.3    Vermeeren, G.4    Martens, L.5
  • 42
    • 0014103489 scopus 로고
    • Dielectric determination of bound water of bone
    • A. A. Marino, R. O. Becker, and C. H. Bachman, "Dielectric determination of bound water of bone, " Phys. Med. Biol., vol. 12, pp. 367-378, 1967.
    • (1967) Phys. Med. Biol. , vol.12 , pp. 367-378
    • Marino, A.A.1    Becker, R.O.2    Bachman, C.H.3
  • 43
    • 0029103233 scopus 로고
    • Comparison of the electrical and dielectric behavior of wet human cortical and cancellous bone tissue from the distal tibia
    • S. Saha and P. A. Williams, "Comparison of the electrical and dielectric behavior of wet human cortical and cancellous bone tissue from the distal tibia, " J. Orthop. Res., vol. 13, pp. 524-532, 1995.
    • (1995) J. Orthop. Res. , vol.13 , pp. 524-532
    • Saha, S.1    Williams, P.A.2
  • 44
    • 84861039416 scopus 로고    scopus 로고
    • Bone dielectric property variation as a function of mineralization at microwave frequencies
    • P. M. Meaney, T. Zhou, A. Golnabi, E. Attardo, and K. D. Paulsen, "Bone dielectric property variation as a function of mineralization at microwave frequencies, " Int. J. Biomed. Imaging, vol. 2012, pp. 649612-1-649612-9, 2012.
    • (2012) Int. J. Biomed. Imaging , pp. 649612-649611
    • Meaney, P.M.1    Zhou, T.2    Golnabi, A.3    Attardo, E.4    Paulsen, K.D.5
  • 46
    • 0022362929 scopus 로고
    • Dielectric properties of low-water-content tissues
    • S. R. Smith and K. R. Foster, "Dielectric properties of low-water-content tissues, " Phys. Med. Biol., vol. 30, pp. 965-973, 1985. (Pubitemid 15232104)
    • (1985) Physics in Medicine and Biology , vol.30 , Issue.9 , pp. 965-973
    • Smith, S.R.1    Foster, K.R.2
  • 47
    • 0015331413 scopus 로고
    • Electrical properties of bone as a function of age, immobilization and vibration
    • G. T. Swanson and J. F. Lafferty, "Electrical properties of bone as a function of age, immobilization and vibration, " J. Biomech., vol. 5, pp. 261-266, 1972.
    • (1972) J. Biomech. , vol.5 , pp. 261-266
    • Swanson, G.T.1    Lafferty, J.F.2
  • 48
    • 0032722287 scopus 로고    scopus 로고
    • Changes in bone mass and bone turnover following ankle fracture
    • B. M. Ingle, S. M. Hay, H. M. Bottjer, and R. Eastell, "Changes in bone mass and bone turnover following ankle fracture, " Osteoporos. Int., vol. 10, pp. 408-415, 1999.
    • (1999) Osteoporos. Int. , vol.10 , pp. 408-415
    • Ingle, B.M.1    Hay, S.M.2    Bottjer, H.M.3    Eastell, R.4
  • 50
    • 0023945936 scopus 로고
    • Bone mineral content in the cal-caneus after ankle fracture
    • T. Ahl, H.-E. Sjoberg, and N. Dalen, "Bone mineral content in the cal-caneus after ankle fracture, " Acta Orthop. Scand., vol. 59, pp. 173-175, 1988.
    • (1988) Acta Orthop. Scand. , vol.59 , pp. 173-175
    • Ahl, T.1    Sjoberg, H.-E.2    Dalen, N.3
  • 51
    • 80052278378 scopus 로고    scopus 로고
    • Wise-2005: Bed-rest induced changes in bone mineral density in women during 60 days simulated microgravity
    • G. Beller, D. L. Belavy, L. Sun, G. Armbrecht, C. Alexandre, and D. Felsenberg, "Wise-2005: Bed-rest induced changes in bone mineral density in women during 60 days simulated microgravity, " Bone, vol. 49, pp. 858-866, 2011.
    • (2011) Bone , vol.49 , pp. 858-866
    • Beller, G.1    Belavy, D.L.2    Sun, L.3    Armbrecht, G.4    Alexandre, C.5    Felsenberg, D.6
  • 53
    • 80051877823 scopus 로고    scopus 로고
    • Comparison of no-prior and soft-prior regularization in biomedical microwave imaging
    • A. H. Golnabi, P. M. Meaney, and K. D. Paulsen, "Comparison of no-prior and soft-prior regularization in biomedical microwave imaging, " Int. J. Med. Phys., vol. 36, no. 2, pp. 125-136, 2011.
    • (2011) Int. J. Med. Phys. , vol.36 , Issue.2 , pp. 125-136
    • Golnabi, A.H.1    Meaney, P.M.2    Paulsen, K.D.3
  • 55
    • 84908625179 scopus 로고    scopus 로고
    • Characterization of a monopole antenna in a lossy medium for microwave breast computed tomography
    • T. S. Ibrahim, S. Crozier, and E. Fear, Eds., Cairo, Egypt: Hindawi Publishing Corporation
    • C. J. Fox, P. M. Meaney, F. Shubitidze, L. Potwin, and K. D. Paulsen, "Characterization of a monopole antenna in a lossy medium for microwave breast computed tomography, " New Electromagnetic Methods and Applications of Antennas in Biomedicine, vol. 2008, T. S. Ibrahim, S. Crozier, and E. Fear, Eds., Cairo, Egypt: Hindawi Publishing Corporation, 2008.
    • (2008) New Electromagnetic Methods and Applications of Antennas in Biomedicine 2008
    • Fox, C.J.1    Meaney, P.M.2    Shubitidze, F.3    Potwin, L.4    Paulsen, K.D.5
  • 56
    • 0035241671 scopus 로고    scopus 로고
    • Microwave image reconstruction utilizing log-magnitude and unwrapped phase to improve high-contrast object recovery
    • DOI 10.1109/42.913177, PII S0278006201012320
    • P. M. Meaney, K. D. Paulsen, B. W. Pogue, and M. I. Miga, "Microwave image reconstruction utilizing log-magnitude and unwrapped phase to improve high-contrast object recovery, " IEEE Trans. Med. Imaging, vol. 20, no. 2, pp. 104-116, Feb. 2001. (Pubitemid 32407032)
    • (2001) IEEE Transactions on Medical Imaging , vol.20 , Issue.2 , pp. 104-116
    • Meaney, P.M.1    Paulsen, K.D.2    Pogue, B.W.3    Miga, M.I.4
  • 57
    • 0033237789 scopus 로고    scopus 로고
    • Compensation for nonactive array element effects in a microwave imaging system\I: Forward solution vs. Measured data comparison
    • Jun
    • K. D. Paulsen and P. M. Meaney, "Compensation for nonactive array element effects in a microwave imaging system\I: Forward solution vs. Measured data comparison, " IEEE Trans. Med. Imaging, vol. 18, no. 6, pp. 496-507, Jun. 1999.
    • (1999) IEEE Trans. Med. Imaging , vol.18 , Issue.6 , pp. 496-507
    • Paulsen, K.D.1    Meaney, P.M.2
  • 58
    • 0033237788 scopus 로고    scopus 로고
    • Nonactive antenna compensation for fixed-array microwave imaging: Part II - imaging results
    • DOI 10.1109/42.781016
    • P. M. Meaney, K. D. Paulsen, J. T. Chang, and M. Fanning, "Compensation for nonactive array element effects in a microwave imaging system\II: Imaging results, " IEEE Trans. Med. Imaging, vol. 18, no. 6, pp. 508-518, Jun. 1999. (Pubitemid 30507529)
    • (1999) IEEE Transactions on Medical Imaging , vol.18 , Issue.6 , pp. 508-518
    • Meaney, P.M.1    Paulsen, K.D.2    Chang, J.T.3    Fanning, M.W.4    Hartov, A.5
  • 60
    • 33747614794 scopus 로고    scopus 로고
    • Singular value analysis of the Jacobian matrix in microwave image reconstruction
    • DOI 10.1109/TAP.2006.879192
    • Q. Fang, P. M. Meaney, and K. D. Paulsen, "Singular value analysis of the Jacobian matrix in microwave image reconstructions, " IEEE Trans. Antennas Propag., vol. 54, no. 8, pp. 2371-2380, Aug. 2006. (Pubitemid 44263793)
    • (2006) IEEE Transactions on Antennas and Propagation , vol.54 , Issue.8 , pp. 2371-2380
    • Fang, Q.1    Meaney, P.M.2    Paulsen, K.D.3
  • 62
    • 0024891256 scopus 로고
    • Recent European developments in active microwave imaging for industrial, scientific and medical applications
    • Dec
    • J.-C. Bolomey, "Recent European developments in active microwave imaging for industrial, scientific and medical applications, " IEEE Trans. Microw. Theory Tech., vol. 37, no. 12, pp. 2109-2117, Dec. 1989.
    • (1989) IEEE Trans. Microw. Theory Tech. , vol.37 , Issue.12 , pp. 2109-2117
    • Bolomey, J.-C.1
  • 63
    • 0036074376 scopus 로고    scopus 로고
    • Confocal microwave imaging for breast cancer detection: Localization of tumors in three dimensions
    • DOI 10.1109/TBME.2002.800759
    • E. C. Fear, X. Li, S. C. Hagness, and M. A. Stuchly, "Confocal microwave imaging for breast cancer detection: Localization of tumors in three dimensions, " IEEE Trans. Biomed. Eng., vol. 49, no. 8, pp. 812-822, Aug. 2002. (Pubitemid 34787571)
    • (2002) IEEE Transactions on Biomedical Engineering , vol.49 , Issue.8 , pp. 812-822
    • Fear, E.C.1    Li, X.2    Hagness, S.C.3    Stuchly, M.A.4
  • 65
    • 34447327562 scopus 로고    scopus 로고
    • Log transformation benefits parameter estimation in microwave tomographic imaging
    • DOI 10.1118/1.2737264
    • P. M. Meaney, Q. Fang, T. Rubaek, E. Demidenko, and K. D. Paulsen, "Log transformation benefits parameter estimation in microwave tomo-graphic imaging, " Med. Phys., vol. 34, pp. 2014-2023, 2007. (Pubitemid 47055737)
    • (2007) Medical Physics , vol.34 , Issue.6 , pp. 2014-2023
    • Meaney, P.M.1    Fang, Q.2    Rubaek, T.3    Demidenko, E.4    Paulsen, K.D.5
  • 66
    • 80051874246 scopus 로고    scopus 로고
    • Importance of phase unwrapping for the reconstruction of microwave tomographic images
    • T. M. Grzegorczyk, P. M. Meaney, S. I. Jeon, S. D. Geimer, and K. D. Paulsen, "Importance of phase unwrapping for the reconstruction of microwave tomographic images, " Biomed. Opt. Exp., vol. 2, pp. 315-330, 2011.
    • (2011) Biomed. Opt. Exp. , vol.2 , pp. 315-330
    • Grzegorczyk, T.M.1    Meaney, P.M.2    Jeon, S.I.3    Geimer, S.D.4    Paulsen, K.D.5
  • 67
    • 84862847032 scopus 로고    scopus 로고
    • Assessment of inversion strategies for microwave imaging of weak magnetic scatterers embedded into a biological environment
    • Prague, Czech Republic
    • R. Scapaticci, L. Crocco, O. M. Bucci, and I. Catapano, "Assessment of inversion strategies for microwave imaging of weak magnetic scatterers embedded into a biological environment, " presented at the Eur. Conf. Antennas Propag., Prague, Czech Republic, 2012.
    • (2012) Presented at the Eur. Conf. Antennas Propag
    • Scapaticci, R.1    Crocco, L.2    Bucci, O.M.3    Catapano, I.4
  • 70
    • 76849113748 scopus 로고    scopus 로고
    • Viable three-dimensional microwave imaging: Theory and experiments
    • Feb
    • Q. Fang, P. M. Meaney, and K. D. Paulsen, "Viable three-dimensional microwave imaging: Theory and experiments, " IEEE Trans. Antennas Propag., vol. 58, no. 2, pp. 449-458, Feb. 2010.
    • (2010) IEEE Trans. Antennas Propag. , vol.58 , Issue.2 , pp. 449-458
    • Fang, Q.1    Meaney, P.M.2    Paulsen, K.D.3
  • 71
    • 0029954935 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: I. Literature survey
    • DOI 10.1088/0031-9155/41/11/001
    • C. Gabriel, S. Gabriel, and E. Corthout, "The dielectric properties of biological tissues\I: Literature survey, " Phys. Med. Biol., vol. 41, pp. 2231-2249, 1996. (Pubitemid 26376901)
    • (1996) Physics in Medicine and Biology , vol.41 , Issue.11 , pp. 2231-2249
    • Gabriel, C.1    Gabriel, S.2    Corthout, E.3
  • 72
    • 0029909341 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz
    • DOI 10.1088/0031-9155/41/11/002
    • S. Gabriel, R. W. Lau, and C. Gabriel, "The dielectric properties of biological tissues\II: Measurements in the frequency range 10 Hz to 20 GHz, " Phys. Med. Biol., vol. 41, pp. 2251-2269, 1996. (Pubitemid 26376902)
    • (1996) Physics in Medicine and Biology , vol.41 , Issue.11 , pp. 2251-2269
    • Gabriel, S.1    Lau, R.W.2    Gabriel, C.3
  • 73
    • 0029957193 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues
    • DOI 10.1088/0031-9155/41/11/003
    • S. Gabriel, R. W. Lau, and C. Gabriel, "The dielectric properties of biological tissues\III: Parametric models for the dielectric spectrum of tissues, " Phys. Med. Biol., vol. 41, pp. 2271-2293, 1996. (Pubitemid 26376903)
    • (1996) Physics in Medicine and Biology , vol.41 , Issue.11 , pp. 2271-2293
    • Gabriel, S.1    Lau, R.W.2    Gabriel, C.3
  • 74
    • 0018891104 scopus 로고
    • Microwave dielectric relaxation in muscle. A second look
    • K. R. Foster, J. L. Schepps, and H. P. Schwan, "Microwave dielectric relaxation in muscle. A second look, " Biophys. J., vol. 29, pp. 271-281, 1980. (Pubitemid 10161286)
    • (1980) Biophysical Journal , vol.29 , Issue.2 , pp. 271-281
    • Foster, K.R.1    Schepps, J.L.2    Schwan, H.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.