메뉴 건너뛰기




Volumn 83, Issue 12, 2012, Pages 1438-1443

A low tilt waveform in the transthoracic defibrillation of ventricular arrhythmias during cardiac arrest

Author keywords

Defibrillation; Low tilt; Ventricular fibrillation; Waveform

Indexed keywords

ADULT; AGED; ARTICLE; CARDIOVERSION; DEFIBRILLATION; DEFIBRILLATOR; ELECTRIC ACTIVITY; ELECTROCARDIOGRAM; EMERGENCY MEDICAL SERVICES EDUCATION; ENERGY; FEMALE; HEART MUSCLE INJURY; HEART RHYTHM; HEART VENTRICLE ARRHYTHMIA; HEART VENTRICLE TACHYCARDIA; HUMAN; MAJOR CLINICAL STUDY; MALE; OUT OF HOSPITAL CARDIAC ARREST; PRIORITY JOURNAL; RESUSCITATION; RETURN OF SPONTANEOUS CIRCULATION; THORAX; WAVEFORM;

EID: 84868194067     PISSN: 03009572     EISSN: 18731570     Source Type: Journal    
DOI: 10.1016/j.resuscitation.2012.04.018     Document Type: Article
Times cited : (3)

References (24)
  • 1
    • 9044245698 scopus 로고    scopus 로고
    • Relative efficacy of different tilts with biphasic defibrillation in humans
    • Natale A., Sra J., Krum D., et al. Relative efficacy of different tilts with biphasic defibrillation in humans. Pacing Clin Electrophysiol 1996, 19:197-206.
    • (1996) Pacing Clin Electrophysiol , vol.19 , pp. 197-206
    • Natale, A.1    Sra, J.2    Krum, D.3
  • 3
    • 1842507622 scopus 로고    scopus 로고
    • Comparing the efficacy and safety of a novel monophasic waveform delivered by the Passive Implantable Atrial Defibrillator with biphasic waveforms in cardioversion of atrial fibrillation
    • Manoharan G., Evans N., Allen D., Anderson J., Adgey A.A.J. Comparing the efficacy and safety of a novel monophasic waveform delivered by the Passive Implantable Atrial Defibrillator with biphasic waveforms in cardioversion of atrial fibrillation. Circulation 2004, 109:1686-1692.
    • (2004) Circulation , vol.109 , pp. 1686-1692
    • Manoharan, G.1    Evans, N.2    Allen, D.3    Anderson, J.4    Adgey, A.A.J.5
  • 4
    • 0024206230 scopus 로고
    • Strength-duration curves of fixed pulse width variable tilt truncated exponential waveforms for nonthoracotomy internal defibrillation in dogs
    • Chapman P.D., Wetherbee J.N., Vetter J.W., Troup P., Souza J. Strength-duration curves of fixed pulse width variable tilt truncated exponential waveforms for nonthoracotomy internal defibrillation in dogs. Pacing Clin Electrophysiol 1988, 11:1045-1050.
    • (1988) Pacing Clin Electrophysiol , vol.11 , pp. 1045-1050
    • Chapman, P.D.1    Wetherbee, J.N.2    Vetter, J.W.3    Troup, P.4    Souza, J.5
  • 5
    • 0024591031 scopus 로고
    • Ventricular defibrillation using biphasic waveforms: the importance of phasic duration
    • Tang A.S., Yabe S., Wharton J.M., Dolker M., Smith W.M., Ideker R.E. Ventricular defibrillation using biphasic waveforms: the importance of phasic duration. J Am Coll Cardiol 1989, 13:207-214.
    • (1989) J Am Coll Cardiol , vol.13 , pp. 207-214
    • Tang, A.S.1    Yabe, S.2    Wharton, J.M.3    Dolker, M.4    Smith, W.M.5    Ideker, R.E.6
  • 6
    • 0025637041 scopus 로고
    • Strength-duration and probability of success curves for defibrillation with biphasic waveforms
    • Feeser S.A., Tang A.S., Kavanagh K.M., et al. Strength-duration and probability of success curves for defibrillation with biphasic waveforms. Circulation 1990, 82:2128-2141.
    • (1990) Circulation , vol.82 , pp. 2128-2141
    • Feeser, S.A.1    Tang, A.S.2    Kavanagh, K.M.3
  • 7
    • 0028926798 scopus 로고
    • Optimal truncation of defibrillation pulses
    • Irnich W. Optimal truncation of defibrillation pulses. Pacing Clin Electrophysiol 1995, 18:673-688.
    • (1995) Pacing Clin Electrophysiol , vol.18 , pp. 673-688
    • Irnich, W.1
  • 8
    • 0033600540 scopus 로고    scopus 로고
    • Fully discharging phases: a new approach to biphasic waveforms for external defibrillation
    • Yamanouchi Y., Brewer J.E., Olson K.F., et al. Fully discharging phases: a new approach to biphasic waveforms for external defibrillation. Circulation 1999, 100:826-831.
    • (1999) Circulation , vol.100 , pp. 826-831
    • Yamanouchi, Y.1    Brewer, J.E.2    Olson, K.F.3
  • 9
    • 78049456647 scopus 로고    scopus 로고
    • European Resuscitation Council guidelines for resuscitation 2010. Section 3: electrical therapies: automated external defibrillators, defibrillation, cardioversion and pacing
    • Deakin C.D., Nolan J.P., Sunde K., Koster R.W. European Resuscitation Council guidelines for resuscitation 2010. Section 3: electrical therapies: automated external defibrillators, defibrillation, cardioversion and pacing. Resuscitation 2010, 81:1293-1304.
    • (2010) Resuscitation , vol.81 , pp. 1293-1304
    • Deakin, C.D.1    Nolan, J.P.2    Sunde, K.3    Koster, R.W.4
  • 10
    • 70350058823 scopus 로고    scopus 로고
    • A novel low tilt biphasic waveform is more efficacious than a standard waveform in the defibrillation of VF
    • Darragh K.M., Doyle C., Walsh S.J., et al. A novel low tilt biphasic waveform is more efficacious than a standard waveform in the defibrillation of VF. Europace 2007, 9:ii4.
    • (2007) Europace , vol.9
    • Darragh, K.M.1    Doyle, C.2    Walsh, S.J.3
  • 11
    • 84946650481 scopus 로고
    • Probable inference, the law of succession, and statistical inference
    • Wilson E.B. Probable inference, the law of succession, and statistical inference. J Am Stat Assoc 1927, 22:209-212.
    • (1927) J Am Stat Assoc , vol.22 , pp. 209-212
    • Wilson, E.B.1
  • 12
    • 0034633848 scopus 로고    scopus 로고
    • Multicenter, randomized, controlled trial of 150-J biphasic shocks compared with 200- to 360-J monophasic shocks in the resuscitation of out-of-hospital cardiac arrest victims
    • Schneider T., Martens P.R., Paschen H., et al. Multicenter, randomized, controlled trial of 150-J biphasic shocks compared with 200- to 360-J monophasic shocks in the resuscitation of out-of-hospital cardiac arrest victims. Circulation 2000, 102:1780-1787.
    • (2000) Circulation , vol.102 , pp. 1780-1787
    • Schneider, T.1    Martens, P.R.2    Paschen, H.3
  • 13
    • 0038642762 scopus 로고    scopus 로고
    • A prospective randomised and blinded comparison of first shock success of monophasic and biphasic waveforms in out-of-hospital cardiac arrest
    • van Alem A.P., Chapman F.W., Lank P., Hart A.A.M., Koster R.W. A prospective randomised and blinded comparison of first shock success of monophasic and biphasic waveforms in out-of-hospital cardiac arrest. Resuscitation 2003, 58:17-24.
    • (2003) Resuscitation , vol.58 , pp. 17-24
    • van Alem, A.P.1    Chapman, F.W.2    Lank, P.3    Hart, A.A.M.4    Koster, R.W.5
  • 14
    • 84880336090 scopus 로고    scopus 로고
    • Department of health policy and guidance. Taking healthcare to the patient. Transforming NHS ambulance services. Available at: Annex C; (accessed 02.08.11).
    • Department of health policy and guidance. Taking healthcare to the patient. Transforming NHS ambulance services. Available at: Annex C; 2005 (accessed 02.08.11). http://www.dh.gov.uk/prod_consum_dh/groups/dh_digitalassets/@dh/@en/documents/digitalasset/dh_4114270.pdf.
    • (2005)
  • 15
    • 0031020630 scopus 로고    scopus 로고
    • Rounded biphasic waveform reduces energy requirements for transvenous catheter cardioversion of atrial fibrillation and flutter
    • Harbinson M.T., Allen J.D., Imam Z., et al. Rounded biphasic waveform reduces energy requirements for transvenous catheter cardioversion of atrial fibrillation and flutter. Pacing Clin Electrophysiol 1997, 20:226-229.
    • (1997) Pacing Clin Electrophysiol , vol.20 , pp. 226-229
    • Harbinson, M.T.1    Allen, J.D.2    Imam, Z.3
  • 16
    • 0141430981 scopus 로고    scopus 로고
    • Novel Passive Implantable Atrial Defibrillator using transcutaneous radiofrequency energy transmission successfully cardioverts atrial fibrillation
    • Manoharan G., Evans N., Kidwai B.J., Allen D., Anderson J., Adgey A.A.J. Novel Passive Implantable Atrial Defibrillator using transcutaneous radiofrequency energy transmission successfully cardioverts atrial fibrillation. Circulation 2003, 108:1382-1388.
    • (2003) Circulation , vol.108 , pp. 1382-1388
    • Manoharan, G.1    Evans, N.2    Kidwai, B.J.3    Allen, D.4    Anderson, J.5    Adgey, A.A.J.6
  • 17
    • 33749670133 scopus 로고    scopus 로고
    • Novel rectangular biphasic and monophasic waveforms delivered by a radiofrequency powered defibrillator compared with conventional capacitor based waveforms in transvenous cardioversion of atrial fibrillation
    • Walsh S.J., Manoharan G.M., Escalona O.J., et al. Novel rectangular biphasic and monophasic waveforms delivered by a radiofrequency powered defibrillator compared with conventional capacitor based waveforms in transvenous cardioversion of atrial fibrillation. Europace 2006, 8:873-880.
    • (2006) Europace , vol.8 , pp. 873-880
    • Walsh, S.J.1    Manoharan, G.M.2    Escalona, O.J.3
  • 18
    • 0027453975 scopus 로고
    • Optimization of biphasic waveforms for human nonthoracotomy defibrillation
    • Swartz J.F., Fletcher R.D., Karasik P.E. Optimization of biphasic waveforms for human nonthoracotomy defibrillation. Circulation 1993, 88:2646-2654.
    • (1993) Circulation , vol.88 , pp. 2646-2654
    • Swartz, J.F.1    Fletcher, R.D.2    Karasik, P.E.3
  • 19
    • 8544273679 scopus 로고    scopus 로고
    • The effect of biphasic waveforms tilt in transvenous atrial defibrillation
    • Sra J., Bremner S., Krum D., et al. The effect of biphasic waveforms tilt in transvenous atrial defibrillation. Pacing Clin Electrophysiol 1997, 20:1613-1618.
    • (1997) Pacing Clin Electrophysiol , vol.20 , pp. 1613-1618
    • Sra, J.1    Bremner, S.2    Krum, D.3
  • 20
    • 48249157883 scopus 로고    scopus 로고
    • A pilot study of a low tilt biphasic waveform for transvenous cardioversion of atrial fibrillation: improved efficacy compared with conventional capacitor-based waveforms in patients
    • Glover B.M., McCann C.J., Manoharan G., et al. A pilot study of a low tilt biphasic waveform for transvenous cardioversion of atrial fibrillation: improved efficacy compared with conventional capacitor-based waveforms in patients. Pacing Clin Electrophysiol 2008, 31:1020-1024.
    • (2008) Pacing Clin Electrophysiol , vol.31 , pp. 1020-1024
    • Glover, B.M.1    McCann, C.J.2    Manoharan, G.3
  • 21
    • 0025094535 scopus 로고
    • The fundamental law of electrostimulation and its application to defibrillation
    • Irnich W. The fundamental law of electrostimulation and its application to defibrillation. Pacing Clin Electrophysiol 1990, 13:1433-1447.
    • (1990) Pacing Clin Electrophysiol , vol.13 , pp. 1433-1447
    • Irnich, W.1
  • 22
    • 1842478223 scopus 로고    scopus 로고
    • The effects of biphasic waveform design on post-resuscitation myocardial function
    • Tang W., Weil M., Sun S., et al. The effects of biphasic waveform design on post-resuscitation myocardial function. J Am Coll Cardiol 2004, 43:1228-1235.
    • (2004) J Am Coll Cardiol , vol.43 , pp. 1228-1235
    • Tang, W.1    Weil, M.2    Sun, S.3
  • 23
    • 6544276577 scopus 로고    scopus 로고
    • Treatment of out-of-hospital cardiac arrest with a low-energy impedance-compensating biphasic waveform automatic external defibrillator. LIFE Investigators
    • Gliner B.E., Jorgenson D.B., Poole J.E., et al. Treatment of out-of-hospital cardiac arrest with a low-energy impedance-compensating biphasic waveform automatic external defibrillator. LIFE Investigators. Biomed Instrum Technol 1998, 32:631-644.
    • (1998) Biomed Instrum Technol , vol.32 , pp. 631-644
    • Gliner, B.E.1    Jorgenson, D.B.2    Poole, J.E.3
  • 24
    • 79956120749 scopus 로고    scopus 로고
    • Performance of a rectilinear biphasic waveform in defibrillation of presenting and recurrent ventricular fibrillation: aprospective multicenter study
    • Hess E.P., Agarwal D., Myers L.A., Atkinson E.J., White R.D. Performance of a rectilinear biphasic waveform in defibrillation of presenting and recurrent ventricular fibrillation: aprospective multicenter study. Resuscitation 2011, 82:685-689.
    • (2011) Resuscitation , vol.82 , pp. 685-689
    • Hess, E.P.1    Agarwal, D.2    Myers, L.A.3    Atkinson, E.J.4    White, R.D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.