메뉴 건너뛰기




Volumn 11, Issue 6, 2012, Pages 528-535

Dosimetry comparison between TG-43 and Monte Carlo calculations using the Freiburg flap for skin high-dose-rate brachytherapy

Author keywords

192Ir; Brachytherapy; Dosimetry; Freiburg flap; Penelope2008

Indexed keywords

ARTICLE; BRACHYTHERAPY; DOSIMETRY; MONTE CARLO METHOD; PRIORITY JOURNAL; RADIATION APPLICATOR; RADIATION DOSE; SIMULATION; TREATMENT PLANNING; VALIDATION STUDY;

EID: 84868127849     PISSN: 15384721     EISSN: 18731449     Source Type: Journal    
DOI: 10.1016/j.brachy.2011.11.005     Document Type: Article
Times cited : (17)

References (21)
  • 2
    • 11244289512 scopus 로고    scopus 로고
    • Dosimetric characteristics of the Leipzig surface applicators used in the high dose rate brachy radiotherapy
    • Niu H., Hsi W.C., Chu J.C., et al. Dosimetric characteristics of the Leipzig surface applicators used in the high dose rate brachy radiotherapy. Med Phys 2004, 31:3372-3377.
    • (2004) Med Phys , vol.31 , pp. 3372-3377
    • Niu, H.1    Hsi, W.C.2    Chu, J.C.3
  • 3
    • 38849108040 scopus 로고    scopus 로고
    • Design and evaluation of a HDR skin applicator with flattening filter
    • Granero D., Perez-Calatayud J., Gimeno J., et al. Design and evaluation of a HDR skin applicator with flattening filter. Med Phys 2008, 35:495-503.
    • (2008) Med Phys , vol.35 , pp. 495-503
    • Granero, D.1    Perez-Calatayud, J.2    Gimeno, J.3
  • 4
    • 16344388628 scopus 로고    scopus 로고
    • Quantifying IOHDR brachytherapy underdosage resulting from an incomplete scatter environment
    • Raina S., Avadhani J.S., Oh M., et al. Quantifying IOHDR brachytherapy underdosage resulting from an incomplete scatter environment. Int J Radiat Oncol Biol Phys 2005, 61:1582-1586.
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , pp. 1582-1586
    • Raina, S.1    Avadhani, J.S.2    Oh, M.3
  • 6
    • 0003797116 scopus 로고    scopus 로고
    • PENELOPE-2008, a code system for Monte Carlo simulation of electron and photon transport
    • Issy-les-Moulineaux, France
    • Salvat F, Fernández-Varea JM, Sempau J. PENELOPE-2008, a code system for Monte Carlo simulation of electron and photon transport. Issy-les-Moulineaux, France; 2008.
    • (2008)
    • Salvat, F.1    Fernández-Varea, J.M.2    Sempau, J.3
  • 7
    • 1142287542 scopus 로고    scopus 로고
    • Benchmark of PENELOPE code for low-energy photon transport: Dose comparisons with MCNP4 and EGS4
    • Ye S.J., Brezovich I.A., Pareek P., et al. Benchmark of PENELOPE code for low-energy photon transport: Dose comparisons with MCNP4 and EGS4. Phys Med Biol 2004, 49:387-397.
    • (2004) Phys Med Biol , vol.49 , pp. 387-397
    • Ye, S.J.1    Brezovich, I.A.2    Pareek, P.3
  • 8
    • 0004007304 scopus 로고    scopus 로고
    • University of California, Lawrence Livermore National Laboratory, Livermore, CA, Report No.: UCRL-50400, Rev. 5
    • Cullen D.E., Hubbell J.H., Kissel L. EPDL97: The Evaluated Photon Data Library, '97 Version 1997, University of California, Lawrence Livermore National Laboratory, Livermore, CA, Report No.: UCRL-50400, Vol. 6, Rev. 5.
    • (1997) EPDL97: The Evaluated Photon Data Library, '97 Version , vol.6
    • Cullen, D.E.1    Hubbell, J.H.2    Kissel, L.3
  • 10
    • 84864166247 scopus 로고    scopus 로고
    • [database on the Internet], Brookhaven National Laboratory, Upton, NY, [cited December 28, 2010]
    • National Nuclear Data Center 2010, [database on the Internet], Brookhaven National Laboratory, Upton, NY, [cited December 28, 2010].
    • (2010) National Nuclear Data Center
  • 11
    • 75749106292 scopus 로고    scopus 로고
    • Influence of photon energy spectra from brachytherapy sources on Monte Carlo simulations of kerma and dose rates in water and air
    • Rivard M.J., Granero D., Perez-Calatayud J., et al. Influence of photon energy spectra from brachytherapy sources on Monte Carlo simulations of kerma and dose rates in water and air. Med Phys 2010, 37:869-876.
    • (2010) Med Phys , vol.37 , pp. 869-876
    • Rivard, M.J.1    Granero, D.2    Perez-Calatayud, J.3
  • 12
    • 1142304255 scopus 로고    scopus 로고
    • Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations
    • Rivard M.J., Coursey B.M., DeWerd L.A., et al. Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations. Med Phys 2004, 31:633-674.
    • (2004) Med Phys , vol.31 , pp. 633-674
    • Rivard, M.J.1    Coursey, B.M.2    DeWerd, L.A.3
  • 13
    • 0031739032 scopus 로고    scopus 로고
    • Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source
    • Daskalov G.M., Löffler M., Williamson J.F. Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source. Med Phys 1998, 25:2200-2208.
    • (1998) Med Phys , vol.25 , pp. 2200-2208
    • Daskalov, G.M.1    Löffler, M.2    Williamson, J.F.3
  • 14
    • 0033857386 scopus 로고    scopus 로고
    • Erratum: "Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source"
    • [Med. Phys 25, 2200-2208 (1998)]
    • Daskalov G.M. Erratum: "Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source". Med Phys 2000, 27:1999. [Med. Phys 25, 2200-2208 (1998)].
    • (2000) Med Phys , vol.27 , pp. 1999
    • Daskalov, G.M.1
  • 15
    • 50449095484 scopus 로고    scopus 로고
    • An EGSnrc Monte Carlo-calculated database of TG-43 parameters
    • Taylor R.E., Rogers D.W. An EGSnrc Monte Carlo-calculated database of TG-43 parameters. Med Phys 2008, 35:4228-4241.
    • (2008) Med Phys , vol.35 , pp. 4228-4241
    • Taylor, R.E.1    Rogers, D.W.2
  • 16
  • 17
    • 33846566263 scopus 로고    scopus 로고
    • Benchmarking brachydose: Voxel based EGSnrc Monte Carlo calculations of TG-43 dosimetry parameters
    • Taylor R.E., Yegin G., Rogers D.W. Benchmarking brachydose: Voxel based EGSnrc Monte Carlo calculations of TG-43 dosimetry parameters. Med Phys 2007, 34:445-457.
    • (2007) Med Phys , vol.34 , pp. 445-457
    • Taylor, R.E.1    Yegin, G.2    Rogers, D.W.3
  • 19
    • 0033743901 scopus 로고    scopus 로고
    • The collapsed cone superposition algorithm applied to scatter dose calculations in brachytherapy
    • Carlsson A.K., Ahnesjo A. The collapsed cone superposition algorithm applied to scatter dose calculations in brachytherapy. Med Phys 2000, 27:2320-2332.
    • (2000) Med Phys , vol.27 , pp. 2320-2332
    • Carlsson, A.K.1    Ahnesjo, A.2
  • 20
    • 0033954079 scopus 로고    scopus 로고
    • Point kernels and superposition methods for scatter dose calculations in brachytherapy
    • Carlsson A.K., Ahnesjo A. Point kernels and superposition methods for scatter dose calculations in brachytherapy. Phys Med Biol 2000, 45:357-382.
    • (2000) Phys Med Biol , vol.45 , pp. 357-382
    • Carlsson, A.K.1    Ahnesjo, A.2
  • 21
    • 77950551727 scopus 로고    scopus 로고
    • Homogeneity of Gafchromic EBT2 film
    • Hartmann B., Martisikova M., Jakel O. Homogeneity of Gafchromic EBT2 film. Med Phys 2010, 37:1753-1756.
    • (2010) Med Phys , vol.37 , pp. 1753-1756
    • Hartmann, B.1    Martisikova, M.2    Jakel, O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.