Volumn 102, Issue 2, 2010, Pages 179-183

Usefulness of the combination procedure of crash clamping and vessel sealing for hepatic resection

Author keywords

Bloodless; Crush clamping; Hepatectomy; Vessel sealing

Indexed keywords

ABDOMINAL ABSCESS; ADULT; AGED; ARTICLE; BLEEDING; CLINICAL ARTICLE; CONTROLLED STUDY; CRUSH CLAMPING; FEMALE; FORCEPS; HEMOSTASIS; HUMAN; LIVER CIRRHOSIS; LIVER INJURY; LIVER RESECTION; MALE; PRIORITY JOURNAL; SURGICAL TECHNIQUE; VESSEL SEALING;

EID: 77955122220     PISSN: 00224790     EISSN: 10969098     Source Type: Journal    
DOI: 10.1002/jso.21575     Document Type: Article
Times cited : (23)

References (14)
  • 1
    • 0029048103 scopus 로고
    • Criteria for safe hepatic resection
    • Miyagawa S, Makuuchi M, Kawasaki S, et al.: Criteria for safe hepatic resection. Am J Surg 1995;169:589-594.
    • (1995) Am J Surg , vol.169 , pp. 589-594
    • Miyagawa, S.1    Makuuchi, M.2    Kawasaki, S.3
  • 2
    • 67649230602 scopus 로고    scopus 로고
    • Perioperative factors affecting long-term outcomes of 473 consecutive patients undergoing hepatectomy for hepatocellular carcinoma
    • Wang CC, Iyer SG, Low JK, et al.: Perioperative factors affecting long-term outcomes of 473 consecutive patients undergoing hepatectomy for hepatocellular carcinoma. Ann Surg Oncol 2009;16:1832-1842.
    • (2009) Ann Surg Oncol , vol.16 , pp. 1832-1842
    • Wang, C.C.1    Iyer, S.G.2    Low, J.K.3
  • 3
    • 34250655743 scopus 로고    scopus 로고
    • Current techniques of liver transection
    • Poon RT: Current techniques of liver transection. HPB 2007; 9:166-173.
    • (2007) HPB , vol.9 , pp. 166-173
    • Poon, R.T.1
  • 4
    • 49049091996 scopus 로고    scopus 로고
    • Liver resection with bipolar radiofrequency device: Habib™ 4X
    • Pai M, Jiao LR, Khorsandi S, et al.: Liver resection with bipolar radiofrequency device: Habib™ 4X. HPB 2008;10:256-260.
    • (2008) HPB , vol.10 , pp. 256-260
    • Pai, M.1    Jiao, L.R.2    Khorsandi, S.3
  • 5
    • 34147146445 scopus 로고    scopus 로고
    • A prospective evaluation of ultrasonic dissector plus harmonic scalpel in liver resection
    • Arru M, Pulitanó C, Aldrighetti L, et al.: A prospective evaluation of ultrasonic dissector plus harmonic scalpel in liver resection. Am Surg 2007;73:256-260. (Pubitemid 351396705)
    • (2007) American Surgeon , vol.73 , Issue.3 , pp. 256-260
    • Arru, M.1    Pulitano, C.2    Aldrighetti, L.3    Catena, M.4    Finazzi, R.5    Ferla, G.6
  • 6
    • 67349201395 scopus 로고    scopus 로고
    • Laparoscopic left lobe liver resection in a porcine model: A study of the efficacy and safety of different surgical techniques
    • Kristinn E, Diddi F, Sten R, et al.: Laparoscopic left lobe liver resection in a porcine model: A study of the efficacy and safety of different surgical techniques. Surg Endosc 2009;23: 1038-1042.
    • (2009) Surg Endosc , vol.23 , pp. 1038-1042
    • Kristinn, E.1    Diddi, F.2    Sten, R.3
  • 7
    • 0035270092 scopus 로고    scopus 로고
    • A novel technique for parenchymal division during hepatectomy
    • Horgan PG: A novel technique for parenchymal division during hepatectomy. Am J Surg 2001;181:236-237.
    • (2001) Am J Surg , vol.181 , pp. 236-237
    • Horgan, P.G.1
  • 9
    • 48949102171 scopus 로고    scopus 로고
    • The use of saline-linked radiofrequency dissecting sealer for liver transection in patients with cirrhosis
    • Xia F, Wang S, Ma K, et al.: The use of saline-linked radiofrequency dissecting sealer for liver transection in patients with cirrhosis. J Surg Res 2008;149:110-114.
    • (2008) J Surg Res , vol.149 , pp. 110-114
    • Xia, F.1    Wang, S.2    Ma, K.3
  • 10
    • 43749124249 scopus 로고    scopus 로고
    • Temperature safety profile of laparoscopic devices: Harmonic ACE (ACE), Ligasure V (LV), and plasma trisector (PT)
    • Kim FJ, Chammans MF, Jr., Gewehr E, et al.: Temperature safety profile of laparoscopic devices: Harmonic ACE (ACE), Ligasure V (LV), and plasma trisector (PT). Surg Endosc 2008;22:1464-1469.
    • (2008) Surg Endosc , vol.22 , pp. 1464-1469
    • Kim, F.J.1    Chammans Jr., M.F.2    Gewehr, E.3
  • 11
    • 1542541444 scopus 로고    scopus 로고
    • Increased biliary fistulas after liver resection with the harmonic scalpel
    • Kim J, Ahmad SA, Lowy AM, et al.: Increased biliary fistulas after liver resection with the harmonic scalpel. Am Surg 2003;69:815-819.
    • (2003) Am Surg , vol.69 , pp. 815-819
    • Kim, J.1    Ahmad, S.A.2    Lowy, A.M.3
  • 12
    • 68949083586 scopus 로고    scopus 로고
    • The vessel sealing system (LigaSure) in hepatic resection. A randomized controlled trial
    • Ikeda M, Hasegawa K, Sano K, et al.: The vessel sealing system (LigaSure) in hepatic resection. A randomized controlled trial. Ann Surg 2009;250:199-203.
    • (2009) Ann Surg , vol.250 , pp. 199-203
    • Ikeda, M.1    Hasegawa, K.2    Sano, K.3
  • 13
    • 49049099255 scopus 로고    scopus 로고
    • Liver transection using the LigaSure sealing system
    • Saiura A, Yamamoto J, Koga R, et al.: Liver transection using the LigaSure sealing system. HPB 2008;10:239-243.
    • (2008) HPB , vol.10 , pp. 239-243
    • Saiura, A.1    Yamamoto, J.2    Koga, R.3
  • 14
    • 34447504699 scopus 로고    scopus 로고
    • Postoperative outcomes in patients with hepatocellular carcinomas resected with exposure of the tumor surface: Clinical role of the no-margin resection
    • Matsui Y, Terakawa N, Satoi S, et al.: Postoperative outcomes in patients with hepatocellular carcinomas resected with exposure of the tumor surface: Clinical role of the no-margin resection. Arch Surg 2007;142:596-602.
    • (2007) Arch Surg , vol.142 , pp. 596-602
    • Matsui, Y.1    Terakawa, N.2    Satoi, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.