메뉴 건너뛰기




Volumn 13, Issue 12, 2012, Pages 1047-1052

Usefulness of three-dimensional transthoracic echocardiography for the classification of congenital bicuspid aortic valve in children

Author keywords

Bicuspid aortic valve; Congenital heart disease; Three dimensional echocardiography

Indexed keywords

ADOLESCENT; ARTICLE; BICUSPID AORTIC VALVE; CARDIOLOGIST; CHILD; CHILDHOOD DISEASE; CONTROLLED STUDY; DISEASE CLASSIFICATION; FEMALE; HUMAN; IMAGE QUALITY; INFANT; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; PRESCHOOL CHILD; PRIORITY JOURNAL; PROSPECTIVE STUDY; SCHOOL CHILD; THREE DIMENSIONAL ECHOCARDIOGRAPHY; TRANSTHORACIC ECHOCARDIOGRAPHY; TWO DIMENSIONAL ECHOCARDIOGRAPHY;

EID: 84869487130     PISSN: 20472404     EISSN: None     Source Type: Journal    
DOI: 10.1093/ehjci/jes089     Document Type: Article
Times cited : (16)

References (34)
  • 2
    • 0034030487 scopus 로고    scopus 로고
    • Clinical significance of the bicuspid aortic valve
    • Ward C. Clinical significance of the bicuspid aortic valve. Heart 2000;83:81-5. (Pubitemid 30307645)
    • (2000) Heart , vol.83 , Issue.1 , pp. 81-85
    • Ward, C.1
  • 4
    • 0014820336 scopus 로고
    • The congenitally bicuspid aortic valve
    • Roberts WC. The congenitally bicuspid aortic valve. Am J Cardiol 1970;26:72-83.
    • (1970) Am J Cardiol , vol.26 , pp. 72-83
    • Roberts, W.C.1
  • 5
    • 0001525280 scopus 로고
    • The bicuspid condition of the aortic valve
    • Osler W. The bicuspid condition of the aortic valve. Trans Assoc Am Physicians 1886;2:185-92.
    • (1886) Trans Assoc Am Physicians , vol.2 , pp. 185-192
    • Osler, W.1
  • 8
  • 9
    • 77955985227 scopus 로고    scopus 로고
    • Outcome of isolated bicuspid aortic valve in childhood
    • Mahle WT, Sutherland JL, Frias PA. Outcome of isolated bicuspid aortic valve in childhood. J Pediatr 2010;157:445-9.
    • (2010) J Pediatr , vol.157 , pp. 445-449
    • Mahle, W.T.1    Sutherland, J.L.2    Frias, P.A.3
  • 10
    • 0032894771 scopus 로고    scopus 로고
    • Congenitally bicuspid aortic valves: A surgical pathology study of 542 cases (1991 through 1996) and a literature review of 2,715 additional cases
    • Sabet HY, Edwards WD, Tazelaar HD, Daly RC. Congenitally bicuspid aortic valves: a surgical pathology study of 542 cases (1991 through 1996) and a literature review of 2,715 additional cases. Mayo Clin Proc 1999;74:14-26. (Pubitemid 29042671)
    • (1999) Mayo Clinic Proceedings , vol.74 , Issue.1 , pp. 14-26
    • Sabet, H.Y.1    Edwards, W.D.2    Tazelaar, H.D.3    Daly, R.C.4
  • 13
    • 34247463401 scopus 로고    scopus 로고
    • A classification system for the bicuspid aortic valve from 304 surgical specimens
    • DOI 10.1016/j.jtcvs.2007.01.039, PII S0022522307002371
    • Sievers HH, Schmidtke C. A classification system for the bicuspid aortic valve from 304 surgical specimens. J Thorac Cardiovasc Surg 2007;133:1226-33. (Pubitemid 46656388)
    • (2007) Journal of Thoracic and Cardiovascular Surgery , vol.133 , Issue.5 , pp. 1226-1233
    • Sievers, H.-H.1    Schmidtke, C.2
  • 14
    • 56749159135 scopus 로고    scopus 로고
    • The bicuspid aortic valve: An integrated phenotypic classification of leaflet morphology and aortic root shape
    • Schaefer BM, Lewin MB, Stout KK, Gill E, Prueitt A, Byers PH et al. The bicuspid aortic valve: an integrated phenotypic classification of leaflet morphology and aortic root shape. Heart 2008;94:1634-8.
    • (2008) Heart , vol.94 , pp. 1634-1638
    • Schaefer, B.M.1    Lewin, M.B.2    Stout, K.K.3    Gill, E.4    Prueitt, A.5    Byers, P.H.6
  • 16
    • 0020538330 scopus 로고
    • Accuracy of 2-dimensional echocardiographic diagnosis of congenitally bicuspid aortic valve: Echocardiographic-anatomic correlation in 115 patients
    • Brandenburg RO Jr, Tajik AJ, Edwards WD, Reeder GS, Shub C, Seward JB. Accuracy of 2-dimensional echocardiographic diagnosis of congenitally bicuspid aortic valve: echocardiographic-anatomic correlation in 115 patients. Am J Cardiol 1983;51:1469-73. (Pubitemid 13086697)
    • (1983) American Journal of Cardiology , vol.51 , Issue.9 , pp. 1469-1473
    • Brandenburg Jr., R.O.1    Tajik, A.J.2    Edwards, W.D.3
  • 17
    • 77958585763 scopus 로고    scopus 로고
    • Diagnostic value of cardiac CT in the evaluation of bicuspid aortic stenosis: Comparison with echocardiography and operative findings
    • Tanaka R, Yoshioka K, Niinuma H, Ohsawa S, Okabayashi H, Ehara S. Diagnostic value of cardiac CT in the evaluation of bicuspid aortic stenosis: comparison with echocardiography and operative findings. AJR Am J Roentgenol 2010;195:895-9.
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 895-899
    • Tanaka, R.1    Yoshioka, K.2    Niinuma, H.3    Ohsawa, S.4    Okabayashi, H.5    Ehara, S.6
  • 18
    • 79955451572 scopus 로고    scopus 로고
    • Bicuspid stenotic aortic valves: Clinical characteristics and morphological assessment using MRI and echocardiography
    • Joziasse IC, Vink A, Cramer MJ, van Oosterhout MF, van Herwerden LA, Heijmen R et al. Bicuspid stenotic aortic valves: clinical characteristics and morphological assessment using MRI and echocardiography. Neth Heart J 2011;19: 119-125.
    • (2011) Neth Heart J , vol.19 , pp. 119-125
    • Joziasse, I.C.1    Vink, A.2    Cramer, M.J.3    Van Oosterhout, M.F.4    Van Herwerden, L.A.5    Heijmen, R.6
  • 19
    • 77958599517 scopus 로고    scopus 로고
    • Cardiac CT for the differentiation of bicuspid and tricuspid aortic valves: Comparison with echocardiography and surgery
    • Alkadhi H, Leschka S, Trindade PT, Feuchtner G, Stolzmann P, Plass A et al. Cardiac CT for the differentiation of bicuspid and tricuspid aortic valves: comparison with echocardiography and surgery. AJR Am J Roentgenol 2010;195:900-8.
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 900-908
    • Alkadhi, H.1    Leschka, S.2    Trindade, P.T.3    Feuchtner, G.4    Stolzmann, P.5    Plass, A.6
  • 20
    • 13244272088 scopus 로고    scopus 로고
    • Three-dimensional demonstration of bicuspid aortic valve by 16-row multidetector computed tomography: Comparison with transesophageal echocardiography
    • DOI 10.1016/j.ejcts.2004.10.056, PII S1010794004008413
    • Niinuma H, Yoshioka K, Ogino Y, Kawazoe K. Three-dimensional demonstration of bicuspid aortic valve by 16-row multidetector computed tomography: comparison with transesophageal echocardiography. Eur J Cardiothorac Surg 2005;27: 346. (Pubitemid 40193151)
    • (2005) European Journal of Cardio-thoracic Surgery , vol.27 , Issue.2 , pp. 346
    • Niinuma, H.1    Yoshioka, K.2    Ogino, Y.3    Kawazoe, K.4
  • 21
    • 77954797125 scopus 로고    scopus 로고
    • Variable phenotypes of bicuspid aortic valve disease: Classification by cardiovascular magnetic resonance
    • Buchner S, Hülsmann M, Poschenrieder F, Hamer OW, Fellner C, Kobuch R et al. Variable phenotypes of bicuspid aortic valve disease: classification by cardiovascular magnetic resonance. Heart 2010;96:1233-40.
    • (2010) Heart , vol.96 , pp. 1233-1240
    • Buchner, S.1    Hülsmann, M.2    Poschenrieder, F.3    Hamer, O.W.4    Fellner, C.5    Kobuch, R.6
  • 22
    • 63849184058 scopus 로고    scopus 로고
    • Live/real time three-dimensional transthoracic echocardiographic assessment of bicuspid aortic valve morphology
    • Singh P, Dutta R, Nanda NC. Live/real time three-dimensional transthoracic echocardiographic assessment of bicuspid aortic valve morphology. Echocardiography 2009;26:478-80.
    • (2009) Echocardiography , vol.26 , pp. 478-480
    • Singh, P.1    Dutta, R.2    Nanda, N.C.3
  • 23
    • 77950579418 scopus 로고    scopus 로고
    • Recognising bicuspid aortic stenosis in patients referred for transcatheter aortic valve implantation: Routine screening with threedimensional transoesophageal echocardiography
    • Unsworth B, Malik I, Mikhail GW. Recognising bicuspid aortic stenosis in patients referred for transcatheter aortic valve implantation: routine screening with threedimensional transoesophageal echocardiography. Heart 2010;96:645.
    • (2010) Heart , vol.96 , pp. 645
    • Unsworth, B.1    Malik, I.2    Mikhail, G.W.3
  • 25
    • 13244250042 scopus 로고    scopus 로고
    • How not to miss a bicuspid aortic valve in the echocardiography laboratory
    • DOI 10.1111/j.0742-2822.2005.04074.x
    • Tirrito SJ, Kerut EK. How not to miss a bicuspid aortic valve in the echocardiography laboratory. Echocardiography 2005;22:53-5. (Pubitemid 40193498)
    • (2005) Echocardiography , vol.22 , Issue.1 , pp. 53-55
    • Tirrito, S.J.1    Kerut, E.K.2
  • 26
    • 79251623655 scopus 로고    scopus 로고
    • Three-dimensional echocardiography in congenital heart disease
    • Simpson JM, Miller O. Three-dimensional echocardiography in congenital heart disease. Arch Cardiovasc Dis 2011;104:45-56.
    • (2011) Arch Cardiovasc Dis , vol.104 , pp. 45-56
    • Simpson, J.M.1    Miller, O.2
  • 27
    • 80955135838 scopus 로고    scopus 로고
    • Accuracy of twodimensional echocardiography in determining aortic valve structure in patients .50 years of age having aortic valve replacement for aortic stenosis
    • Ayad RF, Grayburn PA, Ko JM, Filardo G, Roberts WC. Accuracy of twodimensional echocardiography in determining aortic valve structure in patients .50 years of age having aortic valve replacement for aortic stenosis. Am J Cardiol 2011;108:1589-99.
    • (2011) Am J Cardiol , vol.108 , pp. 1589-1599
    • Ayad, R.F.1    Grayburn, P.A.2    Ko, J.M.3    Filardo, G.4    Roberts, W.C.5
  • 28
    • 77953685042 scopus 로고    scopus 로고
    • Twodimensional versus transthoracic real-time three-dimensional echocardiography in the evaluation of the mechanisms and sites of atrioventricular valve regurgitation in a congenital heart disease population
    • Takahashi K, Mackie AS, Rebeyka IM, Ross DB, Robertson M, Dyck JD et al. Twodimensional versus transthoracic real-time three-dimensional echocardiography in the evaluation of the mechanisms and sites of atrioventricular valve regurgitation in a congenital heart disease population. J Am Soc Echocardiogr 2010;23: 726-34.
    • (2010) J Am Soc Echocardiogr , vol.23 , pp. 726-734
    • Takahashi, K.1    MacKie, A.S.2    Rebeyka, I.M.3    Ross, D.B.4    Robertson, M.5    Dyck, J.D.6
  • 29
    • 4444225006 scopus 로고    scopus 로고
    • Comparison of real-time 3-dimensional echocardiography with conventional 2-dimensional echocardiography in the assessment of structural heart disease
    • DOI 10.1016/j.echo.2004.05.005, PII S089473170400495X
    • Chan KL, Liu X, Ascah KJ, Beauchesne LM, Burwash IG. Comparison of real-time 3-dimensional echocardiography with conventional 2-dimensional echocardiography in the assessment of structural heart disease. J Am Soc Echocardiogr 2004; 17:976-80. (Pubitemid 39164945)
    • (2004) Journal of the American Society of Echocardiography , vol.17 , Issue.9 , pp. 976-980
    • Chan, K.-L.1    Liu, X.2    Ascah, K.J.3    Beauchesne, L.M.4    Burwash, I.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.