메뉴 건너뛰기




Volumn 34, Issue 3, 2011, Pages

The use of near-infrared spectrometry for the diagnosis of lowerextremity compartment syndrome

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BLOOD PRESSURE; BLOOD PRESSURE MEASUREMENT; CLINICAL ARTICLE; CLINICAL TRIAL; COMPARTMENT SYNDROME; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; FASCIOTOMY; FEMALE; HUMAN; INFRARED SPECTROMETRY; INJURY SEVERITY; LEG DISEASE; MALE; MUSCLE EXAMINATION; OXYGEN SATURATION; PROSPECTIVE STUDY; RECEIVER OPERATING CHARACTERISTIC; SENSITIVITY AND SPECIFICITY; TISSUE OXYGENATION; ADULT; INFRARED RADIATION; LEG; METABOLISM; METHODOLOGY; NEAR INFRARED SPECTROSCOPY; REPRODUCIBILITY;

EID: 79952525973     PISSN: 01477447     EISSN: None     Source Type: Journal    
DOI: 10.3928/01477447-20110124-12     Document Type: Article
Times cited : (15)

References (20)
  • 5
    • 33644683525 scopus 로고    scopus 로고
    • Acute compartment syndrome in lower extremity musculoskeletal trauma
    • Olson SA, Glasgow RR. Acute compartment syndrome in lower extremity musculoskeletal trauma. J Am Acad Orthop Surg. 2005; 13(7):436-444.
    • (2005) J Am Acad Orthop Surg , vol.13 , Issue.7 , pp. 436-444
    • Olson, S.A.1    Glasgow, R.R.2
  • 6
    • 56149094347 scopus 로고    scopus 로고
    • Diagnostic techniques in acute compartment syndrome of the leg
    • Shadgan B, Menon M, O'Brien PJ, Reid WD. Diagnostic techniques in acute compartment syndrome of the leg. J Orthop Trauma. 2008; 22(8):581-587.
    • (2008) J Orthop Trauma , vol.22 , Issue.8 , pp. 581-587
    • Shadgan, B.1    Menon, M.2    O'Brien, P.J.3    Reid, W.D.4
  • 7
    • 0036748127 scopus 로고    scopus 로고
    • The clinical diagnosis of compartment syndrome of the lower leg: Are clinical findings predictive of the disorder?
    • DOI 10.1097/00005131-200209000-00006
    • Ulmer T. The clinical diagnosis of compartment syndrome of the lower leg: are clinical findings predictive of the disorder? J Orthop Trauma. 2002; 16(8):572-577. (Pubitemid 35153705)
    • (2002) Journal of Orthopaedic Trauma , vol.16 , Issue.8 , pp. 572-577
    • Ulmer, T.1
  • 8
    • 0030030010 scopus 로고    scopus 로고
    • Compartment monitoring in tibial fractures. The pressure threshold for decompression
    • McQueen MM, Court-Brown CM. Compartment monitoring in tibial fractures. The pressure threshold for decompression. J Bone Joint Surg Br. 1996; 78(1):99-104.
    • (1996) J Bone Joint Surg Br , vol.78 , Issue.1 , pp. 99-104
    • McQueen, M.M.1    Court-Brown, C.M.2
  • 9
    • 0043076103 scopus 로고    scopus 로고
    • Acute compartment syndrome of the lower leg: Retrospective study on prevalence, technique, and outcome of fasciotomies
    • DOI 10.1007/s00268-003-6691-7
    • Heemskerk J, Kitslaar P. Acute compartment syndrome of the lower leg: retrospective study on prevalence, technique, and outcome of fasciotomies [published online ahead of print May 13, 2003]. World J Surg. 2003; 27(6):744-747. (Pubitemid 36961111)
    • (2003) World Journal of Surgery , vol.27 , Issue.6 , pp. 744-747
    • Heemskerk, J.1    Kitslaar, P.2
  • 10
  • 11
    • 0019431054 scopus 로고
    • Compartmental pressure measurements: An experimental investigation using the slit catheter
    • Rorabeck CH, Castle GS, Hardie R, Logan J. Compartmental pressure measurements: an experimental investigation using the slit catheter. J Trauma. 1981; 21(6):446-449. (Pubitemid 11123012)
    • (1981) Journal of Trauma , vol.21 , Issue.6 , pp. 446-449
    • Rorabeck, C.H.1    Castle, G.S.P.2    Hardie, R.3    Logan, J.4
  • 12
    • 0037351366 scopus 로고    scopus 로고
    • Comparing the methods of measuring compartment pressures in acute compartment syndrome
    • DOI 10.1053/ajem.2003.50035
    • Uliasz A, Ishida JT, Fleming JK, Yamamoto LG. Comparing the methods of measuring compartment pressures in acute compartment syndrome. Am J Emerg Med. 2003; 21(2):143-145. (Pubitemid 36396827)
    • (2003) American Journal of Emergency Medicine , vol.21 , Issue.2 , pp. 143-145
    • Uliasz, A.1    Ishida, J.T.2    Fleming, J.K.3    Yamamoto, L.G.4
  • 13
    • 27544509971 scopus 로고    scopus 로고
    • Accuracy in the measurement of compartment pressures: A comparison of three commonly used devices
    • DOI 10.2106/JBJS.D.02826
    • Boody AR, Wongworawat MD. Accuracy in the measurement of compartment pressures: a comparison of three commonly used devices. J Bone Joint Surg Am. 2005; 87(11):2415-2422. (Pubitemid 41546371)
    • (2005) Journal of Bone and Joint Surgery - Series A , vol.87 , Issue.11 , pp. 2415-2422
    • Boody, A.R.1    Wongworawat, M.D.2
  • 14
    • 0033994111 scopus 로고    scopus 로고
    • Hyperbaric oxygen therapy for trauma: Crush injury, compartment syndrome, and other acute traumatic peripheral ischemias
    • Myers RA. Hyperbaric oxygen therapy for trauma: crush injury, compartment syndrome, and other acute traumatic peripheral ischemias. Int Anesthesiol Clin. 2000; 38(1):139-151. (Pubitemid 30118368)
    • (2000) International Anesthesiology Clinics , vol.38 , Issue.1 , pp. 139-151
    • Myers, R.A.M.1
  • 15
    • 0034125673 scopus 로고    scopus 로고
    • Utility of near-infrared spectroscopy in the diagnosis of lower extremity compartment syndrome
    • Giannotti G, Cohn SM, Brown M, Varela JE, McKenney MG, Wiseberg JA. Utility of near-infrared spectroscopy in the diagnosis of lower extremity compartment syndrome. J Trauma. 2000; 48(3):396-399.
    • (2000) J Trauma , vol.48 , Issue.3 , pp. 396-399
    • Giannotti, G.1    Cohn, S.M.2    Brown, M.3    Varela, J.E.4    McKenney, M.G.5    Wiseberg, J.A.6
  • 16
    • 0040331938 scopus 로고    scopus 로고
    • Near-infrared spectroscopy versus compartment pressure for the diagnosis of lower extremity compartmental syndrome using electromyography-determined measurements of neuromuscular function
    • Gentilello LM, Sanzone A, Wang L, Liu PY, Robinson L. Near-infrared spectroscopy versus compartment pressure for the diagnosis of lower extremity compartmental syndrome using electromyography-determined measurements of neuromuscular function. J Trauma. 2001; 51(1):1-8. (Pubitemid 33598877)
    • (2001) Journal of Trauma - Injury, Infection and Critical Care , vol.51 , Issue.1 , pp. 1-8
    • Gentilello, L.M.1    Sanzone, A.2    Wang, L.3    Liu, P.-Y.4    Robinson, L.5
  • 17
    • 0032733569 scopus 로고    scopus 로고
    • Near-infrared spectroscopy: A potential method for continuous, transcutaneous monitoring for compartmental syndrome in critically injured patients
    • Arbabi S, Brundage SI, Gentilello LM. Near-infrared spectroscopy: a potential method for continuous, transcutaneous monitoring for compartmental syndrome in critically injured patients. J Trauma. 1999; 47(5):829-833.
    • (1999) J Trauma , vol.47 , Issue.5 , pp. 829-833
    • Arbabi, S.1    Brundage, S.I.2    Gentilello, L.M.3
  • 19
    • 0017571334 scopus 로고
    • Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters
    • Jöbsis FF. Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. Science. 1977; 198(4323):1264-1267. (Pubitemid 8308546)
    • (1977) Science , vol.198 , Issue.4323 , pp. 1264-1267
    • Jobsis, F.F.1
  • 20
    • 0032916486 scopus 로고    scopus 로고
    • Monitoring for compartmental syndrome using near-infrared spectroscopy: A noninvasive, continuous, transcutaneous monitoring technique
    • Garr JL, Gentilello LM, Cole PA, Mock CN, Matsen FA III. Monitoring for compartmental syndrome using near-infrared spectroscopy: a noninvasive, continuous, transcutaneous monitoring technique. J Trauma. 1999; 46(4):613-616.
    • (1999) J Trauma , vol.46 , Issue.4 , pp. 613-616
    • Garr, J.L.1    Gentilello, L.M.2    Cole, P.A.3    Mock, C.N.4    Matsen III, F.A.5