메뉴 건너뛰기




Volumn 36, Issue 9, 2012, Pages 2156-2160

Surgical outcome of liver transection by the crush-clampingtechnique combined with harmonic focus Tm

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ARTICLE; BLEEDING; FEMALE; HEMOSTASIS; HUMAN; INSTRUMENTATION; LIGATION; LIVER; LIVER DISEASE; LIVER RESECTION; MALE; METHODOLOGY; MIDDLE AGED; RETROSPECTIVE STUDY; SURGICAL EQUIPMENT; TREATMENT OUTCOME; ULTRASOUND SURGERY;

EID: 84867854890     PISSN: 03642313     EISSN: 14322323     Source Type: Journal    
DOI: 10.1007/s00268-012-1624-y     Document Type: Article
Times cited : (14)

References (13)
  • 1
    • 0033768653 scopus 로고    scopus 로고
    • Hepatic resection using the harmonic scalpel
    • Sugo H, Mikami Y, Matsumoto F et al (2000) Hepatic resection using the harmonic scalpel. Surg Today 30:959-962
    • (2000) Surg Today , vol.30 , pp. 959-962
    • Sugo, H.1    Mikami, Y.2    Matsumoto, F.3
  • 2
    • 1542375964 scopus 로고    scopus 로고
    • Bloodless liver resection using the monopolar floating ball plus ligasure diathermy: Preliminary results of 16 liver resections
    • doi101007/s00268-003-7167-7175
    • Sakamoto Y, Yamamoto J, Kokudo N et al (2004) Bloodless liver resection using the monopolar floating ball plus Ligasure diathermy: preliminary results of 16 liver resections. World J Surg 28:166-172. doi:10.1007/s00268-003-7167-5
    • (2004) World J Surg , vol.28 , pp. 166-172
    • Sakamoto, Y.1    Yamamoto, J.2    Kokudo, N.3
  • 3
    • 34250655743 scopus 로고    scopus 로고
    • Current techniques of liver transection
    • Poon RT (2007) Current techniques of liver transection. HPB (Oxford) 9:166-173
    • (2007) HPB (Oxford) , vol.9 , pp. 166-173
    • Poon, R.T.1
  • 4
    • 68949083586 scopus 로고    scopus 로고
    • The vessel sealing system (ligasure) in hepatic resection: A randomized controlled trial
    • Ikeda M, Hasegawa K, Sano K et al (2009) The vessel sealing system (Ligasure) in hepatic resection: a randomized controlled trial. Ann Surg 250:199-203
    • (2009) Ann Surg , vol.250 , pp. 199-203
    • Ikeda, M.1    Hasegawa, K.2    Sano, K.3
  • 5
    • 73649134644 scopus 로고    scopus 로고
    • Fusion technique for liver transection with kelly-clysis and harmonic technology
    • doi101007/s00268-009-0282-0291
    • Jagannath P,ChhabraDG, SutariyaKRet al (2010)Fusion technique for liver transection with Kelly-clysis and harmonic technology. World J Surg 34:101-105. doi:10.1007/s00268-009-0282-1
    • (2010) World J Surg , vol.34 , pp. 101-105
    • Jagannath, P.1    Chhabra, D.G.2    Sutariya, K.R.3
  • 6
    • 33744931633 scopus 로고    scopus 로고
    • Usefulness of ligasure for liver resection: Analysis by randomized clinical trial
    • Saiura A, Yamamoto J, Koga R et al (2006) Usefulness of Ligasure for liver resection: analysis by randomized clinical trial. Am J Surg 192:41-45
    • (2006) Am J Surg , vol.192 , pp. 41-45
    • Saiura, A.1    Yamamoto, J.2    Koga, R.3
  • 7
    • 32944457396 scopus 로고    scopus 로고
    • Stapler hepatectomy is a safe dissection technique: Analysis of 300 patients
    • doi101007/s00268-005-0192-0199
    • Schemmer P, Friess H, Hinz U et al (2006) Stapler hepatectomy is a safe dissection technique: analysis of 300 patients. World J Surg 30:419-430. doi:10.1007/s00268-005-0192-9
    • (2006) World J Surg , vol.30 , pp. 419-430
    • Schemmer, P.1    Friess, H.2    Hinz, U.3
  • 8
    • 77955122220 scopus 로고    scopus 로고
    • Usefulness of the combination procedure of crash clamping and vessel sealing for hepatic resection
    • Nanashima A, Tobinaga S, Abo T et al (2010) Usefulness of the combination procedure of crash clamping and vessel sealing for hepatic resection. J Surg Oncol 102:179-183
    • (2010) J Surg Oncol , vol.102 , pp. 179-183
    • Nanashima, A.1    Tobinaga, S.2    Abo, T.3
  • 10
    • 0035146422 scopus 로고    scopus 로고
    • A model to predict survival in patients with end-stage liver disease
    • Kamath PS, Wiesner RH, Malinchoc M et al (2001) A model to predict survival in patients with end-stage liver disease. Hepatology 33:464-470
    • (2001) Hepatology , vol.33 , pp. 464-470
    • Kamath, P.S.1    Wiesner, R.H.2    Malinchoc, M.3
  • 11
    • 34147146445 scopus 로고    scopus 로고
    • A prospective evaluation of ultrasonic dissector plus harmonic scalpel in liver resection
    • Arru M, Pulitano C, Aldrighetti L et al (2007) A prospective evaluation of ultrasonic dissector plus harmonic scalpel in liver resection. Am Surg 73:256-260
    • (2007) Am Surg , vol.73 , pp. 256-260
    • Arru, M.1    Pulitano, C.2    Aldrighetti, L.3
  • 12
    • 37749035417 scopus 로고    scopus 로고
    • The ligasure vessel sealer in liver resection: A pilot study
    • Chiappa A, Zbar AP, Bertani E et al (2007) The Ligasure vessel sealer in liver resection: a pilot study. Hepatogastroenterology 54:2353-2357
    • (2007) Hepatogastroenterology , vol.54 , pp. 2353-2357
    • Chiappa, A.1    Zbar, A.P.2    Bertani, E.3
  • 13
    • 0034904303 scopus 로고    scopus 로고
    • Randomized comparison of ultrasonic vs clamp transection of the liver
    • Takayama T, Makuuchi M, Kubota K et al (2001) Randomized comparison of ultrasonic vs clamp transection of the liver. Arch Surg 136:922-928
    • (2001) Arch Surg , vol.136 , pp. 922-928
    • Takayama, T.1    Makuuchi, M.2    Kubota, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.