-
1
-
-
0035222861
-
Use of positron emission tomography in animal research
-
Cherry SR, Gambhir SS. Use of positron emission tomography in animal research. ILAR J. 2001;42:219-232.
-
(2001)
ILAR J
, vol.42
, pp. 219-232
-
-
Cherry, S.R.1
Gambhir, S.S.2
-
2
-
-
84872889540
-
Development and NEMA imaging performance of a lower-cost higher-resolution animal PET-CT using PMT-quadrant-sharing technology [abstract]
-
Wong WH, Li H, Zhang Y, et al. Development and NEMA imaging performance of a lower-cost higher-resolution animal PET-CT using PMT-quadrant-sharing technology [abstract]. J Nucl Med. 2011;52(suppl 1):376.
-
(2011)
J Nucl Med.
, vol.52
, Issue.SUPPL. 1
, pp. 376
-
-
Wong, W.H.1
Li, H.2
Zhang, Y.3
-
3
-
-
62449218842
-
-
National Electrical Manufacturers Association (NEMA). NEMA Standards Publication NU 4-2008. Rosslyn, VA: NEMA
-
National Electrical Manufacturers Association (NEMA). Performance Measurements for Small Animal Positron Emission Tomographs (PETs). NEMA Standards Publication NU 4-2008. Rosslyn, VA: NEMA; 2008.
-
(2008)
Performance Measurements for Small Animal Positron Emission Tomographs (PETs)
-
-
-
4
-
-
0028493623
-
A 2-dimensional detector decoding study on BGO arrays with quadrant sharing photomultipliers
-
Wong WH, Uribe J, Hicks K, Zambelli M. A 2-dimensional detector decoding study on BGO arrays with quadrant sharing photomultipliers. IEEE Trans Nucl Sci. 1994;41:1453-1457.
-
(1994)
IEEE Trans Nucl Sci.
, vol.41
, pp. 1453-1457
-
-
Wong, W.H.1
Uribe, J.2
Hicks, K.3
Zambelli, M.4
-
5
-
-
0033341721
-
An elongated position sensitive block detector using the PMT quadrant sharing configuration and asymmetric light partition
-
Wong WH, Yokoyama S, Uribe J, et al. An elongated position sensitive block detector using the PMT quadrant sharing configuration and asymmetric light partition. IEEE Trans Nucl Sci. 1999;46:542-545.
-
(1999)
IEEE Trans Nucl Sci
, vol.46
, pp. 542-545
-
-
Wong, W.H.1
Yokoyama, S.2
Uribe, J.3
-
6
-
-
10744226730
-
An efficient detector production method for position-sensitive scintillation detector arrays with 98% detector packing fraction
-
Uribe J, Wong WH, Baghaei H, et al. An efficient detector production method for position-sensitive scintillation detector arrays with 98% detector packing fraction. IEEE Trans Nucl Sci. 2003;50:1469-1476.
-
(2003)
IEEE Trans Nucl Sci
, vol.50
, pp. 1469-1476
-
-
Uribe, J.1
Wong, W.H.2
Baghaei, H.3
-
7
-
-
20244389194
-
A pentagon photomultiplier-quadrant-sharing BGO detector for a rodent research PET (RRPET)
-
Xie S, Ramirez R, Liu Y, et al. A pentagon photomultiplier-quadrant- sharing BGO detector for a rodent research PET (RRPET). IEEE Trans Nucl Sci. 2005;52: 210-216.
-
(2005)
IEEE Trans Nucl Sci.
, vol.52
, pp. 210-216
-
-
Xie, S.1
Ramirez, R.2
Liu, Y.3
-
8
-
-
45849088867
-
High-resolution L(Y)SO detectors using PMTquadrant-sharing for human and animal PET cameras
-
Ramirez RA, Liu S, Liu J, et al. High-resolution L(Y)SO detectors using PMTquadrant-sharing for human and animal PET cameras. IEEE Trans Nucl Sci. 2008; 55:862-869.
-
(2008)
IEEE Trans Nucl Sci
, vol.55
, pp. 862-869
-
-
Ramirez, R.A.1
Liu, S.2
Liu, J.3
-
9
-
-
79959379703
-
Ultra-high resolution LYSO PQS-SSS heptahedron blocks for low-cost MuPET
-
Ramirez RA, An S, Liu S, et al. Ultra-high resolution LYSO PQS-SSS heptahedron blocks for low-cost MuPET. IEEE Trans Nucl Sci. 2011;58:626-633.
-
(2011)
IEEE Trans Nucl Sci
, vol.58
, pp. 626-633
-
-
Ramirez, R.A.1
An, S.2
Liu, S.3
-
10
-
-
62449092307
-
Performance evaluation of the Inveon dedicated PET preclinical tomograph based on the NEMA NU-4 standards
-
Bao Q, Newport D, Chen M, Stout DB, Chatziioannou AF. Performance evaluation of the Inveon dedicated PET preclinical tomograph based on the NEMA NU-4 standards. J Nucl Med. 2009;50:401-408.
-
(2009)
J Nucl Med
, vol.50
, pp. 401-408
-
-
Bao, Q.1
Newport, D.2
Chen, M.3
Stout, D.B.4
Chatziioannou, A.F.5
-
11
-
-
80455129822
-
National Electrical Manufacturers Association NU-4 performance evaluation of the PET component of the NanoPET/CT preclinical PET/CT scanner
-
Szanda I, Mackewn J, Patay G, et al. National Electrical Manufacturers Association NU-4 performance evaluation of the PET component of the NanoPET/CT preclinical PET/CT scanner. J Nucl Med. 2011;52:1741-1747.
-
(2011)
J Nucl Med
, vol.52
, pp. 1741-1747
-
-
Szanda, I.1
MacKewn, J.2
Patay, G.3
-
12
-
-
80053580317
-
NEMA NU-04-based performance characteristics of the LabPET-8 small animal PET scanner
-
Prasad R, Ratib O, Zaidi H. NEMA NU-04-based performance characteristics of the LabPET-8 small animal PET scanner. Phys Med Biol. 2011;56:6649-6664
-
(2011)
Phys Med Biol
, vol.56
, pp. 6649-6664
-
-
Prasad, R.1
Ratib, O.2
Zaidi, H.3
-
13
-
-
0035043959
-
Feasibility of a high-speed gamma-camera design using the high-yield-pileup-event-recovery method
-
Wong WH, Li H, Uribe J, Baghaei H. Feasibility of a high-speed gamma-camera design using the high-yield-pileup-event-recovery method. J Nucl Med. 2001;42: 624-632.
-
(2001)
J Nucl Med
, vol.42
, pp. 624-632
-
-
Wong, W.H.1
Li, H.2
Uribe, J.3
Baghaei, H.4
-
14
-
-
77951195164
-
A new statistics-based online baseline restorer (SOBLR) for a high count-rate fully digital system
-
Li H, Wang C, Baghaei H, et al. A new statistics-based online baseline restorer (SOBLR) for a high count-rate fully digital system. IEEE Trans Nucl Sci. 2010; 57:550-555.
-
(2010)
IEEE Trans Nucl Sci.
, vol.57
, pp. 550-555
-
-
Li, H.1
Wang, C.2
Baghaei, H.3
-
15
-
-
80054088407
-
Timing performance evaluation of PMT-quadrant-sharing LYSO detectors for time-of-flight PET
-
An S, Li H, Liu S, et al. Timing performance evaluation of PMT-quadrant-sharing LYSO detectors for time-of-flight PET. IEEE Trans Nucl Sci. 2011;58:2155-2160.
-
(2011)
IEEE Trans Nucl Sci
, vol.58
, pp. 2155-2160
-
-
An, S.1
Li, H.2
Liu, S.3
-
16
-
-
0023640412
-
Treatment of axial data in three dimensional PET
-
Daube-Witherspoon ME, Muehllehner G. Treatment of axial data in three dimensional PET. J Nucl Med. 1987;28:1717-1724.
-
(1987)
J Nucl Med
, vol.28
, pp. 1717-1724
-
-
Daube-Witherspoon, M.E.1
Muehllehner, G.2
-
17
-
-
67649212973
-
High-definition positron emission tomography Using restored sinograms
-
Li H, Wang C, Baghaei H, et al. High-definition positron emission tomography Using restored sinograms. IEEE Nucl Sci Symp Conf. Rec. 2008;4373-4377.
-
(2008)
IEEE Nucl Sci Symp Conf. Rec.
, pp. 4373-4377
-
-
Li, H.1
Wang, C.2
Baghaei, H.3
-
18
-
-
0034244763
-
Accurate image reconstruction using DOI information and its implications for the development of compact PET systems
-
Kao CM, Pan X, Chen CT. Accurate image reconstruction using DOI information and its implications for the development of compact PET systems. IEEE Trans Nucl Sci. 2000;47:1551-1560.
-
(2000)
IEEE Trans Nucl Sci
, vol.47
, pp. 1551-1560
-
-
Kao, C.M.1
Pan, X.2
Chen, C.T.3
-
19
-
-
0024610693
-
Analytic 3D image reconstruction using all detected events
-
Kinahan PE, Rogers JG. Analytic 3D image reconstruction using all detected events. IEEE Trans Nucl Sci. 1989;36:964-968.
-
(1989)
IEEE Trans Nucl Sci
, vol.36
, pp. 964-968
-
-
Kinahan, P.E.1
Rogers, J.G.2
-
20
-
-
0037291830
-
Evaluation of the effect of filter apodization for volume PET imaging using the 3-D RP algorithm
-
Baghaei H, Wong WH, Li H, et al. Evaluation of the effect of filter apodization for volume PET imaging using the 3-D RP algorithm. IEEE Trans Nucl Sci. 2003;50:3-8.
-
(2003)
IEEE Trans Nucl Sci
, vol.50
, pp. 3-8
-
-
Baghaei, H.1
Wong, W.H.2
Li, H.3
-
21
-
-
67649173704
-
A new component-based normalization method for PET cameras [abstract]
-
Baghaei H, Li H, Wang Y, et al. A new component-based normalization method for PET cameras [abstract]. J Nucl Med. 2007;48(suppl):432P.
-
(2007)
J Nucl Med.
, vol.48
, Issue.SUPPL.
-
-
Baghaei, H.1
Li, H.2
Wang, Y.3
-
22
-
-
84930350777
-
A new self-normalization for PET cameras [abstract]
-
Zhang Y, Li H, Baghaei H, et al. A new self-normalization for PET cameras [abstract]. J Nucl Med. 2008;49(suppl):64P.
-
(2008)
J Nucl Med.
, vol.49
, Issue.SUPPL.
-
-
Zhang, Y.1
Li, H.2
Baghaei, H.3
-
23
-
-
0028700063
-
Accelerated image reconstruction using ordered subsets of projection data
-
Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging. 1994;13:601-609.
-
(1994)
IEEE Trans Med Imaging
, vol.13
, pp. 601-609
-
-
Hudson, H.M.1
Larkin, R.S.2
-
24
-
-
0036816150
-
An evaluation of the effect of filtering in 3-D OSEM reconstruction using data from a high-resolution PET scanner
-
Baghaei H, Uribe J, Li H, et al. An evaluation of the effect of filtering in 3-D OSEM reconstruction using data from a high-resolution PET scanner. IEEE Trans Nucl Sci. 2002;49:2381-2386.
-
(2002)
IEEE Trans Nucl Sci
, vol.49
, pp. 2381-2386
-
-
Baghaei, H.1
Uribe, J.2
Li, H.3
-
25
-
-
67649883194
-
Performance evaluation of an Inveon PET preclinical scanner
-
Constantinescu CC, Mukherjee J. Performance evaluation of an Inveon PET preclinical scanner. Phys Med Biol. 2009;54:2885-2899.
-
(2009)
Phys Med Biol
, vol.54
, pp. 2885-2899
-
-
Constantinescu, C.C.1
Mukherjee, J.2
|