-
2
-
-
79955649370
-
Measuring the absolute water content of the brain using quantitative MRI
-
Shah NJ, Ermer V, Oros-Preusquens AM,. Measuring the absolute water content of the brain using quantitative MRI. Methods Mol Biol 2011; 711: 29-64.
-
(2011)
Methods Mol Biol
, vol.711
, pp. 29-64
-
-
Shah, N.J.1
Ermer, V.2
Oros-Preusquens, A.M.3
-
3
-
-
33644813235
-
1 mapping by variable flip angles: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity
-
1 mapping by variable flip angles: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity. Magn Reson Med 2006; 55: 566-574.
-
(2006)
Magn Reson Med
, vol.55
, pp. 566-574
-
-
Cheng, H.L.M.1
Wright, G.A.2
-
4
-
-
35148865818
-
1 with high-speed incorporation of RF field inhomogeneities (DESPOT1-HIFI)
-
1 with high-speed incorporation of RF field inhomogeneities (DESPOT1-HIFI). J Magn Reson Imaging 2007; 26: 1106-1111.
-
(2007)
J Magn Reson Imaging
, vol.26
, pp. 1106-1111
-
-
Deoni, S.C.L.1
-
6
-
-
0040686062
-
Biplanar radiofrequency coil design
-
Roberts DA, Insko EK, Bolinger L, Leigh JS,. Biplanar radiofrequency coil design. J Magn Reson 1993; 102: 34-41.
-
(1993)
J Magn Reson
, vol.102
, pp. 34-41
-
-
Roberts, D.A.1
Insko, E.K.2
Bolinger, L.3
Leigh, J.S.4
-
7
-
-
0030671545
-
1 pattern for sodium and proton imaging of the human brain at 1.5 T
-
1 pattern for sodium and proton imaging of the human brain at 1.5 T. Magn Reson Med 1997; 38: 717-725.
-
(1997)
Magn Reson Med
, vol.38
, pp. 717-725
-
-
Shen, G.X.1
Boada, F.E.2
Thulborn, K.R.3
-
8
-
-
0028339167
-
Sources of intensity nonuniformity in spin echo images at 1.5 T
-
Simmons A, Tofts PS, Barker GJ, Arridge SR,. Sources of intensity nonuniformity in spin echo images at 1.5 T. Magn Reson Med 1994; 32: 121-128.
-
(1994)
Magn Reson Med
, vol.32
, pp. 121-128
-
-
Simmons, A.1
Tofts, P.S.2
Barker, G.J.3
Arridge, S.R.4
-
9
-
-
0001184266
-
Comparison of linear and circular polarization for magnetic resonance imaging
-
Glover GH, Hayes CE, Pelc NJ, Edelstein WA, Mueller OM, Hart HR, Hardy CJ, O'Donnell M, Barber WD,. Comparison of linear and circular polarization for magnetic resonance imaging. J Magn Reson 1985; 64: 255-270.
-
(1985)
J Magn Reson
, vol.64
, pp. 255-270
-
-
Glover, G.H.1
Hayes, C.E.2
Pelc, N.J.3
Edelstein, W.A.4
Mueller, O.M.5
Hart, H.R.6
Hardy, C.J.7
O'Donnell, M.8
Barber, W.D.9
-
10
-
-
0018190215
-
RF magnetic field penetration, phase shift and power dissipation in biological tissue: Implications for NMR imaging
-
Bottomley, P. A., and, Andrew, E. R., RF magnetic field penetration, phase shift and power dissipation in biological tissue: implications for NMR imaging. Phys Med Biol 1978; 23: 630-643.
-
(1978)
Phys Med Biol
, vol.23
, pp. 630-643
-
-
Bottomley, P.A.1
Andrew, E.R.2
-
11
-
-
53549085458
-
A phase-sensitive method of flip angle mapping
-
Morrell GR,. A phase-sensitive method of flip angle mapping. Magn Reson Med 2008; 60: 889-894.
-
(2008)
Magn Reson Med
, vol.60
, pp. 889-894
-
-
Morrell, G.R.1
-
14
-
-
12844266240
-
Measurement and correction of transmitter and receiver induced nonuniformities in vivo
-
Wang J, Qiu M, Yang QX, Smith MB, Constable RT,. Measurement and correction of transmitter and receiver induced nonuniformities in vivo. Magn Reson Med 2005; 53: 408-417.
-
(2005)
Magn Reson Med
, vol.53
, pp. 408-417
-
-
Wang, J.1
Qiu, M.2
Yang, Q.X.3
Smith, M.B.4
Constable, R.T.5
-
16
-
-
33846078031
-
Actual flip-angle imaging in the pulsed steady state: A method for rapid three-dimensional mapping of the transmitted radiofrequency field
-
Yarnykh VL,. Actual flip-angle imaging in the pulsed steady state: A method for rapid three-dimensional mapping of the transmitted radiofrequency field. Magn Reson Med 2007; 57: 192-200.
-
(2007)
Magn Reson Med
, vol.57
, pp. 192-200
-
-
Yarnykh, V.L.1
-
17
-
-
60349112457
-
On the steady-state properties of actual flip angle imaging (AFI)
-
Nehrke K,. On the steady-state properties of actual flip angle imaging (AFI). Magn Reson Med 2009; 61: 84-92.
-
(2009)
Magn Reson Med
, vol.61
, pp. 84-92
-
-
Nehrke, K.1
-
18
-
-
0027253712
-
Radiofrequency map of an NMR coil by imaging
-
Akoka S, Franconi F, Seguin F, Le Pape A,. Radiofrequency map of an NMR coil by imaging. Magn Reson Imag 1993; 11: 437-441.
-
(1993)
Magn Reson Imag
, vol.11
, pp. 437-441
-
-
Akoka, S.1
Franconi, F.2
Seguin, F.3
Le Pape, A.4
-
19
-
-
0031821719
-
Quantitative spectroscopic imaging of the human brain
-
Pan JW, Twieg DB, Hetherington HP,. Quantitative spectroscopic imaging of the human brain. Magn Reson Med 1998; 40: 363-369.
-
(1998)
Magn Reson Med
, vol.40
, pp. 363-369
-
-
Pan, J.W.1
Twieg, D.B.2
Hetherington, H.P.3
-
20
-
-
33746780623
-
Factors influencing flip angle mapping in MRI: RF pulse shape, slice-select gradients, off-resonance excitation, and B0 inhomogeneities
-
Wang J, Mao W, Qiu M, Smith MB, Constable RT,. Factors influencing flip angle mapping in MRI: RF pulse shape, slice-select gradients, off-resonance excitation, and B0 inhomogeneities. Magn Reson Med 2006; 56: 463-468.
-
(2006)
Magn Reson Med
, vol.56
, pp. 463-468
-
-
Wang, J.1
Mao, W.2
Qiu, M.3
Smith, M.B.4
Constable, R.T.5
-
21
-
-
75749116305
-
+-Map acquisition for fast localized shim, frequency, and RF power determination in the heart at 3 T
-
+-Map acquisition for fast localized shim, frequency, and RF power determination in the heart at 3 T. Magn Reson Med 2010; 63: 419-426.
-
(2010)
Magn Reson Med
, vol.63
, pp. 419-426
-
-
Schär, M.1
Vonken, E.J.2
Stuber, M.3
-
23
-
-
0000895138
-
Experimental determination of three-dimensional RF magnetic field distribution of nmr coils
-
Talagala SL, Gillen J,. Experimental determination of three-dimensional RF magnetic field distribution of nmr coils. J Magn Reson 1991; 94: 493-500.
-
(1991)
J Magn Reson
, vol.94
, pp. 493-500
-
-
Talagala, S.L.1
Gillen, J.2
-
24
-
-
0030610697
-
Direct visualisation of B1 inhomogeneity by flip angle dependency
-
Zelaya FO, Roffmann WU, Crozier S, Teed S, Gross D, Doddrell DM,. Direct visualisation of B1 inhomogeneity by flip angle dependency. Magn Reson Imaging 1997; 4: 497-504.
-
(1997)
Magn Reson Imaging
, vol.4
, pp. 497-504
-
-
Zelaya, F.O.1
Roffmann, W.U.2
Crozier, S.3
Teed, S.4
Gross, D.5
Doddrell, D.M.6
-
26
-
-
0000748280
-
Depth and refocusing pulses designed for multipulse NMR with surface coils
-
Bendall MR, Gordon RE,. Depth and refocusing pulses designed for multipulse NMR with surface coils. J Magn Reson 1983; 53: 365-385.
-
(1983)
J Magn Reson
, vol.53
, pp. 365-385
-
-
Bendall, M.R.1
Gordon, R.E.2
-
28
-
-
0028081569
-
An integrated program for amplitude-modulated RF pulse generation and re-mapping with shaped gradients
-
Matson GB,. An integrated program for amplitude-modulated RF pulse generation and re-mapping with shaped gradients. Magn Reson Imaging 1994; 12: 1205-1225.
-
(1994)
Magn Reson Imaging
, vol.12
, pp. 1205-1225
-
-
Matson, G.B.1
-
29
-
-
0026116321
-
Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm
-
Pauly J, Le Roux P, Nishimura D, Macovski A,. Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm. IEEE Trans Med Imaging 1991; 10: 53-65.
-
(1991)
IEEE Trans Med Imaging
, vol.10
, pp. 53-65
-
-
Pauly, J.1
Le Roux, P.2
Nishimura, D.3
MacOvski, A.4
-
30
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland JM, Altman DG,. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310.
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
31
-
-
84975207356
-
A note on the concordance correlation coefficient
-
Lin LI,. A note on the concordance correlation coefficient. Biometrics 2000; 56: 324-325.
-
(2000)
Biometrics
, vol.56
, pp. 324-325
-
-
Lin, L.I.1
-
32
-
-
0025388423
-
A fast parallel algorithm for blind estimation of noise variance
-
Meer P, Jolion JM, Rosenfeld A,. A fast parallel algorithm for blind estimation of noise variance. IEEE 1990; 2: 216-223.
-
(1990)
IEEE
, vol.2
, pp. 216-223
-
-
Meer, P.1
Jolion, J.M.2
Rosenfeld, A.3
-
33
-
-
4744349011
-
Inherent insensitivity to RF inhomogeneity in FLASH imaging
-
Wang D, Heberlein K, LaConte S, Hu X,. Inherent insensitivity to RF inhomogeneity in FLASH imaging. Magn Reson Med 2004; 52: 927-931.
-
(2004)
Magn Reson Med
, vol.52
, pp. 927-931
-
-
Wang, D.1
Heberlein, K.2
Laconte, S.3
Hu, X.4
|