메뉴 건너뛰기




Volumn 12, Issue 11, 2012, Pages 1060-1066

Reducing subsidence risk by using rapid manufactured patient-specific intervertebral disc implants

Author keywords

Arthroscopy; Intervertebral disc; Medical devices; Patient specific; Rapid manufacturing

Indexed keywords

ADULT; AGED; ARTICLE; BIOMECHANICS; BONE DENSITY; BONE PLATE; BONE SCINTISCANNING; CADAVER; COMPARATIVE STUDY; EQUIPMENT DESIGN; HUMAN; HUMAN TISSUE; INTERVERTEBRAL DISK IMPLANT; KYPHOPLASTY; MALE; ORTHOPEDIC IMPLANT; PRIORITY JOURNAL; RIGIDITY; RISK REDUCTION; SPINE RADIOGRAPHY; VERTEBRA;

EID: 84870427706     PISSN: 15299430     EISSN: 18781632     Source Type: Journal    
DOI: 10.1016/j.spinee.2012.10.003     Document Type: Article
Times cited : (47)

References (23)
  • 1
    • 77950273561 scopus 로고    scopus 로고
    • The effect of implant size and device keel on vertebral compression properties in lumbar total disc replacement
    • J. Auerbach, C. Ballester, and F. Hammond The effect of implant size and device keel on vertebral compression properties in lumbar total disc replacement Spine J 10 2010 333 340
    • (2010) Spine J , vol.10 , pp. 333-340
    • Auerbach, J.1    Ballester, C.2    Hammond, F.3
  • 3
    • 15244361457 scopus 로고    scopus 로고
    • Interbody device shape and size are important to strengthen the vertebra-implant interface
    • DOI 10.1097/01.brs.0000155419.24198.35
    • J.S. Tan, C. Bailey, and M. Dvorak Interbody device shape and size are important to strengthen the vertebra-implant interface Spine 30 2005 638 644 (Pubitemid 40388646)
    • (2005) Spine , vol.30 , Issue.6 , pp. 638-644
    • Tan, J.-S.1    Bailey, C.S.2    Dvorak, M.F.3    Fisher, C.G.4    Oxland, T.R.5
  • 4
    • 14844363695 scopus 로고    scopus 로고
    • A biomechanical study of regional endplate strength and cage morphology as it relates to structural interbody support
    • DOI 10.1097/01.brs.0000143623.18098.e5
    • T. Lowe, S. Hashim, and L. Wilson A biomechanical study of regional endplate strength and cage morphology as it relates to structural interbody support Spine 29 2004 2389 2394 (Pubitemid 40353293)
    • (2004) Spine , vol.29 , Issue.21 , pp. 2389-2394
    • Lowe, T.G.1    Hashim, S.2    Wilson, L.A.3    O'Brien, M.F.4    Smith, D.A.B.5    Diekmann, M.J.6    Trommeter, J.7
  • 5
    • 0034192830 scopus 로고    scopus 로고
    • Effect of implant design and endplate preparation on the compressive strength of interbody fusion constructs
    • DOI 10.1097/00007632-200005010-00007
    • T. Steffen, A. Tsantrizos, and M. Aebi Effect of implant design and endplate preparation on the compressive strength of interbody fusion constructs Spine 25 2000 1077 1084 (Pubitemid 30317188)
    • (2000) Spine , vol.25 , Issue.9 , pp. 1077-1084
    • Steffen, T.1    Tsantrizos, A.2    Aebi, M.3
  • 6
    • 77951905201 scopus 로고    scopus 로고
    • Fusion versus disk replacement for degenerative conditions of the lumbar and cervical spine: Quid est testimonium?
    • T. Kishen, and A. Diwan Fusion versus disk replacement for degenerative conditions of the lumbar and cervical spine: quid est testimonium? Orthop Clin North Am 41 2010 167 181
    • (2010) Orthop Clin North Am , vol.41 , pp. 167-181
    • Kishen, T.1    Diwan, A.2
  • 7
    • 0041568267 scopus 로고    scopus 로고
    • Complications of artificial disc replacement - A report of 27 patients with the SB Charité disc
    • A. Van Ooij, F. Oner, and A. Verbout Complications of artificial disc replacement - a report of 27 patients with the SB Charité disc J Spinal Disord Tech 16 2003 369 383
    • (2003) J Spinal Disord Tech , vol.16 , pp. 369-383
    • Van Ooij, A.1    Oner, F.2    Verbout, A.3
  • 9
    • 34247465141 scopus 로고    scopus 로고
    • Revision and explantation strategies involving the CHARITI lumbar artificial disc replacement
    • DOI 10.1097/01.brs.0000260794.73938.93, PII 0000763220070420000013
    • S. Leary, J. Regan, T. Lanman, and W. Wagner Revision and explantation strategies involving the CHARITE lumbar artificial disc replacement Spine 32 2007 1001 1011 (Pubitemid 46646767)
    • (2007) Spine , vol.32 , Issue.9 , pp. 1001-1011
    • Leary, S.P.1    Regan, J.J.2    Lanman, T.H.3    Wagner, W.H.4
  • 10
    • 33644828313 scopus 로고    scopus 로고
    • Vertical split fracture of the vertebral body following total disc replacement using ProDisc: Report of two cases
    • DOI 10.1097/01.bsd.0000159035.35365.df, PII 0002472020051000000017
    • C. Shim, S. Lee, D. Maeng, and S.H. Lee Vertical split fracture of the vertebral body following total disc replacement using ProDisc: report of two cases J Spinal Disord Tech 18 2005 465 469 (Pubitemid 44378143)
    • (2005) Journal of Spinal Disorders and Techniques , vol.18 , Issue.5 , pp. 465-469
    • Shim, C.S.1    Lee, S.2    Maeng, D.H.3    Lee, S.-H.4
  • 11
    • 33846247425 scopus 로고    scopus 로고
    • Polyethylene wear debris and long-term clinical failure of the Charité disc prosthesis: A study of 4 patients
    • DOI 10.1097/01.brs.0000251370.56327.c6, PII 0000763220070115000013
    • A. Van Ooij, S. Kurtz, and F. Stessels Polyethylene wear debris and long-term clinical failure of the Charité disc prosthesis: a study of 4 patients Spine 32 2007 223 229 (Pubitemid 46105809)
    • (2007) Spine , vol.32 , Issue.2 , pp. 223-229
    • Van Ooij, A.1    Kurtz, S.M.2    Stessels, F.3    Noten, H.4    Van Rhijn, L.5
  • 12
    • 0029871625 scopus 로고    scopus 로고
    • Results of disc prosthesis after a minimum follow-up period of 2 years
    • DOI 10.1097/00007632-199604150-00015
    • G. Cinotti, T. David, and F. Postacchini Results of disc prosthesis after a minimum follow-up period of 2 years Spine 21 1996 995 1000 (Pubitemid 26127221)
    • (1996) Spine , vol.21 , Issue.8 , pp. 995-1000
    • Cinotti, G.1    David, T.2    Postacchini, F.3
  • 13
    • 0033024784 scopus 로고    scopus 로고
    • Artificial disc replacement with the Modular Type SB Charite III: 2- year results in 50 prospectively studied patients
    • DOI 10.1007/s005860050160
    • W. Zeegers, L.M. Bohnen, M. Laaper, and M. Verhaegen Artificial disc replacement with the modular type SB Charité III: 2-year results in 50 prospectively studied patients Eur Spine J 8 1999 210 217 (Pubitemid 29287487)
    • (1999) European Spine Journal , vol.8 , Issue.3 , pp. 210-217
    • Zeegers, W.S.1    Bohnen, L.M.L.J.2    Laaper, M.3    Verhaegen, M.J.A.4
  • 14
    • 74249111144 scopus 로고    scopus 로고
    • Geometry of the intervertebral volume and vertebral endplates of the human spine
    • E. Van der Houwen, P. Baron, and A. Veldhuizen Geometry of the intervertebral volume and vertebral endplates of the human spine Ann Biomed Eng 38 2010 33 40
    • (2010) Ann Biomed Eng , vol.38 , pp. 33-40
    • Van Der Houwen, E.1    Baron, P.2    Veldhuizen, A.3
  • 15
    • 4344618352 scopus 로고    scopus 로고
    • The use of rapid prototyping in the preoperative planning of distraction osteogenesis of the cranio-maxillofacial skeleton
    • J. Poukens, J. Haex, and D. Riediger The use of rapid prototyping in the preoperative planning of distraction osteogenesis of the cranio-maxillofacial skeleton Comput Aided Surg 8 2003 146 154
    • (2003) Comput Aided Surg , vol.8 , pp. 146-154
    • Poukens, J.1    Haex, J.2    Riediger, D.3
  • 16
    • 0038718477 scopus 로고    scopus 로고
    • Design for medical rapid prototyping of cranioplasty implants
    • L.C. Hieu, E. Bohez, and J. Vander Sloten Design for medical rapid prototyping of cranioplasty implants Rapid Prototyping J 9 2003 175 186
    • (2003) Rapid Prototyping J , vol.9 , pp. 175-186
    • Hieu, L.C.1    Bohez, E.2    Vander Sloten, J.3
  • 18
    • 53349102450 scopus 로고    scopus 로고
    • Heat treatment of Ti-6Al-7Nb components produced by selective laser melting
    • T. Sercombe, N. Jones, R. Day, and A. Kop Heat treatment of Ti-6Al-7Nb components produced by selective laser melting Rapid Prototyping J 14 2008 300 304
    • (2008) Rapid Prototyping J , vol.14 , pp. 300-304
    • Sercombe, T.1    Jones, N.2    Day, R.3    Kop, A.4
  • 19
    • 36649038367 scopus 로고    scopus 로고
    • Custom-designed orthopedic implants evaluated using finite element analysis of patient-specific computed tomography data: Femoral-component case study
    • O. Harrysson, Y. Hosni, and J. Nayfeh Custom-designed orthopedic implants evaluated using finite element analysis of patient-specific computed tomography data: femoral-component case study BMC Musculoskelet Disord 8 2007 91
    • (2007) BMC Musculoskelet Disord , vol.8 , pp. 91
    • Harrysson, O.1    Hosni, Y.2    Nayfeh, J.3
  • 20
    • 39749135426 scopus 로고    scopus 로고
    • Direct metal fabrication of titanium implants with tailored materials and mechanical properties using electron beam melting technology
    • DOI 10.1016/j.msec.2007.04.022, PII S0928493107000501
    • O. Harrysson, O. Cansizoglu, and D. Marcellin-Little Direct metal fabrication of titanium implants with tailored materials and mechanical properties using electron beam melting technology Mater Sci Eng C 28 2008 366 373 (Pubitemid 351297809)
    • (2008) Materials Science and Engineering C , vol.28 , Issue.3 , pp. 366-373
    • Harrysson, O.L.A.1    Cansizoglu, O.2    Marcellin-Little, D.J.3    Cormier, D.R.4    West II, H.A.5
  • 21
    • 34547491325 scopus 로고    scopus 로고
    • Selective laser melting of biocompatible metals for rapid manufacturing of medical parts
    • DOI 10.1108/13552540710776142
    • B. Vandenbroucke, and J.P. Kruth Selective laser melting of biocompatible metals for rapid manufacturing of medical parts Rapid Prototyping J 13 2007 196 203 (Pubitemid 47174526)
    • (2007) Rapid Prototyping Journal , vol.13 , Issue.4 , pp. 196-203
    • Vandenbroucke, B.1    Kruth, J.2
  • 22
    • 84856713507 scopus 로고    scopus 로고
    • Case report TALUS: Application of selective laser sintering technology in orthopaedics
    • R. Schindel, C. Lampert, and W. Gross Case report TALUS: application of selective laser sintering technology in orthopaedics Eur Cell Mater 10 5 Suppl 2005 TM4
    • (2005) Eur Cell Mater , vol.10 , Issue.5 SUPPL. , pp. 4
    • Schindel, R.1    Lampert, C.2    Gross, W.3
  • 23
    • 0035871207 scopus 로고    scopus 로고
    • An experimental study on the interface strength between titanium mesh cage and vertebra in reference to vertebral bone mineral density
    • DOI 10.1097/00007632-200104150-00022
    • K. Hasegawa, M. Abe, T. Washio, and T. Hara An experimental study on the interface strength between titanium mesh cage and vertebra in reference to vertebral bone mineral density Spine 26 2001 957 963 (Pubitemid 32373985)
    • (2001) Spine , vol.26 , Issue.8 , pp. 957-963
    • Hasegawa, K.1    Abe, M.2    Washio, T.3    Hara, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.