Volumn 25, Issue 6, 2012, Pages 736-742

Robotic anesthesia: Not the realm of science fiction any more

Author keywords

closed loop system; hybrid sedation system; Kepler Intubation System; magellan; McSleepy; sedasys; sedation; teleanesthesia; telemedicine

Indexed keywords

ANESTHETIC AGENT; BENZODIAZEPINE; FENTANYL; MIDAZOLAM; OPIATE; PROPOFOL; REMIFENTANIL;

EID: 84870252725     PISSN: 09527907     EISSN: 14736500     Source Type: Journal    
DOI: 10.1097/ACO.0b013e328359aa9f     Document Type: Review
Times cited : (19)

References (26)
  • 2
    • 34250622876 scopus 로고    scopus 로고
    • Closed-loop anaesthesia delivery system (CLADS™) using bispectral index: A performance assessment study
    • Puri GD, Kumar B, Aveek J. Closed-loop anaesthesia delivery system (CLADS) using bispectral index: a performance assessment study. Anaesth Intensive Care 2007; 35:357-362. (Pubitemid 46938789)
    • (2007) Anaesthesia and Intensive Care , vol.35 , Issue.3 , pp. 357-362
    • Puri, G.D.1    Kumar, B.2    Aveek, J.3
  • 3
    • 33645642661 scopus 로고    scopus 로고
    • Titration of propofol for anesthetic induction and maintenance guided by the bispectral index: Closed-loop versus manual control-A prospective, randomized, multicenter study
    • Liu N, Chazot T, Genty A, et al. Titration of propofol for anesthetic induction and maintenance guided by the bispectral index: closed-loop versus manual control-a prospective, randomized, multicenter study. Anesthesiology 2006; 104:686-695.
    • (2006) Anesthesiology , vol.104 , pp. 686-695
    • Liu, N.1    Chazot, T.2    Genty, A.3
  • 4
    • 79952445719 scopus 로고    scopus 로고
    • Closed-loop coadministration of propofol and remifentanil guided by bispectral index: A randomized multicenter study
    • Liu N, Chazot T, Hamada S, et al. Closed-loop coadministration of propofol and remifentanil guided by bispectral index: a randomized multicenter study. Anesth Analg 2011; 112:546-557.
    • (2011) Anesth Analg , vol.112 , pp. 546-557
    • Liu, N.1    Chazot, T.2    Hamada, S.3
  • 7
    • 84856447896 scopus 로고    scopus 로고
    • Feasibility of closed-loop titration of propofol and remifentanil guided by the spectral M-Entropy monitor
    • Liu N, Le Guen M, Benabbes-Lambert F, et al. Feasibility of closed-loop titration of propofol and remifentanil guided by the spectral M-Entropy monitor. Anesthesiology 2012; 116:286-295.
    • (2012) Anesthesiology , vol.116 , pp. 286-295
    • Liu, N.1    Le Guen, M.2    Benabbes-Lambert, F.3
  • 8
    • 84871293215 scopus 로고    scopus 로고
    • McSleepy: A novel completely automatic anesthesia delivery system: Performance evaluation in comparison to manual control in Abstracts of 2010 CAS Meeting
    • Hemmerling TM, Zaouter C, Tang L, et al. McSleepy: A novel completely automatic anesthesia delivery system: performance evaluation in comparison to manual control in Abstracts of 2010 CAS Meeting. Can J Anesth 2010; 57:116.
    • (2010) Can J Anesth , vol.57 , pp. 116
    • Hemmerling, T.M.1    Zaouter, C.2    Tang, L.3
  • 9
    • 70449512275 scopus 로고    scopus 로고
    • The Analgoscore: A novel score to monitor intraoperative nociception and its use for closed-loop application of remifentanil
    • Hemmerling TM, Charabati S, Salhab E, et al. The Analgoscore: a novel score to monitor intraoperative nociception and its use for closed-loop application of remifentanil. J Comput 2009; 4:311-318.
    • (2009) J Comput , vol.4 , pp. 311-318
    • Hemmerling, T.M.1    Charabati, S.2    Salhab, E.3
  • 10
    • 0036305841 scopus 로고    scopus 로고
    • Closed loop control of sedation for colonoscopy using the Bispectral Index
    • Leslie K, Absalom A, Kenny GN. Closed loop control of sedation for colonoscopy using the bispectral index. Anaesthesia 2002; 57:693-697. (Pubitemid 34732515)
    • (2002) Anaesthesia , vol.57 , Issue.7 , pp. 693-697
    • Leslie, K.1    Absalom, A.2    Kenny, G.N.C.3
  • 11
    • 79953242531 scopus 로고    scopus 로고
    • Computer-assisted personalized sedation for upper endoscopy and colonoscopy: A comparative, multicenter randomized study
    • Pambianco DJ, Vargo JJ, Pruitt RE, et al. Computer-assisted personalized sedation for upper endoscopy and colonoscopy: a comparative, multicenter randomized study. Gastrointest Endosc 2011; 73:765-772.
    • (2011) Gastrointest Endosc , vol.73 , pp. 765-772
    • Pambianco, D.J.1    Vargo, J.J.2    Pruitt, R.E.3
  • 12
    • 47549083357 scopus 로고    scopus 로고
    • An assessment of computerassisted personalized sedation: A sedation delivery system to administer propofol for gastrointestinal endoscopy
    • Pambianco DJ, Whitten CJ, Moerman A, et al. An assessment of computerassisted personalized sedation: a sedation delivery system to administer propofol for gastrointestinal endoscopy.Gastrointest Endosc 2008; 68:542-547.
    • (2008) Gastrointest Endosc , vol.68 , pp. 542-547
    • Pambianco, D.J.1    Whitten, C.J.2    Moerman, A.3
  • 13
    • 79953235641 scopus 로고    scopus 로고
    • The debate for nonanesthesiologist-administered propofol sedation in endoscopy rages on: Who will be the 'King of Prop?'
    • CoteGA. The debate for nonanesthesiologist-administered propofol sedation in endoscopy rages on: who will be the 'King of Prop?'. Gastrointest Endosc 2011; 73:773-776.
    • (2011) Gastrointest Endosc , vol.73 , pp. 773-776
    • Cote, G.A.1
  • 14
    • 80052250453 scopus 로고    scopus 로고
    • The SEDASYS System is not intended for the sedation of high-risk patients
    • Martin JF, Bridenbaugh P, Gustafson M. The SEDASYS System is not intended for the sedation of high-risk patients. Gastrointest Endosc 2011; 74:723.
    • (2011) Gastrointest Endosc , vol.74 , pp. 723
    • Martin, J.F.1    Bridenbaugh, P.2    Gustafson, M.3
  • 16
    • 77957701705 scopus 로고    scopus 로고
    • Robot-assisted airway support: A simulated case
    • Tighe PJ, Badiyan SJ, Luria I, et al. Robot-assisted airway support: a simulated case. Anesth Analg 2010; 111:929-931.
    • (2010) Anesth Analg , vol.111 , pp. 929-931
    • Tighe, P.J.1    Badiyan, S.J.2    Luria, I.3
  • 17
    • 84861393910 scopus 로고    scopus 로고
    • First robotic tracheal intubations in humans using the Kepler intubation system
    • Hemmerling TM, Taddei R, Wehbe M, et al. First robotic tracheal intubations in humans using the Kepler intubation system. Br J Anaesth 2012; 108:1011-1016.
    • (2012) Br J Anaesth , vol.108 , pp. 1011-1016
    • Hemmerling, T.M.1    Taddei, R.2    Wehbe, M.3
  • 18
    • 77956412567 scopus 로고    scopus 로고
    • Technical communication: Robot-assisted regional anesthesia-A simulated demonstration
    • Tighe PJ, Badiyan SJ, Luria I, et al. Technical communication: robot-assisted regional anesthesia-a simulated demonstration. Anesth Analg 2010; 111:813-816.
    • (2010) Anesth Analg , vol.111 , pp. 813-816
    • Tighe, P.J.1    Badiyan, S.J.2    Luria, I.3
  • 23
    • 63849269479 scopus 로고    scopus 로고
    • Telemedicine consultation and monitoring for pediatric liver transplant
    • Fiadjoe J, Gurnaney H, Muralidhar K, et al. Telemedicine consultation and monitoring for pediatric liver transplant. Anesth Analg 2009; 108:1212-1214.
    • (2009) Anesth Analg , vol.108 , pp. 1212-1214
    • Fiadjoe, J.1    Gurnaney, H.2    Muralidhar, K.3
  • 24
    • 2542426400 scopus 로고    scopus 로고
    • Preadmission anesthesia consultation using telemedicine technology: A pilot study
    • DOI 10.1097/00000542-200406000-00038
    • Wong DT, Kamming D, Salenieks ME, et al. Preadmission anesthesia consultation using telemedicine technology: a pilot study. Anesthesiology 2004; 100:1605-1607. (Pubitemid 38679334)
    • (2004) Anesthesiology , vol.100 , Issue.6 , pp. 1605-1607
    • Wong, D.T.1    Kamming, D.2    Salenieks, M.E.3    Go, K.4    Kohm, C.5    Chung, F.6