메뉴 건너뛰기




Volumn 19, Issue 2, 1996, Pages 197-206

Relative efficacy of different tilts with biphasic defibrillation in humans

Author keywords

defibrillation threshold; implantable defibrillator; nonthoracotomy system; subthreshold shocks

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; COMPARATIVE STUDY; DEFIBRILLATION; DEFIBRILLATOR; FEMALE; HEART ARRHYTHMIA; HEART MUSCLE FIBER MEMBRANE; HUMAN; IMPLANTATION; MALE; OBSERVER VARIATION; SARCOLEMMA; TILTING;

EID: 9044245698     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1996.tb03311.x     Document Type: Article
Times cited : (29)

References (37)
  • 1
    • 0018975668 scopus 로고
    • Termination of malignant ventricular arrhythmias with an implanted automatic defibrillation in human beings
    • Mirowski M, Reid PR, Mower MM, et al. Termination of malignant ventricular arrhythmias with an implanted automatic defibrillation in human beings. N Engl J Med 1980; 303:322-324.
    • (1980) N Engl J Med , vol.303 , pp. 322-324
    • Mirowski, M.1    Reid, P.R.2    Mower, M.M.3
  • 2
    • 84909848777 scopus 로고
    • Operative (30-day) mortality with transvenous vs. epicardial ICD implantation: An intention-to-treat analysis
    • Lehmann MH, Mitchell LB, Saksena S, et al. Operative (30-day) mortality with transvenous vs. epicardial ICD implantation: An intention-to-treat analysis. (abstract) Circulation 1992; 86:I-656.
    • (1992) Circulation , vol.86
    • Lehmann, M.H.1    Mitchell, L.B.2    Saksena, S.3
  • 3
    • 0024455379 scopus 로고
    • Initial clinical experience with endocardial defibrillation using an implantable cardioverter/defibrillator with a triple-electrode system
    • Saksena S, Tullo NG, Krol RB, et al. Initial clinical experience with endocardial defibrillation using an implantable cardioverter/defibrillator with a triple-electrode system. Arch Intern Med 1989; 149:2333-2339.
    • (1989) Arch Intern Med , vol.149 , pp. 2333-2339
    • Saksena, S.1    Tullo, N.G.2    Krol, R.B.3
  • 4
    • 0025856363 scopus 로고
    • Automatic implantable cardioverter-defibrillator implantation without thoracotomy using an endocardial and submuscular patch system
    • McGowan R, Maloney J, Wilkoff B, et al. Automatic implantable cardioverter-defibrillator implantation without thoracotomy using an endocardial and submuscular patch system. J Am Coll Cardiol 1991; 17:415-421.
    • (1991) J Am Coll Cardiol , vol.17 , pp. 415-421
    • McGowan, R.1    Maloney, J.2    Wilkoff, B.3
  • 5
    • 0026504952 scopus 로고
    • Clinical experience with a tiered-therapy, multiprogrammable antiarrhythmia device
    • Bardy GH, Troutman C, Poole JE, et al. Clinical experience with a tiered-therapy, multiprogrammable antiarrhythmia device. Circulation 1992; 85:1689-1698.
    • (1992) Circulation , vol.85 , pp. 1689-1698
    • Bardy, G.H.1    Troutman, C.2    Poole, J.E.3
  • 6
    • 0026531999 scopus 로고
    • Implantable pacemaker cardioverter-defibrillator: Nonthoracotomy approach to implantation
    • Yee R, Klein GH, Leitch JW, et al. Implantable pacemaker cardioverter-defibrillator: Nonthoracotomy approach to implantation. Circulation 1992; 85: 196-204.
    • (1992) Circulation , vol.85 , pp. 196-204
    • Yee, R.1    Klein, G.H.2    Leitch, J.W.3
  • 7
    • 0027503267 scopus 로고
    • Implantable transvenous cardioverter-defibrillators
    • Bardy GH, Hofer B, Johnson G, et al. Implantable transvenous cardioverter-defibrillators. Circulation 1993; 87:1152-1168.
    • (1993) Circulation , vol.87 , pp. 1152-1168
    • Bardy, G.H.1    Hofer, B.2    Johnson, G.3
  • 8
    • 0025887825 scopus 로고
    • Experience with a third-generation implantable cardioverter-defibrillator
    • Saksena S, Davendra M, Krol RB, et al. Experience with a third-generation implantable cardioverter-defibrillator. Am J Cardiol 1991; 67:1375-1384.
    • (1991) Am J Cardiol , vol.67 , pp. 1375-1384
    • Saksena, S.1    Davendra, M.2    Krol, R.B.3
  • 9
    • 9044220342 scopus 로고
    • Experience with two different non-thoracotomy lead systems for implantable defibrillator in 138 consecutive pa-tients
    • Natale A, Dhala A, Babe J, et al. Experience with two different non-thoracotomy lead systems for implantable defibrillator in 138 consecutive pa-tients. (abstract) Circulation 1993; 88(Suppl. I):I-215.
    • (1993) Circulation , vol.88 , Issue.1 SUPPL.
    • Natale, A.1    Dhala, A.2    Babe, J.3
  • 10
    • 0027442215 scopus 로고
    • Determinants of successful nonthoracotomy cardioverter-defibrillator implantation: Experience in 101 patients using two different lead systems
    • Brooks R, Garan H, Torchiana D, et al. Determinants of successful nonthoracotomy cardioverter-defibrillator implantation: Experience in 101 patients using two different lead systems. J Am Coll Cardiol 1993; 22:1835-1842.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 1835-1842
    • Brooks, R.1    Garan, H.2    Torchiana, D.3
  • 11
    • 0026536358 scopus 로고
    • Cardiac potential and potential gradient fields generated by single, combined, and sequential shocks during ventricular defibrillation
    • Wharton J, Wolf P, Smith W, et al. Cardiac potential and potential gradient fields generated by single, combined, and sequential shocks during ventricular defibrillation. Circulation 1992; 85:1510-1523.
    • (1992) Circulation , vol.85 , pp. 1510-1523
    • Wharton, J.1    Wolf, P.2    Smith, W.3
  • 12
    • 0025009414 scopus 로고
    • An effective and adaptable transvenous defibrillation system for use in humans
    • Bardy GH, Allen MC, Mehra R, et al. An effective and adaptable transvenous defibrillation system for use in humans. J Am Coll Cardiol 1990; 16: 887-895.
    • (1990) J Am Coll Cardiol , vol.16 , pp. 887-895
    • Bardy, G.H.1    Allen, M.C.2    Mehra, R.3
  • 13
    • 0011852420 scopus 로고
    • An experimental and clinical study of a portable external cardiac defibrillator
    • Jude JR, Kouwenhoven WB, Knickerbocker G. An experimental and clinical study of a portable external cardiac defibrillator. Surg Forum 1962; 13: 185-187.
    • (1962) Surg Forum , vol.13 , pp. 185-187
    • Jude, J.R.1    Kouwenhoven, W.B.2    Knickerbocker, G.3
  • 14
    • 0024552857 scopus 로고
    • Improved low energy defibrillation efficacy in man with the use of a biphasic truncated exponential waveform
    • Winkle RA, Mead RH, Ruder MA, et al. Improved low energy defibrillation efficacy in man with the use of a biphasic truncated exponential waveform. Am Heart J 1989; 117:122-127.
    • (1989) Am Heart J , vol.117 , pp. 122-127
    • Winkle, R.A.1    Mead, R.H.2    Ruder, M.A.3
  • 15
    • 0024538635 scopus 로고
    • Improved internal defibrillation efficacy with a biphasic waveform
    • Fain ES, Sweeney MB, Franz MR. Improved internal defibrillation efficacy with a biphasic waveform. Am Heart J 1989; 117:358-364.
    • (1989) Am Heart J , vol.117 , pp. 358-364
    • Fain, E.S.1    Sweeney, M.B.2    Franz, M.R.3
  • 16
    • 0025598072 scopus 로고
    • Efficacy and safety of monophasic and biphasic waveform shocks using a braided endocardial defibrillation lead system
    • Saksena S, Scott SE, Accorti PR, et al. Efficacy and safety of monophasic and biphasic waveform shocks using a braided endocardial defibrillation lead system. Am Heart J 1990; 120:1342-1347.
    • (1990) Am Heart J , vol.120 , pp. 1342-1347
    • Saksena, S.1    Scott, S.E.2    Accorti, P.R.3
  • 17
    • 0024323674 scopus 로고
    • Superiority of biphasic shocks in the defibrillation of dogs by epicardial patches and catheter electrodes
    • Flaker GC, Schuder JC, McDaniel WC, et al. Superiority of biphasic shocks in the defibrillation of dogs by epicardial patches and catheter electrodes. Am Heart J 1989; 118:288-291.
    • (1989) Am Heart J , vol.118 , pp. 288-291
    • Flaker, G.C.1    Schuder, J.C.2    McDaniel, W.C.3
  • 18
    • 0027452637 scopus 로고
    • Comparison of biphasic and monophasic shocks for defibrillation using a nonthoracotomy system
    • Wyse DG, Kavanagh KM, Gillis AM, et al. Comparison of biphasic and monophasic shocks for defibrillation using a nonthoracotomy system. Am J Cardiol 1992; 71:197-202.
    • (1992) Am J Cardiol , vol.71 , pp. 197-202
    • Wyse, D.G.1    Kavanagh, K.M.2    Gillis, A.M.3
  • 19
    • 0026774142 scopus 로고
    • Prospective comparison of biphasic and monophasic shocks for implantable cardioverter-defibrillators using endocardial leads
    • Saksena S, Huanlin A, Mehra R, et al. Prospective comparison of biphasic and monophasic shocks for implantable cardioverter-defibrillators using endocardial leads. Am J Cardiol 1992; 70:304-310.
    • (1992) Am J Cardiol , vol.70 , pp. 304-310
    • Saksena, S.1    Huanlin, A.2    Mehra, R.3
  • 20
    • 0024448644 scopus 로고
    • A prospective randomized evaluation of biphasic versus monophasic waveform pulses on defibrillation efficacy in humans
    • Bardy G, Ivey T, Allen M, et al. A prospective randomized evaluation of biphasic versus monophasic waveform pulses on defibrillation efficacy in humans. J Am Coll Cardiol 1989; 14:728-733.
    • (1989) J Am Coll Cardiol , vol.14 , pp. 728-733
    • Bardy, G.1    Ivey, T.2    Allen, M.3
  • 21
    • 0023206065 scopus 로고
    • Improved defibrillation thresholds with large contoured epicardial electrodes and biphasic waveforms
    • Dixon E, Tang A, Wolf P, et al. Improved defibrillation thresholds with large contoured epicardial electrodes and biphasic waveforms. Circulation 1987; 5:1176-1184.
    • (1987) Circulation , vol.5 , pp. 1176-1184
    • Dixon, E.1    Tang, A.2    Wolf, P.3
  • 22
    • 0024450327 scopus 로고
    • Comparison of the internal defibrillation thresholds for monophasic and double and single capacitor biphasic waveforms
    • Kavanagh K, Tang A, Rollins D, et al. Comparison of the internal defibrillation thresholds for monophasic and double and single capacitor biphasic waveforms. J Am Coll Cardiol 1989; 14: 1343-1349.
    • (1989) J Am Coll Cardiol , vol.14 , pp. 1343-1349
    • Kavanagh, K.1    Tang, A.2    Rollins, D.3
  • 23
    • 0024591031 scopus 로고
    • Ventricular defibrillation using biphasic waveforms: The importance of phasic duration
    • Tang A, Yabe S, Wharton M, et al. Ventricular defibrillation using biphasic waveforms: The importance of phasic duration. J Am Coll Cardiol 1989; 13:207-214.
    • (1989) J Am Coll Cardiol , vol.13 , pp. 207-214
    • Tang, A.1    Yabe, S.2    Wharton, M.3
  • 24
    • 85047675188 scopus 로고
    • Defibrillation of 100-kg calves with asymmetrical, bidirectional, rectangular pulses
    • Schuder JC, McDaniel WC, Stoeckle H. Defibrillation of 100-kg calves with asymmetrical, bidirectional, rectangular pulses. Cardiovasc Res 1984; 18:419-426.
    • (1984) Cardiovasc Res , vol.18 , pp. 419-426
    • Schuder, J.C.1    McDaniel, W.C.2    Stoeckle, H.3
  • 25
    • 0021645503 scopus 로고
    • Transthoracic defibrillation of 100-kg calves with bidirectional truncated exponential shocks
    • Schuder JC, McDaniel WC, Stoeckle H. Transthoracic defibrillation of 100-kg calves with bidirectional truncated exponential shocks. Trans Am Soc Artif Intern Organs 1984; 30:520-525.
    • (1984) Trans Am Soc Artif Intern Organs , vol.30 , pp. 520-525
    • Schuder, J.C.1    McDaniel, W.C.2    Stoeckle, H.3
  • 26
    • 0025878541 scopus 로고
    • Electrode system influence on biphasic waveform defibrillation efficacy in humans
    • Bardy G, Troutman C, Johnson G, et al. Electrode system influence on biphasic waveform defibrillation efficacy in humans. Circulation 1991; 84: 665-671.
    • (1991) Circulation , vol.84 , pp. 665-671
    • Bardy, G.1    Troutman, C.2    Johnson, G.3
  • 27
    • 0026035353 scopus 로고
    • Current concepts for selecting the location, size and shape of defibrillation electrodes
    • Ideker R, Wolf P, Alferness C, et al. Current concepts for selecting the location, size and shape of defibrillation electrodes. PACE 1991; 14:227-240.
    • (1991) PACE , vol.14 , pp. 227-240
    • Ideker, R.1    Wolf, P.2    Alferness, C.3
  • 28
    • 0019193991 scopus 로고
    • Cardiac damage caused by direct application of defibrillation shock to isolated Langendorff-perfused rabbit heart
    • Koning G, Veefkind AH, Schneider H. Cardiac damage caused by direct application of defibrillation shock to isolated Langendorff-perfused rabbit heart. Am Heart J 1980; 100:473-482.
    • (1980) Am Heart J , vol.100 , pp. 473-482
    • Koning, G.1    Veefkind, A.H.2    Schneider, H.3
  • 29
    • 0002667051 scopus 로고
    • Cardiac arrhythmias following condenser discharges and their dependence upon strength of current and phase of cardiac cycle
    • Peleska B. Cardiac arrhythmias following condenser discharges and their dependence upon strength of current and phase of cardiac cycle. Circ Res 1963; 13:21-32.
    • (1963) Circ Res , vol.13 , pp. 21-32
    • Peleska, B.1
  • 30
    • 0014085456 scopus 로고
    • Ventricular arrhythmias after precordial electric shock
    • Donoso E, Cohn LH, Friedberg CK. Ventricular arrhythmias after precordial electric shock. Am Heart J 1967; 73:595-601.
    • (1967) Am Heart J , vol.73 , pp. 595-601
    • Donoso, E.1    Cohn, L.H.2    Friedberg, C.K.3
  • 31
    • 0002354635 scopus 로고
    • Energy waveforms and lead systems for implantable defibrillators
    • B Lüderitz, S Saksena (eds.) Mount Kisco, NY, Futura Publishing Co., Inc.
    • Mehra R, DeGroot P, Norenbert M. Energy waveforms and lead systems for implantable defibrillators. In B Lüderitz, S Saksena (eds.): Interventional Electrophysiology. Mount Kisco, NY, Futura Publishing Co., Inc., 1991, pp. 377-394.
    • (1991) Interventional Electrophysiology , pp. 377-394
    • Mehra, R.1    DeGroot, P.2    Norenbert, M.3
  • 32
    • 0027213796 scopus 로고
    • Is the second phase of a biphasic defibrillation waveform the defibrillating phase?
    • Hillsley RE, Walker RG, Swanson DK, et al. Is the second phase of a biphasic defibrillation waveform the defibrillating phase? PACE 1993; 16: 1401-1411.
    • (1993) PACE , vol.16 , pp. 1401-1411
    • Hillsley, R.E.1    Walker, R.G.2    Swanson, D.K.3
  • 33
    • 0026026362 scopus 로고
    • Conditioning prepulse of biphasic defibrillator waveforms enhances refractoriness to fibrillation wavefronts
    • Swartz JF, Jones JL, Jones RE, et al. Conditioning prepulse of biphasic defibrillator waveforms enhances refractoriness to fibrillation wavefronts. Circ Res 1991; 68:438-449.
    • (1991) Circ Res , vol.68 , pp. 438-449
    • Swartz, J.F.1    Jones, J.L.2    Jones, R.E.3
  • 34
    • 0025840393 scopus 로고
    • Response of relatively refractory canine myocardium to monophasic and biphasic shocks
    • Daubert JP, Frazier DW, Wolf PD, et al. Response of relatively refractory canine myocardium to monophasic and biphasic shocks. Circulation 1991; 84:2522-2538.
    • (1991) Circulation , vol.84 , pp. 2522-2538
    • Daubert, J.P.1    Frazier, D.W.2    Wolf, P.D.3
  • 35
    • 0025794021 scopus 로고
    • Prolongation of repolarization time by electric field stimulation with monophasic and biphasic shocks in open-chest dogs
    • Zhou X, Knisley SB, Wolf PD, et al. Prolongation of repolarization time by electric field stimulation with monophasic and biphasic shocks in open-chest dogs. Circ Res 1991; 68:1761-1767.
    • (1991) Circ Res , vol.68 , pp. 1761-1767
    • Zhou, X.1    Knisley, S.B.2    Wolf, P.D.3
  • 36
    • 0025637041 scopus 로고
    • Strength-duration and probability of success curves for defibrillation with biphasic waveforms
    • Feeser SA, Tang AS, Kavanagh KM, et al. Strength-duration and probability of success curves for defibrillation with biphasic waveforms. Circulation 1990; 82:2128-2141.
    • (1990) Circulation , vol.82 , pp. 2128-2141
    • Feeser, S.A.1    Tang, A.S.2    Kavanagh, K.M.3
  • 37
    • 0027453975 scopus 로고
    • Optimization of biphasic waveforms for human nonthoracotomy defibrillation
    • Swartz JF, Fletcher RD, Karasik PE. Optimization of biphasic waveforms for human nonthoracotomy defibrillation. Circulation 1993; 88:2646-2654.
    • (1993) Circulation , vol.88 , pp. 2646-2654
    • Swartz, J.F.1    Fletcher, R.D.2    Karasik, P.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.