메뉴 건너뛰기




Volumn 27, Issue 4, 2012, Pages 873-884

An improved direct decoupled power control of doubly fed induction machine without rotor position sensor and with robustness to parameter variation

Author keywords

Component; direct decoupled power control (DDPC); direct power control (DPC); doubly fed induction generator (DFIG); doubly fed induction machine (DFIM); model reference adaptive system (MRAS); sensorless

Indexed keywords

COMPONENT; DIRECT DECOUPLED POWER CONTROL (DDPC); DIRECT POWER CONTROL; DOUBLY FED INDUCTION GENERATORS; DOUBLY FED INDUCTION MACHINES; MODEL REFERENCE ADAPTIVE SYSTEM; SENSORLESS;

EID: 84870302026     PISSN: 08858969     EISSN: None     Source Type: Journal    
DOI: 10.1109/TEC.2012.2209889     Document Type: Article
Times cited : (39)

References (24)
  • 1
    • 0020813083 scopus 로고
    • High response control of stator watts and vars for large wound rotor induction motor adjustable speed drives
    • Sep./Oct
    • C. B. Mayer, "High response control of stator watts and vars for large wound rotor induction motor adjustable speed drives," IEEE Trans. Ind. Appl., vol. IA-19, no. 5, pp. 736-743, Sep./Oct. 1983.
    • (1983) IEEE Trans. Ind. Appl. , vol.IA-19 , Issue.5 , pp. 736-743
    • Mayer, C.B.1
  • 2
    • 0030146394 scopus 로고    scopus 로고
    • Doubly fed induction generator using back-to-back PWM converters and its application to variablespeed wind-energy generation
    • R. Pena, J. C. Clare, and G. M. Asher, "Doubly fed induction generator using back-to-back PWM converter and is application to variable-speed wind-energy generation," Proc. IEE B-Electr. Power Appl., vol. 143, no. 3, pp. 231-241, May 1996. (Pubitemid 126760209)
    • (1996) IEE Proceedings: Electric Power Applications , vol.143 , Issue.3 , pp. 231-241
    • Pena, R.1    Clare, J.C.2    Asher, G.M.3
  • 3
    • 33750595824 scopus 로고    scopus 로고
    • Dynamic modelling and robust current control of wind-turbine driven DFIG during external AC voltage dip
    • DOI 10.1631/jzus.2006.A1757
    • J. Hu and Y. He, "Dynamic modeling and robust current control of wind turbine used DFIG during AC voltage dip," J. Zhejiang Univ. Sci. A, vol. 7, no. 10, pp. 1757-1764, Oct. 2006. (Pubitemid 44678511)
    • (2006) Journal of Zhejiang University: Science , vol.7 , Issue.10 , pp. 1757-1764
    • Hu, J.-B.1    He, Y.-K.2
  • 4
    • 0036575603 scopus 로고    scopus 로고
    • Doubly fed induction generator systems for wind turbines
    • DOI 10.1109/2943.999610
    • S. Muller, M. Deicke, and R. W. De Doncker, "Doubly fed induction generator systems for wind turbines," IEEE Trans. Ind. Appl., vol. 8, no. 3, pp. 26-33, May/Jun. 2002. (Pubitemid 34630524)
    • (2002) IEEE Industry Applications Magazine , vol.8 , Issue.3 , pp. 26-33
    • Muller, S.1    Deicke, M.2    De Doncker, R.W.3
  • 5
    • 60449101280 scopus 로고    scopus 로고
    • Improved control of DFIG systems during network unbalance using PI-R current regulators
    • Feb
    • J. Hu, Y. He, L. Xu, and B. W. Williams, "Improved control of DFIG systems during network unbalance using PI-R current regulators," IEEE Trans. Ind. Electron., vol. 56, no. 2, pp. 439-451, Feb. 2009.
    • (2009) IEEE Trans. Ind. Electron , vol.56 , Issue.2 , pp. 439-451
    • Hu, J.1    He, Y.2    Xu, L.3    Williams, B.W.4
  • 6
    • 0022778662 scopus 로고
    • New quick-response and high-efficiency control strategy of an induction motor
    • I. Takahashi and T. Noguchi, "A new quick-response and high-efficiency control strategy of an induction motor," IEEE Trans. Ind. Appl., vol. IA-22, no. 5, pp. 820-827, Sep. 1986. (Pubitemid 17468606)
    • (1986) IEEE Transactions on Industry Applications , vol.IA-22 , Issue.5 , pp. 820-827
    • Takahashi Isao1    Noguchi Toshihiko2
  • 7
    • 0024088069 scopus 로고
    • Direct self-control (DSC) of inverter-fed induction machine
    • Oct
    • M. Depenbrock, "Direct self-control (DSC) of inverter-fed induction machine," IEEE Trans. Power Electron., vol. 3, no. 4, pp. 420-429, Oct. 1988.
    • (1988) IEEE Trans. Power Electron , vol.3 , Issue.4 , pp. 420-429
    • Depenbrock, M.1
  • 8
    • 4043064208 scopus 로고    scopus 로고
    • Direct torque control of PWM inverter-fed ac motors: A survey
    • Aug
    • G. S. Buja and M. P. Kazmierkowski, "Direct torque control of PWM inverter-fed ac motors: A survey," IEEE Trans. Ind. Electron., vol. 51, no. 4, pp. 744-575, Aug. 2004.
    • (2004) IEEE Trans. Ind. Electron , vol.51 , Issue.4 , pp. 744-575
    • Buja, G.S.1    Kazmierkowski, M.P.2
  • 9
    • 4043076920 scopus 로고    scopus 로고
    • Direct torque control induction machines with constant switching frequency and reduced torque ripple
    • Aug
    • N. R. N. Idris and A. H. M. Yatim, "Direct torque control induction machines with constant switching frequency and reduced torque ripple," IEEE Trans. Ind. Electron., vol. 51, no. 4, pp. 758-767, Aug. 2004.
    • (2004) IEEE Trans. Ind. Electron , vol.51 , Issue.4 , pp. 758-767
    • Idris, N.R.N.1    Yatim, A.H.M.2
  • 11
    • 0035451718 scopus 로고    scopus 로고
    • A new approach to direct torque control of induction motor drives for constant inverter switching frequency and torque ripple reduction
    • Sep
    • Y. S. Lai and J. H. Chen, "A new approach to direct torque control of induction motor drives for constant inverter switching frequency and torque ripple reduction," IEEE Trans. Energy Convers., vol. 16, no. 3, pp. 220-227, Sep. 2001.
    • (2001) IEEE Trans. Energy Convers , vol.16 , Issue.3 , pp. 220-227
    • Lai, Y.S.1    Chen, J.H.2
  • 12
    • 0035330905 scopus 로고    scopus 로고
    • Direct power control of grid-connected wound rotor induction machine without rotor position sensors
    • DOI 10.1109/63.923772, PII S0885899301040352
    • R. Datta and V. T. Ranganathan, "Direct power control of grid-connected wound rotor induction machine without rotor position sensors," IEEE Trans. Power Electron., vol. 16, no. 3, pp. 390-399, May 2001. (Pubitemid 32534596)
    • (2001) IEEE Transactions on Power Electronics , vol.16 , Issue.3 , pp. 390-399
    • Datta, R.1    Ranganathan, V.T.2
  • 13
    • 33947418456 scopus 로고    scopus 로고
    • Direct active and reactive power control of DFIG for wind energy generation
    • DOI 10.1109/TEC.2006.875472
    • L. Xu and P. Cartwright, "Direct active and reactive power control of DFIG for wind energy generation," IEEE Trans. Energy Convers., vol. 21, no. 3, pp. 750-758, Sep. 2006. (Pubitemid 46445164)
    • (2006) IEEE Transactions on Energy Conversion , vol.21 , Issue.3 , pp. 750-758
    • Xu, L.1    Cartwright, P.2
  • 14
    • 44449114106 scopus 로고    scopus 로고
    • Two-level VSC based predictive direct torque control of the doubly fed induction machine with reduced torque and flux ripples at low constant switching frequency
    • DOI 10.1109/TPEL.2008.921160
    • G. Abad,M. A. Rodriguez, and J. Poza, "Two-level VSC-based predictive torque control of the doubly fed induction machine with reduced torque and flux ripples at low constant switching frequency," IEEE Trans. Power Electron., vol. 23, no. 3, pp. 1050-1061, May 2008. (Pubitemid 351756682)
    • (2008) IEEE Transactions on Power Electronics , vol.23 , Issue.3 , pp. 1050-1061
    • Abad, G.1    Rodriguez, M.A.2    Poza, J.3
  • 15
    • 44349083740 scopus 로고    scopus 로고
    • Two-level VSC-Based predictive direct power control of the doubly fed induction machine with reduced power ripple at low constant switching frequency
    • DOI 10.1109/TEC.2007.914167
    • G. Abad,M. A. Rodriguez, and J. Poza, "Two-level VSC-based predictive direct power control of the doubly fed induction machine with reduced power ripple at low constant switching frequency," IEEE Trans. Energy Convers., vol. 23, no. 2, pp. 570-580, Jun. 2008. (Pubitemid 351728798)
    • (2008) IEEE Transactions on Energy Conversion , vol.23 , Issue.2 , pp. 570-580
    • Abad, G.1    Rodriguez, M.A.2    Poza, J.3
  • 16
    • 33947703689 scopus 로고    scopus 로고
    • Direct power control of DFIG with constant switching frequency and improved transient performance
    • DOI 10.1109/TEC.2006.889549, Special Issue on Wind Power
    • D. Zhi and L. Xu, "Direct power control of DFIG with constant switching frequency and improved transient performance," IEEE Trans. Energy Convers., vol. 22, no. 1, pp. 110-118, Mar. 2007. (Pubitemid 46487483)
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , Issue.1 , pp. 110-118
    • Zhi, D.1    Xu, L.2
  • 17
    • 57349084647 scopus 로고    scopus 로고
    • Dynamic modeling and direct power control of wind turbine driven DFIG under unbalanced network voltage conditions
    • Dec
    • J. Hu, Y. He, and L. Xu, "Dynamic modeling and direct power control of wind turbine driven DFIG under unbalanced network voltage conditions," J. Zhejiang Univ. Sci. A, vol. 9, no. 12, pp. 1731-1740, Dec. 2008.
    • (2008) J. Zhejiang Univ. Sci. A , vol.9 , Issue.12 , pp. 1731-1740
    • Hu, J.1    He, Y.2    Xu, L.3
  • 18
    • 78649942403 scopus 로고    scopus 로고
    • Direct active and reactive power regulation of DFIG using sliding-mode control approach
    • Dec.
    • J. Hu, H. Nian, B. Hu, Y. He, and Z. Q. Zhu, "Direct active and reactive power regulation of DFIG using sliding-mode control approach," IEEE Trans. Energy Convers., vol. 25, no. 4, pp. 1028-1039, Dec. 2010.
    • (2010) IEEE Trans. Energy Convers , vol.25 , Issue.4 , pp. 1028-1039
    • Hu, J.1    Nian, H.2    Hu, B.3    He, Y.4    Zhu, Z.Q.5
  • 19
    • 77249131236 scopus 로고    scopus 로고
    • Model-based predictive direct power control of doubly fed induction generators
    • Feb.
    • D. Zhi, L. Xu, and B.W.Williams, "Model-based predictive direct power control of doubly fed induction generators," IEEE Trans. Power Electron., vol. 25, no. 2, pp. 341-351, Feb. 2010.
    • (2010) IEEE Trans. Power Electron , vol.25 , Issue.2 , pp. 341-351
    • Zhi, D.1    Xu, L.2    Williams, B.W.3
  • 20
    • 77249175320 scopus 로고    scopus 로고
    • Direct power control of doubly-fed-induction-generator-based wind turbines under unbalanced grid voltage
    • Feb.
    • G. Abad,M. A. Rodriguez, G. Iwanski, and J. Poza, "Direct power control of doubly-fed-induction-generator-based wind turbines under unbalanced grid voltage," IEEE Trans. Power Electron., vol. 25, no. 2, pp. 442-452, Feb. 2010.
    • (2010) IEEE Trans. Power Electron , vol.25 , Issue.2 , pp. 442-452
    • Abad, G.1    Rodriguez, M.A.2    Iwanski, G.3    Poza, J.4
  • 21
    • 80052064490 scopus 로고    scopus 로고
    • Improved direct power control of a wind turbine driven doubly fed induction generator during transient grid voltage unbalance
    • Aug.
    • N. Heng, S. Yipeng, P. Zhou, and Y. He, "Improved direct power control of a wind turbine driven doubly fed induction generator during transient grid voltage unbalance," IEEE Trans. Energy Convers., vol. 26, no. 3, pp. 976-986, Aug. 2011.
    • (2011) IEEE Trans. Energy Convers , vol.26 , Issue.3 , pp. 976-986
    • Heng, N.1    Yipeng, S.2    Zhou, P.3    He, Y.4
  • 22
    • 77949612220 scopus 로고    scopus 로고
    • A comparison of sensorless control strategies of doubly fed induction generator
    • X. Hao, C.W. Zhang, and X. Zhang, "A comparison of sensorless control strategies of doubly fed induction generator," in Proc. Int. Conf. Energy Environ. Technol., pp. 3-6.
    • Proc. Int. Conf. Energy Environ. Technol , pp. 3-6
    • Hao, X.1    Zhang, C.W.2    Zhang, X.3
  • 24
    • 80052574446 scopus 로고    scopus 로고
    • Direct decoupled active and reactive power control of doubly fed inductionmachine without rotor position sensors and with robustness to saturation and parameter variation
    • May
    • N. Amiri, S. M. Madani, and H. Abootorabi Zarchi, "Direct decoupled active and reactive power control of doubly fed inductionmachine without rotor position sensors and with robustness to saturation and parameter variation," in Proc. Int. Electr. Mach. Drives Conf., May, 2011, pp. 747-752.
    • (2011) Proc. Int. Electr. Mach. Drives Conf. , pp. 747-752
    • Amiri, N.1    Madani, S.M.2    Abootorabi Zarchi, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.