메뉴 건너뛰기




Volumn 66, Issue 5, 2012, Pages 453-465

Container/closure integrity testing and the identification of a suitable vial/stopper combination for low-temperature storage at -80 °C

Author keywords

Container closure integrity; Frequency modulation spectroscopy; Glass transition temperature; Headspace analysis; Live viral vaccines; Storage at 80 C

Indexed keywords

BUFFER; SODIUM CHLORIDE; GLASS; RUBBER;

EID: 84867797846     PISSN: 10797440     EISSN: 19482124     Source Type: Journal    
DOI: 10.5731/pdajpst.2012.00884     Document Type: Article
Times cited : (20)

References (10)
  • 2
  • 3
    • 1842430476 scopus 로고    scopus 로고
    • Application of Frequency-Modulated Spectroscopy in Vacuum Seal Integrity Testing of Lyophilized Biological Products
    • Lin, T. P.; Hsu, C. C.; Kabakoff, D. B.; Patapoff, T. W. Application of frequency-modulated spectroscopy in vacuum seal integrity of lyophilized biological products. PDA J. Pharm. Sci. Technol. 2004, 58 (2), 106-115. (Pubitemid 38437343)
    • (2004) PDA Journal of Pharmaceutical Science and Technology , vol.58 , Issue.2 , pp. 106-115
    • Lin, T.P.1    Hsu, C.C.2    Kabakoff, B.D.3    Patapoff, T.W.4
  • 4
    • 26844452862 scopus 로고    scopus 로고
    • Frequency modulation spectroscopy: A novel nondestructive approach for measuring moisture activity in pharmaceutical samples
    • Mahajan, R.; Templeton, A. C.; Reed, R. A.; Chern, R. T. Frequency modulation spectroscopy: a novel non-destructive approach for measuring moisture activity in pharmaceutical samples. Pharm. Technol. 2005, 29 (10), 88-104. (Pubitemid 41456476)
    • (2005) Pharmaceutical Technology , vol.29 , Issue.10 , pp. 88-104
    • Mahajan, R.1    Templeton, A.C.2    Reed, R.A.3    Chern, R.T.4
  • 5
    • 80052991208 scopus 로고    scopus 로고
    • Applications of headspace moisture analysis for investigating the water dynamics within a sealed vial containing freezedried material
    • Cook, I.; Ward, K. Applications of headspace moisture analysis for investigating the water dynamics within a sealed vial containing freezedried material. PDA J. Pharm. Sci. Technol. 2011, 65 (1), 2-11.
    • (2011) PDA J. Pharm. Sci. Technol. , vol.65 , Issue.1 , pp. 2-11
    • Cook, I.1    Ward, K.2
  • 6
    • 84867807634 scopus 로고    scopus 로고
    • New Inspection Developments
    • Lysfjord, J., Ed.; Davis Healthcare International Publishing/PDA: Bethesda, MD
    • Veale, James R. New Inspection Developments. In Practical Aseptic Processing Fill and Finish; Lysfjord, J., Ed.; Davis Healthcare International Publishing/PDA: Bethesda, MD, 2009; pp 305-372.
    • (2009) Practical Aseptic Processing Fill and Finish , pp. 305-372
    • Veale, J.R.1
  • 10
    • 1842573881 scopus 로고    scopus 로고
    • PDA Technical Report No. 27. PDA: Bethesda, MD
    • PDA Technical Report No. 27. Pharmaceutical Package Integrity. PDA: Bethesda, MD, 1998.
    • (1998) Pharmaceutical Package Integrity


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.