메뉴 건너뛰기




Volumn 26, Issue 12, 2012, Pages 693-698

Fibroregulation of mesenchymal progenitor cells by BMP-4 after traumatic muscle injury

Author keywords

fibrosis; heterotopic ossification; mesenchymal stem cells; polytrauma

Indexed keywords

BONE MORPHOGENETIC PROTEIN 4; CARTILAGE OLIGOMETRIC MATRIX PROTEIN; CD18 ANTIGEN; GROWTH DIFFERENTIATION FACTOR 10; OSTEOCALCIN; SCLEROPROTEIN; TUMOR NECROSIS FACTOR ALPHA; UNCLASSIFIED DRUG;

EID: 84870239598     PISSN: 08905339     EISSN: 15312291     Source Type: Journal    
DOI: 10.1097/BOT.0b013e3182712adf     Document Type: Article
Times cited : (26)

References (17)
  • 1
    • 0001144547 scopus 로고    scopus 로고
    • Acute compartment syndrome: Update on diagnosis and treatment
    • Whitesides TE, Heckman MM. Acute compartment syndrome: update on diagnosis and treatment. J Am Acad Orthop Surg. 1996;4:209-218.
    • (1996) J Am Acad Orthop Surg. , vol.4 , pp. 209-218
    • Whitesides, T.E.1    Heckman, M.M.2
  • 2
    • 79959265977 scopus 로고    scopus 로고
    • Compartment syndrome-induced microvascular dysfunction: An experimental rodent model
    • Lawendy AR, Sanders DW, Bihari A, et al. Compartment syndrome-induced microvascular dysfunction: an experimental rodent model. Can J Surg. 2011;54:194-200.
    • (2011) Can J Surg. , vol.54 , pp. 194-200
    • Lawendy, A.R.1    Sanders, D.W.2    Bihari, A.3
  • 3
    • 77956251707 scopus 로고    scopus 로고
    • Indomethacin reduces cell damage: Shedding new light on compartment syndrome
    • Manjoo A, Sanders D, Lawendy A, et al. Indomethacin reduces cell damage: shedding new light on compartment syndrome. J Orthop Trauma. 2010;24:526-529.
    • (2010) J Orthop Trauma. , vol.24 , pp. 526-529
    • Manjoo, A.1    Sanders, D.2    Lawendy, A.3
  • 4
    • 43349102162 scopus 로고    scopus 로고
    • Complications after fasciotomy revision and delayed compartment release in combat patients
    • discussion S61-S62
    • Ritenour AE, Dorlac WC, Fang R, et al. Complications after fasciotomy revision and delayed compartment release in combat patients. J Trauma. 2008;64:S153-S161; discussion S61-S62.
    • (2008) J Trauma. , vol.64
    • Ritenour, A.E.1    Dorlac, W.C.2    Fang, R.3
  • 5
    • 72449163588 scopus 로고    scopus 로고
    • Variation in diagnosis of compartment syndrome by surgeons treating tibial shaft fractures
    • O'Toole RV, Whitney A, Merchant N, et al. Variation in diagnosis of compartment syndrome by surgeons treating tibial shaft fractures. J Trauma. 2009;67:735-741.
    • (2009) J Trauma. , vol.67 , pp. 735-741
    • O'Toole, R.V.1    Whitney, A.2    Merchant, N.3
  • 6
    • 0028874368 scopus 로고
    • Measurement of tissue viability using intravital microscopy and fluorescent nuclear dyes
    • Potter RF, Peters G, Carson M, et al. Measurement of tissue viability using intravital microscopy and fluorescent nuclear dyes. J Surg Res. 1995;59:521-526.
    • (1995) J Surg Res. , vol.59 , pp. 521-526
    • Potter, R.F.1    Peters, G.2    Carson, M.3
  • 7
    • 79957866830 scopus 로고    scopus 로고
    • Compartment syndrome ultrafiltration catheters: Report of a clinical pilot study of a novel method for managing patients at risk of compartment syndrome
    • Odland RM, Schmidt AH. Compartment syndrome ultrafiltration catheters: report of a clinical pilot study of a novel method for managing patients at risk of compartment syndrome. J Orthop Trauma. 2011;25:358-365.
    • (2011) J Orthop Trauma. , vol.25 , pp. 358-365
    • Odland, R.M.1    Schmidt, A.H.2
  • 9
    • 14844301678 scopus 로고    scopus 로고
    • Depth profile of diffuse reflectance near-infrared spectroscopy for measurement of water content in skin
    • DOI 10.1111/j.1600-0846.2005.00093.x
    • Arimoto H, Egawa M, Yamada Y. Depth profile of diffuse reflectance near-infrared spectroscopy for measurement of water content in skin. Skin Res Technol. 2005;11:27-35. (Pubitemid 40347605)
    • (2005) Skin Research and Technology , vol.11 , Issue.1 , pp. 27-35
    • Arimoto, H.1    Egawa, M.2    Yamada, Y.3
  • 11
    • 0028569484 scopus 로고
    • Validation of near-infrared spectroscopy in humans
    • Mancini DM, Bolinger L, Li H, et al. Validation of near-infrared spectroscopy in humans. J Appl Physiol. 1994;77:2740-2747.
    • (1994) J Appl Physiol. , vol.77 , pp. 2740-2747
    • Mancini, D.M.1    Bolinger, L.2    Li, H.3
  • 12
    • 0036799674 scopus 로고    scopus 로고
    • Intramuscular and blood pressures in legs positioned in the hemilithotomy position. Clarification of risk factors for well-leg acute compartment syndrome
    • Meyer RS, White KK, Smith JM, et al. Intramuscular and blood pressures in legs positioned in the hemilithotomy position: clarification of risk factors for well-leg acute compartment syndrome. J Bone Joint Surg Am. 2002;84-A:1829-1835. (Pubitemid 35176477)
    • (2002) Journal of Bone and Joint Surgery - Series A , vol.84 , Issue.10 , pp. 1829-1835
    • Meyer, R.S.1    White, K.K.2    Smith, J.M.3    Groppo, E.R.4    Mubarak, S.J.5    Hargens, A.R.6
  • 13
    • 0032916486 scopus 로고    scopus 로고
    • Monitoring for compartmental syndrome using near-infrared spectroscopy: A noninvasive, continuous, transcutaneous monitoring technique
    • discussion 617-618
    • Garr JL, Gentilello LM, Cole PA, et al. Monitoring for compartmental syndrome using near-infrared spectroscopy: a noninvasive, continuous, transcutaneous monitoring technique. J Trauma. 1999;46:613-616; discussion 617-618.
    • (1999) J Trauma. , vol.46 , pp. 613-616
    • Garr, J.L.1    Gentilello, L.M.2    Cole, P.A.3
  • 14
    • 79952525973 scopus 로고    scopus 로고
    • The use of near-infrared spectrometry for the diagnosis of lower-extremity compartment syndrome
    • Bariteau JT, Beutel BG, Kamal R, et al. The use of near-infrared spectrometry for the diagnosis of lower-extremity compartment syndrome. Orthopedics. 2011;34:178.
    • (2011) Orthopedics. , vol.34 , pp. 178
    • Bariteau, J.T.1    Beutel, B.G.2    Kamal, R.3
  • 15
    • 77951916057 scopus 로고    scopus 로고
    • Correlation between muscle oxygenation and compartment pressures in acute compartment syndrome of the leg
    • Shuler MS, Reisman WM, Kinsey TL, et al. Correlation between muscle oxygenation and compartment pressures in acute compartment syndrome of the leg. J Bone Joint Surg Am. 2010;92:863-870.
    • (2010) J Bone Joint Surg Am. , vol.92 , pp. 863-870
    • Shuler, M.S.1    Reisman, W.M.2    Kinsey, T.L.3
  • 16
    • 80755135400 scopus 로고    scopus 로고
    • Near-infrared spectroscopy in acute compartment syndrome: Case report
    • Shuler MS, Reisman WM, Cole AL, et al. Near-infrared spectroscopy in acute compartment syndrome: case report. Injury. 2011;42:1506-1508.
    • (2011) Injury , vol.42 , pp. 1506-1508
    • Shuler, M.S.1    Reisman, W.M.2    Cole, A.L.3
  • 17
    • 77957335805 scopus 로고    scopus 로고
    • Towards a single-chip, implantable RFID system: Is a single-cell radio possible?
    • Burke P, Rutherglen C. Towards a single-chip, implantable RFID system: is a single-cell radio possible? Biomed Microdevices. 2010;12: 589-596.
    • (2010) Biomed Microdevices , vol.12 , pp. 589-596
    • Burke, P.1    Rutherglen, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.