메뉴 건너뛰기




Volumn 75, Issue 11, 2012, Pages 1951-1959

Efficient separation and sensitive detection of Listeria monocytogenes using an impedance immunosensor based on magnetic nanoparticles, a microfluidic chip, and an interdigitated microelectrode

Author keywords

[No Author keywords available]

Indexed keywords

BACTERIA (MICROORGANISMS); ESCHERICHIA COLI; ESCHERICHIA COLI K12; LACTUCA; LISTERIA MONOCYTOGENES; SALMONELLA TYPHIMURIUM; STAPHYLOCOCCUS AUREUS;

EID: 84868572167     PISSN: 0362028X     EISSN: None     Source Type: Journal    
DOI: 10.4315/0362-028X.JFP-11-516     Document Type: Article
Times cited : (68)

References (22)
  • 1
    • 0034973415 scopus 로고    scopus 로고
    • Listeria monocytogenes: A continuing challenge
    • Donnelly, C. W. 2001. Listeria monocytogenes: a continuing challenge. Nutr. Rev. 59:183-194.
    • (2001) Nutr. Rev. , vol.59 , pp. 183-194
    • Donnelly, C.W.1
  • 2
    • 11044222650 scopus 로고    scopus 로고
    • Synthesis and surface engineering of iron oxide nanoparticles for biomedical applications
    • Gupta, A. K., and M. Gupta. 2005. Synthesis and surface engineering of iron oxide nanoparticles for biomedical applications. Biomaterials 26:3995-4021.
    • (2005) Biomaterials , vol.26 , pp. 3995-4021
    • Gupta, A.K.1    Gupta, M.2
  • 3
    • 39549094018 scopus 로고    scopus 로고
    • Review: Current development in microfluidic immunosensing chip
    • Henares, T. G., F. Mizutani, and H. Hisamoto. 2008. Review: current development in microfluidic immunosensing chip. Anal. Chim. Acta 611:17-30.
    • (2008) Anal. Chim. Acta , vol.611 , pp. 17-30
    • Henares, T.G.1    Mizutani, F.2    Hisamoto, H.3
  • 4
    • 71849096724 scopus 로고    scopus 로고
    • An electrochemical impedimetric immunosensor for label-free detection of Campylobacter jejuni in diarrhea patients' stool based on Ocarboxymethylchitosan surface modified Fe3O4 nanoparticles
    • Huang, J., G. Yang, W. Meng, L. Wu, A. Zhu, and X. Jiao. 2010. An electrochemical impedimetric immunosensor for label-free detection of Campylobacter jejuni in diarrhea patients' stool based on Ocarboxymethylchitosan surface modified Fe3O4 nanoparticles. Biosens. Bioelectron. 25:1204-1211.
    • (2010) Biosens. Bioelectron. , vol.25 , pp. 1204-1211
    • Huang, J.1    Yang, G.2    Meng, W.3    Wu, L.4    Zhu, A.5    Jiao, X.6
  • 5
    • 34247530449 scopus 로고    scopus 로고
    • Nano-particle enhanced impedimetric biosensor for detection of foodborne pathogens
    • Kim, G., J. H. Mun, and A. S. Om. 2007. Nano-particle enhanced impedimetric biosensor for detection of foodborne pathogens. J. Phys. Conf. Ser. 61:555-559.
    • (2007) J. Phys. Conf. Ser. , vol.61 , pp. 555-559
    • Kim, G.1    Mun, J.H.2    Om, A.S.3
  • 6
    • 79951934023 scopus 로고    scopus 로고
    • A portable impedance biosensor instrument for rapid detection of avian influenza virus
    • paper no. 1636, B2P-K3, Waikoloa, HI, 1 to 4 November 2010
    • Lin, J., J. Lum, R. Wang, S. Tung, B. Hargis, Y. Li, H. Lu, and L. Berghman. 2010. A portable impedance biosensor instrument for rapid detection of avian influenza virus, p. 1558-1563, paper no. 1636, B2P-K3. In Proceedings of the 9th Annual IEEE Conference on Sensors, Waikoloa, HI, 1 to 4 November 2010.
    • (2010) Proceedings of the 9th Annual IEEE Conference on Sensors , pp. 1558-1563
    • Lin, J.1    Lum, J.2    Wang, R.3    Tung, S.4    Hargis, B.5    Li, Y.6    Lu, H.7    Berghman, L.8
  • 7
    • 33847075868 scopus 로고    scopus 로고
    • Activities, achievements, and lessons learned during the first 10 years of the Foodborne Diseases Active Surveillance Network: 1996-2005
    • Scallan, E. 2007. Activities, achievements, and lessons learned during the first 10 years of the Foodborne Diseases Active Surveillance Network: 1996-2005. Clin. Infect. Dis. 44:718-725.
    • (2007) Clin. Infect. Dis. , vol.44 , pp. 718-725
    • Scallan, E.1
  • 8
    • 23044447186 scopus 로고    scopus 로고
    • Evaluation of the VIDAS Listeria in foods using Demi-Fraser and Fraser enrichment broths, as modification of AOAC Official Method 999.06 (AOAC Official Method 2004 .06)
    • Silbernagel, K., R. Jechorek, A. L. Kaufer, and R. L. Johnson. 2005. Evaluation of the VIDAS Listeria in foods using Demi-Fraser and Fraser enrichment broths, as modification of AOAC Official Method 999.06 (AOAC Official Method 2004.06). J. AOAC Int. 88:750-760.
    • (2005) J. AOAC Int. , vol.88 , pp. 750-760
    • Silbernagel, K.1    Jechorek, R.2    Kaufer, A.L.3    Johnson, R.L.4
  • 9
    • 0037307403 scopus 로고    scopus 로고
    • Highly sensitive immunoassay of free prostate-specific antigen in serum using europium (III) nanoparticle label technology
    • Soukka, T., K. Antonen, H. Härmä, A. M. Pelkkikangas, P. Huhtinen, and T. Lövgren. 2003. Highly sensitive immunoassay of free prostate-specific antigen in serum using europium (III) nanoparticle label technology. Clin. Chim. Acta 328:45-58.
    • (2003) Clin. Chim. Acta , vol.328 , pp. 45-58
    • Soukka, T.1    Antonen, K.2    Härmä, H.3    Pelkkikangas, A.M.4    Huhtinen, P.5    Lövgren, T.6
  • 10
    • 0035872345 scopus 로고    scopus 로고
    • Utilization of kinetically enhanced monovalent binding affinity by immunoassays based on multivalent nanoparticle-antibody bioconjugates
    • Soukka, T., H. Harma, J. Paukkunen, and T. Lovgren. 2001. Utilization of kinetically enhanced monovalent binding affinity by immunoassays based on multivalent nanoparticle-antibody bioconjugates. Anal. Chem. 73:2254-2260.
    • (2001) Anal. Chem. , vol.73 , pp. 2254-2260
    • Soukka, T.1    Harma, H.2    Paukkunen, J.3    Lovgren, T.4
  • 11
    • 0037290582 scopus 로고    scopus 로고
    • Selective detection of viable bacteria using dielectrophoretic impedance measured method
    • Suehiro, J., R. Hamada, D. Noutomi, M. Shutou, and M. Hara. 2003. Selective detection of viable bacteria using dielectrophoretic impedance measured method. J. Electrostat. 57:157-168.
    • (2003) J. Electrostat. , vol.57 , pp. 157-168
    • Suehiro, J.1    Hamada, R.2    Noutomi, D.3    Shutou, M.4    Hara, M.5
  • 12
    • 63849256479 scopus 로고    scopus 로고
    • Capture of Escherichia coli O157:H7 using immunomagnetic beads of different size and antibody conjugating chemistry
    • Tu, S.-I., S. Reed, A. Gehring, Y. He, and G. Paoli. 2009. Capture of Escherichia coli O157:H7 using immunomagnetic beads of different size and antibody conjugating chemistry. Sensors 9:717-730.
    • (2009) Sensors , vol.9 , pp. 717-730
    • Tu, S.-I.1    Reed, S.2    Gehring, A.3    He, Y.4    Paoli, G.5
  • 13
    • 33947713763 scopus 로고    scopus 로고
    • Interdigitated array microelectrode based impedance biosensor coupled with magnetic nanoparticleantibody conjugated for detection of Escherichia coli O157:H7 in food samples
    • Varshney, M., and Y. Li. 2007. Interdigitated array microelectrode based impedance biosensor coupled with magnetic nanoparticleantibody conjugated for detection of Escherichia coli O157:H7 in food samples. Biosens. Bioelectron. 22:2408-2414.
    • (2007) Biosens. Bioelectron. , vol.22 , pp. 2408-2414
    • Varshney, M.1    Li, Y.2
  • 14
    • 26044442505 scopus 로고    scopus 로고
    • Magnetic nanoparticle-antibody conjugates for the separation of Escherichia coli O157:H7 in ground beef
    • Varshney, M., L. Yang, X.-L. Su, and Y. Li. 2005. Magnetic nanoparticle-antibody conjugates for the separation of Escherichia coli O157:H7 in ground beef. J. Food Prot. 68:1804-1811.
    • (2005) J. Food Prot. , vol.68 , pp. 1804-1811
    • Varshney, M.1    Yang, L.2    Su, X.-L.3    Li, Y.4
  • 15
    • 67549132127 scopus 로고    scopus 로고
    • Interdigitated array microelectrode based impedance immunosensor for detection of avian influenza virus H5N1
    • Wang, R., Y. Wang, K. Lassiter, Y. Li, B. Hargis, S. Tung, L. Berghman, and W. Bottje. 2009. Interdigitated array microelectrode based impedance immunosensor for detection of avian influenza virus H5N1. Talanta 79:159-164.
    • (2009) Talanta , vol.79 , pp. 159-164
    • Wang, R.1    Wang, Y.2    Lassiter, K.3    Li, Y.4    Hargis, B.5    Tung, S.6    Berghman, L.7    Bottje, W.8
  • 16
    • 78651522189 scopus 로고    scopus 로고
    • Detection of Escherichia coli O157:H7 using interdigitated array microelectrode based immunosensor
    • Wang, Y., R. Wang, Y. Li, B. Srinivasan, S. Tung, H. Wang, M. F. Slavik, and C. L. Griffis. 2010. Detection of Escherichia coli O157:H7 using interdigitated array microelectrode based immunosensor. Biol. Eng. 2(2):49-62.
    • (2010) Biol. Eng. , vol.2 , Issue.2 , pp. 49-62
    • Wang, Y.1    Wang, R.2    Li, Y.3    Srinivasan, B.4    Tung, S.5    Wang, H.6    Slavik, M.F.7    Griffis, C.L.8
  • 17
    • 52949128745 scopus 로고    scopus 로고
    • Detection of foodborne pathogens using bioconjugated nanomaterials
    • Yang, H., H. Li, and X. Jiang. 2008. Detection of foodborne pathogens using bioconjugated nanomaterials. Microfluid. Nanofluid. 5:571-583.
    • (2008) Microfluid. Nanofluid. , vol.5 , pp. 571-583
    • Yang, H.1    Li, H.2    Jiang, X.3
  • 18
    • 34548407734 scopus 로고    scopus 로고
    • Rapid detection of Listeria monocytogenes by nanoparticle-based immunomagnetic separation and real-time PCR
    • Yang, H., L. Qu, A. N. Wimbrow, X. Jiang, and Y. Sun. 2007. Rapid detection of Listeria monocytogenes by nanoparticle-based immunomagnetic separation and real-time PCR. Int. J. Food Microbiol. 118:132-138.
    • (2007) Int. J. Food Microbiol. , vol.118 , pp. 132-138
    • Yang, H.1    Qu, L.2    Wimbrow, A.N.3    Jiang, X.4    Sun, Y.5
  • 19
    • 38349133990 scopus 로고    scopus 로고
    • Research review paper: Electrical/electrochemical impedance for rapid detection of foodborne pathogenic bacteria
    • Yang, L., and R. Bashir. 2008. Research review paper: electrical/electrochemical impedance for rapid detection of foodborne pathogenic bacteria. Biotechnol. Adv. 26:135-150.
    • (2008) Biotechnol. Adv. , vol.26 , pp. 135-150
    • Yang, L.1    Bashir, R.2
  • 20
    • 0242499142 scopus 로고    scopus 로고
    • Detection of viable Salmonella Typhimurium by impedance measurement of electrode capacitance and medium resistance
    • Yang, L., C. Ruan, and Y. Li. 2003. Detection of viable Salmonella Typhimurium by impedance measurement of electrode capacitance and medium resistance. Biosens. Bioelectron. 19:495-502.
    • (2003) Biosens. Bioelectron. , vol.19 , pp. 495-502
    • Yang, L.1    Ruan, C.2    Li, Y.3
  • 22
    • 69549083518 scopus 로고    scopus 로고
    • A polyethylene glycol (PEG) microfluidic chip with nanostructures for bacteria rapid patterning and detection
    • Yu, J., Z. Liu, Q. Liu, K. T. Yuen, A. F. T. Mak, M. Yang, and P. Leung. 2009. A polyethylene glycol (PEG) microfluidic chip with nanostructures for bacteria rapid patterning and detection. Sens. Actuators A. Phys. 154:288-294.
    • (2009) Sens. Actuators A. Phys. , vol.154 , pp. 288-294
    • Yu, J.1    Liu, Z.2    Liu, Q.3    Yuen, K.T.4    Mak, A.F.T.5    Yang, M.6    Leung, P.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.