메뉴 건너뛰기




Volumn 100 A, Issue 12, 2012, Pages 3189-3196

A tissue-engineered aneurysm model for evaluation of endovascular devices

Author keywords

Aneurysm modeling; Bioreactor; Endovascular technologies; In vitro testing; Tissue engineering

Indexed keywords

BIOCONVERSION; BIOREACTORS; BLOOD VESSELS; GRAFTS; SCANNING ELECTRON MICROSCOPY; TISSUE; TISSUE ENGINEERING;

EID: 84869089700     PISSN: 15493296     EISSN: 15524965     Source Type: Journal    
DOI: 10.1002/jbm.a.34256     Document Type: Article
Times cited : (7)

References (34)
  • 3
    • 77956321490 scopus 로고    scopus 로고
    • A review of clinical trials and registries in descending thoracic aortic aneurysms
    • Knepper J, Upchurch GR Jr. A review of clinical trials and registries in descending thoracic aortic aneurysms. Semin Vasc Surg 2010;23:170-175.
    • (2010) Semin Vasc Surg , vol.23 , pp. 170-175
    • Knepper, J.1    Upchurch Jr., G.R.2
  • 4
    • 10944250967 scopus 로고    scopus 로고
    • Surveillance for endoleaks: How to detect all of them
    • DOI 10.1053/j.semvascsurg.2004.09.003, PII S0895796704000638
    • Hiatt MD, Rubin GD. Surveillance for endoleaks: How to detect all of them. Semin Vasc Surg 2004;17:268-278. (Pubitemid 40018040)
    • (2004) Seminars in Vascular Surgery , vol.17 , Issue.4 SPEC. ISSUE , pp. 268-278
    • Hiatt, M.D.1    Rubin, G.D.2
  • 5
    • 0029998672 scopus 로고    scopus 로고
    • Transfemoral endovascular repair of abdominal aortic aneurysm: Results of the North American EVT phase 1 trial
    • DOI 10.1016/S0741-5214(96)80032-2
    • Moore WS, Rutherford RB. Transfemoral endovascular repair of abdominal aortic aneurysm: Results of the North American EVT phase 1 trial. EVT Investigators. J Vasc Surg 1996;23:543-553. (Pubitemid 26131810)
    • (1996) Journal of Vascular Surgery , vol.23 , Issue.4 , pp. 543-553
    • Moore, W.S.1    Rutherford, R.B.2
  • 6
    • 4143105843 scopus 로고    scopus 로고
    • Post-endograft abdominal aortic aneurysm shrinkage varies among hospitals: Observations from multicenter trials
    • DOI 10.1583/04-1241.1
    • Kritpracha B, Beebe HG, Criado FJ, Comerota AJ. Post-endograft abdominal aortic aneurysm shrinkage varies among hospitals: Observations from multicenter trials. J Endovasc Ther 2004;11:454-459. (Pubitemid 39096343)
    • (2004) Journal of Endovascular Therapy , vol.11 , Issue.4 , pp. 454-459
    • Kritpracha, B.1    Beebe, H.G.2    Criado, F.J.3    Comerota, A.J.4
  • 7
    • 0034754053 scopus 로고    scopus 로고
    • What are the causes of endotension?
    • DOI 10.1583/1545-1550(2001)008 <0454:WATCOE>2.0.CO;2
    • White GH. What are the causes of endotension? J Endovasc Ther 2001;8:454-456. (Pubitemid 33032458)
    • (2001) Journal of Endovascular Therapy , vol.8 , Issue.5 , pp. 454-456
    • White, G.H.1
  • 8
    • 34249658496 scopus 로고    scopus 로고
    • Assessing the effectiveness of endografts: Clinical and experimental perspectives
    • Lee LK, Faries PL. Assessing the effectiveness of endografts: Clinical and experimental perspectives. J Vasc Surg 2007;45(Suppl A):A123-A130.
    • (2007) J Vasc Surg , vol.45 , Issue.SUPPL. A
    • Lee, L.K.1    Faries, P.L.2
  • 9
    • 80055048127 scopus 로고    scopus 로고
    • Endovascular stent graft repair of abdominal aortic aneurysms: Current status and future directions
    • Sun Z. Endovascular stent graft repair of abdominal aortic aneurysms: Current status and future directions. World J Radiol 2009;1:63-71.
    • (2009) World J Radiol , vol.1 , pp. 63-71
    • Sun, Z.1
  • 10
    • 34547954719 scopus 로고    scopus 로고
    • Chondroitin-4-sulfate: A bioactive macromolecule to foster vascular healing around stent-grafts after endovascular aneurysm repair
    • DOI 10.1002/mabi.200700008
    • Charbonneau C, Gautrot JE, Hebert MJ, Zhu XX, Lerouge S. Chondroitin-4-sulfate: A bioactive macromolecule to foster vascular healing around stent-grafts after endovascular aneurysm repair. Macromol Biosci 2007;7:746-752. (Pubitemid 47264647)
    • (2007) Macromolecular Bioscience , vol.7 , Issue.5 , pp. 746-752
    • Charbonneau, C.1    Gautrot, J.E.2    Hebert, M.-J.3    Zhu, X.X.4    Lerouge, S.5
  • 11
    • 1642505555 scopus 로고    scopus 로고
    • Ingrowth of aorta wall into stent grafts impregnated with basic fibroblast growth factor: A porcine in vivo study of blood vessel prosthesis healing
    • DOI 10.1016/j.jvs.2003.11.045
    • van der Bas JM, Quax PH, van den Berg AC, Visser MJ, van der Linden E, van Bockel JH. Ingrowth of aorta wall into stent grafts impregnated with basic fibroblast growth factor: A porcine in vivo study of blood vessel prosthesis healing. J Vasc Surg 2004;39:850-858. (Pubitemid 38405819)
    • (2004) Journal of Vascular Surgery , vol.39 , Issue.4 , pp. 850-858
    • Van Der Bas, J.M.A.1    Quax, P.H.A.2    Van Den Berg, A.C.3    Visser, M.J.T.4    Van Der Linden, E.5    Van Bockel, J.H.6
  • 13
    • 45549108684 scopus 로고    scopus 로고
    • Role of the endothelial lining in endoleak formation and persistence after endovascular repair of aneurysm
    • Soulez G, Lerouge S, Darsaut T, Salazkin I, Oliva VL, Raymond J. Role of the endothelial lining in endoleak formation and persistence after endovascular repair of aneurysm. J Vasc Interv Radiol 2008;19:1070-1078.
    • (2008) J Vasc Interv Radiol , vol.19 , pp. 1070-1078
    • Soulez, G.1    Lerouge, S.2    Darsaut, T.3    Salazkin, I.4    Oliva, V.L.5    Raymond, J.6
  • 14
    • 80052899303 scopus 로고    scopus 로고
    • A standardized aortic aneurysm model for the assessment of endovascular stent-graft technology
    • Macierewicz JA, Albertini JN, Hinchliffe RJ. A standardized aortic aneurysm model for the assessment of endovascular stent-graft technology. Vascular 2011;19:82-88.
    • (2011) Vascular , vol.19 , pp. 82-88
    • Macierewicz, J.A.1    Albertini, J.N.2    Hinchliffe, R.J.3
  • 16
    • 45949089532 scopus 로고    scopus 로고
    • An automatic algorithm for detecting stent endothelialization from volumetric optical coherence tomography datasets
    • DOI 10.1088/0031-9155/53/12/001, PII S0031915508702434
    • Bonnema GT, Cardinal KO, Williams SK, Barton JK. An automatic algorithm for detecting stent endothelialization from volumetric optical coherence tomography datasets. Phys Med Biol 2008;53:3083-3098. (Pubitemid 351892388)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.12 , pp. 3083-3098
    • Bonnema, G.T.1    Cardinal, K.O.2    Williams, S.K.3    Barton, J.K.4
  • 17
    • 33845936216 scopus 로고    scopus 로고
    • Tissue-engineered vascular grafts as in vitro blood vessel mimics for the evaluation of endothelialization of intravascular devices
    • DOI 10.1089/ten.2006.12.3431
    • Cardinal KO, Bonnema GT, Hofer H, Barton JK, Williams SK. Tissue-engineered vascular grafts as in vitro blood vessel mimics for the evaluation of endothelialization of intravascular devices. Tissue Eng 2006;12:3431-3438. (Pubitemid 46037166)
    • (2006) Tissue Engineering , vol.12 , Issue.12 , pp. 3431-3438
    • Cardinal, K.O.1    Bonnema, G.T.2    Hofer, H.3    Barton, J.K.4    Williams, S.K.5
  • 18
    • 72049087229 scopus 로고    scopus 로고
    • Assessment of the intimal response to a protein-modified stent in a tissue-engineered blood vessel mimic
    • Cardinal KO, Williams SK. Assessment of the intimal response to a protein-modified stent in a tissue-engineered blood vessel mimic. Tissue Eng Part A 2009;15:3869-3876.
    • (2009) Tissue Eng Part A , vol.15 , pp. 3869-3876
    • Cardinal, K.O.1    Williams, S.K.2
  • 19
    • 0028316958 scopus 로고
    • Liposuction-derived human fat used for vascular graft sodding contains endothelial cells and not mesothelial cells as the major cell type
    • Williams SK, Wang TF, Castrillo R, Jarrell BE. Liposuction-derived human fat used for vascular graft sodding contains endothelial cells and not mesothelial cells as the major cell type. J Vasc Surg 1994;19:916-923. (Pubitemid 24149938)
    • (1994) Journal of Vascular Surgery , vol.19 , Issue.5 , pp. 916-923
    • Williams, S.K.1    Ti Fen Wang2    Castrillo, R.3    Jarrell, B.E.4
  • 22
    • 23344433873 scopus 로고    scopus 로고
    • Flow visualization in a model of a bifurcated stent-graft
    • DOI 10.1583/04-1465.1
    • Chong CK, How TV, Harris PL. Flow visualization in a model of a bifurcated stent-graft. J Endovasc Ther 2005;12:435-445. (Pubitemid 41105792)
    • (2005) Journal of Endovascular Therapy , vol.12 , Issue.4 , pp. 435-445
    • Chong, C.K.1    How, T.V.2    Harris, P.L.3
  • 23
    • 0242299762 scopus 로고    scopus 로고
    • Endotension as a result of pressure transmission through the graft following endovascular aneurysm repair - An in vitro study
    • DOI 10.1016/S1078-5884(03)00378-2
    • Gawenda M, Jaschke G, Winter S, Wassmer G, Brunkwall J. Endotension as a result of pressure transmission through the graft following endovascular aneurysm repair-An in vitro study. Eur J Vasc Endovasc Surg 2003;26:501-505. (Pubitemid 37362091)
    • (2003) European Journal of Vascular and Endovascular Surgery , vol.26 , Issue.5 , pp. 501-505
    • Gawenda, M.1    Jaschke, G.2    Winter, St.3    Wassmer, G.4    Brunkwall, J.5
  • 27
    • 0028371070 scopus 로고
    • Microvascular endothelial cell sodding of ePTFE vascular grafts: Improved patency and stability of the cellular lining
    • Williams SK, Rose DG, Jarrell BE. Microvascular endothelial cell sodding of ePTFE vascular grafts: Improved patency and stability of the cellular lining. J Biomed Mater Res 1994;28:203-212. (Pubitemid 24039014)
    • (1994) Journal of Biomedical Materials Research , vol.28 , Issue.2 , pp. 203-212
    • Williams, S.K.1    Rose, D.G.2    Jarrell, B.E.3
  • 29
    • 27444435668 scopus 로고    scopus 로고
    • Influence of lumen shape and vessel geometry on plaque stresses: Possible role in the increased vulnerability of a remodelled vessel and the "shoulder" of a plaque
    • DOI 10.1136/hrt.2004.049072
    • Kumar RK, Balakrishnan KR. Influence of lumen shape and vessel geometry on plaque stresses: Possible role in the increased vulnerability of a remodelled vessel and the shoulder of a plaque. Heart 2005;91:1459-1465. (Pubitemid 41531826)
    • (2005) Heart , vol.91 , Issue.11 , pp. 1459-1465
    • Kumar, R.K.1    Balakrishnan, K.R.2
  • 31
    • 0037180418 scopus 로고    scopus 로고
    • Coated stents for the prevention of restenosis: Part I
    • DOI 10.1161/01.CIR.0000038982.49640.70
    • Babapulle MN, Eisenberg MJ. Coated stents for the prevention of restenosis: Part I. Circulation 2002;106:2734-2740. (Pubitemid 35364930)
    • (2002) Circulation , vol.106 , Issue.21 , pp. 2734-2740
    • Babapulle, M.N.1    Eisenberg, M.J.2
  • 32
    • 34249310690 scopus 로고    scopus 로고
    • The effects of stenting and endothelial denudation on aneurysm and branch occlusion in experimental aneurysm models
    • DOI 10.1016/j.jvs.2007.02.060, PII S0741521407003527
    • Darsaut T, Bouzeghrane F, Salazkin I, Lerouge S, Soulez G, Gevry G, Raymond J. The effects of stenting and endothelial denudation on aneurysm and branch occlusion in experimental aneurysm models. J Vasc Surg 2007;45:1228-1235. (Pubitemid 46817855)
    • (2007) Journal of Vascular Surgery , vol.45 , Issue.6 , pp. 1228-1235
    • Darsaut, T.1    Bouzeghrane, F.2    Salazkin, I.3    Lerouge, S.4    Soulez, G.5    Gevry, G.6    Raymond, J.7
  • 34
    • 28444440656 scopus 로고    scopus 로고
    • Mechanical responses of a compliant electrospun poly(L-lactide-co-ε- caprolactone) small-diameter vascular graft
    • DOI 10.1016/j.biomaterials.2005.08.029, PII S014296120500801X
    • Inoguchi H, Kwon IK, Inoue E, Takamizawa K, Maehara Y, Matsuda T. Mechanical responses of a compliant electrospun poly (L-lactide-co-epsilon- caprolactone) small-diameter vascular graft. Biomaterials 2006;27:1470-1478. (Pubitemid 41739573)
    • (2006) Biomaterials , vol.27 , Issue.8 , pp. 1470-1478
    • Inoguchi, H.1    Kwon, I.K.2    Inoue, E.3    Takamizawa, K.4    Maehara, Y.5    Matsuda, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.