메뉴 건너뛰기




Volumn 39, Issue 7, 2012, Pages 1154-1160

PET/MR imaging of bone lesions - Implications for PET quantification from imperfect attenuation correction

Author keywords

Attenuation correction; Bone segmentation; CT simulation; MR; PET

Indexed keywords

FLUORODEOXYGLUCOSE F 18;

EID: 84862643672     PISSN: 16197070     EISSN: 16197089     Source Type: Journal    
DOI: 10.1007/s00259-012-2113-0     Document Type: Article
Times cited : (219)

References (14)
  • 1
    • 60549086399 scopus 로고    scopus 로고
    • Towards quantitative PET/MRI: A review of MR-based attenuation correction techniques
    • 10.1007/s00259-008-1007-7 19104810 10.1007/s00259-008-1007-7
    • M Hofmann B Pichler B Scholkopf T Beyer 2009 Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques Eur J Nucl Med Mol Imaging 36 Suppl 1 S93 S104 10.1007/s00259-008-1007-7 19104810 10.1007/s00259-008-1007-7
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , Issue.SUPPL. 1
    • Hofmann, M.1    Pichler, B.2    Scholkopf, B.3    Beyer, T.4
  • 2
    • 0036093165 scopus 로고    scopus 로고
    • PET attenuation coefficients from CT images: Experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients
    • 10.1007/s00259-002-0796-3 12111133 10.1007/s00259-002-0796-3 1:STN:280:DC%2BD38zms1Gjtg%3D%3D
    • C Burger G Goerres S Schoenes A Buck AH Lonn GK Von Schulthess 2002 PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients Eur J Nucl Med Mol Imaging 29 7 922 927 10.1007/s00259-002-0796-3 12111133 10.1007/s00259-002- 0796-3 1:STN:280:DC%2BD38zms1Gjtg%3D%3D
    • (2002) Eur J Nucl Med Mol Imaging , vol.29 , Issue.7 , pp. 922-927
    • Burger, C.1    Goerres, G.2    Schoenes, S.3    Buck, A.4    Lonn, A.H.5    Von Schulthess, G.K.6
  • 3
    • 43749114975 scopus 로고    scopus 로고
    • MR-based attenuation correction for torso-PET/MR imaging: Pitfalls in mapping MR to CT data
    • 10.1007/s00259-008-0734-0 18283452 10.1007/s00259-008-0734-0
    • T Beyer M Weigert HH Quick U Pietrzyk F Vogt C Palm, et al. 2008 MR-based attenuation correction for torso-PET/MR imaging: pitfalls in mapping MR to CT data Eur J Nucl Med Mol Imaging 35 6 1142 1146 10.1007/s00259-008-0734-0 18283452 10.1007/s00259-008-0734-0
    • (2008) Eur J Nucl Med Mol Imaging , vol.35 , Issue.6 , pp. 1142-1146
    • Beyer, T.1    Weigert, M.2    Quick, H.H.3    Pietrzyk, U.4    Vogt, F.5    Palm, C.6
  • 4
    • 57349155316 scopus 로고    scopus 로고
    • MRI-based attenuation correction for PET/MRI: A novel approach combining pattern recognition and atlas registration
    • 10.2967/jnumed.107.049353 18927326 10.2967/jnumed.107.049353
    • M Hofmann F Steinke V Scheel G Charpiat J Farquhar P Aschoff, et al. 2008 MRI-based attenuation correction for PET/MRI: a novel approach combining pattern recognition and atlas registration J Nucl Med 49 11 1875 1883 10.2967/jnumed.107.049353 18927326 10.2967/jnumed.107.049353
    • (2008) J Nucl Med , vol.49 , Issue.11 , pp. 1875-1883
    • Hofmann, M.1    Steinke, F.2    Scheel, V.3    Charpiat, G.4    Farquhar, J.5    Aschoff, P.6
  • 5
    • 63849338624 scopus 로고    scopus 로고
    • Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: Evaluation with PET/CT data
    • 10.2967/jnumed.108.054726 19289430 10.2967/jnumed.108.054726
    • A Martinez-Möller M Souvatzoglou G Delso RA Bundschuh C Chefd'hotel SI Ziegler, et al. 2009 Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: evaluation with PET/CT data J Nucl Med 50 4 520 526 10.2967/jnumed.108.054726 19289430 10.2967/jnumed.108.054726
    • (2009) J Nucl Med , vol.50 , Issue.4 , pp. 520-526
    • Martinez-Möller, A.1    Souvatzoglou, M.2    Delso, G.3    Bundschuh, R.A.4    Chefd'hotel, C.5    Ziegler, S.I.6
  • 6
    • 79551523276 scopus 로고    scopus 로고
    • Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data
    • 10.1007/s00259-010-1603-1 20922522 10.1007/s00259-010-1603-1 1:STN:280:DC%2BC3M%2FlsVKqtg%3D%3D
    • V Schulz I Torres-Espallardo S Renisch Z Hu N Ojha P Bornert, et al. 2011 Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data Eur J Nucl Med Mol Imaging 38 1 138 152 10.1007/s00259-010-1603-1 20922522 10.1007/s00259-010-1603-1 1:STN:280:DC%2BC3M%2FlsVKqtg%3D%3D
    • (2011) Eur J Nucl Med Mol Imaging , vol.38 , Issue.1 , pp. 138-152
    • Schulz, V.1    Torres-Espallardo, I.2    Renisch, S.3    Hu, Z.4    Ojha, N.5    Bornert, P.6
  • 7
    • 80052644918 scopus 로고    scopus 로고
    • MRI-based attenuation correction for whole-body PET/MRI: Quantitative evaluation of segmentation- and atlas-based methods
    • 10.2967/jnumed.110.078949 21828115 10.2967/jnumed.110.078949
    • M Hofmann I Bezrukov F Mantlik P Aschoff F Steinke T Beyer T, et al. 2011 MRI-based attenuation correction for whole-body PET/MRI: quantitative evaluation of segmentation- and atlas-based methods J Nucl Med 52 9 1392 1399 10.2967/jnumed.110.078949 21828115 10.2967/jnumed.110.078949
    • (2011) J Nucl Med , vol.52 , Issue.9 , pp. 1392-1399
    • Hofmann, M.1    Bezrukov, I.2    Mantlik, F.3    Aschoff, P.4    Steinke, F.5    Beyer, T.T.6
  • 8
    • 77952302436 scopus 로고    scopus 로고
    • MRI-based attenuation correction for PET/MRI using ultrashort echo time sequences
    • 10.2967/jnumed.109.065425 20439508 10.2967/jnumed.109.065425
    • V Keereman Y Fierens T Broux Y De Deene M Lonneux S Vandenberghe 2010 MRI-based attenuation correction for PET/MRI using ultrashort echo time sequences J Nucl Med 51 5 812 818 10.2967/jnumed.109.065425 20439508 10.2967/jnumed.109.065425
    • (2010) J Nucl Med , vol.51 , Issue.5 , pp. 812-818
    • Keereman, V.1    Fierens, Y.2    Broux, T.3    De Deene, Y.4    Lonneux, M.5    Vandenberghe, S.6
  • 9
    • 33751368661 scopus 로고    scopus 로고
    • Clinical ultrashort echo time imaging of bone and other connective tissues
    • 10.1002/nbm.1100 17075960 10.1002/nbm.1100
    • MD Robson GM Bydder 2006 Clinical ultrashort echo time imaging of bone and other connective tissues NMR Biomed 19 7 765 780 10.1002/nbm.1100 17075960 10.1002/nbm.1100
    • (2006) NMR Biomed , vol.19 , Issue.7 , pp. 765-780
    • Robson, M.D.1    Bydder, G.M.2
  • 10
    • 79959535733 scopus 로고    scopus 로고
    • Repeatability of SUV measurements in serial PET
    • 21776800 10.1118/1.3578604 1:STN:280:DC%2BC3MjgtV2jsA%3D%3D
    • J Schwartz JL Humm M Gonen H Kalaigian H Schoder SM Larson, et al. 2011 Repeatability of SUV measurements in serial PET Med Phys 38 5 2629 2638 21776800 10.1118/1.3578604 1:STN:280:DC%2BC3MjgtV2jsA%3D%3D
    • (2011) Med Phys , vol.38 , Issue.5 , pp. 2629-2638
    • Schwartz, J.1    Humm, J.L.2    Gonen, M.3    Kalaigian, H.4    Schoder, H.5    Larson, S.M.6
  • 11
    • 84862631668 scopus 로고    scopus 로고
    • Repeatability of FDG quantification in tumor imaging: Averaged SUVs are superior to SUVmax
    • in press. doi:10.1016/j.nucmedbio.2011.11.002
    • Burger IA, Huser DM, Burger C, von Schulthess GK, Buck A. Repeatability of FDG quantification in tumor imaging: averaged SUVs are superior to SUVmax. Nucl Med Biol. 2012; in press. doi: 10.1016/j.nucmedbio.2011.11.002
    • (2012) Nucl Med Biol
    • Burger, I.A.1    Huser, D.M.2    Burger, C.3    Von Schulthess, G.K.4    Buck, A.5
  • 12
    • 77954244658 scopus 로고    scopus 로고
    • The effect of inaccurate bone attenuation coefficient and segmentation on reconstructed PET images
    • 10.1097/MNM.0b013e32833b0573 20505553 10.1097/MNM.0b013e32833b0573
    • PJ Schleyer T Schaeffter PK Marsden 2010 The effect of inaccurate bone attenuation coefficient and segmentation on reconstructed PET images Nucl Med Commun 31 8 708 716 10.1097/MNM.0b013e32833b0573 20505553 10.1097/MNM. 0b013e32833b0573
    • (2010) Nucl Med Commun , vol.31 , Issue.8 , pp. 708-716
    • Schleyer, P.J.1    Schaeffter, T.2    Marsden, P.K.3
  • 13
    • 80455149956 scopus 로고    scopus 로고
    • Value of a Dixon-based MR/PET attenuation correction sequence for the localization and evaluation of PET-positive lesions
    • 10.1007/s00259-011-1842-9 21688050 10.1007/s00259-011-1842-9
    • M Eiber A Martinez-Moller M Souvatzoglou K Holzapfel A Pickhard D Loffelbein, et al. 2011 Value of a Dixon-based MR/PET attenuation correction sequence for the localization and evaluation of PET-positive lesions Eur J Nucl Med Mol Imaging 38 9 1691 1701 10.1007/s00259-011-1842-9 21688050 10.1007/s00259-011-1842-9
    • (2011) Eur J Nucl Med Mol Imaging , vol.38 , Issue.9 , pp. 1691-1701
    • Eiber, M.1    Martinez-Moller, A.2    Souvatzoglou, M.3    Holzapfel, K.4    Pickhard, A.5    Loffelbein, D.6
  • 14
    • 77957038794 scopus 로고    scopus 로고
    • Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype
    • 10.2967/jnumed.109.069112 20810759 10.2967/jnumed.109.069112 1:CAS:528:DC%2BC3cXht1ejsLvI
    • C Catana A van der Kouwe T Benner CJ Michel M Hamm M Fenchel, et al. 2010 Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype J Nucl Med 51 9 1431 1438 10.2967/jnumed.109.069112 20810759 10.2967/jnumed.109.069112 1:CAS:528:DC%2BC3cXht1ejsLvI
    • (2010) J Nucl Med , vol.51 , Issue.9 , pp. 1431-1438
    • Catana, C.1    Van Der Kouwe, A.2    Benner, T.3    Michel, C.J.4    Hamm, M.5    Fenchel, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.