-
1
-
-
0028016869
-
Laboratory and Roofing Exposures of Cellular Plastic Insulation to Verify a Model of Aging, Roofing Research and Standards Development: 3rd Volume
-
Bomberg, M.T. and Kumaran, M.K. (1994). Laboratory and Roofing Exposures of Cellular Plastic Insulation to Verify a Model of Aging, Roofing Research and Standards Development: 3rd Volume, ASTM Special Technical Publication, ASTM, Philadelphia, USA, Vol. 1224, pp. 151-167.
-
(1994)
ASTM Special Technical Publication, ASTM, Philadelphia, USA
, vol.1224
, pp. 151-167
-
-
Bomberg, M.T.1
Kumaran, M.K.2
-
2
-
-
0028530928
-
A Comparative Test Method to Determine Thermal Resistance under Field Conditions
-
Bomberg, M.T., Muzychka, Y.S., Stevens, D.G. and Kumaran, M.K. (1994). A Comparative Test Method to Determine Thermal Resistance under Field Conditions, Journal of Thermal Insulation and Building Envelopes, 18: 163-181.
-
(1994)
Journal of Thermal Insulation and Building Envelopes
, vol.18
, pp. 163-181
-
-
Bomberg, M.T.1
Muzychka, Y.S.2
Stevens, D.G.3
Kumaran, M.K.4
-
3
-
-
46249127757
-
Review of the Air Barrier Issues
-
Bomberg, M., Onysko, D.M. and Lstiburek, J.W. (2004). Review of the Air Barrier Issues, In: ASHRAE/DoE/ORNL IX Conference on Whole Buildings, Florida, December 2004.
-
ASHRAE/DoE/ORNL IX Conference on Whole Buildings
-
-
Bomberg, M.1
Onysko, D.M.2
Lstiburek, J.W.3
-
5
-
-
46249107274
-
On Validation of Hygric Characteristics for Heat, Air and Moisture Models
-
Bomberg, M., Pazera, M. and Zhang, J. (2006). On Validation of Hygric Characteristics for Heat, Air and Moisture Models, In: 3rd Int. Conf. on Building Physics, Montreal.
-
3rd Int. Conf. on Building Physics
-
-
Bomberg, M.1
Pazera, M.2
Zhang, J.3
-
6
-
-
11944254005
-
Water Management in Exterior Wall Claddings
-
Brown, W., Adams, P., Tonyan, T. and Ullet, J. (1997). Water Management in Exterior Wall Claddings, J. Thermal Insulation and Building Envelopes, 21: 23-43.
-
(1997)
J. Thermal Insulation and Building Envelopes
, vol.21
, pp. 23-43
-
-
Brown, W.1
Adams, P.2
Tonyan, T.3
Ullet, J.4
-
7
-
-
12344303541
-
Moisture Accumulation in Cellulose Insulation Caused by Air Leakage in Flat Wood-Frame Roofs
-
Derome, D. (2005). Moisture Accumulation in Cellulose Insulation Caused by Air Leakage in Flat Wood-Frame Roofs, J. Thermal Envelope and Building Science, 28: 269-287.
-
(2005)
J. Thermal Envelope and Building Science
, vol.28
, pp. 269-287
-
-
Derome, D.1
-
8
-
-
0031118237
-
Measurements and 2-D Computer Simulations of Hygrothermal Performance of Wood Frame Wall
-
Giving, S., Karagiosis, A. and Salonvaara, M. (1997). Measurements and 2-D Computer Simulations of Hygrothermal Performance of Wood Frame Wall, J. Thermal Insul. and Bldg. Envelopes, 20: 301-319.
-
(1997)
J. Thermal Insul. and Bldg. Envelopes
, vol.20
, pp. 301-319
-
-
Giving, S.1
Karagiosis, A.2
Salonvaara, M.3
-
9
-
-
0020917474
-
Calculated versus Measured Thermal Resistances of Simulated Building Walls Incorporating Airspaces
-
Greason, D.M. (1983). Calculated versus Measured Thermal Resistances of Simulated Building Walls Incorporating Airspaces, ASHRAE Transactions, Vol. 89, Pt. 1 (preprint AC-83-12 No. 3).
-
(1983)
ASHRAE Transactions
, vol.89
-
-
Greason, D.M.1
-
10
-
-
84976915803
-
A Method for Determining the Thermal Resistance of Experimental Flat Roof Systems using Flat Roof Systems
-
Hedlin, C.P., Orr, H.W. and Tao, S.S. (1980). A Method for Determining the Thermal Resistance of Experimental Flat Roof Systems using Flat Roof Systems, ASTM STP, 718: 307-321.
-
(1980)
ASTM STP
, vol.718
, pp. 307-321
-
-
Hedlin, C.P.1
Orr, H.W.2
Tao, S.S.3
-
12
-
-
0034291844
-
Transient Interaction of Buildings with HVAC Systems - Updating the State of the Art
-
Lstiburek, J.W., Pressnail, K. and Timusk, J. (2000). Transient Interaction of Buildings with HVAC Systems - Updating the State of the Art, J. Thermal Env. and Building Science, 24: 111-131.
-
(2000)
J. Thermal Env. and Building Science
, vol.24
, pp. 111-131
-
-
Lstiburek, J.W.1
Pressnail, K.2
Timusk, J.3
-
13
-
-
0036541206
-
Evaluating the Air Pressure Response of Multizonal Buildings
-
Lstiburek, J.W., Pressnail, K. and Timusk, J. (2002). Evaluating the Air Pressure Response of Multizonal Buildings, J. Thermal Env. and Building Science, 25: 299-320.
-
(2002)
J. Thermal Env. and Building Science
, vol.25
, pp. 299-320
-
-
Lstiburek, J.W.1
Pressnail, K.2
Timusk, J.3
-
14
-
-
0031117960
-
Long-term Field Monitoring of EIFS Clad Wall
-
Said, M.N.A., Brown, W.C. and Walker, I.S. (1997). Long-term Field Monitoring of EIFS Clad Wall, J. Thermal Insulation and Building Envelopes, 20: 320-338.
-
(1997)
J. Thermal Insulation and Building Envelopes
, vol.20
, pp. 320-338
-
-
Said, M.N.A.1
Brown, W.C.2
Walker, I.S.3
-
15
-
-
9644279876
-
Effect of Exfiltration on Hygrothermal Behaviour of a Residential Wall Assembly
-
Ojnanen, T.R. and Kumaran, M.K. (1996). Effect of Exfiltration on Hygrothermal Behaviour of a Residential Wall Assembly, J. Thermal Envs. and Bldg. Envs., 19: 215-228.
-
(1996)
J. Thermal Envs. and Bldg. Envs.
, vol.19
, pp. 215-228
-
-
Ojnanen, T.R.1
Kumaran, M.K.2
-
16
-
-
36249001488
-
Air Tightness of Wall Sheathing as a Function of Lumber Drying. Proceedings of the
-
Onysko, D.M. and Jones, S.K. (1989). Air Tightness of Wall Sheathing as a Function of Lumber Drying. Proceedings of the ASHRAE/DOE/BTECC/CIBSE Conference. Thermal Performance of the Exterior Envelopes of Buildings IV.
-
ASHRAE/DOE/BTECC/CIBSE Conference
-
-
Onysko, D.M.1
Jones, S.K.2
-
17
-
-
46249117181
-
Air Tightness of Joints in Wall Sheathing as a Function of Lumber Drying
-
Onysko, D.M. (2001). Air Tightness of Joints in Wall Sheathing as a Function of Lumber Drying, In: ICBEST Conference, ON, Canada.
-
ICBEST Conference, ON, Canada
-
-
Onysko, D.M.1
-
19
-
-
0033746590
-
Effect of Mechanical Fasteners and Gaps between Insulation Boards on Thermal Performance of Low-slope Roofs
-
Petrie, T.W., Atchley, G., Desjarlais, A.O. and Christian, J.E. (2000). Effect of Mechanical Fasteners and Gaps between Insulation Boards on Thermal Performance of Low-slope Roofs, J. Thermal Envelope and Building Science, 23: 292-317.
-
(2000)
J. Thermal Envelope and Building Science
, vol.23
, pp. 292-317
-
-
Petrie, T.W.1
Atchley, G.2
Desjarlais, A.O.3
Christian, J.E.4
-
20
-
-
2342505761
-
Interlaboratory Comparison of Hygric Properties of Porous Building Materials
-
Roels, S., Carmeliet, J., Hens, H., Adan, O., Brocken, H., Cerny, R., Pavlik, Z., Hall, C. h., Kumaran, K., Pel, L. and Plagge, R. (2004). Interlaboratory Comparison of Hygric Properties of Porous Building Materials, Journal of Th. Env. and Bld. Sci., 27: 307-326.
-
(2004)
Journal of Th. Env. and Bld. Sci.
, vol.27
, pp. 307-326
-
-
Roels, S.1
Carmeliet, J.2
Hens, H.3
Adan, O.4
Brocken, H.5
Cerny, R.6
Pavlik, Z.7
Hall, C.8
Kumaran, K.9
Pel, L.10
Plagge, R.11
-
23
-
-
0030190067
-
The Importance of Wind Barriers for Insulated Timber Frame Constructions
-
Uvslokk, S. (1996). The Importance of Wind Barriers for Insulated Timber Frame Constructions, J. Thermal Envelope and Building Science, 20: 40-62.
-
(1996)
J. Thermal Envelope and Building Science
, vol.20
, pp. 40-62
-
-
Uvslokk, S.1
|